Specification Range 11th Edition - Vent-Axia - 2017

Specification Range 11th Edition The UK’s Leading Ventilation Company www.vent-axia.com

A warm welcome to the latest edition of the Vent-Axia Specification Range catalogue.As part of the ongoing drive for energy efficiency within Europe, ventilation devices over 30 Watts come under the scope of the Energy Related Products Directive that came into force on 1st January 2016. The legislation sets minimum performance criteria across a range of fans and ventilation devices under two sets of legislation; ‘residential’ ventilation and ‘non-residential’ ventilation. As a result of the legislation we have reviewed our products and where required made updates to ensure they comply. In line with Vent-Axia’s drive to provide the best solution for our customer, we have taken the opportunity to update and improve some products at the same time as bringing the products in-line with ErP regulations. We have also improved the way we supply some of them - giving you more choice and flexibility over how you stock and sell the products. This edition of our Specification Range catalogue shows the continued investment we are making in our products and services to improve and add to our already comprehensive range. In this catalogue, we have bought together our Lo-Carbon residential and our non-residential products in one place providing what we believe to be the best solutions for a wide range of specification today. We have introduced many new models which expand upon our traditional, well-proven products as well as broadening our capabilities further with a whole host of innovations in Vent-Axia Lo-Carbon and energy reducing ventilation solutions. For example, the EKF kitchen fan has a built in EC motor speed control, high temperature rating of up to 120 degrees, motor out of the airstream and specific fan powers of below 1 W/l/s; we believe there is no better solution available.We thank you for your continued custom and feedback, and are always willing to answer any questions you may have. If you need to contact us, please email sales@vent-axia.com, or speak to your local representative who will be happy to help. Kind Regards Mark Hoskins Managing Director Why choose Vent-Axia Vent-Axia supplies heat recovery solutions to countries around the world, whose building regulations already demand the most effective, sustainable and energy efficient ventilation solutions. We are with you all the way •Unparalleled customer service •Industry leading design support •Providing support and solutions on-site Availability •With the widest distribution network of any manufacturer in the UK we pride ourselves on having products available when and where you need themProduct solutions •Whatever the product category, we have the most energy efficient solutions available •Unique solutions designed to fit into all your buildings •With absolute focus on the end user we work hard to produce the quietest, most comfortable products for occupiers to live with Unparalleled Customer Service On-site Support Industry Leading Design Support Widest UK Distribution Network Ventilation Solutions

Legislation Approved Document F 2010 - Means of Ventilation The purpose of this regulation is to ensure adequate means of ventilation is provided for people in the building. According to the document, ventilation is the ‘removal of stale air from a building and replacement with freshoutside air.’ By providing fresh outside air to breath, ventilation assists in the dilution and removal of pollutants as well as a reduction in humidity/condensation, which combined create a more pleasant environment and relief for asthma and allergy sufferers. Part F is a performance based whole building solution stating not only what should be achieved, but also guidance on how this can be achieved. The pollutants in today’s modern dwellings has lead to these changes, with the types of pollutant and the acceptable levels now detailed in the Approved Document Part F 2010. Nitrogen Dioxide (NO 2 ) Carbon Monoxide (CO 2 ) Total volatile compounds (TVOC) Bio-effluents (body odours) Within ADF 2010, Ventilation requirements for new build properties reference the whole dwelling based on an analysis of floor area, number of bedrooms and occupants. There are four systems covered in ADF 2010 including Intermittent Extract Fans, Passive Stack, Continuous Mechanical Extract Ventilation (MEV) and Mechanical Ventilation with Heat Recovery (MVHR). A guide called the ‘Domestic Ventilation Compliance Guide’ is available. This covers installation practices as well as sign off and commissioning.Efficiency regulations require buildings to be better sealed and more airtight. In ADF 2010 there are two ventilation rates based on the deign infiltration rate of your building. There is one rate for properties with infiltration rates over 5m 3 h/m 2(leakier properties) and a higherventilation rate for properties below 5m 3 h/m 2(tighter properties).Thepractical outcome of this means that in airtight properties, the following applies: •Trickle vents with intermittent fans are up to 50% bigger •MVHR rates are increased With MEV in properties at 5m 3 h/m 2or over no trickle vents are needed. Guidance is available for ventilation of basements in houses and trickle ventilation for replacement windows. Compliance with Part F requires installed performance to meet the ventilation rates quoted in the Document. This means that ventilation has to be commissioned and signed off by a competent person. Noise With increasing airtightness the acoustic properties also improve leading to a reduction in external noise entering our dwellings. However this makes any noise generated inside the property even more noticeable, so in Part F a maximumnoise level of 35dB(A) has been set for the trickle speed on continuous ventilation systems. Approved Document L 2013 – Conservation of Fuel and Power These documents set minimum performance levels for ventilation efficiencies and reducing the consumption of the systems. These regulations have brought some significant changes to the ventilation sector in a bid to improve both air quality and energy efficiency. Part L – Overview •Target emission rates, along with fabric energy efficiencystandards areaimed at reducing the carbon emissions by 6%•Non-domestic building services compliance guide shows specific fan power requirements. Heat recovery efficiency minimums to EN308 test standard •Specific fan power (SFP) targets of 1 W/l/s for new orreplacement commercial kitchen extract systems •Minimum energy efficiency level for all ventilation systems. New build and refurbishment applications for intermittent fans must have an SFP of less than 0.5 W/l/s.

4 As part of the ongoing drive for energy efficiency within Europe, as of January 2016 ventilation devices over 30 Watts now come under the scope of the Energy Related Products Directive. The legislation sets minimum performance criteria across a range of fans and ventilation devices under two sets of legislation; ‘residential’ ventilation and‘non-residential’ ventilation. As a result of the legislation we have reviewed our products and where required made updates to ensure they comply. The primary changes have meant that a number of products have had alternative motors specified or have been updated to enable speed control. However, we have ensured that the installation methods remain unaffected. Through the review we have also taken the opportunity to rationalise our range where needed. All relevant products in this literature have been updated as required by the ErP legislation. Please note that where a product changes due to ErP, there will be a transitional period as we move from the old to the new model, and any stock you currently hold will not be affected by this regulation and can be sold as normal. Residential Products Residential Products has a secondary directive which requires some products to carry an energy label as described below: Residential Ranges – Small fans The majority of small residential fans are unaffected by the legislation as any device below 30 Watts is currently out of scope.The information on them is recorded however and can be found atwww.vent-axia.com/erpThe Duet and Gemini fans have been delisted, but are still available as spares so please contact sales@vent-axia for more information. MVHR and MEV products These products do come into the scope of the legislation and will carry an energy label. There are some minimum energy efficiency requirements as well as the requirement for a summer bypass on heat recovery models. A small number of our products have been updated to ensure they meet these requirements. The following product has been discontinued: •Kinetic E Energy Efficiency Class Products within the scope of ErP now need to carry a rating that shows their Energy Efficiency Class. This information is called a ‘SEC Class’ and is provided in all product literature and on the energy label. A product’s SEC class is affected by how the product is controlled. This is referred to as Local Demand Control (LDC) and indicates how many ‘sensors’ a fan should have. The regulations require that single room fans, such as a bathroom fan, should have at least 1 sensor. Units that are ducted, such as an MEV unit, need to have more than one sensor. Examples of these are a pull cord/light switch or humidistat. In our literature, where appropriate we have shown the rating if an additional LDC was added to a product. In those cases, you will see a table similar to the one below which has a heading (incl LDC). This is so you can choose the most efficient option for your needs. SEC Rating Example Model SEC Class SEC Class (inc. LDC) HR200 C B1 1Manufacturers name1 2Model name1 3Energy Efficiency Class1 4Max flow rate1 5Sound Level2016 1254/2014dB ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIEm 3 /h C Vent-Axia 443028L 66 252 1 3 1 1 1 4 1 5 1 2 Energy Related Products Directive (ErP)

5 Non-Residential Ranges Non-Residential products have had minimum performance and efficiency levels established, but there is no requirement to introduce energy labels. Some products have been updated with new motors and enabled for speed control. Non-Residential ranges are split into a number of different categories dependent on their application and function. These can be describedas follows: 1. Fans 2. Uni-directional Ventilation Units 3. Bi-directional Ventilation Units 1. Fans These are products where there is a simple single case that directs air on and off the impellor. Examples include axial plate and case fans. These examples are out of scope of the legislation.Changes to the way we sell products The ErP regulations gave us the opportunity to review our product ranges and in some cases has enabled us to improve the way we stock and sell them. Examples of this include T-Series and Standard Range fans. You can now buy these as either the entire product or in modular format. The entire product can be purchased using the existing part number that you have always used. Alternatively, you can purchase just the motor core or just the fitting kit as required. If you are unsure of the new part number don’t worry, as we will be able to tell you what the new one is.In some instances however you may receive more than one box.

6 2. Unidirectional ventilation units This includes products that are one direction only, and where thereis a secondary housing around a fan. This is the product category which has required the most changes.The impact of the efficiency legislation has meant that it has become virtually impossible to comply using a forward curved AC centrifugal fan. We have therefore moved to backward curved centrifugal fans in all of our AC box fan ranges. This has meant changes to the box sizes and adjustment to performances across the range. The product ranges have therefore been updated: ACQ/ATQQP/QPTWWe have a number of product ranges that have been reaching the end of their life cycle and we have taken the opportunity to rationalise these and where possible provide a suitable alternative range. The following product ranges are no longer available: VMD RMV GRB GDB GRD Other product ranges have been rationalised to provide one solution, these include: ARH – rationalised to MFQ RBH – rationalised to RMH 3. Bi-directional ventilation unitsThese are product ranges that both supply and extract such as heat recovery. There are now minimum energy requirements set for heat recovery efficiency.Any product with an efficiency of 67% or lower does not comply. Both the Totus 2and ERV-HIBOX ranges are unaffected by thesechanges, however the low efficiency heat recovery ERV-BOX products have been discontinued. Heat recovery minimum efficiency 67% 67% Energy Related Products Directive (ErP)

7 Things have moved on a bit since 1992 when ventilation was first introduced into the Building Regulations. Here is an overview of the changes from 2006.2006 – Part F included continuous ventilation for the first time.Ventilation systems were being installed by skilled persons but the performance data was never tested. Part L changes meant that SAP Q products could be included as part of the dwelling’s SAP calculations. 2010 – Design, install and ensure its used correctly. With dwellings being designed with increased energy efficiency and reduced air permeability, ventilation systems now require specific flow rates and there is more demand for highly efficient heat recovery to help reduce the DER’s. Ventilation is now required to be installed correctly with the installation recorded and measured plus there needs to be guidance to the home occupier as to how it operates. 2013 – New Part L requirements meant a reduction in air leakage and increased air tightness.These trends continue to drive the adoption of higher efficiencies and the importance of installation increases as the advantageous air from leakage is reducing further.2016 –With the commitments made in the recent COP21 meeting and the Paris climate agreement, focus on decarbonisation and energy efficiency is set to continue. The Energy Performance of Buildings directive and the Energy related Product Directive are having an impact on the performance and efficiency standards of ventilation. These drivers will continue to develop and are expected to transform into standards in the future meaning an even greater focus on energy efficiency. The commitment to zero carbon buildings in 2019 will mean revisions to Part F and L of the building regulations are likely. As we focus our efforts to drive down the energy that we use in buildings, the risk of airtight, well insulated buildings being the potential cause of respiratory problems increase. Therefore the importance of well-designed and well installed systems that perform as designed increases. This will lead to increased focus on competence when installing ventilation and is likely to drive advances in the way installers are trained. Things to Remember •Airflow performance •Minimum energy efficiency limits •Good installation •Use by occupiers Future Direction

8 LO-CARBON RESIDENTIAL FANS12-35 Lo-CarbonSvara- Up to 30l/s Lo-Carbon iQ- Up to 37l/sContinuous Running Lo-CarbonVA100 ® /SELV - Up to 21l/s Lo-CarbonSilhouette ®100/SELV - Up to 30l/s Lo-Carbon Centra ® /SELV - Up to 15l/sContinuous Running NEW Lo-CarbonRevive/SELV - Up to 60l/s Lo-Carbon Solo ® Plus/SELV- Up to 21l/sContinuous Running Page 14-15 Page 16-17 Page 18-19 Page 20-21 Page 22-23 Page 24-25 Page 26-27 Lo-CarbonMinivent- Up to 31l/s Lo-Carbon LEDVent-A-light- Up to 31l/s Lo-Carbon Quadra ® /SELV - Up to 63l/s Continuous Running Lo-Carbon Silhouette 125- Up to 44l/s Lo-Carbon VA150- Up to 64l/s Lo-CarbonSilhouette ®150 - Up to 65l/s Page 28 Page 29 Page 30-31 Page 32 Page 33 Page 34-35 dMEV, MEV & PIV SYSTEMS36-55 Lo-Carbon Centra ® /SELV - Up to 15l/s (54m 3 /h)Continuous Running Lo-Carbon Response- Up to 13l/s (47m 3 /h)Continuous Running Lo-Carbon Multivent- Up to 120l/s(432m 3 /h) Multivent- Up to 123l/s(443m 3 /h)Lo-Carbon Sentinel ®Multivent/Plus - Up to 165l/s (595m 3 /h) Lo-Carbon MultiventMVDC-MS/MSH- Up to 121l/s(436m 3 /h) Page 38-39 Page 40-41 Page 42-43 Page 44-45 Page 46-49 Page 50-51 Lo-Carbon PoziDry- Up to 50l/s (180m 3 /h) Lo-Carbon PoziDry Compact- Up to 34l/s (122m 3 /h) Page 52-53 Page 54-55 SINGLE ROOM dMVHR56-63 Lo-CarbonTempra/SELV- Up to 15l/s (54m 3 /h)Continuous Running HR200WK- Up to 61l/s (220m 3 /h) HR300- Up to 83l/s (299m 3 /h) Page 58-59 Page 60-61 Page 62-63 Contents

9 MVHR UNITS FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 64-115 Lo-Carbon Sentinel Kinetic ®Advance- Up to 115l/s (414m 3 /h) Page 66-67 Lo-Carbon Sentinel Kinetic ® - Up to 76l/s (274m 3 /h) Page 72-75 Lo-Carbon Sentinel Kinetic ®FH - Up to 93l/s (335m 3 /h) Page 76-79 Lo-Carbon Sentinel Kinetic ®Plus - Up to 136l/s (490m 3 /h) Page 80-83 Lo-Carbon Sentinel Kinetic ®High Flow - Up to 195l/s (702m 3 /h) Page 84-85 Lo-Carbon Sentinel Kinetic ®Cooker Hood - Up to 76l/s (274m 3 /h) Page 86-89 Lo-Carbon Sentinel Kinetic ®Horizontal- Up to 98l/s (353m 3 /h) Page 90-95 Lo-CarbonKinetic ®Plus E - Up to 141l/s (508m 3 /h) Page 96-99 Integra ® - Up to 48l/s (173m 3 /h) Page 100-101 NEW Integra ®Plus EC - Up to 130l/s (54m 3 /h) Page 102-103 HR100R/RS- Up to 18l/s (65m 3 /h) Page 104-105 HR200V- Up to 103l/s (371m 3 /h) Page 106-107 HR500- Up to 250l/s (900m 3 /h) Page 108-109 HR500D- Up to 174l/s (626m 3 /h) Page 110-111 HR500EP/IP- Up to 244l/s (878m 3 /h) Page 112-113 HR500DP- Up to 333l/s (1,199m 3 /h) Page 114-115 DUCTING & FITTINGS116-141 HEATING RANGE142-161 Bluethermal ®UnderfloorHeating- Up to 3,300W Page 144-149 Heated Towel Rails- Up to 400W Page 150-151 Radiant Heaters- Up to 6,000W Page 152-153 Opal ® Aluminium Radiators - Up to 1,500W Page 154 Optimax ®PlusPanel Heaters- Up to 2,000W Page 155 Optimax ®Plus CombinationStorage Heaters- Up to 3,400W Page 156 Optimax ®PlusStorage Heaters- Up to 3,400W Page 157 Plinth Heaters- Up to 2,000W Page 158 Warm Air Curtains- Up to 6,000W Page 159 Convector Heater- Up to 2,000W Page 160 Portable Fan Heater- Up to 2,000W Page 161

10 Contents COMMERCIAL RANGE162-205 ACM ®100 - 200 - Up to 240l/s (864m 3 /h) Page 164-165 ACM ®250 - 315 - Up to 653l/s (2,351m 3 /h) Page 166-167 Powerflow- Up to 340l/s (1,220m 3 /h) Page 168-169 Lo-Carbon T-Series ® Window Model- Up to 430l/s (1,550m 3 /h) Page 172-173 Lo-Carbon T-Series ® Wall Model- Up to 460l/s (1,650m 3 /h) Page 174-175 Lo-Carbon T-Series ®Roof Model- Up to 330l/s (1,194m 3 /h) Page 176-177 Lo-Carbon T-Series ® Panel Model- Up to 490l/s (1,761m 3 /h) Page 178-179 Traditional T-Series ® Window Model- Up to 449l/s (1,615m 3 /h) Page 182-183 Traditional T-Series ®Wall Model- Up to 485l/s (1,745m 3 /h) Page 184-185 Traditional T-Series ®Roof Model- Up to 412l/s (1,485m 3 /h) Page 186-187 Traditional T-Series ® Panel Model- Up to 524l/s (1,885m 3 /h) Page 188-189 Traditional T-Series ® Darkroom Model- Up to 314l/s (1,130m 3 /h) Page 190-191 Traditional T-Series ® Inline Model- Up to 620l/s (2,230m 3 /h) Page 192-193 Super T-Series- Up to 1372l/s (4,940m 3 /h) Page 194-195 Traditional StandardWindow Model- Up to 433l/s (1,560m 3 /h) Page 198-199 Traditional StandardRoof Model- Up to 314l/s (1,130m 3 /h) Page 200-201 Traditional StandardWall Model- Up to 491l/s (1,767m 3 /h) Page 202-203 Traditional StandardPanel Model- Up to 531l/s(1,910m 3 /h) Page 204-205 ACCESSORIES & CONTROLLERS - RESIDENTIAL & LIGHT COMMERCIAL SYSTEMS206-225 PLATE & CASE FAN RANGE226-301 Sabre Plate Mounted Sickle Fans (VSP)- Up to 5.71m 3 /s(20,556m 3 /hr) Page 228-233 Sabre Sickle Short Case Fans (VSC)- Up to 5.81m 3 /s(20,916m 3 /hr) Page 234-241 Long Case Axial Fans (LCA)- Up to 36.01m 3 /s(129,600m 3 /hr) Page 242-271 Kitchen Axial Fans (KAF)- Up to 5.93m 3 /s(21,348m 3 /hr) Page 272-275 Bifurcated Case Axial Fans (BIFA)- Up to 19.10m 3 /s(68,760m 3 /hr) Page 276-301

11 IN-LINE FAN RANGE302-341 Lo-Carbon Kitchen Box Fan (EKF)- Up to 3.69m 3 /s(13,284m 3 /hr) Page 304-311 NEW Acoustic In-Line Fans (ACQ)- Up to 1.5m 3 /s(5,400m 3 /hr) Page 312-317 Eco Mix Flow Fans (eMF)- Up to 5.63m 3 /s(20,268m 3 /hr) Page 318-323 Powerflow In-Line Duct Fans (ACP)- Up to 0.34m 3 /s(1,220m 3 /hr) Page 324-327 EuroSeries ®(SDX) In- Line Centrifugal Fans- Up to 0.35m 3 /s(1260m 3 /hr) Page 328-331 Slimpak® In-Line Centrifugal Fans (SLP)- Up to 0.38m 3 /s(1,368m 3 /hr) Page 332-335 Mixed Flow Fans (MFQ) - Up to 3.67m 3 /s(13,212m 3 /hr) Page 336-341 TWIN FAN RANGE342-355 SENTINEL D-BOX356-383 New Acoustic In-Line Direct Driven Twin Fans (ATQ)- Up to 1.35m 3 /s(4,860m 3 /hr) Page 344-349 Power Twin Fans (TDF)- Up to 3.52m 3 /s(12,672m 3 /hr) Page 350-353 Trakmaster Twin Fan Controllers Page 354-355 Sentinel D-Box Single Fan- Up to 1.49m 3 /s(5,364m 3 /hr) Page 362-371 Sentinel D-Box Twin Fan- Up to 1.20m 3 /s(4,320m 3 /hr) Page 372-381 Sentinel D-Box Sensors& Controls Page 382-383 SENTINEL TOTUS 2D-ERV384-401 ROOF FAN RANGE 402-425 Sentinel Totus 2D-ERV Fans - Up to 0.59m 3 /s(2,124m 3 /hr) Page 396-401 NEW High Temperature Roof Fans (RDM)- Up to 8.83m 3 /s(31,788m 3 /hr) Page 404-407 Sabre® Sickle fan assisted roof cowl (VSR)- Up to 5.00m 3 /s(18,000m 3 /hr) Page 408-415 Mixed Flow Roof Fans (RMH)- Up to 3.63m 3 /s(13,068m 3 /hr) Page 416-421 Lo-Carbon MX Roof Fans (MX)- Up to 1.86m 3 /s(6,696m 3 /hr) Page 422-425 AIR HANDLING 426-435 ACCESSORIES & CONTROLLERS NON-RESIDENTIAL436-463 Slimline Range (SL)- Up to 0.92m 3 /s(3,312m 3 /hr) Page 428-431 D1 to D6Mini Direct Range - Up to 2.25m 3 /s(8,100m 3 /hr) Page 432-435

Lo-CarbonResidential Fans Continuing our commitment to energy efficiency in this section you will find Lo-Carbon solutions for intermittent and continuous fan applications. In axial or centrifugal, wall, ceiling or window applications in bathrooms or kitchens we have a Lo-Carbon fan offering up to 90% energy saving over the equivalent traditional fan. We are proud to be market leaders and continually strive to bring you the best products available. Our newest addition to the range is no different - the NEW Lo-Carbon Revive features a raft of innovations developed specifically for the needs of the Social Housing Market. The unique Multi-Vortex TMairflow technology ensures excellent pressure development yet efficient and quiet operation. Revive’s Sense Smart TMintelligent technologymakes the fan easy to install and provides a range of data via its easy to use interface.See page 24 for more details.

NEW Lo-Carbon Svara Axial Bathroom/Toilet Fan 30 4 20 0.13 14-15 Lo-Carbon iQ Intelligent Axial Bathroom Fan 37 - 29 - 16-17 Lo-Carbon VA100 ® /SELVAxial Bathroom/Toilet Fan 21 7 36 0.33 18-19 Lo-Carbon Silhouette ®100/SELVBathroom/Toilet Fan 30 8.7 38 0.30 20-21 Lo-Carbon Centra ® /SELVdMEV Unit 15 2.4 25.2 0.18 22-23 NEW Lo-Carbon Revive /SELVBathroom/Kitchen Filterless Fan 24-25 Lo-Carbon Solo Plus/SELVCentrifugal Bathroom/Toilet Fan 21 8.4 35.5 0.29 26-27 Lo-Carbon MiniventDucted Bath/Shower Fan Kit 31 6.5 23 0.21 28 Lo-Carbon LED Vent-A-lightDucted Bath/Shower Fan Kit 31 6.5 23 0.21 29 Lo-Carbon Quadra ® /SELVCentrifugal Fan 63 38 50 0.60 30-31 Lo-Carbon Silhouette ®125Bathroom/Toilet Fan 44 8 37 0.18 32 Lo-Carbon VA150Axial Kitchen & Utility Room Fan 64 36 11.5 0.18 33 Lo-Carbon Silhouette ®150Axial Kitchen Fan 34-35

14 The UKs first App controlled unitary fan The launch of Svara marks the next generation of unitary fans.For electricians, installation is made simple through Svara’s Bluetooth-enabled App allowing you to choose whether to opt for intermittent or continuous ventilation; whether you would like the humidistat to trigger operation or not; and whether the overrun timer is required. No more fiddly switches and jumpers!For consumers Svara offers improved comfort in their homes since it has been developed to allow households to take control of their indoor air quality via the App. Aesthetics and silence The name Svara takes its influence from the fan’s Swedish heritage – a country well known for iconic and well thought out designs.Consumers willbe attracted to Svara’s good looks with its sleek modern design, plus with noise a key issue for consumers, households will also be impressed by Svara’s quiet running, operating at just 17 dBA on low trickle. It is also easy to clean as the central module disconnects the motor from the rest of the fan allowing it to be simply wiped with a soft cloth, and at only 4W the energy efficient Svara also boasts low power consumption. One model fits allVent-Axia Svara is programmed to cope with the vast majority of installations.The fan is set as default to work continuously at a trickle flow of 10l/s. When the fan senses a somebody in the room it increases the flow to 19l/s. If the humidity rises rapidly, for example when the shower is on, the fan goes up to maximum flow at 30l/s. When the fan senses the humidity level has returned to normal it reverts to the trickle flow of 10l/s. If other settings or functions are desired, they can be selected through the Vent-Axia Connect App which can be downloaded from the App Store and Google Play. FunctionsLight sensorWhen the light sensor is enabled Svara senses when someone is in the room and then activates.Its sophisticated light sensor is triggered by light movement and shadows. It is possible to set a delay-on so the fan is not triggered by the light during quick night time bathroom visits. The light sensor can also distinguish between headlight flashes from cars and room occupancy, so it is not triggered by passing cars, avoiding nuisance running. The sensitivity of the light sensor can be adjusted via the App. Overrun TimerThe light sensor provides an overrun timer but only requires a live and neutral. In houses where there isonly a basic fan installed, the home owner can upgrade to a timer fan without having to rewire.HumidistatSvara features a humidistat which reacts to sharp changes in humidity, for instance when someone is taking a shower. When set to continuous running, once the humidity sensor is activated the fan runs at 30l/s until humidity returns to normal levels then the fan powers down to 10l/s. Ambient humidity changes will not trigger the humidistat. It is possible to change the sensitivity of the humidity sensorvia the App.Silent scheduling and Automatic cyclesThe silent hours scheduling function allows you to deactivate the boost function on the Svara via the App, for example, this would prevent nuisance noise over night. Additionally during a vacation you can set Svara to an airing mode which operates a purge function every 12 hours for either 30, 60 or 90 minutes depending on selection. However, Svara’s sophisticated controls, will not purge if the light sensor detects that there is someone in the house. NEW Lo-Carbon Svara •The UK’s first App controlled unitary fan! •Set up and control through the App via Bluetooth •Continuous or intermittent •1 model for all applications •Silent hours scheduling and purge mode functions •Intelligent light sensor with overrun timer - allows replacement of a basicmodel fan •3 Speed, IP44 Rated, DC motor with 5 year guarantee •Suitable for ceiling, panel or wall mounting•Only 17 dBA

15 Models Svara kitchen and bathroom fan100 mm Axial fan. Factory set at continuous running with Humidistat and Light Sensor/overrun timer On. ModelStock Ref£Trade Lo-Carbon Svara409802205.09 Accessories ModelStock Ref£Trade Wall Kit 25410221.55 ModelStock Ref£Trade Back draught shutter40660519.46 Cover plateFor duct dimensions between Ø140-160mmModelStock Ref£Trade Cover plate40982015.67 Dimensions (mm)A B C D A B CØ DØ 60 21 99 177 Performance Guide Extract Performance - FID (l/s) Sound dB(A)SFP (W/l/s)Low Trickle High Trickle Boost Max Watts @ 3m @ 0Pa 10 16 30 4 17-20 0.13

16 Lo-Carbon iQ •Minimal retro design to match bathroom décor •Extremely quiet- only 21 dB(A) •Truly surface mountable with removable spigots •Intelligent controls and control panel for easy and flexible set upand commissioning•Low power consumption – only 5 W •Easy cleaning and maintenance •5 year Lo-carbon motor guarantee •Intelligent humidistat control as standard •Innovative airing function to ensure good air quality •IP44 rated Market Leading Design With the launch of the Lo-Carbon iQ fan, we not only spent time perfecting the operation and user’s experience of the fan but also worked hard on the design. The result is a stylish fan with a surface depth that appeals to the eye and that matches modern fittings found in today’s bathrooms. The visible blades give a retro-feel and helps to give the fan a very quiet noise level. Silent Operation The open impellor and the unique method of operating the motor enables a greater array of operating options including silent continuous ventilation along with adaptable speed control and flexible timer functions.Humidity Control The iQ features an intelligent, fully automatic humidity sensor for moisture control. This means the fan learns to run only when it can make a difference to the indoor air quality. The fan continually monitors and records the moisture content to allow it to map the humidity profile throughout the year. This process enables the fan to ensure that it runs only when the fan can lower the moisture content in the air. This reduces nuisance running. The fan also has two modes for moisture control, silent or boost mode which can be selected via the touch pad control. Control Panel Our aim has been for the end user to be able to control and understand the basic fan functions, without the need of reading the manual. When the fan is connected to the power supply, it also performs a self-test where all the status lamps on the control panel are tested, as well as the function of the motor. Ideal for those installing to ensure that everything works. The simple controls, along with the LED feedback make the commissioning and any readjustment, quick and easy to complete. LED Feedback With many fans it is difficult to understand the exact mode that they are running in. We have now simplified this to provide a visual indicator to see what the fan is doing and which mode is currently active. The fan uses three different colours on the visible status lamp to communicate exactly what it is doing. A blue light signifies that the fan is working to evacuate moisture via the humidity sensor. A yellow light signifies that the timer is running. And a purple light signifies that the fully automatic airing function is active. You Choose How The Fan Works The intelligent overrun timer can be operated in several different ways, either via the light switch, integral pull-cord or a separate switch either as a standard On/Off or as a momentary switch stopping automatically after the overrun on time. You use the control panel to easily set the required post-running time at 15 or 30 minutes, depending on your choice. Full Surface Mounted Installation With the impellor and motor assembly designed to be low profile and accessible for maintenance, spigots on the fan are completely removable. This design enables the fan to be mounted onto a wall without any spigot so that it can be truly surface mounted. This is an ideal function if you have a duct with a smaller dimension than 100 mm or a duct that bends directly off of the back of the fan not providing any depth in the wall for the spigot. Cleaning and Maintenance For a fan to ventilate effectively, it is vital that it is kept clean and that the ductwork and grilles are free from dust that can reduce the air flowing through them. This is the first fan to be introduced with the ability to simply remove the impellor and open the centre of the fan to gain free access to the duct. Using the ‘swing-out’ function you can easily clean and clear the fan e.g. a clogged grille on the outside of the façade. Click the button to remove the impellor, then press the snap in catch and swing out the motor - that’s it!

17 Automatic Airing Function The airing function means when the fan has been inactive for 26 hours, it runs an airing programme for 60 minutes to exchange the air in the bathroom. No more worries about stuffy, musty odours in the bathroom when returning from holiday. Lo-Carbon 5 Year Guarantee As there is an integrated power adapter in the fan we have been able to use a low voltage motor that has a life span of approximately 60,000 hours. This is about 3-5 times longer than a standard fan. The motor features extremely quiet bearings. By using a low voltage motor we can significantly limit power consumption. The fan only consumes 5 Watts, about a third of a conventional AC bathroom fan. Models Lo-Carbon iQ Multi control fan with option to run on intermittent or continuous setting. Adjustable timer and humidity options with integral pullcord included.ModelStock Ref£Trade Lo-Carbon iQ405155205.09 Accessories Backdraught ShuttersDesigned to reduce any incoming draughts when the fan is off.ModelStock Ref£Trade Backdraught Shutters40660519.46 Wall Mounting Back PlateDesigned to cover up marks where a previous fan has a different foot print. 242mm x 190mm.ModelStock Ref£Trade Wall Mounting Back Plate40676220.29 Dimensions (mm) DØ A B CA B C DØ 152 202 31 99/125 Product is supplied with a removable spigot 30mm deep in 99mmØ and 125mm Ø PerformanceExtract Performance - FID Sound dB(A)Duct Ø Trickle/Boost m 3 /hl/s @ 3m 100mm Max 108 30 28 100mm Silent 72 20 21 100mm Trickle 43.2 12 12 125mm Max 133.2 37 29 125mm Silent 86.4 24 21 125mm Trickle 54 15 13

18 Long Life Ventilation VA100 The Vent-Axia Lo-Carbon VA100 range features Lo-Carbon long life DC motors that are more efficient than conventional motors delivering up to 87% energy savings. Shutters The Vent-Axia Lo-Carbon VA100 range is fitted with a motorised shutter mechanism that uses no extra power in operation or off. Installation Fitted with integral protection against low energy lighting circuits, the Lo-Carbon VA100 is a 100mm axial fan suitable for use in the bathroom or toilet. VA100 is quick and simple to fit with easy-wire in one line terminals. Suitable for installation in windows, walls or panels/ceilings using kits available. The 100mm telescopic wall kit fits walls 225 to 360mm thick. The range meets the requirements of the current Building Regulations for the ventilation of toilets6l/s and bathrooms 15l/s with a 15 minute overrun timer for internal rooms on the LT, XT and HTP models. Safety Extra Low Voltage (SELV) Fan Safety Extra Low Voltage (SELV) is designed for areas where a fan has to be fitted within zone 1 in a room containing a fixed bath or shower according to IEE wiring regulations. The VA100 SELV can be safely installed within the spray area. The fan is rated IPX7, control is by the supplied mains safety isolating transformer with 12V DC SELV output, which is sited away from any source of spray and out of reach of a person using a fixed bath or shower. Models Lo-Carbon VA100 LP/SELV LP (Pullcord) Ultra long life DC motor. Pullcord On/Off override switch with indication light. 2 speed options.ModelStock Ref£Trade LP44315961.69 SELV LP441614131.21 Lo-Carbon VA100 XP/SELV XP(Shutter/Pullcord) Ultra long life DC motor. Pullcord and On/Off override switch with indication light. 2 speed options.ModelStock Ref£TradeXP44316084.98 SELV XP459049144.70 Lo-Carbon VA100 LT/SELV LT (Timer) Electronic adjustable overrun timer (5-30 minutes). Indication light. 2 speed options.ModelStock Ref£Trade LT44316176.22 SELV LT441615140.36 Lo-Carbon VA100 XT/SELV XT (Shutter/Timer) Integral electronic adjustable overrun timer (5-30 minutes). Indication light. 2 speed options.ModelStock Ref£Trade XT443162112.41 SELV XT459050 171.93 Lo-Carbon VA100 LHTP/SELV LHTP(Integral Humidity Sensor/Pullcord/Timer)Complete with integral humidity control with pullcord override. Indication light which operates on the manual override only. 2 speed options.ModelStock Ref£Trade LHTP443163195.76 SELV LHTP441616225.81 Lo-Carbon VA100 XHTP/SELV XHTP (Shutter/Integral Humidity Sensor/Pullcord/Timer) Complete with integral humidity control with pullcord override. Indication light which operates on the manual override only. IPX4 rated. 2 speed options.ModelStock Ref£Trade XHTP443164208.69 SELV XHTP436064240.15 Lo-Carbon VA100/SELV •Meets current Building Regulations Approved Document F & L•Suitable for wall, ceiling, panel and window mounting •Fitted with a motorised shutter •Protected against low energy lighting circuits•IPX4 rated - IPX7 rated (SELV)•Efficient long life DC motor with 5 year guarantee •Uses up to 87% less energy •Low sound levels •1 of 2 speeds selectable at installation•Low specific fan power •Day logger as standard on all models

19 Accessories Wall KitFixing hole diameter 117mmØ ModelStock Ref£Trade Wall Kit White25410221.55 Wall Kit Brown25410021.55 Window Kit Fixing hole diameter 105mmØModelStock Ref£Trade Window Kit25410121.55 Anti-tamper Window Kit44323423.32 Dimensions (mm)A A A B C DØ E F G H H Panel Wall Window A B C DØ E F G H Bathroom/Toilet 146 47 53 98 31 31 74 200 SELV Transformer (W x H x D) 87 x 87 x 33 Weight 1kg PerformanceExtract Performance - FID Sound dB(A)SFP (W/l/s)AreaModels m 3 /hl/s Watts @ 3m @ 0Pa Toilet Lo-Carbon VA100/SELV LP/XP/LHTP/XHTP/LT/XT 60 17 3.4 32 0.20 Bathrooms Lo-Carbon VA100/SELV LP/XP/LHTP/XHTP/LT/XT 74 21 7.0 36 0.33

20 Lo-Carbon Silhouette 100/SELV •Models Basic/Timer/Humidity & Timer •Low power consumption - Lower running costs •Fully opening and closing non-transparent shutters - Improvedinsulation and privacy •Meets current Building Regulations Approved Document F & L •1 of 2 speeds selectable at installation •Blue power indication light (except B model) - Modern aesthetics •Ball bearing motors for vertical or horizontal application •Unique humidity sensor track - Improved response •5 Year Motor Guarantee•IPX4 rated - IPX7 rated (SELV) •Suitable for wall, ceiling, panel and window mountingSlimline Bathroom Ventilation With a slim profile of only 17mm, Lo-Carbon Silhouette blends in with the wall surface to provide an unobtrusive installation. Lo-Carbon Silhouette has an FID performance of up to 30l/s. It can be ceiling/panel mounted and connected to an appropriate duct run to the outside. Safety Extra Low Voltage (SELV) Fan Safety Extra Low Voltage (SELV) is designed for areas where a fan has to be fitted within zone 1 in a room containing a fixed bath or shower according to IEE wiring regulations. The Silhouette SELV can be safely installed within the spray area. The fan is rated IPX7, control is by the supplied mains safety isolating transformer with 12V DC SELV output, which is sited away from any source of spray and out of reach of a person using a fixed bath or shower. SELV transformer to BS EN 60742. Models Lo-Carbon Silhouette 100B/SELV 100SVB100mm bathroom/toilet fan with back draught shutter.ModelStock Ref£Trade 100B441624 61.04SELV 100SVB441511 118.99Lo-Carbon Silhouette 100T/ SELV 100SVT (Timer)100mm bathroom/toilet fan with integral adjustable electronic overrun timer (5-30 minutes), indicator light which operates on manual override only, and back draught shutter.ModelStock Ref£Trade 100T441625 76.28 SELV 100SVT441512 144.95Lo-Carbon Silhouette 100HT (Humidistat/Timer) 100mm bathroom/toilet fan with adjustable auto humidity sensor from 60-90% RH and overrun timer, indicator light which operates on manual override only, and back draught shutter. Datalogger as standard on all Lo-Carbon humidity controlled Silhouette fans. ModelStock Ref£Trade 100HT441626 126.64 Lo-Carbon Silhouette 100H SELV(Humidistat)100mm bathroom/toilet fan with ambient response humidity sensor from 60-90% RH, indicator light which operates on manual override only, and back draught shutter.Safety Extra Low Voltage version.ModelStock Ref£Trade SELV 100SVH441513 195.27 Accessories Wall KitFixing hole diameter 117mmØ ModelStock Ref£Trade Wall Kit White25410221.55 Wall Kit Brown25410021.55 Window KitFixing hole diameter 117mmØModelStock Ref£Trade WindowKit44294723.32 17mm actual profile

21 Dimensions (mm) PanelWall KitA A ØB C D E F EA BØ C D E F 160 99 115 132 200 32 SELV Transformer (W X H X D) 87 X 87 X 33Weight 0.6kg Performance Guide 0 5 10 15 20 25 0 5 10 15 20 30 Air Volume l/s Pressure Pa 30 35 25 35 1 2Extract Performance - FID Sound dB(A)SFP (W/l/s)Area Model Curve Ref m 3 /hl/s Watts @ 3m @ 0Pa Toilet Lo-Carbon Silhouette 100 B/T/HT/SVB/SVT/SVH 1 60 17 3.4 34 0.20 Bathrooms 2 108 30 8.7 38 0.30 For window mounting: shutter cannot be used and must be removed

22 Lo-Carbon Centra/SELV •Building Regulations Approved Documents F and L compliant,System 3 Continuous mechanical extract •Recognised in SAP PCDB - Low SFP •Discreet, tasteful styling •IPX4 rated - IPX7 rated (SELV) •dMEV Pressure detection device •5 Year Motor Guarantee •Suitable for wall, ceiling, panel and window mounting •SELV models supplied with remote transformer and suitablefor ‘Zone 1’ What is de-centralised MEV (dMEV)? Building Regulations Approved Document F gives examples of four main methods of ventilation. System 3, Continuous mechanical extract ventilation, can be achieved using a single centralised extract unit such as the Sentinel Multivent ducted to ‘wet’ rooms (kitchen, bathroom, en-suite and WC) or by decentralised individual fans, such as the Lo-Carbon Centra in the ‘wet’ rooms. The fans run continuously at near silent levels providing a simple and effective form of ventilation. SELV (Safety Extra Low Voltage) is designed for areas where a fan can be installed within Zone 1 in a room where there is a fixed bath or shower. Ingress Protected (IP) to IPX7 Lo-Carbon Centra SELV can be fitted safely within the spray area. The separate transformer can be mounted away from the spray zone and out of reach from the bathor shower. The Lo-Carbon Centra meets the latest requirements of the Building Regulations Approved Document F for wholehouse system ventilation and all models come with a 5 year motor guarantee. Selection of the two trickle flow rates (6l/s or 9l/s) is via a simple ‘jumper’ on the control board. Different methods are available for operating the 15 l/s boost speed from a simple switched live to integral humidistat. See individual models for further details. The attractive and discreet styling of the Vent-Axia Lo-Carbon Centra will complement the décor of any new home while virtually silent operation ensures optimum ventilation is achieved without intrusive noise. Specific Fan Power dMEV version recognised in SAP PCDB. Lo-Carbon Centra has a specific fan power of only 0.18 W/l/s in through-the-wall kitchen applications. Models Lo-Carbon Centra dMEV Auto speed selection at installation and suitable for bathrooms or kitchens. The integral air pressure sensor checks the airflow when first installed and also helps the fan to compensate for external wind pressure. Stock Ref £Trade 441782 123.19 Lo-Carbon Centra T/SELV T (Timer)Ideal for bathroom and toilet applications, this unit runs continuously on trickle setting and may be boosted by the switched live input which activates the timer (fixed 15 min on T models, adjustable 5-30 minutes on SELV models).ModelStock Ref£Trade T442954139.62 SELV T443175 171.28 Lo-Carbon Centra TP/SELV TP (Timer/Pullcord)For bathroom/toilet applications, the continuous running TP model is boosted by the pullcord which activates the timer (fixed 15 min on TP models, adjustable 5-30 minutes on SELV models).ModelStock Ref£Trade TP447127 156.68 SELV TP 447128187.67 Lo-Carbon Centra HT/SELV HT (Humidistat/Timer)For bathroom/toilet applications, the continuous running HT model is automatically boosted by the built-in humidistat or by a switched live input which activates the timer (fixed 15 min on HP models, adjustable 5-30 minutes on SELV models). ModelStock Ref£Trade HT442955 182.51 SELV HT443176 214.44 Lo-Carbon Centra HTP/SELV HTP(Humidistat/Timer/Pullcord)For bathroom/toilet applications, the continuous running HTP model is automatically boosted by the built-in humidistat or by the pullcord which activates the timer (fixed 15 min on HTP models, adjustable 5-30 minutes on SELV models). ModelStock Ref£Trade HTP443045 182.51 SELV HTP 443177214.44 WINNER 2011 Winners of the Energy Efficiency Initiative 2011 Awardwith our Lo-Carbon Continuous Ventilation Product Range

23 Accessories ModelStock Ref£Trade 150mm Conversion Kit44333428.65 Wall Kit White25410221.55 Wall Kit Brown25410021.55 Window Kit44294723.32 Ceiling Kit44380015.84 Dimensions (mm) DØ A A B C Model A B C DØ Lo-Carbon Centra dMEV/All SELV 160 35 115 99 Lo-Carbon Centra T/TP/HT/HTP 160 35 80 99 Transformer 87 x 87 x 33mm (W x H x D) (SELV models only) Performance Guide Extract Performance (l/s) Power Consumption (Watts) Sound dB(A)@ 3m Trickle TrickleTrickle TrickleTrickle TrickleModel Low High Boost Low High Boost Low High Boost Lo-Carbon Centra dMEV/All SELV 6 9 15 1.4 1.6 2.4 10.8 15.5 25.2 Lo-Carbon Centra T/TP/HT/HTP 6 9 15 3.2 3.5 4.2 10.8 15.5 25.2 SAP PCDB Performance (dMEV model) Systems With Rigid Ductwork Installation Only Unit Configuration Location Fan Speed Setting Flow Rate (l/s) SFP (W/l/s) In Room (Ducted) KitchenHigh 13.2 0.32 In Room (Ducted) Wet Room 9 l/s 8.4 0.28 Through Wall KitchenHigh 13.5 0.18 Through Wall Wet Room 9 l/s 8.6 0.20 Systems With Flexible Or Mixed Ductwork Installation Only Unit Configuration Location Fan Speed Setting Flow Rate (l/s) SFP (W/l/s) In Room (Ducted) KitchenHigh 13.2 0.37 In Room (Ducted) Wet Room 9 l/s 8.6 0.31 Through Wall KitchenHigh 13.5 0.18 Through Wall Wet Room 9 l/s 8.6 0.20

24 NEW Lo-Carbon Revive/SELV •Designed specifically with Social Housing in mind •Continuous running bathroom and kitchen fan •Extracts up to 60l/s •Easy to read LED display for commissioning and datagathering •Intelligent Smart Sense TMtechnology tells you daysrun, boost hours run, energy used •Innovative Multi-Vortex technology ensure highperformance but low sound and energy levels •5 or 7 year warranty options •Small footprint with optional decoration frame Designed for Social Housing The intelligent Lo-Carbon Revive is a new filter-less unitary fan designed to meet the specific needs of social housing. Boasting powerful, quiet, efficient ventilation, Revive provides good indoor air quality and comfort for residents while being quick and easy to install, low maintenance and reliable.Smart Sense TMtechnology Featuring Smart Sense™ intelligent technology Revive is quick and easy to install due to its simple alpha numeric LED display which is clear, easy to read and has a three-button menu for commissioning and data gathering. Smart Sense™ technology even tells the LED display which orientation to use depending on whether it is wall or ceiling mounted. All of which saves time on site and reduces installation complications. The display also shows real-time data so landlords can reassure residents of the low-running costs. This includes data such as days run, hours on trickle or boost, and even more specifically, hours run on boost triggered by the humidity sensor. Revive can also tell you how much energy the fan has used. Multi-Vortex TMtechnology Revive is low maintenance since its market-leading Multi-Vortex™ technology does not require a filter, while the highly sculpted interior actively repels dust, avoiding clogging, thus helping to avoid call backs. In addition the Multi-Vortex TM technology has a high-pressure hybrid impellor that is powerful and efficient, yet quiet – everything you need for the Social Housing resident. Multiple configuration options Revive can extract up to 60l/s from a kitchen, but upon installation you have the choice to change the setting to allow for installation in a bathroom. The installer can also select a ducted mode or a through the wall mode. All selected via the intuitive LED display. Models Lo-Carbon Revive 7/SELV 7HTP continuous running fan with kitchen or bathroom setting, with a combination of trickle and boost speeds selectable from 9, 15, 30 and 60l/s. Day logger and power run meter as standard. 7 year warranty. Adjustable dynamic ambient response humidity sensor. Timer adjustable between 1 and 30 minutes. In built boost activated by pullcord, humidity sensor, switched live or remote button. Tile front for discreet installation.ModelStock Ref£Trade Lo-Carbon Revive 7473848328.39 Lo-Carbon Revive SELV 7473849377.29 Lo-Carbon Revive 5/SELV 5HTP continuous running fan with kitchen or bathroom setting, with a combination of trickle and boost speeds selectable from 9, 15, 30 and 60l/s. Day logger and power run meter as standard. 5 year warranty. Adjustable dynamic ambient response humidity sensor. Timer adjustable between 1 and 30 minutes. In built boost activated by pullcord, humidity sensor, switched live or remote button. Open front grille.ModelStock Ref£Trade Lo-Carbon Revive 5473850278.78 Lo-Carbon Revive SELV 5473851357.05 Lo-Carbon Revive/SELV HTP continuous running fan with kitchen or bathroom setting, with a combination of trickle and boost speeds selectable from 9, 15, 30 and 60l/s. 5 year warranty. Adjustable dynamic ambient response humidity sensor. Timer adjustable between 1 and 30 minutes. In built boost activated

25 by pullcord, humidity sensor, switched live or remote button. Open front grille.ModelStock Ref£Trade Lo-Carbon Revive473852237.56 Lo-Carbon Revive SELV473853310.45 Accessories ModelStock Ref£Trade Wall Kit White25410221.55 Wall Kit Brown25410021.55 Conversion kit40868028.17 Ceiling kit407928 16.41 Window kit40792723.67 Decoration Frame47404111.00 Dimensions (mm) D B A CØ D A B CØ D 30 132/102 99 193 Closed/Open Grille Decoration Frame Dimensions (mm)A C A B A B C 259 191 10 Performance Guide Pr es su er P a Volume Flow l/s Low Kitchen Boost High Kitchen Boost Low Trickle Bathroom Boost 0 20 40 60 80 100 120 140 160 0 10 20 30 40 50 60 1 1 2 2 3 3 4 4 Extract Performance (l/s) Power Consumption (Watts) Model Trickle LowBathroom Boost Low Kitchen Boost High Kitchen Boost Trickle Low Bathroom Boost Low Kitchen Boost High Kitchen Boost Revive 9 15 30 60 1.4 2 6 26

26 Lo-Carbon Solo Plus/SELV •Up to 70% energy saving •Filterless as standard - innovative impeller design means no need for a filter •5 Year Lo-Carbon motor guarantee•Meets current Building Regulations Approved Documents F & L •IPX4 rated - IPX7 rated (SELV) •Flush or surface mountable with adjustable rear or side exit spigot •SELV models suitable for installation over or within reach of a shower or bath•Extremely low sound levels •Suitable for wall, ceiling and panel mounting •SELV Models - Supplied with a remote transformer Long Life Ventilation The Lo-Carbon Solo Plus range from Vent-Axia has been specially designed for through the wall and ducted applications, suitable for internal bathrooms, toilets and other small rooms. Finished in white, the Lo-Carbon Solo Plus can be flush or surface mounted, with a 2 position 100mm circular spigot for rear entry or connecting to a vertical ducting system. The powerful centrifugal impeller allows installations using 100mm ducting in straight runs, whilst still achieving 15l/s as required by Building Regulations Approved Document F.Continuous running products, such as the Lo-Carbon Solo Plus, installed in all wet areas of a dwelling are classed as a wholehouse ventilation system and therefore only need to move the amount of air as outlined in table 5.1a and 5.1b of Building Regulations Approved Document F. The Lo-Carbon Solo Plus has an adjustable boost speed which is set at installation variable between a wall or duct setting for boost/override operation to meet Building Regulations thus ensuring minimum energy usage and low sound levels. All models have an optional speed for constant trickle ventilation (12l/s), selectable at installation. Depending on the model, the fan will switch from trickle (if selected) to boost via the pullcord/light switch/humidity sensor/PIR. All models can be wall, panel or ceiling mounted and can be connected to either circular, rectangular or Vent-Axia’s flat ducting. Enclosure of the electrical components is manufactured from flame retardant grade material.Safety Extra Low Voltage Fan (SELV) Designed for areas where a fan has to be fitted over or within Zone 1 in a room containing a fixed bath or shower according to IEE wiring regulations (BS 7671), the Lo-Carbon Solo Plus SELV fan can be safely installed within the spray area. The fan is rated IPX7. Control is by the supplied mains safety isolating transformer unit with 12V DC SELV output, which is sited away from any source of spray and out of reach of a person using a fixed bath or shower. Controller Supply voltage 220-240V/1/50Hz. Output to fan SELV 12V DC. Models Lo-Carbon Solo Plus P/SELV P (Pullcord) Flush or surface mountable. Control by Pullcord. 2 Speed. Constant trickle option. Adjustable boost. In-built Lo-Carbon controller. ModelStock Ref£Trade P427481151.04 SELV P427485 160.21 Lo-Carbon Solo Plus T/SELV T (Timer) Flush or surface mountable. Control by room light or switch. 2 Speed. Constant trickle option. Adjustable boost. Adjustable timer overrun. Delay on timer. In-built Lo-Carbon controller.ModelStock Ref£Trade T427482173.05 SELV T427486 183.08 Lo-Carbon Solo Plus HT/SELV HT (Humidistat/Timer) Flush or surface mountable. Humidity controlled fan with override pullcord. Constant trickle option. Adjustable boost. Adjustable timer overrun. Delay on timer. Adjustable humidity sensor. In-built Lo-Carbon controller. Datalogger as standard on all Lo-Carbon humidity controlled Solo Plus fans.ModelStock Ref£Trade HT427483 244.09 SELV HT427487 251.75 Lo-Carbon Solo Plus TM/SELV TM (Timer/PIR) Flush or surface mountable. Control by integral PIR detector. 2 Speed. Constant trickle option. Adjustable boost. In-built Lo-Carbon controller.ModelStock Ref£Trade TM427484 343.28 SELV TM427488 350.90

27 Dimensions (mm) B D C A E F H I J GA B C D EØF G H I J 263 224 106 55 98 62 65 98 21 34 Weight 2.2kg, SELV Weight 2.7kg. Dimensions: (W x H x D) 87x87x33mm. Performance Guide (Duct Mode) 1 2 3 0 20 40 60 80 100 120 0 5 10 15 20 25 Pr e ssu e r P a Volume Flow l/s Boost Low Trickle High Trickle 1 2 3 Extract Performance l/s (m 3 /h) Power consumption - Watts dB(A) @ 3m SFP (W/l/s)Model Boost High trickle Low Trickle Boost High trickle Low Trickle Boost High trickle Low Trickle @ 0Pa Lo-Carbon Solo Plus/SELV P/T/HT/TM Wall mode 18 (64.8) 12 (43.2) 8 (28.8) 6 2.9 2.3 33.5 27 23.5 0.28 Duct mode 21 (75.6) 17 (61.2) 11 (39.6) 8.4 5.3 3.2 35.5 33 26 0.29 Tested at 240VAC @ 50Hz Accessories Lo-Carbon Solo Plus BezelUsed when flush mounting - reduces the need to make good.ModelStock Ref£Trade Bezel404106 11.89 ModelStock Ref£Trade Wall Kit White25410221.55 Wall Kit Brown25410021.55 Filter pack (1 per pack)The design of the Lo-Carbon Solo Plus means that it does not need a filter. However, if you are going to install the product in a heavily greasy environment, you may want to protect the product by fitting a filter.ModelStock Ref£Trade Filter pack4492655.88

28 Powerful Lo-Carbon In-Line Fan Kit The Vent-Axia Lo-Carbon Minivent ducted bath/shower kit includes all the components necessary to install a ducted 100mm system. This simplifies fitting of an efficient ventilation system to small rooms including bathrooms, shower rooms and toilets. It is especially suitable for en-suite bathrooms.Lo-Carbon Minivent Shower Kit installed When installed, the fan kit has ample performance to meet the Building Regulations requirements for toilets and bathrooms. The timer version should be used for internal rooms. The kit consists of a Lo-Carbon Minivent In-Line fan, a white ceiling grille and spigot, 3 metres of flexible duct and an external louvre for soffit or wall mounting. The duct should be cut to the required length and the bend radius kept to a maximum to provide optimum fan performance. Enclosed terminal compartment, Class 2 appliance. Supply voltage 220-240/1/50Hz. Models Lo-Carbon Minivent Shower Fan (Basic)Comprises - high output tube fan, 3 metres of flexible duct, ceiling inlet grille and spigot, soffit/wall outlet grille.ModelStock Ref£Trade Basic44142162.04 Lo-Carbon Minivent Shower Fan (Timer)Comprises - high output tube fan, 3 metres of flexible duct, ceiling inlet grille and spigot, soffit/wall outlet grille.ModelStock Ref£Trade Timer44142274.76 Dimensions (mm) A B Rear View C DØ E Side View A B C DØ E 130 155 90 98 27Internal/External Grille Dimensions 140x140mmTransformer (W x H x D) 87 x 87 x 33 Performance GuideExtract performance- FID SounddB(A)SFP(W/l/s)Model m 3 /h l/s Watts @ 3m @ 0Pa Lo-Carbon Minivent B/T 110 31 6.5 23 0.21 Lo-Carbon Minivent•Complete kit supplied •Meets Building Regulations Approved Document F & Lrequirements for toilets and bathrooms at max 1.5m of ducting and 1x 90° bend •Adjustable timer version available •5 Year Motor Guarantee•1 of 2 speeds selectable at installation cting

29 100mm Lo-Carbon axial in-line shower fan and light kit. Provides simultaneous fan and light operation. Suitable for shower enclosures and wet areas. Available with both a white and chrome bezel on light assembly. The light assembly can be held in place using fixing clips or screws. Typical Specification CE marked in accordance with all the relevant EEC Harmonised Directives. Fan double insulated and the motor is fitted with Thermal Protection. Light assembly class III.Electrical 12 volt DC 3W GU5.3 sealed lamp. Powered by an LED Driver. LED lamp lumens output 180lm – 200lm Input, AC. Output - 12 volt DC. 1A. Models Lo-Carbon Vent-A-Light Fan and LED Light Kit (Basic)100mm axial in-line shower fan and light kit. Includes fan, 3m flexible ducting, white grille, LED lamp light transformer and light assembly with white and chrome bezels.ModelStock Ref£Trade Basic441423 129.68 Lo-Carbon Vent-A-Light Fan and LED Light Kit (Timer)100mm axial in-line shower fan and light kit. Fan has electronic overrun timer adjustable from 5 to 30 minutes. The factory setting is 15 minutes. Includes fan, 3m flexible ducting, white grille, LED lamp light transformer and light assembly with white and chrome bezels. ModelStock Ref£Trade Timer441424 144.95 Dimensions (mm) E Side View Rear View DØ A B CG H Ø F A B C DØ E FØ G HØ 130 155 90 98 27 140 74 98 Internal/External Grille Dimensions 140x140mmFan Transformer (W x H x D) 87 x 87 x 33Performance Guide Extractperformance - FID FanWatts LightWatts SounddB(A)@ 3m SFP(W/l/s)@ 0Pa Model m 3 /h l/s Lo-CarbonVent-A-Light B/T 110 31 6.5 3 23 0.21 Tested at 240V 50Hz Lo-Carbon LED Vent-A-Light •Suitable for shower enclosure and wet areas •Now with a 3W LED Lamp•Provides simultaneous fan and light operation •Meets current Building Regulations ApprovedDocuments F & L •1 of 2 speeds selectable at installation •Double insulated fan •Light assembly Class III •5 Year Motor Guarantee •Supplied with white and chrome bezels

30 Lo-Carbon Quadra/SELV•Meets current Building Regulations Approved Document F & L forintermittent or continuous use •Recognised in SAP PCDB - Low SFP on PCDB 0.38 W/l/s •100mm circular spigot for easy installation and replacement of anyexisting fan - flush or surface mount •Filterless technology and maintenance free •Lo-Carbon motors offering 90% energy savings and long life •Motor cassette cartridge for simple replacement •Integral daylogger (option on SELV models) •5 Year Motor Guarantee•IPX4 rated - IPX7 rated (SELV) •Suitable for wall, ceiling and panel mounting Ventilation for any room The Lo-Carbon Quadra offers a single fan suitable for surface or flush mounting. Low speed selectable between 6, 9 and 12l/s and high between 15, 30 and 60l/s all with through the wall or two ducted selections to ensure installed performance is met.Lo-Carbon Quadra SELV The Lo-Carbon Quadra SELV has been designed to meet building requirements where there is a need to fit in Zone 1 containing a fixed bath or shower according to IEE wiring regulations. The Lo-Carbon Quadra SELV can be safely installed within the spray area with the 24VDC Safety Isolating Power Supply situated away from the spray zone and out of reach of the person using the facility. Discrete With discrete aesthetics and low noise levels due to an accurately balanced impeller, it is also one of the most unobtrusive centrifugal kitchen fans available. The front cover design also provides no area for dirt to build up so it stays looking better for longer.Models Lo-Carbon Quadra TP/SVTP (Timer/Pullcord)Dual speed: continuous running or intermittent to high speed. High speed via pullcord (On/Off) or switch live (with overrun timer). ModelStock Ref£Trade TP439251 244.69 SVTP442865 281.39SVTP Datalogger446269319.76 Lo-Carbon Quadra HTP/SVHTP(Humidistat/Timer/Pullcord)Dual speed: continuous running or intermittent to high speed. High speed via integral pullcord (On/Off), integral adjustable humidity sensor or switch live (with overrun timer). When humidity sensor is triggered the flow rate increases proportionally with %RH to 50% of the set Boost speed.ModelStock Ref£Trade HTP439181 287.14 SVHTP442866 329.37SVHTP Datalogger446270367.76 Lo-Carbon Quadra TM/SVTM (Timer/PIR) Dual speed: continuous running or intermittent to high speed. High speed via integral PIR sensor or switch live (both with overrun timer).ModelStock Ref£Trade TM439253 338.24 SVTM442867 388.61 Accessories ModelStock Ref£Trade Flush Mounting Kit439256 14.33 Filter (optional)439927 7.16 Decoration Frame442551 20.29 Wall Kit White25410221.55 Wall Kit Brown25410021.55 WINNER 2011 Winners of the Energy Efficiency Initiative 2011 Awardwith our Lo-Carbon Continuous Ventilation Product Range.

31 Dimensions (mm) A C F D EØ B H G Rear View Front View Side View AB C D EØ F G H 230 260 112 67 98 27 58 79 Performance Guide 1 2 3 6 l/s 9 l/s12 l/s4 5 6 15 l/s30 l/s63 l/s0 50 100 150 200 250 300 0 10 20 30 40 50 60 70 Volume (l/s) Pressure (P a) 4 5 6 Boost Speed Volume (l/s) Pressure (P a) 0 10 5 15 20 0 10 15 5 20 3 2 1 Continuous Trickle Speed Extract Performance Power Sound HighLow High Low dB(A) @ 3m SEC Model m 3 /h l/s m 3 /h l/s Watts Watts High Low Class Lo-Carbon Quadra/SELV TP/ HTP/ TM 227 63 22 6 38 3.8 50 20 D FID Performance. Tested in through the wall installationSAP PCDB Performance Systems With Rigid Ductwork Installation Only Unit Configuration Location Fan Speed Setting Flow Rate (l/s) SFP (W/l/s) In Room Kitchen15 l/s 15.8 0.41 In Room Wet Room 9 l/s 14.6 0.61 Through Wall Kitchen15 l/s 21.4 0.38 Through Wall Wet Room 9 l/s 19.5 0.50 Systems With Flexible Or Mixed Ductwork Installation Only Unit Configuration Location Fan Speed Setting Flow Rate (l/s) SFP (W/l/s) In Room Kitchen15 l/s 13.7 0.41 In Room Wet Room 9 l/s 12.9 0.63 Through Wall Kitchen15 l/s 21.4 0.38 Through Wall Wet Room 9 l/s 19.5 0.50

32 Lo-Carbon Silhouette 125•Models Basic/Timer/Humidity & Timer•Low power consumption - Lower running costs •Quiet running •Fully opening and closing non transparent shutters - Improved insulationand privacy •1 of 2 speeds selectable at installation •IPX4 rated•Ball bearing motors for vertical or horizontal application •Unique humidity sensor track - Improved response •5 Year Motor Guarantee•Suitable for wall, ceiling and panel mounting Slimline Bathroom Ventilation With a slim profile of only 18mm, Lo-Carbon Silhouette blends in with the wall surface to provide an unobtrusive installation. Lo-Carbon Silhouette has a FID performance up to 160m 3 /h. It can be ceiling/panel mountedand connected to an appropriate duct run to the outside. Models Lo-Carbon Silhouette 125B 125mm bathroom/toilet fan with indicator light and back draught shutter.ModelStock Ref£Trade 125B446483118.99 Lo-Carbon Silhouette 125T (Timer)125mm bathroom/toilet fan with integral adjustable electronic overrun timer (5-30 minutes), indicator light which operates on manual override only, and back draught shutter.ModelStock Ref£Trade 125T446484 134.26 Lo-Carbon Silhouette 125HT (Humidistat/Timer)125mm bathroom/toilet fan with integral adjustable auto humidity sensor from 60-90% RH and overrun timer, indicator light which operates on manual override only, and back draught shutter. Datalogger as standard on all Lo-Carbon humidity controlled Silhouette fans. ModelStock Ref£Trade 125HT446485 225.23 Accessories ModelStock Ref£Trade Wall Kit45522624.43 Dimensions (mm) PanelA BØ C D A A BØ C D 187 125 131 149 Performance Guide 0 0 5 10 15 20 30 Air Volume l/s Pressure Pa 25 35 45 40 20 15 5 10 1 2 CurveRef Extract Performance SounddB(A) @ 3m SFP(W/l/s)@ 0Pa Model m 3 /h l/s Watts Lo-CarbonSilhouette125B/T/HT Low 1 120 33 4.5 33 0.14 High 2 160 44 8 37 0.18

33 Long Life Ventilation Vent-Axia Lo-Carbon VA150 fans feature Lo-Carbon long life DC energy saving motors that last up to 5times longer than conventional motors, whilst delivering up to 60% energy savings. The extended life of Lo-Carbon fans is due to the use of a new generation of high quality electronically controlled ball-bearing motors especially developed for this range. The motors are perfectly designed for the wet conditions of utility rooms and kitchens, extracting stale, moisture-laden air quietly and efficiently. Shutters The Vent-Axia Lo-Carbon VA150 range is fitted with a motorised shutter mechanism that uses no extra power in operation or off. Installation The Lo-Carbon VA150 range is suitable for installation in panels, walls or windows using the kits available. Lo-Carbon fans are quick and simple to fit using reversible grommets and easy-wire terminals, and are suitable for wall or ceiling mounting atany angle.150mm telescopic wall kits are available with a white or brown outside grille. The kit is supplied with a telescopic wall sleeve to fit walls 225–360mm thick. Hole diameter 152mm. Window fitting kits are available for use with allLo-Carbon 150mm models through single or double glazed windows up to 40mm thick. Holediameter 152mm. Models Lo-Carbon VA150P (Shutter/Pullcord)Ultra long life DC energy saving motor. Fitted with a motorised shutter. Controlled via pullcordOn/Off switch. ModelStock Ref£Trade VA150P459123 205.61 Lo-Carbon VA150T (Shutter/Timer) Ultra long life DC energy saving motor. Fitted with a motorised shutter.Controlled via integral power supply with electronic adjustable overrun timer (5-30 minutes).ModelStock Ref£Trade VA150T459124 253.59 Lo-Carbon VA150HP (Shutter/Humidistat) Ultra long life DC energy saving motor. Fitted with a motorised shutter. Controlled via integral power supply with pullcord override switch and adjustable humidity sensor (60-95% RH).ModelStock Ref£Trade VA150HP459125 313.27 Accessories ModelStock Ref £Trade Wall Kit White14090224.70 Wall Kit Brown14090324.70 Window Kit 14090124.70 Dimensions (mm) B A A E C DØ G H I F F Panel Wall Window A B C DØ E F G H I 216 224 80 146 60 220 37 55 104 Weight 1.2kgPerformance Guide ExtractPerformanceSounddB(A) SFP(W/l/s)Model Setting m 3 /h l/s @ 3m Watts @ 0Pa Lo-Carbon VA150P/T/HP Utility 160 46 33 7.5 0.16 Kitchen 230 64 36 11.5 0.18 Lo-Carbon VA150 •Reduces the home’s carbon footprint •Long life Lo-Carbon motor lasts up to 5 times longer than conventional motors •Up to 60% energy saving•Meets current Building Regulations Approved Document F & L when installed •IP44 rated •Low sound levels •5 Year Motor Guarantee•Suitable for wall, ceiling, window and panel mounting •Fitted with a motorised shutter •1 of 2 speeds selectable at installation

34 Lo-Carbon Silhouette 150 •Stylish ultra low profile grille •Downstream airflow guide vanes for improved pressure development •Ball bearing motors for vertical or horizontal application •Wall kit design meets Building Regulations Approved Document Frequirements •5 Year Motor Guarantee•1 of 2 speeds selectable at installation •IPX4 rated •Low Specific Fan Power•Suitable for wall, ceiling and panel mounting Slimline Lo-Carbon Kitchen Ventilation The Lo-Carbon Silhouette 150 range is designed for modern living. With a profile of only 19mm on the kitchen models, Lo-Carbon Silhouette blends in with the wall surface to provide an unobtrusive installation.Mounted in the centre of the fan, beneath the ultra slim profile grille, are the electronics, incorporating a humidistat (HT model) for detecting a change in internal humidity or an overrun timer option that is adjustable between 5 and 30 minutes.FID performance of 65l/s, double insulated. Power consumption only 9 Watts. Models Lo-Carbon Silhouette 150B 150mm kitchen fan with indicator light and back draught shutter. ModelStock Ref£Trade 150B441628119.46 Lo-Carbon Silhouette 150T (Timer)150mm kitchen fan with integral adjustable electronic overrun timer (5-30 minutes), indicator light which operates on manual override only and spring back draught shutter.ModelStock Ref£Trade 150T441629 134.26 Lo-Carbon Silhouette 150HT (Humidistat/Timer)150mm with integral adjustable auto humidity sensor from 60-90% RH and overrun timer, indicator light which operates on manual override only and back draught shutter. Datalogger as standard on all Lo-Carbon humidity controlled Silhouette fans. ModelStock Ref£Trade 150HT441630 237.40 Accessories ModelStock Ref£Trade Wall Kit White14090224.70 Wall Kit Brown14090324.70 Dimensions (mm) A D C ØB A G H G A BØ C D G H 223 147 130 19 220 37Weight 1.75kg

35 Performance Guide 0 5 10 15 20 25 0 10 20 30 40 60 Air Volume l/s Pressure Pa 30 35 40 50 70 2 1 Curve Extract Performance Sound dB(A) SFP (W/l/s)Model Setting Ref m 3 /h l/s Watts @ 3m @ 0Pa Lo-Carbon Silhouette 150B/T/HT Utility Setting 1 200 55 6 35 0.11 Kitchen Setting 2 234 65 9 43 0.14 Fixing hole diameter 152mmØ (when wall kit used)

dMEV, MEV & PIV Systems What is dMEV & MEV?The current Building Regulations Approved Document F gives examples of four main methods of ventilation. System 3, continuous mechanical extract ventilation, can be achieved using a single centralised extract unit such as the Sentinel Multivent ducted from ‘wet’ rooms (kitchen, bathroom, en-suite and WC) or by decentralised individual fans (dMEV) in the ‘wet’ rooms. The fans run continuously at near silent levels providing a simple and effective form of ventilation. Lo-Carbon ResponseThe continuous running, constant volume Lo-Carbon Response dMEV unit features an innovative digital display. The unique display (patent pending) provides the calibrated installed airflow and pressure of the installation meaning that there is no need to test the installation with an airflow measuring device. Quiet running and with high pressure development, the Response is best in class - an achievement that was recognised when it won Product of the Year at the prestigious Housebuilder Awards 2014.

Lo-Carbon Centra ® /SELVdMEV Unit 38-39 Lo-Carbon Response/SELV dMEV Unit 40-41 Lo-Carbon MultiventMEV Unit 42-43 MultiventMEV Unit 44-45 Lo-Carbon Sentinel ®Multivent/PlusMEV Unit 46-49 Lo-Carbon Multivent MVDC-MS/MSHMEV Unit 50-51 Lo-Carbon PoziDryPositive Pressure Unit 52-53 Lo-Carbon PoziDry Compact Positive Pressure Unit 54-55

38 Lo-Carbon Centra/SELV •Building Regulations Approved Documents F and L compliant, System 3Continuous mechanical extract •Recognised in SAP PCDB - Low SFP •Discreet, tasteful styling •IPX4 rated - IPX7 rated (SELV) •dMEV Pressure detection device •5 Year Motor Guarantee •Suitable for wall, ceiling, panel and window mounting •SELV models supplied with remote transformer and suitablefor ‘Zone 1’ What is de-centralised MEV (dMEV)? Building Regulations Approved Document F gives examples of four main methods of ventilation. System 3, Continuous mechanical extract ventilation, can be achieved using a single centralised extract unit such as the Sentinel Multivent ducted to ‘wet’ rooms (kitchen, bathroom, en-suite and WC) or by decentralised individual fans, such as the Lo-Carbon Centra in the ‘wet’ rooms. The fans run continuously at near silent levels providing a simple and effective form of ventilation. SELV (Safety Extra Low Voltage) is designed for areas where a fan can be installed within Zone 1 in a room where there is a fixed bath or shower. Ingress Protected (IP) to IPX7 Lo-Carbon Centra SELV can be fitted safely within the spray area. The separate transformer can be mounted away from the spray zone and out of reach from the bathor shower. The Lo-Carbon Centra meets the latest requirements of the Building Regulations Approved Document F for wholehouse system ventilation and all models come with a 5 year motor guarantee. Selection of the two trickle flow rates (6l/s or 9l/s) is via a simple ‘jumper’ on the control board. Different methods are available for operating the 15 l/s boost speed from a simple switched live to integral humidistat. See individual models for further details. The attractive and discreet styling of the Vent-Axia Lo-Carbon Centra will complement the décor of any new home while virtually silent operation ensures optimum ventilation is achieved without intrusive noise. Specific Fan Power dMEV version recognised in SAP PCDB. Lo-Carbon Centra has a specific fan power of only 0.18 W/l/s in through-the-wall kitchen applications. Models Lo-Carbon Centra dMEV Auto speed selection at installation and suitable for bathrooms or kitchens. The integral air pressure sensor checks the airflow when first installed and also helps the fan to compensate for external wind pressure.Stock Ref £Trade 441782 123.19 Lo-Carbon Centra T/SELV T (Timer)Ideal for bathroom and toilet applications, this unit runs continuously on trickle setting and may be boosted by the switched live input which activates the timer (fixed 15 min on T models, adjustable 5-30 minutes on SELV models).ModelStock Ref£Trade T442954139.62 SELV T443175 171.28 Lo-Carbon Centra TP/SELV TP (Timer/Pullcord)For bathroom/toilet applications, the continuous running TP model is boosted by the pullcord which activates the timer (fixed 15 min on TP models, adjustable 5-30 minutes on SELV models).ModelStock Ref£Trade TP447127 156.68 SELV TP 447128187.67 Lo-Carbon Centra HT/SELV HT (Humidistat/Timer)For bathroom/toilet applications, the continuous running HT model is automatically boosted by the built-in humidistat or by a switched live input which activates the timer (fixed 15 min on HP models, adjustable 5-30 minutes on SELV models). ModelStock Ref£Trade HT442955 182.51 SELV HT443176 214.44 WINNER 2011 Winners of the Energy Efficiency Initiative 2011 Awardwith our Lo-Carbon Continuous Ventilation Product Range

39 Lo-Carbon Centra HTP/SELV HTP(Humidistat/Timer/Pullcord)For bathroom/toilet applications, the continuous running HTP model is automatically boosted by the built-in humidistat or by the pullcord which activates the timer (fixed 15 min on HTP models, adjustable 5-30 minutes on SELV models). ModelStock Ref£Trade HTP443045 182.51 SELV HTP 443177214.44 Accessories ModelStock Ref£Trade 150mm Conversion Kit44333428.65 Wall Kit White25410221.55 Wall Kit Brown25410021.55 Window Kit44294723.32 Ceiling Kit44380015.84 Dimensions (mm) DØ A A B C Model A B C DØ Lo-Carbon Centra dMEV/All SELV 160 35 115 99 Lo-Carbon Centra T/TP/HT/HTP 160 35 80 99 Transformer 87 x 87 x 33mm (W x H x D) (SELV models only) Performance Guide Extract Performance (l/s) Power Consumption (Watts) Sound dB(A)@ 3m Trickle TrickleTrickle TrickleTrickle TrickleModel Low High Boost Low High Boost Low High Boost Lo-Carbon Centra dMEV/All SELV 6 9 15 1.4 1.6 2.4 10.8 15.5 25.2 Lo-Carbon Centra T/TP/HT/HTP 6 9 15 3.2 3.5 4.2 10.8 15.5 25.2 SAP PCDB Performance (dMEV model) Systems With Rigid Ductwork Installation Only Unit Configuration Location Fan Speed Setting Flow Rate (l/s) SFP (W/l/s) In Room (Ducted) KitchenHigh 13.2 0.32 In Room (Ducted) Wet Room 9 l/s 8.4 0.28 Through Wall KitchenHigh 13.5 0.18 Through Wall Wet Room 9 l/s 8.6 0.20 Systems With Flexible Or Mixed Ductwork Installation Only Unit Configuration Location Fan Speed Setting Flow Rate (l/s) SFP (W/l/s) In Room (Ducted) KitchenHigh 13.2 0.37 In Room (Ducted) Wet Room 9 l/s 8.6 0.31 Through Wall KitchenHigh 13.5 0.18 Through Wall Wet Room 9 l/s 8.6 0.20

40 Lo-Carbon Response/SELV •Recognised in SAP PCDB•Constant volume •Display showing airflow and system pressure (Patent pending) •Switched live connection for external switches/sensors •220-240V input •Day logger feature on Humidistat models •6l/s or 8l/s trickle speed selection 13l/s boost speed •IPX4 rated - IPX7 rated (SELV) •Multi-orientation grille•New comfort control option (Patent pending) Lo-Carbon Response Continuous running, constant volume dMEV unit with switched live (LS) and innovative digital display. Quiet running and with high pressure development, the Response is best in class.The Response Fan from Vent-Axia Following the introduction of the Domestic Ventilation Compliance Guide within Part F 2010, and the requirement to test the installed airflow of extract fans, the Response fan from Vent-Axia provides the easiest install available. The unique display (patent pending) provides the calibrated installed airflow and pressure of the installation meaning that there is no need to test the installation with an airflow measuring device. The constant volume technology automatically adjusts the speed of the fan to ensure the desired airflow is delivered. With a new silent higher pressure axial impeller Lo-Carbon Response can meet the requirements of many domestic installations without the need to use a traditional centrifugal fan.Axial, rather than centrifugal? Some centrifugal fans can develop pressure but the actual installed airflows can mean that the pressure is of no use as the airflow falls below the requirement. Using the new high pressure silent axial impeller has enabled the fan to not only develop great installed performance over duct runs, but to do it in the most energy efficient way. Response can provide excellent pressure whilst still maintaining energy efficiency and not wasting energy on high pressure at low air volumes. This enables the fan to save up to 64% of the specific fanpower (SFP) of the SAP PCDB data for existing centrifugal alternatives. Configuration Location Alternative Centrifugal Fan SFP Vent-Axia Response SFP In room Kitchen 0.38 0.17 Wet Room 0.29 0.18 Through Wall Kitchen 0.36 0.13 Wet Room 0.28 0.15 0 20 40 0 5 10 15 20 25 30 Pr es su er P a Volume Flow l/s 60 80 100 ExamplePressure Loss(6m flexibleducting, 2x90 bends) Unnecessarypressurewhich wastesenergy Vent-Axia Lo-CarbonResponse FanCompetitor Product 2 2 1 1 Side View of Airflow Display Be confident that the Response is delivering the right performance with our innovative digital display showing the airflow and system pressure of the installed product.Comfort Control Option Designed to offer a more relaxing environment to the homeowner, the Lo-Carbon Response features a delayed start option. This new, patent pending, comfort control option is selectable at installation and allows the homeowner to enjoy a quiet, peaceful bathroom for up to 20 minutes before the Boost activates. Furthermore, if the light switch turns On and Off within 3 minutes, the Boost will not activate. No more disturbing the family if the bathroom light is turned on during the night.

41 Model Lo-Carbon Response dMEVAuto speed selection at installation. The integral air pressure sensor checks the airflow when first installed and also helps the fan to compensate for external wind pressure.Stock Ref £Trade 404535136.94 Lo-Carbon Response/SELV TP(Timer/Pullcord)For kitchen, utility and bathroom/toilet applications, the continuous running TP model incorporates an adjustable overrun timer. This adjusts the time the fan will continue to run on boost after the LS connection has been deactivated.This is also the run time period for the pullcord.ModelStock Ref£Trade TP404876170.43 SELV TP 404878200.84 Lo-Carbon Response/SELV HTP (Humidistat/Timer/Pullcord) For kitchen, utility and bathroom/toilet applications, the continuous running HTP model incorporates an adjustable (40% - 90%) ambient response humidistat. The fan will increase the extract rate if the humidity rises above the point set at installation. Day logger as standard.ModelStock Ref£Trade HTP404877196.26 SELV HTP 404879228.19 Accessories ModelStock Ref£Trade Wall Kit White25410221.55 Wall Kit Brown25410021.55 150mm Conversion kit40868028.17 Ceiling kit407928 16.41 Window kit40792723.67Decoration Frame47404111.00 Dimensions (mm) A B CØ D 90 45 99 190 B A CØ D D Performance Guide 0 20 10 30 40 50 0 5 10 15 20 25 30 Pr e ssu reP a Volume Flow l/s 13l/s Constant Volume Maximum pressure available to deliver airflow 6l/s Constant Volume 8l/s Constant Volume 1 2 3 4 1 2 3 4 Extract Performance l/s (m 3 /h) - FID Watts dB(A) @ 3mModel Trickle Low Trickle High Boost Trickle Low Trickle High Boost Trickle Low Trickle High Boost Lo-Carbon Response 6 (21) 8 (29) 13 (43) 1.0 1.2 1.7 12 17 32.5 SAP PCDB PerformanceUnitConfiguration Location SFP (W/l/s) In room (rigid duct) Kitchen 0.17 In room (rigid duct) Wet Room 0.18 In room (flex duct) Kitchen 0.17 In room (flex duct) Wet Room 0.16 Through wall Kitchen 0.13 Through wall Wet Room 0.15

42 The Lo-Carbon Multivent continuous mechanical extract ventilation range is designed for the simultaneous ventilation of separate areas in the home or as a multipoint extractor system for a wide range of commercial applications. In the home the system is usually located in the loft or airing cupboard with ducts taken to the bathroom, utility room and toilets to removes air pollutants such as water vapour and odours.Lo-Carbon Multivent is idealfor a range of commercial applications such as toilets, fitting rooms, and kiosk’s. The units can be installed at any angle and where the ambient air has a high humidity content condensate drainsare provided.The Lo-Carbon Multivent H version incorporates a built-in humidity sensor to switch between two of the three speeds. A Wireless Controller is available for use with the Lo-Carbon Multivent H with three speed options offering total control of the system. Lo-Carbon MVDC The Lo-Carbon MVDC Multivent minimises running costs by incorporating the latest DC technology. DC efficiency means lesswear and tear on the motor which guarantees longer life.Extended motor guarantee to 5 years offered. ModelsCAS ModelStock Ref£Trade MVDC181520298.22 MVDCH183020323.07 Accessories Acoustic Lining KitCAS For reducing noise in sensitive installationsStock Ref£Trade 438195 20.06 Multivent Wireless ControllerCAS (for use with MVDCH only)Stock Ref£Trade 426035 32.91 Lo-Carbon Multivent•Reduces your carbon footprint •EC low energy consumption motors •Fitted with four extract 100 or 125mm diameter spigotsallowing quick connection to ducts •Option of wall, ceiling and loft mounting •Quiet running suitable for continuous operation •Can extract from a number of rooms, depending on thedwelling •Wireless Controller available

43 Dimensions (mm) Weight: 5.50kg A J I E C B Ø125H D F G Reduction Pieces Diameter: 100/125mm A B C D E F G H I J 340 72.5 25 15 360 214 310 249 150 85 Performance Curvelow med high l/s m 3 /h VOLUME Technical DataLow Medium High SEC Class (inc. LDC) Current Power Current Power Current PowerModelAmps Watts Amps Watts Amps Watts SEC ClassMVDC 0.1 9 0.23 20 0.39 44 E BMVDCH 0.1 9 0.23 20 0.39 44 D B Sound LevelSound dB(A) @ 3m FID Perf. CasingDuct Inlet Duct InletModelSpeed m 3 /h (l/s) Breakout 100mmØ 125mmØMVDCLow 232 (64) 33.3 36.5 36.5Medium 365 (100) 33.7 47.9 47High 434 (120) 38.8 51.7 51.5 MVDCHLow 232 (64) 33.3 36.3 36.5Medium 365 (100) 33.7 47.9 47High 434 (120) 38.8 51.7 51.5

44 Multivent •Fitted with four extract 100 or 125mm diameter spigots allowingquick connection to ducts •Option of wall, ceiling and loft mounting •Quiet running suitable for continuous operation •Can extract from a number of rooms, depending on the dwelling •Wireless Controller available The Multivent continuous mechanical extract ventilation range is designed for the simultaneous ventilation of separate areas in the home or as a multipoint extractor system for a wide range of commercial applications. In the home the system is usually located in the loft or airing cupboard with ducts taken to the bathroom, utility room and toilets to removes air pollutants such as water vapour and odours.Multivent is idealfor a range of commercial applications such as toilets, fitting rooms and kiosks. The units can be installed at any angle and where the ambient air has a high humidity content condensate drains are provided.The Multivent H version incorporates a built-in humidity sensor to switch between two of the three speeds. A Wireless Controller is available for use with the Multivent H with three speed options offering total control of the systems. ModelsCAS ModelStock Ref£Trade MV250181510250.95 MV250H183010287.26Accessories Acoustic Lining KitCAS For reducing noise in sensitive installationsStock Ref£Trade 438195 20.06 Multivent Wireless ControllerCAS(for use with MV250H only)Stock Ref£Trade 42603532.91

45 Dimensions (mm) Weight: 5.50kg A J I E C B Ø125H D F G Reduction Pieces Diameter: 100/125mm A B C D E F G H I J 340 72.5 25 15 360 214 310 249 150 85 Performance Curvelow med high l/s m 3 /h VOLUME Technical DataLow Medium High SEC Class (inc. LDC) Current Power Current Power Current PowerModelAmps Watts Amps Watts Amps Watts SEC ClassMV250 0.2 25 0.30 54 0.34 81 E CMV250H 0.2 25 0.30 54 0.34 81 E C Sound LevelSound dB(A) @ 3m Model Speed FID Perf.m 3 /h (l/s) Casing Breakout Duct Inlet 100mmØ Duct Inlet 125mmØMV 250low 161 (45) 22.4 27.9 27.8medium 305 (85) 31.0 42.9 43.2high 443 (123) 35.4 48.6 48.0MV 250Hlow 175 (48) 22.4 27.9 27.6medium 344 (95) 31.0 42.9 43.2high 443 (123) 35.4 48.6 48.0

46 Lo-Carbon Sentinel Multivent/Plus •Reduces your carbon footprint •Recognised in SAP PCDB •Specific fan power 0.16 W/l/s (K+1) •Suitable for use with external sensors and controllers •Wireless control option •Complies with Building Regulations ADF and ADL •Manufactured in the UK from recyclable materials Sentinel Multivent continuous mechanical extract ventilation, MEV is designed for the simultaneous ventilation of separate areas in the home or as a multipoint extraction system for a wide range of commercial applications. The units can be installed at any angle. Where the ambient air has a high humidity content condensate drains are provided. In support of Sentinel Multivent,Vent-Axia offers: •Practical advice on product selection and installation •Guidance on solutions to meet legislation requirements•Project management and site deliveries •After sales support and maintenance information The need to improve efficiency Sentinel Multivent has been designed to meet the exacting demands of developers, installers and users offering advanced control options and easier installation and commissioning. •Demand Control - enables precise ventilation rate, is set in 1% increments based on property size •Integral LCD display allows the installer to select appropriate low, normal and boost speeds to meet demand •Manual and automatic control options •Integral adjustable overrun timer and delay on timer•Plug-n-Play automatic sensor detection •Switched live and SELV connections •Dry Out setting – Option set at installation, Sentinel Multivent will run on boost for 1 week to assist in removing moisture•Optional Wireless Control – up to 4 controllers on any one system •Energy efficient EC/DC motors - 1/3 less energy lost to heat thana conventional AC motor •Low Specific Fan Power (SFP) making it one of the most efficient products on the market Legislation •Meets Building Regulations Approved Document F (System 3) •Recognised in SAP PCDB up to kitchen + 6 wet rooms •Meets carbon footprint reduction targets •Lowest SFP figures of any demand control MEV system The need for better health Removal of pollutants such as moisture, carbon dioxide and external fumes are all important factors in maintaining indoor air quality, helping to create a healthier living environment.•The integral humidity sensor (Sentinel Multivent H) increases fan speed in proportion to relative humidity levels, saving energy and reducing noise •The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room •Night time relative humidity increment setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature •Acoustically lined - low noise levels only 18.1 dB(A) @ 3m SAP PCDB In order to make the right choice, developers and contractors should refer to Building Regulations ADL1a, SAP 2012 and SAP PCDB.SAP PCDB was launched in June 2006 to reward innovative ventilation manufacturers by testing and listing energy efficient products that assist in helping developers meet their Target Emission Rates (TER).SAP is the underpinning methodology behind the Energy Performance Certificates and is used to demonstrate compliance with Building Regulations for Dwellings - Approved Document L (England and Wales), Section 6 (Scotland) and Approved Document F (Northern Ireland). SAP PCDB specifically relates to wholehouse ventilation systems and lists a number of Vent-Axia Mechanical Ventilation solutions which offer an improved SAP rating over and above the default for theseproduct types.

47 SEC Class Model SEC Class Sentinel Multivent/Plus C SAP PCDB Test Results (Sentinel Multivent) Exhaust TerminalFan Speed Total Configuration Setting Flow Rate SFP (W/l/s) K+1 32% 21 0.16 K+2 39% 29 0.16 K+3 49% 37 0.17 K+4 59% 45 0.21 K+5 68% 53 0.24 K+6 77% 61 0.29 SAP PCDB Test Results (Sentinel Multivent Plus) Exhaust TerminalFan Speed Total Configuration Setting Flow Rate SFP (W/l/s) K+1 20% 21 0.25 K+2 25% 29 0.22 K+3 30% 37 0.22 K+4 34% 45 0.22 K+5 40% 53 0.25 K+6 45% 61 0.27 To assist developers and contractors Vent-Axia can provide detailed scheme designs together with installation guidance and training.Your Carbon Footprint The Carbon Footprint is a measure of the amount of carbon dioxide (CO 2 ) emitted through the burning of fossil fuels. From a residential andcommercial building perspective, it is the amount of carbon generated when you consume a kilowatt of electricity. Reducing a building’s carbon footprint will ultimately reduce electricity bills and save money for every individual household or business. It will also help meet the UK target for the reduction of emissions, as well as allowing you to help the environment. ModelStock Ref£Trade Sentinel Multivent437601447.96 Sentinel Multivent H445655480.23 Sentinel Multivent Plus407001515.60 Sentinel Multivent Plus H407849544.24 Dimensions (mm) A J I E C B Ø125H D F G Reduction Pieces Diameter: 100/125mm A B C D E F G H I J 340 72.5 25 15 360 214 310 260 150 85

48 Performance Guide 0 100 200 300 400 500 600 700 0 20 40 50 0 200 250 300 100 150 350 400 450 500 550 600 650 60 80 100 120 140l/s m 3 /h 180160Pre ss ure P a Volume1 2 Sentinel Multivent Sentinel Multivent Plus 1 2 Stock RefModel Curve Ref Inlet Duct dB(A) FID l/s Power Watts SEC Class (inc. LDC) SEC Class 437601 / 445655 Multivent 1 (max) 38 121 45 E C 407001/ 407849 Multivent Plus 2 (max) - 165 83 E C Sound Data (Sentinel Multivent) Induct sound power levels dB dB(A) Speed 63 125 250 500 1K 2K 4K 8K @ 3m 10% Breakout 43.6 37 36.9 30.6 26.2 22.8 23.6 30.4 18.1 Extract 43.8 39.9 36.1 30.4 24.6 21.8 22. 30.3 17.8 28% Breakout 44 44.4 43.3 39 31.1 26.1 24.3 30.1 22 Extract 42.2 40.1 42.2 40.5 32 23.3 23.4 30.5 22 46% Breakout 45 42.8 46.7 44.1 38.8 35.6 26.7 30.6 25.8 Extract 40.8 42.5 46.4 44.4 41 31.1 25.3 30.3 26 82% Breakout 46.3 48.3 50 52.1 48.4 47.7 37.8 32.4 33.7 Extract 46.7 49.6 48.9 54.3 51.8 42.7 38.1 34.2 36.1 Sound Data (Sentinel Multivent Plus) Octave band, Hz, dB SWL SPL Speed % Test mode 63 125 250 500 1k 2k 4k 8k dB(A) at 3m 20 Inlet 45.0 46.0 43.9 34.1 27.4 22.8 23.1 29.7 20.5 Outlet 45.0 40.9 45.2 39.5 33.0 26.7 23.0 29.1 29.5 Breakout 43.9 37.4 36.5 35.5 26.7 22.6 23.7 30.2 19.0 40 Inlet 48.6 48.7 54.4 52.3 55.4 47.5 38.0 33.1 37.0 Outlet 49.1 54.6 54.4 55.0 55.7 51.7 39.7 39.5 42.9 Breakout 45.2 44.2 47.5 46.1 40.0 34.0 26.3 30.3 26.8 60 Inlet 48.6 48.7 54.4 52.3 55.4 47.5 38.0 33.1 37.0 Outlet 57.1 55.9 65.2 63.3 64.8 64.5 53.7 55.5 52.2 Breakout 49.0 49.7 58.0 53.7 48.4 46.4 36.4 33.3 34.9 80 Inlet 56.3 56.6 60.4 59.0 61.4 56.0 46.6 43.5 43.5 Outlet 62.3 60.8 70.9 69.3 69.5 70.3 61.9 62.8 57.9 Breakout 53.1 53.7 61.8 61.4 53.4 54.5 44.9 41.9 41.3 100 Inlet 54.1 55.5 59.4 61.8 62.7 58.9 49.7 45.8 45.3 Outlet 63.1 61.8 67.8 72.7 70.5 71.5 62.9 64.4 59.0 Breakout 56.5 54.3 60.8 65.6 54.0 54.6 46.3 42.3 43.7

49 Integral Humidistat •Simple Plug-n-Play installation •Eliminates the need for additional controllers or sensors •Reacts to any rapid increases in relative humidity or when humidity rises above adjustable threshold •Future proof – can be fitted after installation •Self programmingStock Ref£Trade 43759845.55 Ambient Response Humidity Sensor •Pullcord override and indication light •Changeover relay switch •Operating range: 30% - 90%RH •Ambient operating temp. 5°C to 40°C •220-240V AC •Will fit single gang box for surface mounting Stock Ref£Trade 563550200.83 Visonex PIR Sensor •Fits any UK single gang mounting box •Adjustable timer overrun (5-25 mins) •Range of detection up to 10 metres •Designed to meet IP43 •Ambient operating temp. range 0°C to 50°C Stock Ref£Trade 459623115.70 Wireless Transmitter Controller Receiver Kit •Manual boost•Adjustable overrun timer•Easy wireless installation •Reduces installation time •Future proof - add more controllers any timeStock Ref£Trade 43935291.11 Ecotronic Humidity Sensor•Set point adjustable •Maximum switching load 1 Amp inductive •Pullcord override indicator •Ambient operating temp. 0°C to 40°C •Supply voltage 220-240V Stock Ref£Trade 563532111.57 CO 2+ Temp Room SensorIND •240V DC •0 - 2000ppm CO 2working range •0 - 50°C working range •Auto-calibrating NDIR CO 2absorption sensor •Thin film platinum temperature sensor for high accuracy Stock Ref£Trade433257577.47 Wireless Transmitter ControllerCAS •Additional controller for 439352 •A maximum of 4 controllers can be used per system •Can be connected to other accessories (e.g. Humidistat) to send a boost signal wirelessly Stock Ref£Trade 43782753.16 Air Quality SensorGEN •Ambient operating temp. 0°C to 50°C •DEMKO approved •Surface mounted •1 - 25 min O/R timer •Supply voltage 220-240V Stock Ref£Trade 563506223.74 VentwiseCAS •Automatically boosts fan when temperature of the supply pipe to a shower or bath increases •Automatically boosts fan when electric hob is switched on •Can be used in conjunction with manual override input •Adjustable overrun timer •Two sensor options available Stock Ref£Trade 435960391.10 Controllers and Sensors Sentinel Multivent can be used with a wide range of Vent-Axia controllers and sensors. Ranging from integral humidistats, through to wireless controllers to wired remote sensors.

50 With growing concerns about accurate ventilation of properties, the Lo-Carbon Multivent MVDC range offers the option of ‘Close Control’ both in the residential and the commercial sectors. With a DC motor the multi speed Lo-Carbon Multivent is one of the most efficient central extract units available. The units have two fully variable speeds for trickle and boost, with a switched live (LS) activation for the boost speed. An additional third speed (purge) is available using a second switched live connection. An acoustic lining is included as standard, ensuring minimum noise levels. The potentiometer controlled speed selector allows accurate setting of airflow, ensuring exactly the right ventilation rate. This feature also reduces noise, and energy consumption. ModelsCASStock Ref£Trade MVDC-MS437634356.69 MVDC-MSH443298385.33 SAP PCDB Test Results Exhaust TerminalTotal Configuration Flow Rate SFP (W/l/s) K + 121 0.16 K + 2 29 0.15 K + 3 37 0.17 K + 4 45 0.20 K + 5 53 0.24 K + 661 0.28 Lo-Carbon Multivent MVDC-MS/MSH •Best in class Specific Fan Power•Reduces your carbon footprint •Recognised in SAP PCDB •Fitted with four extract 125 or 100mm diameter spigots allowing quickconnection to ducts •Complies with Building ADF (System 3) •Option of wall, ceiling and loft mounting •Improved controllability •Switched Live Boost connection •Fully variable normal and boost speeds •Ultra quiet - acoustically lined for low noise levels •Integral humidistat (H version)

51 Dimensions (mm) Weight: 5.50kgA J I E C B Ø125H D F G Reduction Pieces Diameter: 100/125mm A B C D E F G H I J 340 72.5 25 15 360 214 310 249 150 85 Performance Guide MVDC-MSH features an integral humidistat which triggers the unit to boost when humidity levels in the duct system exceed 70%. 0 50 100 150 200 250 300 350 400 450 0 20 40 50 0 200 200 250 300 100 150 350 400 450 60 80 100 120 140 l/s m 3 /h Static Pressure (Pa) Volume 1 1 Min Speed Max Speed Fully adjustablespeed settings 2 2 Min Max ModelCasing Breakout dB(A) @ 3m Inlet Duct dB(A) FID l/s Power Watts Casing Breakout dB(A) @ 3m Inlet Duct dB(A) FID l/s Power Watts SEC Class SEC Class (inc. LDC) MVDC-MS 19 18 43 6 37 38 121 45 E B MCDC-MSH 19 18 43 6 37 38 121 45 E B

52 Lo-Carbon PoziDry •BBA approved •Reduces your carbon footprint•Selectable air capacities to suit floor area up to 150m 2 •Day logger feature as standard•Uses latest Lo-Carbon motor technology for low running costs •Ultra low sound level •Complete with ceiling diffuser, flexible duct and worm drive clips•Standard 5 year guarantee •Up to 5 year maintenance free G4 filter •IPX2 rated •SFP of 0.22W/l/s Positive Pressure Ventilation For controlling condensation particularly in the refurbishment sector, the BBA approved Lo-Carbon PoziDry offers a quick and simple solution. A loft mounted positive input fan draws fresh air from the insulated loft, filters it and gently feeds it into the dwelling via a ceiling mounted diffuser. Stale air in the property is forced out through the natural forms of ventilation, such as window mounted trickle vents. Installation The Lo-Carbon PoziDry can be installed in a loft space and can be suspended from a roof beam or be floor mounted, with a purpose-designed diffuser normally located over the stairwell of a conventionaltwo storey dwelling or in the main hall of a bungalow.The Lo-Carbon PoziDry is set to the appropriate speed at installation based on the size of the dwelling, providing positive pressure input ventilation. Background ventilation openings provide the exhaust points. Performance The robust construction of the Lo-Carbon PoziDry features a specially developed Lo-Carbon DC fan/motor arrangement which runs quietly and delivers incredibly low running costs. The Lo-Carbon PoziDry uses a sensor to monitor the temperature in the loft, automatically adjusting the air volume when necessary. ‘Trickle’ speed is automatically selected when the ambient loft temperature is up to 18°C. ‘Normal’ is automatically selected when the ambient loft temperature is between 18 and 27°C providing partial heat recovery. If the ambient loft temperature exceeds 27°C, the Lo-Carbon PoziDry will automatically switch to standby (no airflow). The standby power consumption is 2W.In the case of the integral 500W heater version, the heater element is automatically activated when necessary and tempers the supply air to 10°C. Can be used for air replacement in conjunction with an extract fan. Filter The unit includes a G4 filter with up to 5 years maintenance intervals to reduce the number of call outs needed throughout it’s life span. Day logger As standard. Measures the number of days the product has been switched on to provide precise running information. Speed Control With selection of 2 of 6 speeds available up to 50l/s, the unit is suitable for houses up to 360m 3 .Heater An optional comfort heater is available for operation when the incoming air temperature becomes low.Air Replacement Grille Set For air replacement through doors. Consists of a two-piece telescopic set, which fits unobtrusively on either side of the door panel. Minimum fixing thickness 30mm. Plastic. Dimensions: 454 x 90mm. Typical Specification The unit should be mounted in the loft space with a diffuser in self-extinguishing ABS positioned at the top of the stairwell. The unit meets the EMC and low voltage directives. Motor The electronically controlled DC motor is manufactured with long life ball bearings and is fitted with Standard Thermal Overload Protection (S.T.O.P.). Suitable for ambient operating temperatures of -25°C to +40°C.15/5180

53 For complete peace of mind, the Vent-Axia Lo-Carbon PoziDry is backed by a 5 year guarantee. Models Without heater DOM Stock Ref £Trade 444075415.44 With integral heater DOM Stock Ref £Trade 444766444.08 Accessories Twin Spigot Kit DOMAn additional kit to allow an extra circular diffuser to be installed near thePoziDry unit.Stock Ref£Trade 44907161.86 Includes:1 x436592(200mm Duct)2 x561707(Worm Clips)1 x452085(200mm equal Y Piece) 1 x10544200(Diffuser)Dimensions (mm) A B C DØ A B (depth) C DØ Weight 438 411 379 200 11.5kg Performance Guide Speed FID (l/s) Power (W) Floor Area up to (m 2 ) 1 10 2.5 30 2 18 3 54 3 26 4 78 4 34 5 102 5 42 7 126 6 50 13 150 add 500W for heater version Sound Data Octave band, Hz, dB SWL SPL dB(A) Setting Test mode 63 125 250 500 1k 2k 4k 8k at 3m Speed 1 Supply 33.2 28.3 25.4 15.3 17.2 12.6 16.4 22.7 8.5 Breakout/Intake 36.7 25.3 26.9 16.1 28.6 30.4 18.4 23.8 13.5 Speed 6 Supply 40.7 41.8 39.7 32.7 33.3 18.9 16.7 22.8 19 Breakout/Intake 39.7 37.0 43.9 41.1 37.6 32.5 27.1 26.1 22.0

54 Lo-Carbon PoziDry Compact •BBA Approved •Ultra low sound level •Selectable air capacities to suit volumes of up to 34 l/s orfloor area up to 100m 2 •Extremely low running costs - from less than one pence per day •Washable, high capacity G4 filter •Datalogger feature as standard•Round to rectangular duct adaptor included •5 Year Guarantee •Ideal for flats Positive Pressure Ventilation For those properties that do not have a loft, the BBA approved Lo-Carbon PoziDry Compact provides an easy to install solution. The unit is duct mounted and can be fitted in a number of locations within a single floor flat or apartment.Air is drawn into the Lo-Carbon PoziDry Compact unit via an external inlet and through a short length of duct. The specially developed fan/motor assembly (using the Lo-Carbon DC motor technology) draws the air through an integral, high capacity, washable filter. The backward curved impeller guarantees increased efficiency, lower sound levels and better performance. The fresh, filtered airflow passes along the ducting and terminates on an internal wall with a discreet grille. This directs the airflow upwards where the incoming air mixes with the warm air that gathers at ceiling height. The system provides fresh, tempered air into the home and creates an indoor environment where the damaging effects of condensation find it hard to exist, benefiting both the occupants and the structure of the building.The Lo-Carbon PoziDry Compact can be used for air replacement in conjunction with an extractor fan. A G4 filter is included as standard.Performance The Lo-Carbon PoziDry Compact uses a sensor to monitor the ambient temperature, automatically adjusting the air volume when necessary and providing partial heat recovery.‘Trickle’ speed is automatically selected when the ambient temperature is up to 18°C.‘Normal’ is automatically selected when the ambient temperature is between 18 and 27°C.If the ambient temperature exceeds 27°C, theLo-Carbon PoziDry Compact will automatically switch to standby (no airflow). The standby power consumption is 2W.In the case of the integral 300W heater version, the heater element is automatically activated when necessary and tempers the supply air to 10°C.Air Replacement Grille Set For air replacement through doors. Consists of a two-piece telescopic set, which fits unobtrusively on either side of the door panel. Minimum fixing thickness 30mm. Plastic. Dimensions: 454 x 90mm. See Ducting section. Day logger As standard. Measures the number of days the product has been switched on to provide precise running information. Model Without heaterCAS Stock Ref £Trade 444076508.54 With integral heaterCAS Stock Ref £Trade 444767 537.19 15/5180

55 Dimensions (mm) A B DØ C E G F H IØ J Duct Adaptor (included) Rear duct entry option A B C DØ E F G H IØ JUnit Weight 435 365 490 100 160 58 160 180 105 55 x 110 7kg Performance Guide Speed FID (l/s) Power (W) Floor Area (m 2 ) SEC Class 1 10 5.7 30 E 2 18 12.2 54 3 26 24.6 78 4 34 49.8 100 add 300W for heater version Sound Data Octave band, Hz, dB SWL SPL dB(A) Setting Test mode 63 125 250 500 1k 2k 4k 8k@ 3m Speed 1 Supply 37.6 32.7 33.4 35.0 29.8 27.5 18.2 22.6 18.0 Extract 37.0 32.3 32.5 32.4 21.9 25.3 16.8 22.6 15.5 Breakout 35.3 46.9 38.8 33.1 22.9 22.2 17.8 23.3 15.0 Speed 4 Supply 65.2 57.2 60.8 67.6 62.2 59.7 50.8 41.2 50.0 Extract 60.8 51.7 58.5 62.1 56.1 56.4 45.2 37.9 45.5 Breakout 57.2 55.2 55.5 63.3 55.1 52.2 44.1 32.9 41.5 Installation PacksCAS Stock Ref 453546 453547 453548Quick Fit Grille (White) 1 1 1 Wall fitting kit (Brown) 1 1 1 Round to Rectangle Adaptor 1 3 3 Vertical 90° bend2 2 2 Elbow/Spigot 1 1 1 1m Flat Channel1 2 2 1.5m Flat Channel1 2 2 Connector 1 4 4 Horizontal 90° Bend- - 2 Channel Clip4 6 2 £Trade 53.15 70.32 76.22

Residential & Commercial Single Room dMVHR Improving air quality on a room-by-room basis, the Vent-Axia through-the-wall mounted range of heat recovery ventilation units simultaneously extract stale air and introduce fresh air – warming the incoming airflow with heat recovered from the exhaust stream.Lo-Carbon TempraThe Vent-Axia Lo-Carbon Tempra through-the-wall heat recovery unit provides a flexible solution, which meets the requirements for high efficiency ventilation. Tempra is ideal for refurbishment projects and is designed for use in bathrooms, toilets, utility rooms and kitchens. Tempra also meets the current Building Regulations Approved Document F and L.

Lo-Carbon Tempra/SELV 58-59 HR200WK 60-61 HR300 62-63

58 Lo-Carbon Tempra/SELV•Fits in 100mm diameter hole – ideal for refurbishments •Up to 78% heat recovery •Available in 2 wall depths: 320mm and 460mm •Reduces the home’s carbon footprint •IPX4 rated •Summer setting (extract only) •Helps prevent noise ingress •Continuous running or intermittent extract •Meets current Building RegulationsApproved Documents F and L•Low power consumption - only 3.2 W Through-The-Wall Heat Recovery Unit The Vent-Axia Lo-Carbon Tempra is designed to fit in 100mm diameter hole and is suitable for refurbished properties in kitchens, bathrooms, toilets or utility rooms. The unit meets the performance requirements for continuous extract fans under the current Building Regulations Approved Document F.The Tempra is available in three models, a P version with pullcord control, a T version with overrun timer and an HTP version with built-in pullcord, overrun timerand humidistat. Two spigot lengths are available; 320mm and 460mm. The manual summer setting allows the unit to be set to extract only, helping to prevent a dwelling becoming too warm in hot summer conditions. Performance Tempra can be set to run continuously at 6 l/s or 9 l/s, boosting up to 15 l/s, recovering heat from extracted air and returning it to the dwelling. The unique, compact heat exchanger has a temperature efficiency up to 78%, saving energy and reducing your carbon footprint. For intermittent extract the Tempra is set to 15 l/s. The Tempra is also designed so that the replacement air being introduced is at a reduced rate ensuring that the room being ventilated is still under a slight negative pressure. This ensures that fresh air is bought into the room from the rest of the house preventing humid air migrating. The Lo-Carbon EC/DC motor with twin impellers consumes as little as 3.2 Watts on trickle rate and runs almost silently at only 20dB(A).Typical Installation The unique heat exchanger design allows the Tempra to be fitted in a 100mm diameter hole, allowing it to replace standard 100mm extract fans while giving all the benefits of heat recovery. Maximum wall thickness is 460mm. A longer version of the Tempra is available, designed for installations where the wall thickness is between 321mm and 460mm. 460mm models are identified by an ‘L’. ModelsLo-Carbon Tempra P (Pullcord)Constant trickle speed with pullcord to boost or intermittent operation by pullcord.ModelStock Ref£Trade 320mm P443312186.23 320mm SELV P444368231.26460mm LP403832186.23 460mm SELV LP403833231.26 Lo-Carbon Tempra T (Timer)Constant trickle speed with switch live to boost or intermittent operation by switch live.ModelStock Ref£Trade 320mm T443310243.52 320mm SELV T444369274.90 460mm LT403834243.52 460mm SELV LT403835274.90 Lo-Carbon Tempra HTP (Humidistat/Timer/Pullcord)Constant trickle speed with humidistat and linked overrun timer to boost or intermittent operation by switch live.ModelStock Ref£Trade 320mm HTP443311282.19 320mm SELV HTP444370313.57460mm LHTP403836282.19 460mm SELV LHTP403837313.57 Accessories100mm High Rise Kit 320mm white duct with black seal.ModelStock Ref£Trade 100mm High Rise Kit44901132.57 Wall kit Extendable Wall Tube suitable for both spigot lengths.ModelStock Ref£Trade Wall kit44552915.43

59 Dimensions (mm) A B C D E F GA B C D E F G Standard 266 190 262 117 496 99 321 Long 266 190 262 117 636 99 461 Performance Extract Performance l/s Power Consumption Watts Sound @dB(A) Model Trickle Low Trickle High Boost Trickle Low Trickle High Boost Trickle Low Trickle High Boost Lo-Carbon Tempra (All Models) 6 9 15 3.2 5.7 26.6 20 22 36 Octave band frequency range of 250Hz to 4KHz at 3m. Unit mounted on a reflective surface. Heat Exchange - what is heat recovery? Warm airfrom dwelling Coolair out Cold air in Warmed airreturned todwelling Stale Stale Fresh Fresh 150mm Conversion kit For replacement of 150 diameter fan.Stock Ref £Trade 40384728.66

60 Heat Recovery Ventilation The Vent-Axia HR200WK is a heat recovery ventilation unit specifically designed for use in domestic kitchens and utility rooms to meet the Building Regulations. The unit is also suitable for light commercial applications up to 220m 3 /h (50l/s). The compact, self contained unit is designed forthrough-the-wall mounting.The three speed, external rotor motor has two matched impellers to ensure a controlled airflow through the unit, with exceptionally economical 25 Watt low speed power consumption.Easy Installation The HR200WK fits through walls up to 335mm thick requiring a fixing hole 250mm square. The internal grille has washable, polymeric foam supply and extract filters. Only the neat internal twin grille is visible from the room. A wall extension sleeve is available for walls up to 550mm thick.Heat Exchanger The highly efficient, polymeric heat exchanger cube is washable. The compact cube interleaves outgoing moist warm air with incoming fresh air and allows the heat from one to warm the other without the two air streams mixing. Up to 75% of the heat, which would otherwise be lost, is transferred to the intake air, ensuring energy saving ventilation. Electrical HR200WK 220-240V/1/50Hz Class 1 earthed appliance. The 3 speed motor, can be wired to operate On/Off for any one of the three speeds. Alternatively, an Ambient Response Humidity Sensor or simple changeover switch can be used to provide switching between any two speeds, giving permanent trickle ventilation and automatic changeover to a higher speed during periods of high moisture generation. Also the 3 speed controller enables the unit to be switched from permanent trickle to either medium or boost speed. Models HR200WKA heat recovery unit specifically designed for use in domestic kitchens and utility rooms to meet the latest building regulations. 3 speed motor, trickle ventilation mode, optional range of switches available.ModelStock Ref£Trade HR200WK14120020 540.36 Accessories ModelStock Ref£Trade Extension Wall Sleeve37042185.45 Electronic ControllerW300310101.53 Controllers HR200WK ControllerA three position rotary control which enables the unit to be switched from permanent trickle ventilation to either medium or boost speed.ModelStock Ref£Trade HR200WK Controller56353341.59 SEC Class Rating Model SEC Class SEC Class (inc. LDC) HR200WK C A HR200WK•Single room domestic heat recoveryventilation unit •3 speed motor •Integral washable filter •Up to 75% heat recovery •Saves energy - controls condensation •Low noise

61 Dimensions (mm) B A D F C E Wall fixing hole 250mm x 250mm sq.A B C D E F 270 270 245 85 68min 335maxWeight 9.7kg Performance Performance l/s (m 3 /h) Watts % Heat Recovery Sound dB(A) @ 3m SEC Class SEC Class (inc. LDC) Extract IntakeSpeed 1 16 (60) 13 (50) 25 75 19 C ASpeed 2 30 (110) 27 (100) 60 70 33Speed 3 61 (220) 55 (200) 140 65 46

62 Heat Recovery Ventilation The HR300 provides ventilation with heat recovery. It is ideal for light commercial applications including function rooms, offices, classrooms etc. The HR300 unit comes complete with an integral shutter. Performance The HR300 unit is designed for continuous operation providing up to 70% heat recovery. Effectively lowering internal relative humidity the HR300 unit controls condensation and eliminates mould.Fresh, pre-warmed air from the outside is continually supplied to the room with simultaneous extraction of stale moist air and smells. Heat is transferred via a unique plastic heat exchanger from outgoing air to the fresh air supply with no cross contamination, maintaining internal temperatures and providing a fresh indoor environment. The unit is fully controllable for speed using a small dedicated speed controller. Automatic ON/OFF control or switching to boost is easily achieved using sensors/timers e.g. humidistat. For summer operation the heat exchanger can be removed and replaced with a plastic divider board to provide positive cooling to rooms.Installation The HR300 unit requires a 380mm x 280mm hole. Units should be level and square in the wall. The unit should be fitted so that it overhangs by a minimumof 50mm on the inside, and a minimum of 70mm on the outside. An extension sleeve is available for walls up to 650mm thick. Maintenance The heat exchanger should be washed in warm soapy water every twelve months, or as conditions necessitate. Access to the filter and heat exchanger is via two screws on the internal grille.Filters should be cleaned by washing every six months or as conditions necessitate. Replacement filters can be purchased in packs of two.Models ModelStock Ref£Trade HR300370394 493.64 Accessories ModelStock Ref£Trade Filters3704027.77 Extension Sleeve 37042247.24 Electronic ControllerW300310101.53 VCON6 Controller37035660.71 SEC Class Rating Model SEC Class HR300 B HR300 •Designed for continuous operation,providing up to 70% heat recovery •Controls condensation and eliminates mould •Speed controllable •Quiet operation •Washable filters

63 Dimensions (mm) A BC A B C 370 270 400 Weight 11kg Performance Extract Performance l/s (m 3 /h) Intake Performance l/s (m 3 /h) Max Sound dB(A) @ 3m SEC Class (inc. LDC) Model Low Normal Boost Low Normal Boost Watts Low Normal Boost SEC Class HR30020 (75)58 (210) 83 (300) 19 (70) 52 (190) 75 (270) 108 37 40 44 B A

MVHR forresidential & commercial applications Vent-Axia offers a complete range of Mechanical Ventilation with Heat Recovery (MVHR) units for residential and commercial applications, including many that are recognised in the SAP Product Characteristics Database.Lo-Carbon Sentinel Kinetic ®Advance The first of our new generation of MVHR systems incorporating a range of unique features. Offering units with wifi and App control options along with integrated digital controls for easy installation the range is designed with developers, specifiers and installers in mind. With over 93% efficiency and low specific fan powers down to 0.38 W/l/s; designers will see a reduction in their dwelling emission rate.

NEW Lo-Carbon Sentinel Kinetic ®AdvanceMVHR Unit 66-67 Lo-Carbon Sentinel Kinetic ®Range Overview 68-71 Lo-Carbon Sentinel Kinetic ®MVHR Unit 72-75 Lo-Carbon Sentinel Kinetic ®FHMVHR Unit 76-79 Lo-Carbon Sentinel Kinetic ®PlusMVHR Unit 80-83 Lo-Carbon Sentinel Kinetic® High FlowMVHR Unit 84-85 Lo-Carbon Sentinel Kinetic ®Cooker HoodMVHR Unit 86-89 Lo-Carbon Sentinel Kinetic ®HorizontalMVHR Unit 90-95 Lo-Carbon Kinetic ®Plus EMVHR Unit 96-99 IntegraDucted MVHR Unit 100-101 NEW Integra Plus EC Ducted MVHR Unit 102-103 HR100R/RSDucted MVHR Unit 104-105 HR200VDucted MVHR Unit 106-107 HR500Single Room Heat Recovery Unit 108-109 HR500DDucted MVHR Unit 110-111 HR500EP/IPPassive HR Unit 112-113 HR500DPPassive HR Unit 114-115

66 NEW Lo-Carbon Sentinel Kinetic Advance •Ultra quiet •Touch screen controller •Lightweight for easier installation •Full summer bypass •WiFi connectivity option •Wireless commissioning •Pre-commissioning via USB •App control option •Left/Right handing through the controller •Pre-heater option for cold climates •Post-heater control option •Developed and manufactured in the UK •G3, M5 and F7 filter options The Sentinel Kinetic ®Advance from Vent-Axia is the next generation ofheat recovery ventilation systems. It is designed to offer the highest level of comfort and control available ensuring the best possible customer experience. A whole new experience The highly sculpted interior surfaces, designed using the latest CFD techniques, ensures airflows are maximised through the unit minimising noise and energy use. This feature alone provides an experience which we are confident will delight home owners and fulfil our ambition of providing the most discrete and efficient ventilation available.With the widest range of options available, installers can now order a system that is tailored to their client’s needs.Air Quality and Health We have strived to make the Advance system the most flexible solution available on the market. Optimisation has been targeted in every aspect of the design to ensure that it really does improve quality of life. Whatever the outside environment, we a have a method to help reduce air pollution from entering the living space. Our range of filter options, up to and including F7, ensure that even homes in heavily urbanised areas have the opportunity to filter out the impurities and help protect their family from respiratory issues. Nuisance noise – There isn’t any… The most common concern with home owners is that ventilation devices create noise. With Advance, absolute optimisation of every element does everything possible to minimise generation and transmission of both motor and airflow noise. We believe that we have one of the quietest units available. Ventilation how you want it We have spent our time considering every element of the ventilation control. Should you want to run the system at certain times and at certainspeeds, all of the options are available for you. With a programmable controller, it is possible to boost the unit if required, for example during hot periods in the summer, or even reduce the speed if needed, perhaps when a baby is due to go to bed. Whatever the situation, Advance can be made to operate as needed. At the same time, automatic functions such as frost protection and summer bypass even have a choice of algorithms designed to suit different climates and lifestyles.Controllability With building services often hidden away in cupboards or in lofts we have developed a number of options for system control. From an App which provides instant access wherever you are, to full on-board touch screen controls, an option will be available to support your needs. SEC Class Model SEC Class Advance S/SX/SXp A+ Model ModelStock Ref£Trade Advance S4052151751.00 Advance SX4052162008.50 Advance SXp LH4740200.00 Advance SXp RH4740250.00 Accessories ModelStock Ref£Trade Wifi Controller40919599.91 Docking Kit for Wired Controller4744910.00 Volt-free Expansion (Four additional inputs)4726970.00 Switched Live Expansion (Two additional inputs)4726990.00 0V - 10V Input Board (Two inputs)4727010.00

67 Spare Filters ModelStock Ref£Trade G3 (2 pack)4726670.00 M5 Pollen Filter(1 pack)4726690.00 F7 Particulate Filter (1 Pack)4726710.00 Spigot Configuration SupplyRight Handed Exhaust Intake Extract Left Handed Exhaust SupplyIntake Extract Hand-able through controller (except if pre-heater fitted) Models Advance S Advance SX Advance SXp Sentinel Touch Screen Controller App Control O App Commissioning O Auto Summer Bypass Easy Access Filters G3 Filter M5, F7 Filter Options Very Low Noise Levels Built-In Humidistat Active Frost Protection to -20°C Delay-On Clean Filter Indicator (Time) Clean Filter Indicator (Pressure) X Fault Code Indicator Switched Live Volt Free 0V - 10V Proportional Control O O O Lightweight 22mm or 32mm Condensate Connection Left/Right Orientation Through Control X Ventwise Control O O O PIN Number Lock Running Time Indicator External Pre-Heater Controller O O X External Post-Heater Controller O O X Built-in Pre-Heater X X Enthalpy Heater Exchanger O O O Fan Curve Flow Constant Volume X Email Status Notifications X Soft-Start Boost Mounting Options Wall Surface O - Optional extra. Contact us for more information. SAP PCDB Test ResultsThermal Efficiency % SFP (W/l/s) K+1 93 0.38 K+2 93 0.38 K+3 92 0.42 K+4 92 0.50 K+5 91 0.58 K+6 91 0.68 K+7 90 0.82 Dimensions (mm)B C A D E F G H I J A B C D E F G H I J kg 760 660 443 63 343 210 503 197 93 125 27 Packed weight: 32kg Performance 0 100 200 300 400 500 600 700 0 050100 150 200 250 300 350 400 20 40 60 80 100 120 Static Pressure(Pa) Volume l/s m 3 /h 100% 60% 40% 80% 20% Sound Spectrum Octave Band (Hz) Sound Power Levels, dB SPL dB(A)@ 3m Speed Test mode 63 125 250 500 1k 2k 4k 8k 20% Extract 50.3 49 36 31.5 23.6 16.1 18.9 25.3 18.9 Supply 52.9 50.9 46.8 43 34.6 27.1 19.2 25.4 26.4 Breakout 30.7 28.3 32.2 26.9 18.6 15.3 17.9 21.5 8.4 40% Extract 51.9 51.3 50.4 41.2 35 25.3 19.8 25.4 27.3 Supply 59.5 56.5 59.4 55 48.2 42.6 31.8 26.1 38.4 Breakout 42.6 39.2 43.9 39.2 31.5 26.3 24.1 22 19.5 60% Extract 60.6 60.3 54.2 49.5 44.4 36.2 27.9 26.3 34.2 Supply 66.9 62.4 63.3 62 57.9 53.5 43.4 34.2 45.7 Breakout 60.2 49.5 48.2 47.4 40.2 35.7 33.3 28.7 27.1 80% Extract 75.5 68.6 59.3 56 48.3 44.2 36.9 31.3 41.1 Supply 82.4 67.6 65.2 67.6 64.2 60.8 50.8 43.2 51.7 Breakout 58 56.3 50.4 62 44.8 42.1 38.1 35.3 38.7 100% Extract 72.4 70.5 60.5 56.4 49.8 46.3 39 33.4 42.0 Supply 79.4 69.6 66.6 75.1 64.9 63.6 53.4 45.7 56.2 Breakout 64.9 54.4 51.4 57.8 46.2 43.8 39.7 36.9 35.6 Tested according to BS EN 13141-7:2010. Breakout quoted spherical. Supply and Extract quoted hemispherical.

68 Lo-Carbon Sentinel Kinetic Range Overview •Manufactured in the UK •Building Regulations ADF and ADL compliant •Recognised in SAP PCDB •Specific Fan Power down to 0.4 W/l/s •Up to 94% heat recovery •Fully automatic Summer bypass •Horizontal and/or vertical duct outlets •Integrated digital controller for simple and accurate commissioning •Lightweight for easy installation •External condensate connection •Plug and play controls; Humidistat, Ventwise, Wireless Remote The Sentinel Kinetic Range Incorporates: •A wholehouse heat recovery system with up to 94% energy efficiency•An easily accessible heat recovery cube protected by two removable G3 filters •Two Lo-Carbon energy saving EC/DC fans which ensure long life (typically over double the life of AC motors) and lowest possible energy use •Fully insulated construction with built-in condensation drain •Specifically designed for new build constructions with a high level of insulationThe Lo-Carbon Sentinel Kinetic meets the latest requirements of the Building Regulations ADF and ADL for wholehouse system ventilation: System 4 - Continuous mechanical supply and extract with heat recovery. The Lo-Carbon Sentinel Kinetic models have 3 fully adjustable speeds and a purge setting (maximum flow). Provided with the unit is a digital controller that can be used to preset the speeds to any required airflow within the performance range.Integral Humidity Sensor The integral humidity sensor (models with H suffix) increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. Thenight time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Optional M5 Supply FiltersKinetic B, BH & Cooker Hoods FilterStock Ref £Trade 44419923.56 Kinetic Plus Range Filter Stock Ref £Trade 44420135.67 For sensors see Accessories & Controllers section. Sentinel Control The Sentinel controller is the most advanced system available, providing Demand Control Ventilation (DCV), minimising energy consumption and noise levels, and optimising ventilation performance. Sentinel controlled units may be set to operate fully automatically or with varying levels of manual intervention. Building Management System (BMS) OptionsThere are two levels of BMS available: Basic Output and full Electronic BMS. Basic Output provides a 5 volt output from the LED terminals on the controller. This output occurs whenever a message appears in the digital display, for example; ‘Check Filters’ or a fault code. The output can also be converted to volt-free with the addition of an optional Opto-Coupler. Electronic BMS: A full range of two-way digital signals are available through the RJ11 connector on the control board. The BMS system provider will translate this signal to extract the desired data. ContactVent-Axia to discuss your specific requirements.LEDAlarmMVHR units are often installed in lofts or other locations where they are difficult to monitor. The optional remote LED alarm illuminates when any message is visible in the MVHR unit display panel. The LED alarm can be installed in a convenient location within the dwelling allowing end users to see that the unit requires attention. Control Inputs Five volt-free pairs of switch terminals for sensor inputs allow boosting from a full range of Vent-Axia controllers – humidistats, PIR, timers. Two terminals with 0-24V outputs allow 0V to 10V proportional control by sophisticated controllers such as CO 2sensors and proportionalhumidistats.

69 The optional Ventwise controller senses temperature rise in a bath/shower hot water supply and/or current in a cooker/hob electrical circuit to activate boost, ensuring additional ventilation when needed. Switched-live for boosting via light switches (220-240 V AC) or manual Normal/Boost switches. This connection has the advantage of Delay-On and Delay-Off facility. Delay-On enables you to prevent the Boost airflow between 0 and 10 minutes, after a light switch has been activated. Delay-Off allows the Boost airflow to continue after a light switch is turned off to ensure effective clearance of humidity. This timer is adjustable between 0 and 25 minutes. The units can be boosted incrementally via the on-board controller or the Wired Remote Controller: One press = 30 minutes, two presses = 60 minutes, three presses = continuous. Optional Controls LED Alarm with 15 metre cableStock Ref £Trade 44835630.93 Wired Remote Controller with 15 metre cable Stock Ref £Trade 44328357.30 Wireless Enable Kit (includes one switch) Stock Ref £Trade 44186585.95 Additional Wireless Boost Switch(max 3 switches) Stock Ref £Trade 43782753.16 Ventwise Controller (also requires sensors, see Accessories & Controllers section) Stock Ref £Trade 441780193.38 Purge Setting The unit can be set to maximum flow (100%) by pressing and holding the Boost button on the unit itself or optional wired controller for 5 seconds. Purge will continue for two hours unless cancelled by pressing the Boost button again. Summer BypassAn internal damper operates when the external temperature is below the internal temperature, and the internal temperature is too high. The bypass opens and allows the cooler outside air to help cool the dwelling. Normal mode: Fans run on Normal speed with bypass open until the internal dwelling temperature falls below the set 'Indoor' (maximum desired) temperature.Evening Purge mode: The fans run on Boost speed until the internal temperature falls below the set 'Indoor' temperature. If, after five hoursthe internal temperature is still above the set 'Indoor' temperature, the unit will switch down to normal speed for the remainder of the 'bypassopen' period. Night-time Purge mode: As Evening Purge, except that the unit will continue on Boost speed until the internal air temperature reaches the 'Outdoor' temperature set point (Default 14°C). This mode gives pre-cooling of the dwelling for the following day. In Evening and Night Time Purge modes, the user can turn off the boost function by pressing the Boost button. A Summer Bypass can make a contribution to reducing internal temperatures but is not a substitute for appropriate design and construction.Frost ProtectionIn order to prevent frost forming inside the unit in winter conditions, the Kinetic range employs a sophisticated frost protection strategy that modifies the airflows ensuring heat recovery continues down to -20°C. Below this temperature, the units will operate as 'extract only' fans. If balanced ventilation is required at low temperatures, a duct pre-heater should be used. System Cooker Hood Range System canopy hoods are a motorless hood with extract being provided by the MVHR unit. When the Boost button on the canopy is activated, the MVHR unit goes to boost setting and the summer bypass opens preventing cooking by-products entering the heat exchanger cell. White Pull-out System HoodStock ref £Trade 407509255.10 Aluminium Pull-out System HoodStock ref £Trade 407206272.28 Wired Remote ControllerStandard with horizontal units, optional extra with vertical units. Supplied with 15 metres of cable (max length), the Wired Remote Controller duplicates all the features of the on-board control panel, allowing commissioning, diagnosis and user control. Flush mounting, suitable for a single gang pattress box 16mm deep.

70 Model Range OveriewSentinel Kinetic Range Kinetic E Range Model Ranges Lo-CarbonSentinel Kinetic Lo-CarbonSentinel Kinetic F Lo-CarbonSentinel KineticPlus Lo-CarbonSentinel KineticHigh Flow Lo-CarbonSentinel KineticCooker Hood Lo-CarbonSentinel KineticHorizontal Lo-CarbonKinetic Plus E Models V B BH F Plus High Flow CH 200ZP/ZPH 300ZH 200Z/ZH/ZMH Plus E Auto Summer Bypass Easy Access Filters Very Low Noise Levels Integral Cooker Hood Built-In Humidistat Kitchen Cupboard Installation Max Airflow @ 100Pa 68 68 68 79 117 185 68 37 81 50 117 Frost Protection Delay-On Wired Remote Control O O O O O O O Wireless Boost O O O O O O O O O O Clean Filter Indicator (Time) Fault Code Indicator Potentiometer Adjustment Sentinel Control Switched Live Volt Free Contact 0V - 10V Proportional Control BMS Input/Output 1 1 1 1 1 1 1 1 1 1 Lightweight External Condensate Horizontal Duct Option Horizontal (Slab) Installation Left/Right Orientation Ventwise Control PIN Number Lock Running Time Indicator Enthalpy Heater Exchanger O O O O O Mounting Options Wall Surface Wall Surface Wall Surface Wall Surface Wall Slab Wall Surface O - Denote Optional, 1- Seek technical advice from Vent-Axia. ZMH rectangular spigot model.

71 Sentinel Demand Control The Lo-Carbon Sentinel Kinetic Range can be used with a wide range of optional Vent-Axia controllers and sensors. Ranging from integral humidistats, through wireless controllers to wired remote sensors. Wired Remote Controller •Standard with horizontal units, optional extra with vertical units•Supplied with 15 metres of cable (max length), the Wired RemoteController duplicates all the features of the on-board control panel, allowing commissioning, diagnosis and user control•Flush mounting, suitable for a single gang pattress box 16mmdeep Stock Ref£Trade 44328357.30 Wireless Transmitter Controller Receiver Kit•Manual boost •Adjustable overrun timer •Easy wireless installation•Reduces installation time•Future proof - add more controllers at any time Stock Ref£Trade 44186585.95 Wireless Transmitter Controller•Additional controller for 441865•A maximum of 4 controllers can be used per system•Can be connected to other accessories (eg Humidistat) to send aboost signal wirelessly Stock Ref£Trade 43782753.16 Ambient Response Humidity Sensor •Pullcord override and neon indicator•Changeover relay switch•Operating range: 30% - 90%RH•Ambient operating temp. 5°C to 40°C•220-240V AC•Will fit single gang box for surface mountingStock Ref£Trade 563550200.83 Ecotronic Humidity Sensor •Set Point adjustable•Maximum switching load 1 amp inductive•Pullcord override indicator•Ambient operating temp. 0°C to 40°C•Supply voltage 220-240VStock Ref£Trade 563532111.57 Air Quality Sensor •Ambient operating temp. 0°C to 50°C•Min - Max mode or direct damper control•Surface mounted•1 - 25 min O/R timer•Supply voltage 220-240VStock Ref£Trade 563506223.74 Normal Boost Switch•A single gang switch to boost from low to high speeds on heatrecovery systems •85x 85 x 10mm (H x W x D)Stock Ref£Trade 45521338.34 Visonex PIR Sensor •Fits any UK single gang mounting box•Adjustable timer overrun (5-25 mins)•Range of detection up to 10 metres•Designed to meet IP43•Ambient operating temp. range 0°C to 50°CStock Ref£Trade 459623115.70 CO 2+ Temp Room Sensor•240V DC•0 - 2000ppm CO2 working range•0 - 50°C working range•Auto-calibrating NDIR CO22•Thin film platinum temperature sensor for high accuracyStock Ref£Trade433257577.47 Ventwise •Automatically boosts fan when temperature of the supply pipe toa shower or bath increases •Automatically boosts fan when electric hob is switched on•Can be used in conjunction with manual override input•Adjustable overrun timer•3 sensor inputsStock Ref£Trade 441780193.38 Momentary Push Switch•Compatible with Sentinel Kinetic range, the momentary switchboosts the unit for 30 minutes •85 x 85 x 10mm (H x W x D)Stock Ref£Trade44892920.05 Normal Boost Switch with Light Indicator•Single gang switch with LED illumination when in the Boost condition•85 x 85 x 10mm (H x W x D)Stock Ref£Trade44906038.34 Normal Boost Switch- Stainless Steel A single gang switch to operate normal/boost functions on MVHR systems•Brushed stainless steel finish•90 x 90 x 18 (H x W x D)Stock Ref£Trade43732046.72 Isolator Relay Controller•Allows fan unit to be isolated from other mains circuit when used withTIM2 trickle/boost switch or light switch control Stock Ref£Trade 44203064.46

72 Lo-Carbon Sentinel Kinetic •Recognised in SAP PCDB •Ultra quiet •Lightweight for easier installation•Horizontal duct option for space-saving installations •Fits within a 290mm deep kitchen cupboard •Integrated digital controller for simple and accurate commissioning •Plug and play controls; Humidistat, Ventwise, Wireless Remote •BMS connectivity •LS inputs (Light Switch) •Horizontal duct options Easy Installation The Sentinel Kinetic models can be mounted vertically in a roof space, hallway cupboard or kitchen or within a kitchen cupboard. When mounted in an unheated area ducting and MVHR unit should be insulated. Ducting can be attached to the unit horizontally, vertically or both. Minimum internal depth of kitchen cupboard: V, B & BH models 290mm. Left (L) or right (R) hand installation. The unit is supplied with duct spigots to outside on the right hand side. These can be reversed on site by simply removing the control panel, rotating the unit 180 degrees and re-attaching the control panel.Spigot Options The combination of spigot options allows installation in confined locations. If vertical and horizontal connection is required on the same outlet/inlet, additional spigots can be supplied. The condensate drain can be taken out through the back, side or bottom of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation. Integral Humidity Sensor (BH Models) The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. ModelsModelStock Ref£Trade Kinetic V 4383421339.37 Kinetic B Right4382221425.33 Kinetic B Left438222L1425.33 (with summer bypass) Kinetic BH Right4433191511.28 Kinetic BH Left443319L1511.28 (with summer bypass & humidity sensor)B & BH models available in left hand or right hand configurations (L). AccessoriesModelStock Ref£Trade Wired Remote Controller44328357.30 Wireless Enable Kit44186585.95 Wireless Transmitter43782753.16 ControllerVentwise Controller441780193.38 LED alarm with 15m cable44835630.93 Kinetic V, B & BHStock Ref£Trade Kinetic Spare Filter 2 pk44235623.56 M5 Pollen Filter44419923.56 SAP PCDB Test Results (Kinetic V) ThermalEfficiency % SFP (W/l/s) K+1 90 0.60 K+2 90 0.59 K+3 90 0.68 K+4 89 0.79 K+5 90 0.97 SEC Class Model SEC Class Kinetic V/ B/BH A

73 Dimensions (mm)G C B A D EØ F A B C D EØ F G 550 550 285 140 125 360 90 Weight: 15kg Performance Fan speeds are fully adjustable within the performance range. 0 100 200 300 400 Static Pressure (Pa) 20% 40% 60% 80% 100% 0 100 200 300 400 S tat icP res sur e ( P a ) Volume Volume 010 20 30 40 50 60 70 80 010 20 30 40 50 60 70050100 150 200 250 050100150200 250300 53 27 20 30 44 128 107 20% 40% 60% 80% 100% m 3 /h l/s m 3 /h l/s 13 96 82 58 x figure relates to Wattage (both motors) x figure relates to Wattage (both motors) 12 49 26 18 25 38 118 97 89 75 54Example system curves -vertical spigotsExample system curves -horizontal spigots Sound Data (Kinetic B & V) Octave band, Hz, dB SWL SPL dB(A) Flow l/s Test mode 63 125 250 500 1K 2k 4K 8K@ 3m 10 Supply 47.8 40.2 38 31.1 28.2 22.1 23.6 30.9 21.4 Extract 47 38.7 36 29.9 25 22.4 23.3 30.8 20.6 Breakout 43.6 36.2 37.4 30.9 27.4 23.3 24.2 31.4 18.6 20 Supply 54 46.6 50.2 44.5 44.4 38.3 28.8 31.9 31.2 Extract 46.8 40.5 34.6 34.2 34.6 25.9 23.7 30.3 22.9 Breakout 45.9 39.9 40.6 35.7 33.5 28.4 25.3 31.2 21.3 30 Supply 58.1 54.5 57.6 52.2 51.7 47.6 38.6 35.8 38.5 Extract 47.6 46.2 38.7 41.3 42.8 33.9 26.4 30.5 28.4 Breakout 45.2 42.4 48.2 40.8 37.7 35.2 30 31.1 25.2 40 Supply 65.2 58.4 62.3 58 56.5 52.5 44.1 41.4 43.6 Extract 53.5 53 44 47.7 48.1 39.7 31.5 31.5 33.5 Breakout 50.9 47.6 47.4 48.1 42.5 40.8 36.3 34.4 29.3 50 Supply 66.4 63.2 66.3 62.5 61.7 57.4 50 47.8 48.3 Extract 64.2 55.2 48 50.9 52.1 44.5 35.9 35 37.2 Breakout 55 51 51.3 51.6 46.9 46.0 42 38.3 33.2 Tested according to BS848. Breakout quoted spherical. Supply and Extract quoted hemispherical.

74 Consultant's Specification (B and BH Models)OperationThe supply and extract ventilation unit shall be a Sentinel Kinetic as manufactured by Vent-Axia and shall be sized as indicated on the drawings and shall be in accordance with the particular specification.Supply air to the room shall be pre-heated by the extract air via the integrated composite plastic counterflow heat recovery cell. The Sentinel Kinetic shall automatically vary the ventilation rate via EC/DC motors, as it receives signals from one of the optional interconnected sensors. When a signal is received, the fans shall either vary their speed proportionally or on a trickle and boost principle. The unit shall have the facility to commission the supply and extract fans individually via in-built minimum and maximum speed adjustment, or alternative wired remote control unit. The fans themselves shall have independent, infinitely variable speed control. Unit SpecificationThe unit shall be manufactured with an ABS outer case construction, and incorporate a reversible core to allow for left or right hand mounting. The unit shall have a high efficiency composite plastic counterflow heat exchanger, supply and extract filters, automatic summer bypass, (B/BH) integral minimum and maximum infinitely variable speed controls with facia mounted failure indication. The unit shall have low energy, high efficiency EC/DC fan/motor assemblies with sealed for life bearings. The impellers shall be high efficiency forward curved centrifugal type. The unit shall have a heat exchanger cell with a thermal efficiency of up to 92% when tested to EN 308. This shall be protected by G3 grade synthetic filters on supply and extract. Complete with a condensate drip tray and drain connection. The unit shall be constructed with a removable Core allowing full maintenance access. The removable Core shall provide access to the following:Supply and extract filterHeat exchangerAccess to the electrical connections Access shall be provided for wiring termination and setup/commissioning. The backlit LCD user interface therein shall be removable for remote mounting if required. Units shall be as manufactured by Vent-Axia Ltd. Standard ControlsAll Sentinel Kinetic units shall incorporate the following functions integrally mounted, pre-wired and factory fitted by the manufacturer: Integral infinitely variable fan speed control onsupply and extractIntegral min/max ventilation control/set pointIntegral BMS interfaces – control and statusindicationHeating interlocks0-10V proportional speed adjustmentVolt free contacts24V sensor supplyIntegral on/off or trickle boost function fromremote switch e.g. PIRoccupancy detectorThe unit shall be controlled by the ‘Sentinel’control devices(enablers and sensors) asdetailed in the schedule or on the drawingsFully automatic summer bypassSwitched Live input with adjustable ‘delay-on’featureFan failure or component failure indicated viaindividual fault codedisplayRunning time counterControl panel PIN number lockAutomatic frost protection effective to -20°CTool free filter accessThe unit shall incorporate (‘H’ models) anintegral humidity sensorwith the following features: •Ambient Response; Raises the humidity trigger point as dwelling temperature reduces •Rapid Response; Monitors the rate of change in humidity and triggers increased airflow even if the humidity trigger threshold is not reached •Proportional Response; Incrementally increases the fan speed to reduce noise and reduce energy consumptionMounting Option Wall Surface

75 Airflow DirectionDuct extract from dwelling (Yellow) Acoustic duct (Optional)supply to dwelling (Red) Insulated duct from atmosphere (Green) Insulated duct exhaust to atmosphere (Brown) Front (RH) Duct extract fromdwelling (Yellow) Acoustic duct (Optional) supply to dwelling (Red) Insulated duct fromatmosphere (Green) Insulated duct exhaust toatmosphere (Brown) Front (LH) Plan View Electrical Connection (B and BH Models) Please note: Electrical connection should be carried out by an appropriately qualified person and in accordance with current wiring regulations. Trickle to Boost by Trickle/Boost switch

76 Lo-Carbon Sentinel Kinetic FH •Ultra quiet •Lightweight for easier installation•Horizontal duct option for space-saving installations •Integrated digital controller for simple and accurate commissioning •Plug and play controls; Humidistat, Ventwise, Wireless Remote •BMS connectivity •LS inputs (Light Switch) •Volt-free inputs •Self diagnosis for simplified fault finding •Adjustable delay On/delay Off timer sioning ote Easy Installation The Sentinel Kinetic models can be mounted vertically in a roof space or in an appropriate cupboard within the dwelling. When mounted in an unheated area the ducting and unit must be insulated in accordance with the Domestic Ventilation Compliance Guide. Ducting can be attached to the unit horizontally, vertically or both. Left (L) or right (R) hand installation. Left hand and right hand units are available.Spigot Options The combination of spigot options allows installation in confined locations. If vertical and horizontal connection is required on the same outlet/inlet, additional spigots can be supplied. The condensate drain can be taken out through the back, side or bottom of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation. Integral Humidity Sensor The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Model ModelStock Ref£Trade Kinetic FH Right4081671545.00 (right handed with summer bypass & humidity sensor)Kinetic FHL Left4081691545.00 (left handed with summer bypass & humidity sensor)AccessoriesModelStock Ref£Trade Wired Remote Controller44328357.30 Wireless Enable Kit44186585.95 Wireless Transmitter Controller43782753.16 Ventwise Controller441780193.38 LED alarm with 15m cable44835630.93 Kinetic F Spare G3 Filter 2pk4097640.00 Kinetic F Spare M5 Filters 2pk4721530.00 SAP PCDB performance ThermalEfficiency % SFP (W/l/s) K+1 90 0.53 K+2 89 0.51 K+3 88 0.56 K+4 87 0.65 K+5 85 0.75SEC Class Model SEC Class Kinetic FH/FHL A+

77 Dimensions (mm)D EØ F G C B A A B C D EØ F G 555 550 350 140 125 360 90 Weight: 18kg Performance Fan speeds are fully adjustable within the performance range. 1000 900 800 700 600 500 400 300 200 100 0 010 20 30 40 50 60 70 80 90 100Air VolumePressure Pa 050100 150 200 250 300 350 l/s m 3 /h 4 100%4 20%4 40%4 60%4 80%Sound Data Port Octave band, Hz, dB SWL SPL dB(A) Speed Test mode 63 125 250 500 1k 2k 4k 8k@ 3m 100% Extract 83.3 68.3 66.9 71.2 60.7 51.4 42.4 36.1 52.2 Supply 95.5 77.7 74 80.4 68.7 62.9 56.9 52.4 61.6 Breakout 62.1 59.7 62.9 70 61 57.3 52.3 46.9 47.5 80% Extract 83.5 65.2 65 65.5 57 47.7 37.9 31.3 48 Supply 85 75.3 72.5 77.9 65.3 58.8 52.1 47.4 58.5 Breakout 56.4 56.4 60.4 69.8 56.7 53.2 47.8 42 46 60% Extract 67.3 61.9 66.5 58.9 52.2 42.7 32.6 27.6 43.6 Supply 72.8 72.5 82.2 64.4 59.9 53.8 46.2 40.3 56.9 Breakout 53.9 53.2 65.9 55.8 52.2 48.2 42.5 39.3 40.5 40% Extract 66.8 56.1 56.9 52.1 44.7 34.6 23.8 25.8 35.7 Supply 68.9 66.4 68.8 57.8 52.1 44.9 35.3 28.8 44.9 Breakout 47.3 47.5 56.4 48 44 39.6 32.8 29.1 30.5 20% Extract 57.7 56.6 47.2 43.5 35.3 24.1 19.6 25.7 28.2 Supply 66.2 67.2 54.3 48 42.1 33.3 22.5 25.6 36.4 Breakout 41.2 47 41.7 39.5 34.6 30.4 22.5 25.7 20.5 Tested according to BS EN 13141-7:2010. Breakout quoted spherical. Supply and Extract quoted hemispherical.

78 Consultant's SpecificationOperationThe supply and extract ventilation unit shall be a Sentinel Kinetic as manufactured by Vent-Axia and shall be sized as indicated on the drawings and shall be in accordance with the particular specification.Supply air to the room shall be pre-heated by the extract air via the integrated composite plastic counterflow heat recovery cell. The Sentinel Kinetic shall automatically vary the ventilation rate via EC/DC motors, as it receives signals from one of the optional interconnected sensors. When a signal is received, the fans shall either vary their speed proportionally or on a trickle and boost principle. The unit shall have the facility to commission the supply and extract fans individually via in-built minimum and maximum speed adjustment, or alternative wired remote control unit. The fans themselves shall have independent, infinitely variable speed control. Unit SpecificationThe unit shall be manufactured with an ABS outer case construction, and incorporate a reversible core to allow for left or right hand mounting. The unit shall have a high efficiency composite plastic counterflow heat exchanger, supply and extract filters, automatic summer bypass, integral minimum and maximum infinitely variable speed controls with facia mounted failure indication. The unit shall have low energy, high efficiency EC/DC fan/motor assemblies with sealed for life bearings. The impellers shall be high efficiency backward curved centrifugal type. The unit shall have a heat exchanger cell with a thermal efficiency of up to 90% when tested to EN 308. This shall be protected by G3 grade synthetic filters on supply and extract. Complete with a condensate drip tray and drain connection. The unit shall be constructed with a removable Core allowing full maintenance access. The removable Core shall provide access to the following:Supply and extract filterHeat exchangerAccess to the electrical connections Access shall be provided for wiring termination and setup/commissioning. The backlit LCD user interface therein shall be removable for remote mounting if required. Units shall be as manufactured by Vent-Axia Ltd. Standard ControlsAll Sentinel Kinetic units shall incorporate the following functions integrally mounted, pre-wired and factory fitted by the manufacturer: Integral infinitely variable fan speed control onsupply and extractIntegral min/max ventilation control/set pointIntegral BMS interfaces – control and statusindicationHeating interlocks0-10V proportional speed adjustmentVolt free contacts24V sensor supplyIntegral on/off or trickle boost function fromremote switch e.g. PIRoccupancy detectorThe unit shall be controlled by the ‘Sentinel’control devices(enablers and sensors) asdetailed in the schedule or on the drawingsFully automatic summer bypassSwitched Live input with adjustable ‘delay-on’featureFan failure or component failure indicated viaindividual fault codedisplayRunning time counterControl panel PIN number lockAutomatic frost protection effective to -20°CTool free filter accessThe unit shall incorporate (‘H’ models) anintegral humidity sensorwith the following features: •Ambient Response; Raises the humidity trigger point as dwelling temperature reduces •Rapid Response; Monitors the rate of change in humidity and triggers increased airflow even if the humidity trigger threshold is not reached •Proportional Response; Incrementally increases the fan speed to reduce noise and reduce energy consumptionMounting Option Wall Surface

79 Airflow Direction Duct extract fromdwelling (Yellow) Acoustic duct (Optional)supply to dwelling (Red) Insulated duct from atmosphere (Green) Insulated duct exhaust to atmosphere (Brown) Front (RH) Duct extract from dwelling (Yellow) Acoustic duct (Optional) supply to dwelling (Red) Insulated duct fromatmosphere (Green) Insulated duct exhaust toatmosphere (Brown) Front (LH) Plan View Electrical Connection Please note: Electrical connection should be carried out by an appropriately qualified person and in accordance with current wiring regulations. BMS NET J4 4321 Ventwise connector Switches 1-5 Proportional Inputs 1&2 LED 3A 2m mains cable fitted to unit Brown Switched fused spur Blue LNLS E 220-240V 50Hz Green/Yellow Black S/W1 + - + - + - +- +- +S - +S - +- S/W2 S/W3 SW4 S/W5 P1 0-10V P2 0-10V LED L NLS Trickle to Boost by Trickle/Boost switch

80 Lo-Carbon Sentinel Kinetic Plus •Recognised in SAP PCDB •Ultra quiet •Horizontal duct option for space-saving installations •High airflow, ideal for student accommodation clusters •Unique folding filter for removal when access is restricted •Integrated digital controller for simple and accurate commissioning •Lightweight for easy installation •Plug and play controls; Humidistat, Ventwise, Wireless Remote •BMS connectivity •LS inputs (Light Switch) •Volt-free inputs •Self diagnosis for simplified fault finding •Adjustable delay On/delay Off timer Increased Performance The Sentinel Kinetic Plus benefits from the latest high efficiency, backward curved impeller design, ensuring the lowest possible energy consumption, ultra quiet operation and an exceptional performance range covering small one bed apartments to the largest of houses. Care Homes & Student Accommodation The Sentinel Kinetic Plus is ideal for larger homes and multiple occupancy units such as care homes and student accommodation. Capable of 400m 3 /hr at 150Pa, the unit can extract from up to ten bathrooms anda communal kitchen while still achieving almost 90% heat recovery. The fully automatic capability of the Kinetic range means that adequate ventilation is always achieved. The Kinetic’s BMS capability is also ideal for those commercial applications where landlords or property managers want to monitor and optimise building performance and maintenance. The Kinetic BMS can provide status information and its self diagnostics can report if any fault is found. Spigot Options Spigots may be re-positioned to give horizontal connection or a combination of vertical and horizontal connection. Optional 180mm/200mm spigots can simplify connection in commercial installations where larger diameter duct work has been used. Quick Change Filter As many systems are placed within cupboards the unique filter design folds as you remove it to ensure easy access in restricted spaces. Integral Humidity Sensor The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger thresholdis not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature.Models ModelStock Ref£Trade Kinetic Plus B Right4430281683.17 Kinetic Plus B Left443028L1683.17 AccessoriesModelStock Ref£Trade Wired Remote Controller44328357.30 Wireless Enable Kit44186585.95 Wireless Transmitter Controller43782753.16 Ventwise Controller441780193.38 LED Alarm with 15m cable44835630.93 Opto-coupler for volt-free bms connection44734037.12 Kinetic Spare Filters 2 pk.40370227.64 M5 Pollen Filter44420135.67 180mm/200mm Spigot Kit (One per pack)4465239.11 SAP PCDB Test ResultsThermal Efficiency % SFP (W/l/s) K+1 91 0.51 K+2 91 0.40 K+3 90 0.41 K+4 90 0.45 K+5 90 0.53 K+6 90 0.60 K+7 90 0.70

81 SEC Class Model SEC Class Kinetic Plus B A+ Dimensions (mm) A B C F D G EØ A B C D EØ F G 785 635 722 550 150 520 275 Weight: 24kg Performance Fan speeds are fully adjustable within the performance range. Volume(l/s)010 20 30 40 50 60 70 80 90 100 110 120 130 140 Volume (m 3 /hr)050100 150 200 250 300 350 400 450 500 700 600 500 400 300 200 100 0 Example system curves x Figure relates to Wattage (both motors) 21 42 83 140 173 147 86 33 19 S tatic Pressure (P a) 100% 80% 60% 40% 20% Sound Data Octave band, Hz, dB SWL SPL dB(A) Flow l/s Unit setting Test mode 63 125 250 500 1k 2k 4k 8k at 3m 50 20% Supply 46.5 54.3 46.4 44.8 36.2 28.5 24.5 31.2 28.5 Extract 46 52.2 42.3 38.7 27.6 24.2 24 31.7 25 Breakout 48.5 42.6 43.3 38.9 35.8 29.3 23.8 30.7 22.8 78 40% Supply 50.3 59.1 54.5 56.5 47 39.9 26.3 31.7 38 Extract 46.8 51.6 47.8 44.4 32.7 27.4 24.4 31.7 28 Breakout 48.4 51.2 53.4 46 41 34.6 25 30.3 28.5 104 60% Supply 52.4 57.2 60.4 60.9 55.8 50.3 33.1 33.9 43.6 Extract 50 49.8 56.8 52.4 40.2 35.9 33.4 39.8 35.2 Breakout 55 49.6 59.7 54.5 46.9 39.9 33.6 39.2 34.9 127 80% Supply 54.9 60.7 67.4 66.6 61.8 56 39.6 37.7 49.5 Extract 50.4 52 61.2 56.6 45.1 39.6 34.2 40.2 39.1 Breakout 53.5 53.4 60.8 59.1 53 45.3 36 40.1 38.7 137 100% Supply 54.7 61.7 70.5 69.9 62.7 57.5 42.1 38.3 52 Extract 54.4 55.1 65.8 57.5 46.9 40.6 33.7 40 41.8 Breakout 56.6 54.6 60.5 60.7 54.7 45.9 36.5 39.6 40 Tested according to BS848. Breakout quoted spherical. Supply and Extract quoted hemispherical.

82 Consultant's SpecificationOperationThe supply and extract ventilation unit shall be as Sentinel Kinetic Plus as manufactured by Vent-Axia and shall be sized as indicated on the drawings and shall be in accordance with the particular specification.Supply air to the room shall be pre-heated by the extract air via the integrated composite plastic counterflow heat recovery cell. The Sentinel Kinetic Plus shall automatically vary the ventilation rate via EC/DC motors, as it receives signals from one of the optional interconnected sensors. When a signal is received, the fans shall either vary their speed proportionally or on a trickle and boost principle. The unit shall have the facility to commission the supply and extract fans individually via in-built minimum and maximum speed adjustment, or alternative wired remote control unit. The fans themselves shall have independent, infinitely variable speed control. Unit SpecificationThe unit shall be manufactured with an ABS outer case construction, and incorporate a reversible core to allow for left or right hand mounting. The unit shall have a high efficiency composite plastic counterflow heat exchanger, supply and extract filters, automatic summer bypass, integral minimum and maximum infinitely variable speed controls with facia mounted failure indication. The unit shall have low energy, high efficiency EC/DC fan/motor assemblies with sealed for life bearings. The impellers shall be high efficiency backward curved centrifugal type. The unit shall have a heat exchanger cell with a thermal efficiency of up to 92% when tested to EN 308. This shall be protected by G3 grade synthetic filters on supply and extract. Complete with a condensate drip tray and drain connection. The unit shall be constructed with a removable Core allowing full maintenance access. The removable Core shall provide access to the following:Supply and extract filterHeat exchangerAccess to the electrical connections Access shall be provided for wiring termination and setup/commissioning. The backlit LCD user interface therein may be duplicated for remote mounting if required. Units shall be as manufactured by Vent-Axia Ltd. Standard ControlsAll Sentinel Kinetic units shall incorporate the following functions integrally mounted, pre-wired and factory fitted by the manufacturer: Integral infinitely variable fan speed controlon supply and extractIntegral min/max ventilation control/set pointIntegral BMS input/output interfaces – control and status indicationHeating interlocks 0-10V proportional speed adjustmentVolt free contacts 24V sensor supply Integral on/off or trickle boost function fromremote switch, e.g. PIRoccupancy detectorFully automatic summer bypassSwitched Live input with adjustable‘delay-on’ featureFan failure or component failure indicated via individual fault codedisplayRunning time counterControl panel PIN number lockAutomatic frost protection effective to -20°CThe unit shall incorporate an integral humiditysensor with thefollowing features:•Ambient Response; Raises the humidity trigger point as dwelling temperature reduces •Rapid Response: Monitors the rate of change in humidity and triggers increased airflow even if the humidity trigger threshold is not reached •Proportional Response; Incrementally increases the fan speed to reduce noise and reduce energy consumptionThe unit shall be controlled by the ‘Sentinel’ control devices (enablersand sensors) as detailed in the schedule or on the drawings.Tool free filter accessMounting Option Wall Surface

83 Airflow Direction Duct extract fromdwelling (Yellow) Acoustic duct (Optional)supply to dwelling (Red) Insulated duct from atmosphere (Green) Insulated duct exhaust to atmosphere (Brown) Front (RH) Duct extract from dwelling (Yellow) Acoustic duct (Optional) supply to dwelling (Red) Insulated duct fromatmosphere (Green) Insulated duct exhaust toatmosphere (Brown) Front (LH) Plan View Electrical Connection Please note: Electrical connection should be carried out by an appropriately qualified person and in accordance with current wiring regulations.Trickle to Boost by two lighting circuits or Trickle/Boost switch

84 Lo-Carbon Sentinel Kinetic High Flow •Recognised in SAP PCDB •180mm/200mm spigots •Horizontal duct option for space-saving installations •High airflow, ideal for student accommodation clusters •Unique folding filter for removal when access is restricted •Integrated digital controller for simple and accurate commissioning •Plug and play controls; Humidistat, Ventwise, Wireless Remote •BMS connectivity •LS inputs (Light Switch) •Volt-free inputs Increased Performance The Sentinel Kinetic Plus benefits from the latest high efficiency, backward curved impeller design, ensuring the lowest possible energy consumption, ultra quiet operation and an exceptional performance range covering small one bed apartments to the largest of houses. Care Homes & Student Accommodation The Sentinel Kinetic Plus is ideal for larger homes and multiple occupancy units such as care homes and student accommodation. Capable of 400m 3 /hr at 150Pa, the unit can extract from up to ten bathrooms anda communal kitchen while still achieving almost 90% heat recovery. The fully automatic capability of the Kinetic range means that adequate ventilation is always achieved. The Kinetic’s BMS capability is also ideal for those commercial applications where landlords or property managers want to monitor and optimise building performance and maintenance. The Kinetic BMS can provide status information and its self diagnostics can report if any fault is found. Spigot Options Spigots may be re-positioned to give horizontal connection or a combination of vertical and horizontal connection. Optional 180mm/200mm spigots can simplify connection in commercial installations where larger diameter duct work has been used. Quick Change Filter As many systems are placed within cupboards the unique filter design folds as you remove it to ensure easy access in restricted spaces. Integral Humidity Sensor The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even forthe smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature.Models ModelStock Ref£Trade Kinetic High Flow Right4084492317.50 Kinetic High Flow Left4084512317.50 AccessoriesModelStock Ref£Trade Wired Remote Controller44328357.30 Wireless Enable Kit44186585.95 Wireless Transmitter Controller43782753.16 Ventwise Controller441780193.38 LED Alarm with 15m cable44835630.93 Opto-coupler for volt-free bms connection44734037.12 Kinetic Spare Filters 2 pk.40370227.64 M5 Pollen Filter44420135.67 SAP PCDB Test Results Exhaust TerminalConfiguration Thermal Efficiency % SFP (W/l/s) K + 1 88% 0.65 K + 2 88% 0.54 K + 3 90% 0.52 K + 4 90% 0.55 K + 5 91% 0.6 K + 6 91% 0.66 K + 7 90% 0.74

85 SEC Class Model SEC Class Kinetic High Flow A Dimensions (mm) A B C F D G EØ A B C D EØ F G 785 635 722 550 180/200 520 275 Weight: 34kg Performance 0 100 200 300 400 500 600 700 800 900 1000 Static Pressure(Pa) Volume (l/s)0255075100125150175200 Volume (m 3 /hr)0100 200 300 400 500 600 700 100% 60% 40% 80% 20% Sound Data Octave band, Hz, dB SWL SPL dB(A) Test Mode Flow % 63 125 250 500 1.0K 2.0K 4.0K 8.0K@ 3m Supply20 55.1 65.9 55.2 53.8 44.4 37.4 25.3 24.9 37.4 Extract 58.2 57.4 48 45.6 43.8 34.5 20 24.5 31.1 Breakout 43.3 46.6 44.9 44.7 41.8 30.4 21.6 22.5 25 Supply40 63.1 69 67.1 64 55 51.6 39.7 32.4 46.8 Extract 58.6 58.4 60.1 53.7 41.9 41.5 31.7 25.1 37.5 Breakout 55.4 49.6 60.6 53.8 46.5 41.5 33.2 27.4 34 Supply60 70.3 74.3 81.4 71.5 63.6 59.9 49.6 43.1 57.4 Extract 64.4 64.2 72.6 59.1 48.7 45.7 37.8 29.3 47.6 Breakout 62.8 54.6 65.7 57.2 55.5 49.2 41.4 36.4 40.5 Supply80 75.3 77.9 88.1 78.7 68.4 65.1 56 50.1 64 Extract 71.1 68.2 73.6 61.8 51.9 49.5 42.7 37.6 49.1 Breakout 66.2 59 73.4 61.8 57 54.6 47.3 43.1 47.5 Supply100 90.9 80.9 84.4 80.1 71.5 68 59.3 54.5 63.3 Extract 92.4 71.8 78.1 67.4 54.9 51.5 44.6 41.4 55.1 Breakout 69.3 62.9 74.9 67.5 59.2 56.6 49.1 44.7 49.5 Tested according to BS EN 13141-7:2010. Breakout quoted spherical. Supply and Extract quoted hemispherical.

86 Lo-Carbon Sentinel Kinetic Cooker Hood •Recognised in SAP PCDB •Includes Cooker Hood Canopy •Horizontal duct option for space-saving installations •Fits within a 600mm wide aperture (300mm deep) •Integrated digital controller for simple and accurate commissioning •Plug and play controls; Humidistat, Ventwise, Wireless Remote •BMS connectivity •LS inputs (Light Switch) •Volt-free inputs •Self diagnosis for simplified fault finding •Adjustable delay On/delay Off timer Easy Installation Ducting can be attached to the unit horizontally, vertically or both. Minimum internal depth of kitchen cupboard: 300mm. Horizontal and Vertical Spigots: The combination of spigot options allows installation in confined locations. If vertical and horizontal connection are required on the same outlet/inlet, additional spigots can be supplied. The condensate connection can be taken through the rear of the unit or through the side of the unit into an adjacent cupboard prior to connection intopre-installed domestic waste water system. Cooker Hood Unit The Sentinel Kinetic Cooker Hood is designed to fit in a 600mm wide aperture above a hob. The telescopic hood incorporates two flat removable metal grease filters, low energy light bulbs and is available with a White or Brushed Aluminium front trim. The hood contains an integral fire damper in accordance with BRE Digest 398 and is connected to the heat recovery unit by a galvanised steel duct with access for cleaning. When the hood is opened, the heat recovery unit goes to boost speed and the summer bypass automatically opens to prevent cooking by-products entering the heat recovery cell. As an additional safety feature, the duct also contains a thermal cut-out fuse which turns off the MVHR unit in the event of excessive temperature in the airway. Cooker Hood units cannot be handed on-site and must be purchased as left hand (L) or right hand (R) models. ModelsLo-Carbon Sentinel Kinetic with summer bypass and humidity sensor.ModelStock Ref£Trade Kinetic CWH L (White Cooker Hood)4467561798.12 Kinetic CSH L (Brushed Aluminium Cooker Hood)4467571798.12 Kinetic CWH R (White Cooker Hood)4467581798.12 Kinetic CSH R (Brushed Aluminium Cooker Hood)4467591798.12 Integral Humidity Sensor The integral humidity (models with H suffix) sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature.Accessories ModelStock Ref£Trade Wired Remote Controller44328357.30 Wireless Enable Kit44186585.95 Wireless Transmitter Controller43782753.16 Ventwise Controller441780193.38 LED Alarm with 15m cable44835630.93 Opto-coupler for volt-free bms connection44734037.12 Kinetic Spare Filters 2 pk.44235623.56 M5 Pollen Filter44419923.56 SAP PCDB Test Results Thermal Efficiency % SFP (W/l/s) K+1 85 0.72 K+2 85 0.74 K+3 84 0.83 K+4 83 0.92 SEC Class Model SEC Class Kinetic CWH/CSH A

87 Dimensions (mm)A F B C D E L K Minimum clearance from the bottom of this unit to the top of the hob must be:Gas: 750mmElectric:650mm G JØ HA B C D E F G H JØ K L kg 590 710 295 316 598 90 140 360 125 550 550 27 Performance Fan speeds are fully adjustable within the performance range. 0 100 200 300 400 Static Pressure (Pa) 20% 40% 60% 80% 100% 0 100 200 300 400 S tat icP res sur e ( P a ) Volume Volume 010 20 30 40 50 60 70 80 010 20 30 40 50 60 70050100 150 200 250 050100150200 250300 53 27 20 30 44 128 107 20% 40% 60% 80% 100% m 3 /h l/s m 3 /h l/s 13 96 82 58 x figure relates to Wattage (both motors) x figure relates to Wattage (both motors) 12 49 26 18 25 38 118 97 89 75 54Example system curves -vertical spigotsExample system curves -horizontal spigots Sound DataOctave band, Hz, dB SWL SPL dB(A) Flow l/s Test mode 63 125 250 500 1K 2k 4K 8K@ 3m 10 Supply 47.8 40.2 38 31.1 28.2 22.1 23.6 30.9 21.4 Extract 47 38.7 36 29.9 25 22.4 23.3 30.8 20.6 Breakout 43.6 36.2 37.4 30.9 27.4 23.3 24.2 31.4 18.6 20 Supply 54 46.6 50.2 44.5 44.4 38.3 28.8 31.9 31.2 Extract 46.8 40.5 34.6 34.2 34.6 25.9 23.7 30.3 22.9 Breakout 45.9 39.9 40.6 35.7 33.5 28.4 25.3 31.2 21.3 30 Supply 58.1 54.5 57.6 52.2 51.7 47.6 38.6 35.8 38.5 Extract 47.6 46.2 38.7 41.3 42.8 33.9 26.4 30.5 28.4 Breakout 45.2 42.4 48.2 40.8 37.7 35.2 30 31.1 25.2 40 Supply 65.2 58.4 62.3 58 56.5 52.5 44.1 41.4 43.6 Extract 53.5 53 44 47.7 48.1 39.7 31.5 31.5 33.5 Breakout 50.9 47.6 47.4 48.1 42.5 40.8 36.3 34.4 29.3 50 Supply 66.4 63.2 66.3 62.5 61.7 57.4 50 47.8 48.3 Extract 64.2 55.2 48 50.9 52.1 44.5 35.9 35 37.2 Breakout 55 51 51.3 51.6 46.9 46.0 42 38.3 33.2 Tested according to BS848. Breakout quoted spherical. Supply and Extract quoted hemispherical.

88 Consultant's SpecificationOperationThe supply and extract ventilation unit shall be a Sentinel Kinetic as manufactured by Vent-Axia and shall be sized as indicated on the drawings and shall be in accordance with the particular specification.Supply air to the room shall be pre-heated by the extract air via the integrated composite plastic counterflow heat recovery cell. The Sentinel Kinetic shall automatically vary the ventilation rate via EC/DC motors, as it receives signals from one of the optional interconnected sensors. When a signal is received, the fans shall either vary their speed proportionally or on a trickle and boost principle. The unit shall have the facility to commission the supply and extract fans individually via in-built minimum and maximum speed adjustment, or alternative wired remote control unit. The fans themselves shall have independent, infinitely variable speed control. Unit SpecificationThe unit shall be manufactured with an ABS outer case construction, and incorporate a metal duct to the cooker hood, intumescent fire damper and thermal switch, in accordance with BRE Digest 398. The unit shall have a high efficiency composite plastic counterflow heat exchanger, supply and extract filters, automatic summer bypass, integral minimum and maximum infinitely variable speed controls with facia mounted failure indication. The unit shall have low energy, high efficiency EC/DC fan/motor assemblies with sealed for life bearings. The impellers shall be high efficiency forward curved centrifugal type. The unit shall have a heat exchanger cell with a thermal efficiency of up to 92% when tested to EN 308. This shall be protected by G3 grade synthetic filters on supply and extract. Complete with a condensate drip tray and drain connection. The unit shall be constructed with a removable Core allowing full maintenance access. The removable Core shall provide access to the following:Supply and extract filterHeat exchangerAccess to the electrical connections Access shall be provided for wiring termination and setup/commissioning. The backlit LCD user interface therein shall be removable for remote mounting if required. Units shall be as manufactured by Vent-Axia Ltd. Standard ControlsAll Sentinel Kinetic units shall incorporate the following functions integrally mounted, pre-wired and factory fitted by the manufacturer:Integral infinitely variable fan speed control onsupply and extractIntegral min/max ventilation control/set pointIntegral BMS interfaces – control and statusindicationHeating interlocks0-10V proportional speed adjustmentVolt free contacts24V sensor supplyIntegral on/off or trickle boost function fromremote switch e.g. PIRoccupancy detectorThe unit shall be controlled by the ‘Sentinel’ control devices (enablersand sensors) as detailed in the schedule or on the drawingsFully automatic summer bypassSwitched Live input with adjustable ‘Delay-On’ featureFan failure or component failure indicated via individual fault codedisplayRunning time counterControl panel PIN number lockAutomatic frost protection effective to -20°CTool free filter accessThe unit shall incorporate (‘H’ models) anintegralhumidity sensorwith the following features: •Ambient Response; Raises the humidity trigger point as dwelling temperature reduces •Rapid Response; Monitors the rate of change in humidity and triggers increased airflow even if the humidity trigger threshold is not reached •Proportional Response; Incrementally increases the fan speed to reduce noise and reduce energy consumptionIntegral Cooker Hood SpecificationThe Sentinel Kinetic Cooker Hood shall consist of a telescopic Hood and galvanised steel duct connection to the MVHR Unit. The Hood construction shall be of grey powder coated steel with Brushed Aluminium or White painted fascia. The Hood shall trigger the MVHR unit to a pre-defined boost speed and open the summer bypass when opened, and shall have two low-energy lamps illuminating the hob top. Filter shall be a flat metal grease filter, removable for cleaning. The galvanised steel ductwork shall provide a continuous fire barrier between the Hood and the MVHR unit. It shall contain an Intumescent fire damper, thermal cut-out and volume balancing damper. The thermal cut-out shall switch off the MVHR unit at a pre-defined safety temperature. The duct shall have an access panel for cleaning by the end-user.Mounting Option Wall

89 Airflow Direction Duct extract from dwelling (Yellow) Acoustic duct (Optional)supply to dwelling (Red) Insulated duct from atmosphere (Green) Insulated duct exhaust to atmosphere (Brown) Front (RH) Duct extract fromdwelling (Yellow) Acoustic duct (Optional) supply to dwelling (Red) Insulated duct fromatmosphere (Green) Insulated duct exhaust toatmosphere (Brown) Front (LH) Plan View Electrical Connection Please note: Electrical connection should be carried out by an appropriately qualified person and in accordance with current wiring regulations. Trickle to Boost by a Light Circuit

90 Lo-Carbon Sentinel Kinetic Horizontal •Manufactured in the UK •Building Regulations ADF compliant •Recognised in SAP PCDB •Energy Savings Trust best practice compliant •Up to 81% heat recovery whilst controlling condensation •Programmable Summer bypass •Digital controller for simple and accurate commissioning •External condensate connection •Plug and play controls; Humidistat, Ventwise, Wireless remote •LS inputs (Light Switch) •Volt-free inputs •Self diagnosis for simplified fault finding •Adjustable delay On/delay Off timer The Sentinel Kinetic Horizontal Range A wholehouse heat recovery system with up to 81% heat exchange efficiency. An easily accessible heat recovery cube protected by two removable G3 filters. Two Lo-Carbon Energy Saving EC/DC fans ensure long life (typically over double the life of AC motors) and lowest possible energy use. Fully insulated construction with built-in condensation drain. Specifically designed for new build constructions with a high level of insulation. Lo-Carbon Sentinel Kinetic Horizontal meets the latest requirements of the Building Regulations ADF for wholehouse system ventilation: System 4. Continuous mechanical supply and extract with heat recovery. Each model has three fully adjustable speeds and a purge setting (maximum flow). Supplied with the unit is a digital controller that can be used to pre-set the speeds to any required airflow within the performance range.Integral Humidity Sensor The integral humidity sensor (‘H’ models) increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Acoustically lined - low noise levels from only 20dB(A) @ 3m.ModelsModelStock Ref£Trade Kinetic 200ZPH407162 1156.38 Kinetic 200ZH4495401511.28 Kinetic 200ZMH448778 1511.28 Kinetic 300ZH4495361775.05 Optional Controls ModelStock Ref£Trade Wireless Enable Kit44186585.95 (includes one switch) Wireless Boost Switch43782753.16 (max 3 switches) Ventwise Controller441780193.38 (also requires sensors: see Accessories & Controllers section)Filter Spares ModelStock Ref£Trade Kinetic 200ZPH(G3) 2 pack4075840.00 Kinetic 200ZH/ZMH(G3) 2 pack44952419.16 Kinetic 200ZH/ZMH(M5) 1 pack4045740.00 Kinetic 300ZH (G3) 2 pack44957521.53 Kinetic 300ZH (M5) 1 pack4045750.00 Multiple Control Options: Five Volt-free pairs of switch terminals for sensor inputs allow boosting from a full range of Vent-Axia controllers – humidistats, PIR, timers. Two terminals with 0-24V outputs allow 0V to 10V proportional control by sophisticated controllers such as CO 2sensors and proportional humidistats. The optional Ventwise controller senses temperature rise in a bath/shower hot water supply and/or current in a cooker/hob electrical circuit to activate boost, ensuring additional ventilation when needed. Switch-live for boosting via light switches (220-240V AC) or manual Normal/Boost switches. This connection has the advantage of Delay-On and Delay-Off facility. Delay-On enables you to prevent the Boost airflow between 0 and 10 minutes after a light switch has been activated. Delay-Off allows the Boost airflow to continue after a light switch is turned off to ensure effective clearance of humidity. This timer is adjustable between 0 and 25 minutes. Summer BypassAn internal damper operates when the external temperature is below the internal temperature, and the internal temperature is too high. The bypass opens and allows the cooler outside air to help cool the dwelling.

91 Dimensions (mm) A B C SIDE FRONT BACK D E F G H K I J Model A B C D E F G H I J K Spigots Ø 200ZH 895 849 200 570 155 144 122 76 167 131 122 125 300ZH 985 940 301 720 184 179 187 102 279 174 187 150 Weight: 200ZH - 26kg, 300ZH - 38kgA B C K H SIDE D G I J E F FRONT BACK Model A B C D E F G H I J K Spigots 200ZPH 1000 950 200 575 155 142 60 61 142 154 143 204x60 200ZMH 895 849 200 570 195 140 54 66 168 138 143 204x60 Weight: 200ZPH - 14kg, 200ZMH - 26kg Galvanized steel outer case construction Normal mode: Fans run on Normal speed with bypass open until the internal dwelling temperature falls below the set 'Indoor' (maximum desired) temperature.Evening Purge mode: The fans run on Boost speed until the internal temperature falls below the set 'Indoor' temperature. If, after five hours the internal temperature is still above the set 'Indoor' temperature, the unit will switch down to normal speed for the remainder of the 'bypassopen' period. Night-time Purge mode: As Evening Purge, except that the unit will continue on Boost speed until the internal air temperature reaches the 'Outdoor' temperature set point (Default 14°C). This mode gives pre-cooling of the dwelling for thefollowing day. In Evening and Night Time Purge modes, the user can turn off the boost function by pressing theBoost button. Frost Protection In cold climates there is a possibility of frost building up on the intake side of the heat exchanger. In order to prevent damage, the Kinetic reduces supply flow while maintaining extract flow at temperatures down to -20°C. SEC Class Model SEC Class Kinetic 200ZH/ZPH/ZMH A Kinetic 300ZH A SAP PCDB Test Results 200ZPH Thermal Efficiency % SFP (W/l/s) K+1 86 0.62 K+2 84 0.65 K+3 83 0.76 200ZH/ZMH Thermal Efficiency % SFP (W/l/s) K+1 80 0.69 K+2 81 0.70 K+3 80 0.80 K+4 80 0.97 K+5 79 1.14 300ZH Thermal Efficiency % SFP (W/l/s) K+1 77 0.59 K+2 78 0.51 K+3 78 0.57 K+4 78 0.66 K+5 78 0.76 K+6 78 0.88 K+7 77 1.05

92 Performance - 200ZH/ZMH/ZPH Model Fan speeds are fully adjustable within the performance range. 600 500 400 300 200 100 0 S tatic Pressure (P a) 200ZH/ZMH 40% 20% Volume(l/s)010 20 30 40 50 60 70 80 Volume (m 3 /hr)0 50100150200250300100% 60% Sound Data - 200ZH/ZMH ModelFlow % Test mode 63 125 250 500 1k 2k 4k 8k dB(A) at 3m 20 Supply 50.3 54 50.1 45.5 37 36 27.5 31.1 30.0 Extract 47.2 47.7 46.6 41.8 30.7 27.9 24.6 30.5 26.3 Breakout 48.8 55.8 51.2 43.8 32.4 29.0 25.4 30.8 26.8 40 Supply 52.7 61.7 60.1 61.8 47.4 45.1 38.1 40.1 42.7 Extract 50.7 55.4 55.0 51.5 37.5 34.6 25.9 30.7 33.9 Breakout 53.7 60.1 61.1 50.7 40.2 35.8 27.1 30.3 34.0 60 Supply 52.8 64.5 66.7 59.4 51.1 51.1 42.9 39.3 44.0 Extract 50.6 59.0 62.1 57.1 43.7 40.0 29.0 31.6 39.7 Breakout 55.1 64.4 66.8 57.5 47.0 41.4 32.0 32.0 39.7 100 Supply 58.3 69.2 68.6 64.6 56.9 56.1 47.9 45.6 48.1 Extract 51.8 63.1 64.9 63.9 52.4 45.9 34.8 34.8 45.2 Breakout 59.4 68.1 69.7 68.3 53.1 47.1 36.5 34.3 46.5 Sound Data - 200ZPH Model Speed Test mode 63 125 250 500 1k 2k 4k 8k dB(A) at 3m 20% Breakout 48.3 41.3 37.7 35.8 34.5 28.2 26 31.2 21.5 Supply 39.6 37.1 36 32.9 30.6 22.9 24.9 29.4 23.1 Extract 49.4 40.7 35 30.4 26.3 22.5 23.6 30.1 20.8 40% Breakout 47.8 42.2 46.7 40.6 40.2 34.2 28.1 31.2 25.3 Supply 45.7 38.3 40.7 39 38.1 28.7 24.9 28.5 28.1 Extract 50 45.5 39.9 37 34.3 28.6 25.1 30.6 24.3 60% Breakout 54.4 51.2 53.8 46.2 43 38.9 33.8 32 29.7 Supply 46.1 49.2 45.3 44.4 42.4 35.2 27 29.3 32.7 Extract 49.5 41.9 45.4 41.7 39.4 35.2 27.6 30.3 27.7 80% Breakout 50.4 51.2 56.7 53.9 48.5 43.2 39.9 34.9 34.5 Supply 52.9 48.9 47.5 51.3 47.2 40.8 31.2 30 36.8 Extract 48.9 43.3 46.8 50 42.4 38.6 31.3 30.1 32.2 100% Breakout 49.3 49.8 52.9 54 51 46.3 41.2 35.7 35.1 Supply 43.8 45.8 50.7 56.3 50 44.3 35.7 29.7 38.2 Extract 53.2 46.9 48 52.8 45.4 42.1 35.1 30.5 34.9 0 50 100 150 200 250 300 350 400 450 550 500 0 5 10 15 20 25 30 35 40 45 Static Pressure(Pa) Volume (l/s) Volume (m 3 /hr) 0 50 100 150 100% 80% 60% 40% 20% 200ZPH Tested according to BS 848. Breakout quoted spherical. Supply and extract quoted hemispherical.

93 Sound Data - 300ZH Model 0 150 100 50 250 200 450 400 350 300 500 S tatic Pressure (P a) 010 20 30 40 50 60 70 80 90 100 050100 150 200 250 300 350 Volume (m 3 /hr) Volume (l/s) 300ZH 20% 40% 60% 100% Flow l/s Flow % Test mode 63 125 250 500 1k 2k 4k 8k dB(A) at 3m 26 10 Supply 42.5 42.8 38.3 32.9 28 24.6 25.5 30.3 26.3 Extract 46.9 45 40.3 34.4 27.4 23 24.3 30.1 22.5 Breakout 48.7 52.1 47.7 40.5 32.9 27.3 25.1 31.6 24.4 44 20 Supply 45.6 47 41.7 35.7 31.7 26.7 24.8 30 29.9 Extract 46.9 48.6 47 38.2 29.5 25.3 23.8 29.9 25.3 Breakout 50.2 56.4 53.9 46.3 37.5 32.5 25.2 31.4 28.8 55 30 Supply 44.4 46 52.9 39.4 35.1 31.9 25.5 30.5 33.9 Extract 47 48 55.5 42.5 32.2 29.9 25.7 30.6 30.6 Breakout 52.2 59.6 62 51.4 41.9 37.4 28.1 31.4 34.7 66 40 Supply 43.1 44.4 54.3 43.5 39.2 35.7 27.7 29.9 35.0 Extract 48.9 49 58.4 45.9 35.7 33.4 25.3 29.9 33.4 Breakout 54.6 58.3 66.1 52.6 39.3 36.5 31.1 35.3 37.7 85 60 Supply 44.7 49.8 58 50.4 45 41.9 30.6 30.3 39.1 Extract 51 53.6 61.2 50.1 41.6 40.1 30.7 31.1 36.7 Breakout 57.5 62.6 68.7 57.5 45.9 41 36.3 34 40.7 96 80 Supply 46 52.2 57.1 56.5 47.2 44.2 32.3 30.5 40.5 Extract 55.5 55 63.1 53.4 44.3 41 33.5 31.4 38.8 Breakout 62.2 65.7 68.8 63 50.8 43.8 38.8 35.4 42.9 98 100 Supply 46.6 52.3 57 55.4 47.1 43.7 32.1 30.3 40.1 Extract 53.7 55.2 63.3 53.3 44.1 41.2 33.2 31.5 38.9 Breakout 62.2 73.8 77.4 74.1 67.4 61 53.6 45.4 53.9 Tested according to BS848. Breakout quoted spherical. Supply and Extract quoted hemispherical. Performance - 300ZH Model Fan speeds are fully adjustable within the performance range.

94 Consultant's SpecificationOperationThe supply and extract ventilation unit shall be as Sentinel Kinetic Z as manufactured by Vent-Axia and shall be sized as indicated on the drawings and shall be in accordance with the particular specification; 200Z – 200mm deep, 300Z – 300mm deep. The Sentinel Kinetic Z shall automatically vary the ventilation rate via EC/DC motors, as it receives signals from one of the optional interconnected sensors. When a signal is received, the fans shall either vary their speed proportionally or on a trickle and boost principle. The unit shall have the facility to commission the supply and extract fans individually via the wired remote control unit. The fans themselves shall have independent, infinitely variable speed control. Unit Specification (200Z/ZM, 300ZH)The unit shall be manufactured with a galvanized steel outer case construction and shall have a high efficiency aluminium heat exchanger. Unit Specification (200ZP)The unit shall be manufactured with high density EPP case and shall have a high efficiency polymer heat exchanger. The unit shall have supply and extract filters, automatic summer bypass, integral minimum and maximum infinitely variable speed controls with failure indication via the wired remote controller. The unit shall have low energy, high efficiency EC/DC fan/motor assemblies with sealed for life bearings. The impellers shall be high efficiency backward curved centrifugal type. The unit shall have a heat exchanger cell with a thermal efficiency of up to 81% when tested to EN 308. This shall be protected by G3 grade synthetic filters on supply and extract. Complete with a condensate drip tray and drain connection. The unit shall be constructed with a removable access panel allowing full maintenance access from below. The removable panel shall provide access to the following:Supply or extract fanSupply and extract filterHeat exchangerAccess to the electrical connections Access shall be provided for wiring termination and setup/commissioning.Standard ControlsAll Sentinel Kinetic Z units shall incorporate the following functions integrally mounted, pre-wired and factory fitted by the manufacturer: Infinitely variable fan speed control onsupply and extractMin/max ventilation control/set pointHeating interlocks0-10V proportional speed adjustmentVolt free contacts24V sensor supplyOn/off or trickle boost function fromremote switch, e.g. PIRoccupancy detectorThe unit shall be controlled by the ‘Sentinel’control devices(enablers and sensors) as detailed in the schedule or on the drawingsFully automatic summer bypassSwitched Live input with adjustable ‘delay-on’ featureFan failure or component failure indicated via individual fault codedisplayRunning time counterControl panel PIN number lockAutomatic frost protection effective to -20°CThe unit shall incorporate (‘H’ models) an integral humidity sensorwith the following features: •Ambient Response: Raises the humidity trigger point as dwelling temperature reduces •Rapid Response: Monitors the rate of change in humidity and triggers increased airflow even if the humidity trigger threshold is not reached •Proportional Response: Incrementally increases the fan speed to reduce noise and reduce energy consumption The unit shall be controlled by the ‘Sentinel’ control devices (enablers and sensors) as detailed in the schedule or on the drawings. Mounting Option SlabAirflow Direction View from beneath (drawing for airflow demonstration only - not intended to be an accurate representation of the product) Extract fromDwelling (Yellow) FromAtmosphere (Green) Exhaust toAtmosphere (Brown) View from beneath Supply to Dwelling (Red)

95 Electrical Connection Please note: Electrical connection should be carried out by an appropriately qualified person and in accordance with current wiring regulations. NET J4 4321 Ventwise connector Switches 1-5 Proportional Inputs 1&2 LED 3A 2m mains cable fitted to unit Brown Switched fused spur Blue LNLS E 220-240V 50Hz Green/Yellow Black S/W1 + - + - + - +- +- +S - +S - +- S/W2 S/W3 SW4 S/W5 P1 0-10V P2 0-10V LED L NLS Wired Remote Controller Trickle to Boost by two lighting circuits or Trickle/Boost switch

96 Lo-Carbon Kinetic Plus E •Lightweight for easy installation •Easy access filters •External condensate connection •Compatible with a range of controls: PIR, Humidistat •Horizontal duct option for space-saving installations•Up to 94% heat recovery •Summer mode •Manufactured in the UK •Switched live inputs (Light switch control) A wholehouse heat recovery system with up to 94% energy efficiency. An easily accessible heat recovery cube protected by two removable GU3 filters. Two Lo-Carbon Energy Saving EC/DC fans ensure long life (typically over double the life of AC motors) and lowest possible energy use. Fully insulated construction with built-in condensation drain. Lo-Carbon Kinetic Plus E meets the latest requirements of the Building Regulations Approved Document F for wholehouse system ventilation. The Lo-Carbon Kinetic Plus E model has two adjustable speeds, normal and boost. On the front of the unit is the controller that can be used to preset the speeds to any required performance, up to 111l/s(400m 3 /hr) 150Pa. Offering ‘Close Control’ to prevent over ventilating.Acoustically lined - low noise levels from only 20dB(A) @ 3m. Left or Right Hand Installation Units are supplied right handed with duct spigots to outside on the right hand side. These can be reversed onsite by simply removing the control panel, rotating the unit 180 degrees and reattaching the control panel.Spigot Options The combination of spigot options allows installation in confined locations. If vertical and horizontal connections are required on the same outlet/inlet, additional spigots can be supplied. Filter Check An LED on the control panel illuminates at 6 month intervals to remind users to check and clean the filters.Frost Protection The Kinetic E range benefits from an automatic frost protection system to prevent the heat recovery cell freezing in very cold weather, while at the same time maintaining ventilation.Control Options There are two LS (Switched Live) inputs allowing the unit to be connected to a number of sensors and controllers such as Ventwise, Timespan, Ambient Response Humidistat. One of the LS connections also benefits from a ‘Delay-On’ feature which prevents the unit boosting unnecessarily.ModelModelStock Ref£Trade Kinetic Plus E4490591683.17 Accessories ModelStock Ref£Trade Kinetic Plus E Spare Filters 2 pack403702 27.64 Optional M5 Pollen Filter44420135.67 Isolator Relay Controller 44203064.46 180mm/200mm Spigot Kit (One per pack)4465239.11 SAP PCDB Test Results Exhaust TerminalThermal SFP Configuration Efficiency %(W/l/s) K + 1 94 0.41 K + 2 94 0.40 K + 3 94 0.43 K + 4 94 0.45 K + 5 93 0.52 K + 6 93 0.61 K + 7 93 0.73 SEC Class Model SEC Class Kinetic Plus E A+

97 Dimensions (mm) D G EØ A B C D EØ F G H 785 635 722 550 150 520 275 135 Weight: 24kg Performance Fan speeds are fully adjustable within the performance range. 0 100 200 300 400 500 600 0 050100 150 200 250 300 350 400 450 500 550 20 40 60 80 100 120 140 160 Static Pressure(Pa) Volume l/s m 3 /h 20% 40% 80% 100% 60% Sound Data Octave band, Hz, dB SWL SPL dB(A) Flow l/s Unit setting Test mode 63 125 250 500 1k 2k 4k 8k at 3m 50 20% Supply 46.5 54.3 46.4 44.8 36.2 28.5 24.5 31.2 28.5 Extract 46 52.2 42.3 38.7 27.6 24.2 24 31.7 25 Breakout 48.5 42.6 43.3 38.9 35.8 29.3 23.8 30.7 22.8 78 40% Supply 50.3 59.1 54.5 56.5 47 39.9 26.3 31.7 38 Extract 46.8 51.6 47.8 44.4 32.7 27.4 24.4 31.7 28 Breakout 48.4 51.2 53.4 46 41 34.6 25 30.3 28.5 104 60% Supply 52.4 57.2 60.4 60.9 55.8 50.3 33.1 33.9 43.6 Extract 50 49.8 56.8 52.4 40.2 35.9 33.4 39.8 35.2 Breakout 55 49.6 59.7 54.5 46.9 39.9 33.6 39.2 34.9 127 80% Supply 54.9 60.7 67.4 66.6 61.8 56 39.6 37.7 49.5 Extract 50.4 52 61.2 56.6 45.1 39.6 34.2 40.2 39.1 Breakout 53.5 53.4 60.8 59.1 53 45.3 36 40.1 38.7 137 100% Supply 54.7 61.7 70.5 69.9 62.7 57.5 42.1 38.3 52 Extract 54.4 55.1 65.8 57.5 46.9 40.6 33.7 40 41.8 Breakout 56.6 54.6 60.5 60.7 54.7 45.9 36.5 39.6 40 Tested according to BS848. Breakout quoted spherical. Supply and Extract quoted hemispherical.

98 Consultant's SpecificationOperationThe supply and extract ventilation unit shall be as Kinetic Plus E as manufactured by Vent-Axia and shall be sized as indicated on the drawings and shall be in accordance with the particular specification.Supply air to the room shall be pre-heated by the extract air via the integrated composite plastic counterflow heat recovery cell. The Kinetic Plus E shall automatically vary the ventilation rate via EC/DC motors, as it receives signals from one of the optional interconnected sensors. When a signal is received, the fans shall vary their speed on a trickle and boost principle. The unit shall have the facility to commission the supply and extract fans individually via in-built minimum and maximum speed adjustment. The fans themselves shall have independent, infinitely variable speed control. Unit SpecificationThe unit shall be manufactured with an ABS outer case construction, and incorporate a reversible core to allow for left or right hand mounting. The unit shall have a high efficiency composite plastic counterflow heat exchanger, supply and extract filters, integral minimum and maximum infinitely variable speed controls with facia mounted failure indication. The unit shall have low energy, high efficiency EC/DC fan/motor assemblies with sealed for life bearings. The impellers shall be high efficiency backward curved centrifugal type. The unit shall have a heat exchanger cell with a thermal efficiency of up to 94% when tested to EN 308. This shall be protected by G3 grade synthetic filters on supply and extract. Complete with a condensate drip tray and drain connection. The unit shall be constructed with a removable Core allowing full maintenance access. The removableCore shall provide access to the following:Supply and extract filterHeat exchangerAccess to the electrical connections Access shall be provided for wiring termination and setup/commissioning.Standard ControlsAll Kinetic Plus E units shall incorporate the following functions integrally mounted, pre-wired and factory fitted by the manufacturer: Integral infinitely variable fan speed control on supply and extractIntegral min/max ventilation control/set pointIntegral on/off or trickle boost function from remote switch, e.g. PIR occupancy detectorSwitched Live input with adjustable‘delay-on’ featureTool free filter accessFrost protectionLED 'filter check' indicator Mounting Option Wall Surface

99 Airflow Direction Duct extract fromdwelling (Yellow) Acoustic duct (Optional)supply to dwelling (Red) Insulated duct from atmosphere (Green) Insulated duct exhaust to atmosphere (Brown) Front (RH) Duct extract from dwelling (Yellow) Acoustic duct (Optional) supply to dwelling (Red) Insulated duct fromatmosphere (Green) Insulated duct exhaust toatmosphere (Brown) Front (LH) Plan View Electrical Connection The unit can be switched to boost by applying 230 V to the LS1 or LS2 inputs. Alternatively, the boost button on the control unit may be used. Mains Cable Connections Terminal No. Name Description L Mains Live 220-240 V AC, 50 Hz input N Mains Neutral 220-240 V AC, 50 Hz input EARTH Mains Earth Earthing connector LS1 Switched Live 1 220-240 V AC, 50 Hz input LS2 Switched Live 2 220-240 V AC, 50 Hz input CABLE FROM KINETIC ELS2LS1L NEMains Supply 220/240V 50Hz Supply 220/240V 50Hz Lighting Circuit Light Switch Light Switch N L EN L TYPICAL INSTALLATIONLamp 1 240V coil Relay NC Com No 240V coil Relay NC Com No Lamp 2

100 Integra •Powered heat recovery unit for smaller residential orcommercial applications up to 180m 2 •Up to 70% heat recovery •Low power consumption •Effective condensation control •Summer mode The Integra heat recovery unit has been specially designed to provide ventilation for flats or rooms in residential, commercial, educational or leisure applications. Balanced ventilation is achieved by using nominal 100mm diameter rigid ducting.Using a high performance, polymeric heat exchange cube, together with two powerful fans, the Vent-Axia Integra achieves efficiencies of up to 70%.The compact cube interleaves outgoing moist air with incoming fresh air, allowing the heat from one to warm the other without the two air streams mixing. Energy is saved on room heating, with no power being used by the cube itself. Performance of Integra: Up to 49l/s FID. Ideal for installation in ceilings voids or cupboards.The 150VA Transformer enables the selection of trickle settings to match dwelling volume. ModelsModelStock Ref£Trade Integra456864682.77 ControllerModelStock Ref£Trade Controller 150VA563538107.06 Airflow Direction Toatmosphere Fromatmosphere Extract fromdwelling Horizontal mounting Supply todwelling SEC Class Model SEC Class SEC Class (inc. LDC) Integra F C

101 Dimensions (mm) A BØ A C D E F G H A BØ C D E F G H 400 98 50 65 85 230 85 210 Weight: 6.5kg Performance Fan Static Pressure (Pa) 0 50 100 150 200 250 300 Volume l/s 0 10 20 30 40 50 1 2 3 4 5 6 Motor Speed/Curve Volume (l/s) (FID) Voltage (V) Wattage (W) 1 15 80 32 2 21 100 47 3 27 120 64 4 32 140 81 5 37 160 99 6 49 240 182 Integra to be used with a 150VA Transformer for maximum controllability.

102 NEW Integra Plus EC •Powered heat recovery unit for larger residential or commercialapplications •Up to 70% heat recovery •Low power consumption •Effective condensation control •2 speed control •Summer mode •EC motors Easy Installation The Vent-Axia Integra Plus EC is designed for mounting in ceiling voids, lofts and above a suspended ceiling. Four 150mm spigots are provided for simple connection to insulated flexible or rigid ventilation ducting. The unit comes complete with a 22mm condensate outlet. The Integra Plus EC incorporates two adjustable speeds and a Purge setting (full Speed). ModelModelStock Ref£Trade Integra Plus EC437666EC1055.32 SEC Class Model SEC Class SEC Class (inc. LDC) Integra Plus EC B A Airflow Direction From atmosphere Supply to dwelling Extract from dwelling To atmosphere Controllers & Sensors ModelStock Ref£Trade Ambient Response Humidistat 563550200.83Visionex PIR 459623115.70 TIM237034688.46

103 Dimensions (mm) I I CONTROL UNIT A BØ A C D E F G H A ØB C D E F G H I 580 150 100 64 125 350 125 305 85 Weight: 17kg fan box Performance 0 100 200 300 400 500 600 0 20 40 60 80 100 120 140 Static Pressure(Pa) Volume (l/s) 100% Sound DataFlow, l/s Unitsetting V Test mode Octave band, Hz, dB SWL SPL dB(A)at 3m 63 125 250 500 1k 2k 4k 8k 55 4 Supply 39.2 43.1 44.5 47.1 42.6 36.0 29.3 30.7 30.7 Extract 47.0 42.4 38.6 40.4 35.5 28.0 27.9 32.6 25.3 Breakout 43.2 42.7 38.2 37.6 33.4 28.4 27.6 31.5 21.7 69 5 Supply 42.0 47.6 46.1 49.9 48.8 41.2 33.7 32.5 34.4 Extract 47.8 42.2 41.4 43.2 40.4 29.6 27.7 32.5 27.7 Breakout 45.2 45.7 41.9 40.7 37.3 30.5 27.5 32.4 23.8 79 6 Supply 46.0 49.7 50.6 54.0 54.4 45.9 39.6 36.9 38.7 Extract 44.5 43.2 44.8 46.4 46.2 32.2 28.4 32.3 31.4 Breakout 46.2 47.2 44.3 43.4 43.1 32.8 28.5 32.2 26.6 81 6.6 Supply 47.0 52.5 53.8 56.4 58.3 48.8 42.8 40.8 41.8 Extract 50.3 45.3 47.7 48.5 47.4 35.0 30.7 32.9 33.0 Breakout 45.5 47.9 45.5 45.5 45.5 34.0 29.2 31.5 28.3 95 7 Supply 48.9 54.1 56.3 58.0 59.2 51.0 45.9 43.8 43.3 Extract 47.6 46.5 49.4 49.7 48.3 37.0 31.1 32.3 34.0 Breakout 49.0 49.5 48.2 47.5 47.3 36.7 31.1 32.3 30.1 109 8 Supply 51.0 58.2 57.4 60.1 61.2 54.4 48.9 48.0 45.6 Extract 56.2 52.4 51.7 53.1 49.6 39.5 33.8 33.2 36.3 Breakout 51.8 53.9 51.3 50.7 48.7 40.3 34.0 32.5 32.2 113 9 Supply 49.1 56.1 59.4 62.8 63.3 57.2 52.1 50.8 47.4 Extract 54.5 50.9 52.4 54.5 51.4 42.3 35.3 33.8 37.8 Breakout 53.6 54.3 52.8 52.3 50.8 43.4 36.2 33.5 34.1 Tested according to BS848. Breakout quoted spherical. Supply and Extract quoted hemispherical.

104 HR100R/RS •Controls condensation and odours - saves energy •Eliminates mould growth •Up to 70% heat recovery •Extremely quiet operation •Two speed settings The HR100R and HR100RS are ideal for single bedrooms/bathroom applications situated in hotel rooms, nursing homes and residential care homes.The HR100R features top access making it ideal for loft installations.The HR100RS features bottom access for installation on the slab above a suspended ceiling. The HR100R/RS is a self-contained heat recovery unit for mounting in lofts and suspended ceilings. The unit is supplied without controls to allow for the unit to be tailored to suit the individual requirements.Compatible with standard 100mm ducting for connection to internal grilles and external cowl.The unit comes fitted with a single 2-speed motor, and provides continuous low volume ventilation with a boost option. A variety of control devices are available for manual or automatic speed control.An integral heat exchanger transfers heat from the outgoing stale air to the fresh air supply, raising the supply air temperature whilst at the same time reducing its relative humidity.Up to 18l/s FID capacity. The unit provides superior control of condensation and odours, ideal for bathrooms or small internal rooms.Models HR100R Top access - ideal in loft installations.ModelStock Ref£Trade HR100R370377207.80 HR100RS Bottom access - ideal for suspended ceilings.ModelStock Ref£Trade HR100RS435004258.99 Controllers Normal Boost SwitchA single gang switch to boost from high to low speeds on all heat recovery systems.85x 85 x 10mm (H x W x D)ModelStock Ref£Trade Normal Boost Switch45521338.34 HR100RS Version

105 Dimensions (mm) A B C D E F G HØ 305 240 50 60 120 70 160 98 Performance 0 20 40 60 80 100 1200 2 4 6 8 10 12 14 16 18 Volume l/s Trickle Boost Pressure P a 1 1 2 2 Weight Extract Perf. l/s Watts dB(A) @ 3m Model kg Boost Trickle Boost Trickle Boost TrickleHR100R 5.6 18.3 13.6 29 19 30 20HR100RS 5.6 18.3 13.6 29 19 30 20 Mains electrical supply: 230V/50Hz

106 A ducted heat recovery unit for residential or commercial applications. The HR200V is self-contained and includes two mixed flow speed controllable fans. Using a high performance, polymeric heat exchange cube together with two power fans, the HR200V can boast a temperature efficiency of up to 70%. Low speed for trickle ventilation mode.Specially designed to provide ventilation for small internal rooms in commercial, educational and leisure applications. Ventilation is achieved by using nominal 150mm diameter ducting.Models ModelStock Ref£Trade HR200V14120010564.86 Accessory ModelStock Ref£Trade Transformer 150VA563538107.06SEC Class Model SEC Class SEC Class (inc. LDC) HR200V C B HR200V •Powered heat recovery module for smaller commercial applications •Up to 70% heat recovery •150mm duct connection •Extremely quiet on low speeds •Low power consumption •Washable heat exchanger •Pre-wired to a flexible cable

107 Dimensions (mm) Weight: 15.5kg fan box, 5kg controller C 275 4 - 148ØSpigots L 373 Fan End 95 183 95 30 435 30 From atmosphere Supply todwelling Extract fromdwelling To atmosphere Performance 240V Supply 160V Supply 140V Supply 240V Extract 160V Extract 140V Extract 0 20 40 60 80 100 120 140 0 20 40 60 80 100 120 Volume (l/s) Static Pressure (Pa) Motor Speed 1 2 3 Voltage 140 160 240 Watts51.5 60 110 Volume l/s (FID) Supply 48.3 55.8 70.3 Extract 241 286 371 HR200V to be used with a 150VA Transformer for maximum controllability.

108 HR500 •Efficient 550m 3 /h heat recovery ventilation unit or highperformance 900m 3 /h extract fan •Lightweight, compact and easy to install •Integral shutters on X type model •Easy to clean •Up to 70% heat recovery •Controller with sensor mode, allows a range of sensors to beused in conjunction with the HR500 and HR500X units •IPX5 rated Heat Recovery Ventilation HR500 heat recovery ventilation units for throughthe wall installation, which exhaust stale air whilst introducing warmed fresh air from the outside.Ideal for computer rooms, classrooms, offices and the health and leisure industries. The Vent-Axia HR500 unit is the perfect solution for commercial areas that require a high performance balanced intake/extract ventilation scheme. As a heat recovery ventilation unit it moves a useful 153l/s of air. The compact heat recovery cube interleaves outgoing warm air with incoming fresh air and allows the heat from one to warm the other without the two air streams mixing. Energy is saved on room heating with no power being used by the cube itself.The HR500 and HR500X consist of a tough telescopic wall sleeve into which the main body of the unit is housed. Walls of up to 670mm thick can be easily accommodated. Behind the neat deflecting fascia grilles are the filters, the heat exchange cube and fan units. All wall sleeve components, the heat exchange cube and the fascia grilles are made of tough polymeric materials. Electrical Maximum ambient temperature +40˚C.Supply Voltage 220-240V/1/50Hz. Models HR500 Commercial Wall-mounted intake/extract ventilation unit with built-in heat recovery facility. For commercial and leisure areas. Lightweight, compact and easy to install.ModelStock Ref£Trade HR500141010101030.84 HR500XAs HR500 with shutters.ModelStock Ref£Trade HR500X14101070 1280.79 Controller HR500 Controller Surface mounting. On/Off remote sensor mode. Heat exchange, single fan extract or twin fan extract modes. Infinitely variable speed. Minimum speed setting. Suitable for controlling up to 2x HR500. 86 x 156 x 53 (W x H x D).ModelStock Ref£Trade HR500 ControllerW14301010 157.12

109 Dimensions (mm) PerformanceAirflow performance (l/s) Sound Heat recovery Extract mode Watts dB(A) @ 3m Modelmode (max) (max) (max) HR500 153l/s 250l/s 200 53 HR500X 153l/s 250l/s 220 53

110 The HR500D is a self-contained unit with integral extract and supply fans to provide balanced ventilation and heat recovery via supply diffusers and extraction grilles. The unit is fully speed controllable. The compact heat recovery cube interleaves outgoing warm air with incoming fresh air and allows the heat from one to warm the other without the two air streams mixing.Energy is saved on room heating with no power being used by the cube itself. Performance of HR500D: Supply and extract up to 174l/s FID capacity on heat recovery mode. Ideal for offices, computer rooms, pubs and clubs, etc. Model Surface mounting. On/Off remote sensor mode. Heat exchange, single fan extract or twin fan extract modes. Infinitely variable speed. Minimum speed setting. Suitable for controlling up to 2x HR500. ModelStock Ref£Trade HR500D370450942.88 Controller ModelStock Ref£Trade Speed ControllerW14301010157.12 HR500D •Self-contained unit with integral fans •Up to 70% heat recovery •External wall mounting

111 Dimensions (mm)Hole opening: 610 x 381mm From atmosphere Supply todwelling Extract fromdwelling To atmosphere A B C A B C 480-750 600 340 Performance Guide % Thermal Efficiency Volume (m 3 /h) 100 80 60 40 20 0 0100 200 300 400 500 600 Heat Exchanger Efficiency Airflow performance l/s (max) Watts (max) dB(A) @ 3m (max) Weight kg 174 l/s 210 53 19

112 The unit is a semi-remote heat exchange unit with 70% heat recovery, designed for mounting in internal walls (HR500IP) and external walls (HR500EP) for installations using ducted extraction and fresh air supply. The HR500 units provides air movement via two independent in-line duct fans to suit length and configuration of ducting systems. The unit is ideal for use with in-line centrifugal type fans and compatible accessories.Performance of HR500EP and HR500IP: Up to 244 l/s FID capacity (balanced airflow). Ideal for computer rooms, classrooms, offices and the health & leisure industries. ModelModelStock Ref£Trade HR500IP370447605.28 HR500EP370451562.75 EP Unit Hole opening: 610 x 381mm From atmosphere Supply todwelling Extract fromdwelling To atmosphere A IP UnitFrom atmosphere To atmosphere Supply todwelling Extract fromdwellingHR500EP/IP•Passive - no fans •Lightweight - easy installation •Up to 70% heat recovery •Internal wall mounting HR500IP •External wall mounting HR500EP

113 Dimensions (mm)EP & IP UnitHole opening: 610 x 381mm A B C A B C 480-750 600 340 Weight: 9kg Performance Pressure Drop over Heat Exchange Unit Volume (m 3 /h) Pressure Drop (P a) 0200 400 600 800 1000 300 200 100 0 Thermal Efficiency Graph Ef ficiency % Volume (m 3 /h) 0200 400 600 800 1000 70 60 50 40 30 20 10 0

114 A ‘stand alone’ heat exchange module which will transfer up to 70% of the outgoing heat to incoming air. Polymeric construction with spigots to suit 200, 250 and 315mm Ø flexible ductwork.Module accessible for routine cleaning. Condensate outlet provided. Ideal for use in air conditioned environments.The heat exchanger works at the same high efficiency, automatically keeping a cool room cool. Performance of the Heat Exchange Unit: At 180l/s achieves 70% temperature efficiency (balanced airflow). Ideal for schools, pubs, offices and leisure industries. ModelModelStock Ref£Trade HR500DP10538290617.98 HR500DP •Passive - no fans •Lightweight, compact and easy to install •Up to 70% heat recovery •Easy to clean

115 Dimensions (mm)A B C A B C 700 600 340 Weight: 9kg Performance % Thermal Efficiency Preasure Drop (Pa) 100 50 0 300 200 100 0 Volume (m 3 /h) Volume (m 3 /h) 0500 1000 1500 05001000 1500 Heat Exchange Resistance Graph Thermal Efficiency Graph

Ducting & Fittings Since 1936, Vent-Axia has been known for providing a complete ventilation solution. This has not changed, and now we offer one of the widest ranges of ancillaries available today.

NEW Vent-Axia Pure Air 118-119Arterial Duct System 120-121 Uniflexplus+ Semi-Rigid Duct System 122-123 NEW Wholehouse Attenuators 124 Universal Roof Vents 125 Internal Fit Wall Kit 126 Low Resistance Inlet/Outlet Air Brick 127 Ducting & Accessories 128-135 Galvanised Spiral Wound Ducting 136 Fire Stopping – Round and Flat Ducting 137 100mm & 150mm Accessories 138-141

118 NEW Vent-Axia Pure Air •Removes NOX and other gases •Removes particles down to PM2.5•Offers multiple spigot options •Low pressure drop •Easy to install with mounting brackets •Conforms to international air quality guideline limits •Easy installation & maintenance•Various sizes to suit residential or commercial applications •Provides induct noise attenuation•Insulating jackets available What is it? The Vent-Axia Pure Air combines particulate and gas filters to remove pollutants prior to entering residences and commercial buildings through mechanical ventilation and heat recovery systems. The Vent-Axia Pure Air is designed to bring outdoor air pollutant levels within the guideline exposure limits as set out in the World Health Organisation Air Quality Guidelines and the CAFE Directive prior to entering an occupied space. Indoor air quality (IAQ) is becoming increasingly important with properties being built in urban, industrialised areas. The Vent-Axia Pure Air offers a complete filtration solution with a range of specifiable products that meet planning obligations and refine traditional filtration, leaving home owners withconfidence in their heat recovery systems.What does it do? The Vent-Axia Pure Air sets the benchmark for high level filtration. It targets pollutants generated outside of the home, by traffic and industrial processes, and reduces these before supplying the air into the dwelling.The Vent-Axia Pure Air filter is fitted to the intake airflow and incorporates two types of filtration: •Enhanced activated Carbon which removes unpleasant odours and harmful gasses such as Nitrous Oxide (NO 2 ). •G4 or F7 particulate filters which can remove tiny airborne contaminants such as pollen, bacteria and even PM2.5 diesel particulates. The combination of MVHR and Vent-Axia Pure Air filtration offers the ideal indoor environment. Unit Specification The Vent-Axia Pure Air is manufactured from 1.2mm Galvanised Steel together with suitable sealing for particulate and gas filters. Access is available on both sides via bolted lift off panels. Various round and rectangular transformation spigots are available to suit ductwork systems for both domestic and commercial duct work.Filter Specification Particulates, PM10, PM2.5The Vent-Axia Pure Air can house up to two particulate filters. Panel filters of Grade G4 to EN779 having an arrestance above 90%, making it suitable for the removal of PM10 Particulates. An additional particulate filter of grade F7 to EN779 can be included to further reduce smaller particles (PM2.5) to an efficiency between 70% and 80% at 0.4 μ m. Pollutant Gases, NO 2 , SO 2 , O 3 , VOC The gas stage filters in the Vent-Axia Pure Air are designed to achieve a minimum contact time suitable for the removal of pollutant gases at the rated airflow. A specially formulated activated carbon and chemical mix acts upon pollutant concentrations common in dirty city air, reducing them below guidelines set by current legislation. Unit Configuration Replaceable PM2.5 or 10 Filters Replaceable Gas Filters Configurable Supply Spigot Configurable Extract Spigot Accessories ModelStock Ref£Trade 50 l/s insulating jacketPAJAC-500.00 100 l/s insulating jacketPAJAC-1000.00 Spare PM2.5 filterPAFIL-250.00 Spare PM10 filterPAFIL-100.00 Spare gas filterPAFIL-NO20.00

119 Models Stock Ref Airflow l/s Intake Spigot (mm) Exhaust Spigot (mm) Filter Types Clean Filter PressureDrop (Pa) Approximate UnitWeight (kg) PA50-125125-25 50 125Ø 125Ø PM2.5 100 25 PA50-125204-25 50 125Ø 204 x 60 PM2.5 100 25 PA50-204204-25 50 204x60 204x60 PM2.5 100 25 PA50-125125-10 50 125Ø 125Ø PM10 45 25 PA50-125204-10 50 125Ø 204x60 PM10 45 25 PA50-204204-10 50 204x60 204x60 PM10 45 25 PA100-150150-25 100 150Ø 150Ø PM2.5 100 49 PA100-150220-25 100 150Ø 220x90 PM2.5 100 49 PA100-220220-25 100 220x90 220x90 PM2.5 100 49 PA100-150150-10 100 150Ø 150Ø PM10 45 49 PA100-150220-10 100 150Ø 220x90 PM10 45 49 PA100-220220-10 100 220x90 220x90 PM10 45 49 PA200-200200-10 200 200Ø 200Ø PM10 45 96 PA200-250250-10 200 250Ø 250Ø PM10 45 96 PA300-315315-10 300 315Ø 315Ø PM10 45 144 Airflow may be reversed through the unit to offer alternative spigot options. Example Stock Ref:PA50 - 125 125 - 25Pure AirLitres Per SecondIntake Spigot Dia.Exhaust Spigot Dia.PM Filter Grade Dimensions (mm) A J B C E I H G F 12mmØ D Access Space Filters can be accessed from either side of the unit. Top Side Front Airflow l/s A B C D E F G H I J 50 310 980 50 700 25 435 405 10 220 340 100 620 980 50 700 25 730 700 10 220 650 200 620 980 50 700 110/85 730 700 10 420 650 300 620 980 50 700 160 730 700 10 630 960 Spigot Configuration 125Ø to 204x60150Ø to 220x90 25mm 25mm 25mm 204x60 to 204x60220x90 to 220x90 25mm 25mm 125Ø to 125Ø150Ø to 150Ø 200Ø to 200Ø250Ø to 250Ø 315Ø to 315Ø 25mm

120 Arterial Duct System •Reduces installation time •Can be applied in SAP as a rigid duct system •Crush resistant semi-rigid duct •Unique low-resistance manifolds •Simple installation through joists •Smooth inner surface with antistatic and antibacterial coating •Combines the advantages of rigid ducting with the versatility ofa semi-rigid system Arterial System For use with MVHR systems, the Arterial air distribution system provides a flexible, highly robust solution, which can significantly reduce the installation time when compared to a standard system. Rigid vs Semi-Rigid Systems Both traditional duct types have limitations in modern construction. Rigid systems: Passing rigid duct through a floor cassette at right-angles to the joists is time consuming and multiple connections increase the risk of leaking ductwork.Semi-rigid Systems: It can often be difficult to accommodate two distribution boxes and multiple semi-rigid pipe runs in new buildings and the time saving advantages are soon overtaken by the additional cost of materials. Reduced Installation TimeThe Vent-Axia Arterial range combines the advantages of semi-rigid and traditional rigid ducting in one simple system. The system is independently tested and can be applied in SAP as a standard rigid system. Drops between floors to/from the MVHR unit remain in rigid PVC, having the advantage of low space usage and low cost. Traversing through joists in a floor cassette is much simpler and faster when using semi-rigid duct. The secret to the Arterial System is the unique low-resistance distribution plenum (Patent Pending) which is sited between joists allowing connection between semi-rigid and rigid sections. Single Spigot Adaptor A B C External Dimensions (mm) Stock Ref Duct Size A B C £Trade 408872 220x90 to 78Ø 94 258 150 12.36 Double Connector Plate A B C A External Dimensions (mm) Stock Ref Duct Size A B C £Trade 408873 220x90 to 78Ø 98 226 66 8.24 Single Connector Plate A B C g A External Dimensions (mm) Stock Ref Duct Size A B C £Trade 408874 220x90 to 78Ø 98 226 66 8.24 Blank Plate A B C External Dimensions (mm) Stock Ref Duct Size A B C £Trade 408875 220x90 to 78Ø 98 226 26 8.24 Reducer A B C External Dimensions (mm) Stock Ref Duct Size A B C £Trade 408885 120 to 78Ø 129 105 129 3.61 Semi-Rigid Ducting Stock Ref O/I Ømm Length m Coil Ømm Coil Heightmm kg £Trade 40658775/64 50 1100 350 24.3 200.89 406588 90/78 50 1130 250 19.5 245.54

121 Complete System Setup Example Model220x90 to 78mmØ Single Spigot Adapter Stock Ref 427360 Model220x90 to 90mmØ (78mm ID) Single Spigot Adapter Stock Ref 427360 Joists Model125mmØ 90° Bend MMStock Ref 427360 ModelRound 125mmØ to 204x60 Adapter FFStock Ref 370127 MVHR Unit Model120 to 78mmØ ReducerStock Ref 408885 Model125mmØ Circular Supply DiffuserStock Ref 10543125 Model125mmØ Round Ducting Stock Ref 434715Model90mmØ (78mm ID) eDuct Circular PipeStock Ref 406588 Model90mmØ (78mm ID) eDuct Circular PipeStock Ref 406588 Model125mmØ Circular Exhaust DiffuserStock Ref 10544125 Model125mmØ Round Ducting InsulatedStock Ref 406874 Model 220x90 Flat ChannelStock Ref 403025 Model 220x90 Double Connector PlateStock Ref 408873 Model 220x90 to 150mmØ Elbow Bend FMStock Ref 449362 Model 220x90 to 150mmØ Elbow Bend FMStock Ref 449362 Model 220x90 to 150mmØ Elbow Bend FMStock Ref 449362 Model Equal Tee MMMStock Ref 428636 System Configuration Examples 90mm Semi Rigid Duct Double Connector Plate Single Spigot Adapter Single Spigot Adapter Single Connector Plate Single Spigot Adapter 220x90 Blanking Plate 220x90 Duct Connector Single Spigot Adapter Single Spigot Adapter Single Spigot Adapter Double Connector Plate

122 Uniflexplus+ Semi-Rigid Duct System •Compact, low profile system•Highly flexible and robust •Extremely crush resistant•Quick and easy to install•PCDB listed •Suitable for installation in concrete •Corrosion resistant •Smooth inner surface with antistatic and antibacterial coating •Independently tested and accredited for air tightness•Class D air tightness •Operating temp.: -20°C to +60°C • Aspigot blanking cap is provided for use with single runs of semi-rigid. Uniflexplus+ Semi-Rigid Range The Uniflexplus+ Semi-Rigid Range sets the standard for easy to install, low profile ducting solutions. The system gives all of the flexibilitythat semi-rigid ducting provides - without taking up vital space. With minimal components, the system is uncomplicated to ensure a hassle-free, speedy install.The Uniflexplus+ Semi-Rigid Range is compatible with most wholehouse ventilation systems including the Lo-Carbon Sentinel Kinetic Range (MVHR). Accessories Circular Extract DiffusersDuct SizeStock Ref£Trade 125 Ø1054412522.18 Circular Supply DiffusersDuct SizeStock Ref£Trade 125 Ø1054312521.34 Duct KnifeDuct SizeStock Ref£Trade 90 Ø47225245.98 75 Ø47225845.98 90° BendDuct SizeStock Ref£Trade90 Ø47225323.38 75 Ø47225920.46 CouplerDuct SizeStock Ref£Trade 90 Ø4722548.18 75 Ø4722607.31 Complete System Setup Examples The distribution boxes can be mounted vertically on a wall or fixed horizontallyonto a ceiling slab to achieve a solution tailored to your need. At a depth of just 90mm, the distribution boxes offer a considerably low-profile solution - they can then be combined with various components to suit on-site needs.Semi-Rigid ducting is run from distribution boxes and ancillaries to respective rooms in the dwelling. Connecting the Semi-Rigid ducting to components is exceptionally straightforward to allow speedy installation - simply turn the ducting into the spigot until it clicks twice to achieve an airtight mechanical seal.Rigid or flexible 125mm diameter ductingis then run from the MVHR unit to the distribution box. 90 oValve Collector Straight ValveCollector 8 Way Distribution Box Rigid/Flexible 125mm Ducting 12 Way Distribution Box Straight ValveCollector 90 °Valve Collector

123 Models A A B 90° Valve CollectorThe 90° Valve Collector connects a section of 125mm diameter ducting and turns 90° into 2 spigots to connect to the semi rigid - ideal for dropping semi-rigid into ceiling diffusers. Duct SizeStock Ref£Trade 2xØ75 - Ø125mm47225539.54 2xØ90 - Ø125mm47224844.14 Dimensions (mm) Stock Ref Curve Ref A B kg 472255 1 356 294 0.8 472248 2 376 300 0.9 Performance 0 2 4 6 8 0 51015 20 25 30 Pressure Loss Pa Volume l/s 2 1 A B C Distribution BoxThe low-profile distribution box runs a central spigot of diameter 125mm into a set of either 8 or 12 sub-spigots, depending on requirements. Available with either 75mm or 90mm semi-rigid spigots. ModelStock Ref£Trade 12xØ75 -Ø125mm472256160.94 8xØ75 -Ø125mm472257137.95 12xØ90 -Ø125mm472250188.53 8xØ90 -Ø125mm472251156.34Dimensions (mm) Stock Ref Curve Ref A B C kg 472256 1 123 742 504 3.6 472257 2 125 467 467 2.2 472250 3 124 755 520 3.9 472251 4 125 479 479 2.3 Performance 020 40 60 80 100 120140 Volume l/s 60 50 40 30 20 10 0 3 2 4 1 PressureLoss P a A B C Straight Valve CollectorThe straight valve collector takes 125mm ducting and turns it straight into 2 spigots to connect to semi-rigid. ModelStock Ref£Trade 2xØ75mm - Ø125mm47226134.482xØ90mm - Ø125mm472262 38.58 Dimensions (mm) Stock Ref A B C 472261 125 305 229 472262 123 311 229 Semi-Rigid DuctingSuitable for installation in concrete ceilings, suspended ceilings, internal walls, risers or frames, the Semi-Rigid Ducting is double-walled providing optimum flexibility. With an antistatic and antibacterial coating, the internal surface of the Semi-Rigid Ducting is smooth to ensure minimal resistance to airflow. Normally flammable construction material class E, according to EN-13501-1. Pipe SizeStock Ref£Trade 75mmØ x 50m406587200.89 90mmØ x 50m406588245.54 75mmØ x 25m474077100.45 90mmØ x 25m474078122.77 Dimensions (mm) Stock Ref Curve Ref O/I Ømm Length m CoilØmm Coil Heightmm kg 406587 175/64 50 1100 350 24.3 406588 2 90/78 50 1130 250 19.5 474077 -75/64 25 1100 175 12.2 474078 - 90/78 25 1130 125 9.8 Performance 0 0 51015 20 2 4 6 Volume l/s 1 2 Pressure Loss per metre Pa/m

124 NEW Wholehouse Attenuators •Reduces induct noise •Variety of sizes to suit specified noise requirements •Compatible with both 204x60mm 2and 220x90mm 2 rectangular ductwork•Central and offset spigot options to suit each installation•Rigid galvanized steel construction•Easy installation•Suitable for almost any ventilation system •Low pressure loss The Vent-Axia Wholehouse Attenuator has been developed to reduce induct noise in both residential and commercial ducting systems.Technical Details The Wholehouse Attenuator is compatible with either 204x60mm 2or220x90mm 2ducting, it also offers two spigot options to suit the installationand design requirements. The Wholehouse Attenuator is available with either a standard centralised spigot or, for instances when the ducting is installed flat to a concrete slab, an offset spigot. As well as saving the need for additional ducting components, this allows for a much easier and quicker installation.Noise Reduction Offering excellent sound reduction over a range of frequencies, the Wholehouse Attenuator is available in two lengths depending on the noise suppression requirements. For MVHR systems the attenuator can be fitted on the supply side to habitable rooms, reducing airborne in-duct noise. For MVHR and extract-only systems, the attenuator may be placed on the extract side to limit ‘cross-talk’ through ductwork between rooms. Models Central SpigotModelStock Ref£Trade 204x60 Duct 920mm Length407915127.31 204x60 Duct 1220mm Length407916169.74 220x90 Duct 920mm Length407920127.31 220x90 Duct 1220mm Length407921180.35 Offset SpigotModelStock Ref£Trade 204x60 Duct 920mm Length4754270.00 204x60 Duct 1220 Length4754280.00 220x90 Duct 920mm Length4754290.00 220x90 Duct 1220mm Length4754300.00 Dimensions (mm) C D D A Front (Central) Side B A Front (Offset) B Stock Ref A B C D kg 407915 200 120 920 50 13 407916 200 120 1220 50 17 407920 210 145 920 50 14 407921 210 145 1220 50 17 475427 207 120 920 50 13 475428 207 120 1220 50 17 475429 223 145 920 50 14 475430 223 145 1220 50 17 Acoustic Performance Insertion Loss (dB) Stock Ref 63 125 250 500 1k 2k 4k 8k 407915 4 5 10 19 30 47 49 36 407916 4 7 13 26 39 55 53 38 407920 4 7 14 24 39 51 48 38 407921 5 8 18 32 50 55 52 41 475427 4 5 10 19 30 47 49 36 475428 4 7 13 26 39 55 53 38 475429 4 7 14 24 39 51 48 38 475430 5 8 18 32 50 55 52 41 Pressure LossDuct Size (mm) Length (mm) Volume (l/s) Pressure Loss (Pa) 204x60 1220 15 6 204x60 1220 30 10 204x60 1220 60 25 204x60 1220 80 41 220x90 1220 15 6 220x90 1220 30 10 220x90 1220 60 22 220x90 1220 80 36

125 Universal Roof Vents •Models available for both pitched and flat roof types •Complies with Building Regulations•Suitable for most installations •Corrosion and weather proof•Compatible with both mechanical and natural ventilation systems •Three colours available for pitched roof vents Wholehouse ventilation systems require termination to the external atmosphere, often through the roof. To ensure that the ventilation system is able to achieve it’s optimum level of performance, it is important that a suitable roof termination product is installed.With this in mind, Vent-Axia is pleased to offer a range of Universal Roof Vents; including products suitable for both pitched and flat roof types.A selection of colours and sizes should ensure that our range offers a product suitable for most residential applications with a pitched or flat roof.Models Universal Roof Vent suitable for Pitched RoofsManufactured in the UK, these products have been specifically developed for use with both natural and mechanical ventilation systems.All models have been independently tested by the BRE to BS476 Part 3: 2004 and have been awarded an AA classification - the highest possible. Thus they can be installed without restriction on any pitched roof. All models have low resistances to airflow (see table) and incorporate condensation grooves to prevent any condensate running back down the duct. Universal Roof Vents are designed to resist the ingress of deluge and driving rain. Universal Roof Vents (pitched roof models) are suitable for roof pitches between 20° and 60°.The pitched roof vents are available as a ‘tiled’ roof vent to fit alongside most traditional roof tiles, as well as a ‘slate’ version which can be easily cut down to fit alongside all traditional roof slates. Pitched roof vents are available in a variety of colours as detailed in the Specification Table - custom colour and textured vents to match your exact needs are also available at an extra charge. Stock Tile Spigot Airflow Resistance (Pa) at l/s Ref Type mm Colour 14 28 56 83 140 £Trade 407329 Tile 125 Red 1.1 4.1 16.8 N/A N/A 89.12 407330 Tile 125 Brown 1.1 4.1 16.8 N/A N/A 89.12 407331 Tile 125 Grey 1.1 4.1 16.8 N/A N/A 89.12 407332Tile 150 Red 0.3 1.0 4.2 9.5 27.4 105.03 407333 Tile 150 Brown 0.3 1.0 4.2 9.5 27.4 105.03 407334 Tile 150 Grey 0.3 1.0 4.2 9.5 27.4 105.03 407335 Slate 125 Slate Blue/ Black 1.1 4.1 16.8 N/A N/A 82.75 407336 Slate 150 Slate Blue/ Black 0.3 1.0 4.2 9.5 27.4 98.66 Universal Roof Vent suitable for Flat RoofsCapped stacks for use in asphalt and built-up felt roofs. Special low air resistance cowl - the pressure/airflow resistance is 1.0 Pascal at 63 l/s. The pipework above the roofline is twin walled and incorporates an integral condensation drain. The stack pipe has an integral collar and separate aluminium flange for use with both felt and asphalt roof finishes. All Vent-Axia Universal Roof Vents have a free area exceeding those required by building regulations. Stock Ref Colour Free VentArea mm 2 Pressure/ AirflowResistance Dia.mm Height AboveRoofmm FlangeDia.mm DepthBelowFlangemm £Trade 407337 Black 8,400 1.0 110 300 395 350 125.72 407338 Black 12,000 1.0 131 400 450 350 125.72 407339 Black 20,000 1.0 166 540 450 510 178.77

126 NEW Internal Fit Wall Kit •Ideal for high-rise applications •Suitable for 100mm fans •Quick & easy installation •Extendable length•Fits entirely from inside the property •Reduces water ingress •Includes low-resistance external grille •Suitable as a passive air grille •Covers external break-out Internal Fit Wall Kit The NEW Internal Fit Wall Kit is designed to simplify installation and improve the finish of 100mm through the wall installations, also providing an external grille and water ingress protection shroud. High Rise Buildings The Wall Kit is fully installed from inside the building, avoiding the need for scaffolding and significantly reducing the cost and complexity associated with these sites. After core-drilling a 117mm hole, or utilising an appropriate existing hole, the Kit simply pushes through from the inside of the building. Spring pins secure the external grille in position and the external shroud deploys around the grille covering up break-out from the external surface. Installer Friendly Quick and easy to install, the Internal Fit Wall Kit cuts down time on site when compared to traditional methods using flexi-duct. Installers no longer need to spend time fixing flexi-duct to fans and grilles using jubilee clips, or going outside to fit the grille. The tubes extend to accommodate wall thicknesses from 225mm up to 390mm and lock into position for a secure fit. The internal flange is also flexible enough to accommodate deviations in the internal surface finish. Building Regulations The external grille free area is greater than 90% of the area of the duct making it suitable for continuous running systems as well as for intermittent fans. Backdraught ShutterThe Internal Fit Wall Kit has optional backdraught shutter models. Particularly useful with intermittent fans, the backdraught shutter will ensure no draughts and gusts come in to the home through the wall kit. Models ModelStock Ref£Trade White External Grille47231841.19 Brown External Grille47231941.19 White External Grille with Backdraught Shutter474779Brown External Grille with Backdraught Shutter474780Dimensions (mm) A B A B 117 Ø 225-390 Features Rubber seal gives neat finish Locking pins securewall kit in place Fixed external grille Integral backdraught shutter(BS models) Screw fixings to securein place Easy to use measurement guide forflexible installation depth

127 Low Resistance Inlet/Outlet Air Brick •Provides over 90% free area of duct •Easier to install than a double air brick •Guide vanes for improved duct connection •Optional first fix duct section Available in five colours, this low resistance air brick has been designed to comply with the latest Building Regulations Approved Document F, which requires a ventilation outlet to achieve a minimum of 90% of the cross sectional area of the ductwork.Installing a single air brick is much simpler than a double air brick and offers more versatility for locations. Suitable for installation with round 100mm and 125mm diameter and rectangular 204 x 60mm ducting.Attaching duct to the air brick is simplified by the use of guide vanes which help locate the duct onto the spigot. A 500mm section of 204 x 60 duct is available for first fix which ensures that connections are accessible after completion of building works. Five colour options ensure that the low resistance air brick will be a match for almost any application. ModelsModelStock Ref£Trade White44922310.50 Brown44922410.50 Cotswold Stone44922510.50 Grey44922610.50 Terracotta44922710.50 1st Fix duct section4032558.25 500 x 204 x 60 Available Colours WhiteRAL 9003 Brown RAL 8017 Cotswold StoneRAL 1001 GreyRAL 7037 TerracottaRAL 8004 Performance Guide Volume l/s Pressure Loss (Pa) 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 Pressure (Pa) Volume (m 3 /h) Volume (l/s) 2.7 53.7 14.9 5.2 75.9 21.1 8.3 97.0 26.9 12.4 119.4 33.2 17.4 141.0 39.2 22.7 162.0 45.0 28.7 183.7 51.0 35.4 205.6 57.1 44.1 227.6 63.2 54.0 250.4 69.6 Dimensions (mm) A B C D 212 67 58 65

128 Flat Channel 1.5 Metre Length External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 406870 Insulated 204 x 60 160 304 1500 1 1 1.3 2.2 3.3 4.5 5.9 7.8 45.52 436617 Uninsulated 204 x 60 60 204 1500 1 1 1.3 2.2 3.3 4.5 5.9 7.8 21.61 436599 Uninsulated 110 x 54 54 110 1500 1.2 2.4 5.3 9.1 13.9 19.8 25.9 32 11.91 Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 407343 Insulated 220 x 90 190 320 1500 1.4 4.9 10.2 54.11 403025 Uninsulated 220 x 90 90 220 1500 1.4 4.9 10.2 29.71 Flat Channel Connector. F to F External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 436623 204 x 60 64 212 100 1 1 1 1 1 1 1.2 1.5 9.00 436605 110 x 54 54 114 100 1 1 1.1 1.4 2.2 3.4 4.8 6.4 2.35 Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 403026 220 x 90 95 224 52 1 1 1 8.49 Channel Fixing Clip (Pack of 10) External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 403030 220 x 90 97 44 19 N/A N/A N/A 29.71 Horizontal 90° Bend. F to F External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 406879 Insulated 204 x 60 160 360 360 0.7 1.7 4.1 8.4 13 18 25 34 31.35 436620 Uninsulated 204 x 60 65 260 260 0.7 1.7 4.1 8.4 13 18 25 34 18.69 436602 Uninsulated 110 x 54 60 152 152 2.3 9.9 21 38 64 93 124 162 5.11 Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 407342 Insulated 220 x 90 190 350 350 9 36 80 32.89 403028 Uninsulated 220 x 90 95 250 250 9 36 80 17.82 Horizontal 45° Bend. F to F External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 406876 Insulated 204 x 60 160 340 360 0.2 0.7 1.2 2.1 3.8 6.1 9.2 13 23.34 249944 Uninsulated 204 x 60 65 240 260 0.2 0.7 1.2 2.1 3.8 6.1 9.2 13 20.39 Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 449363 Uninsulated 220 x 90 95 240 200 5 20 46 25.46 Minimum insulation wall thickness 25mm. Insulation Thermal Conductivity: 0.04 W/(m.K) Ducting & Accessories

129 Horizontal T. F to F to F External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 406883 Insulated 204 x 60 160 410 355 vary on installation 28.12 436551 Uninsulated 204 x 60 65 310 255 vary on installation 20.12 436614 Uninsulated 110 x 54 60 185 150 vary on installation 7.66 Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 449365 Uninsulated 220 x 90 95 275 250 vary on installation 29.71 Vertical 90° Bend. F to F External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 406872 Insulated 204 x 60 215 310 215 1.1 2.5 5.2 9.8 16.1 24 33.6 45 24.08 436621 Uninsulated 204 x 60 115 210 115 1.1 2.5 5.2 9.8 16.1 24 33.6 45 12.01 436603 Uninsulated 110 x 54 95 115 95 3.3 15.5 36 61 96 138 190 253 4.80 Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 403029 Uninsulated 220 x 90 117 224 120 7 28 66 12.73 Vertical 45° Bend. F to F External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 406871 Insulated 204 x 60 200 310 215 0.1 0.5 1.3 2.5 4.4 6.9 10 13.3 19.15 445196 Uninsulated 204 x 60 100 210 115 0.1 0.5 1.3 2.5 4.4 6.9 10 13.3 12.72 441655 Uninsulated 110 x 54 115 115 70 1 2.4 6.6 12.9 23.1 35.1 48 64 4.53 Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 449364 Uninsulated 220 x 90 110 225 115 6 27 65 19.52 Elbow Bend. 100mm to Rectangular. M to F External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 436624 204 x 60 80 215 195 2.9 7.1 15.1 28 45.1 68.1 92.2 118 12.01 436607 110 x 54 90 115 140 3 8 17.7 33 49.9 74.5 101 137 4.96 Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 403027 220 x 90 118 226 240 N/A N/A N/A 8.49 Elbow Bend. 125mm to Rectangular. M to F External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 436625 204 x 60 80 215 195 3.1 5.9 12.2 25 43.6 62.2 86 111 12.01 Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 449361 220 x 90 118 226 240 N/A N/A N/A 8.49 Minimum insulation wall thickness 25mm. Insulation Thermal Conductivity: 0.04 W/(m.K)

130 Ducting & Accessories Elbow Bend. 150mm to Rectangular. M to F External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 436626 204 x 60 80 215 195 2.8 4.9 11.6 21 31 41 53 67 12.01 Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 449362 220 x 90 118 226 240 N/A N/A N/A 8.49 Elbow Bend. 100mm to Rectangular. F to F External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 436608 110 x 54 90 115 140 2.1 5.5 14.3 27.2 44.3 69 93 118 4.83 Flat Channel connector with Damper External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 400735 110 x 54 60 115 75 16 17.5 19.5 22 25.5 30.5 36 42 8.48 Drop down section F to F External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 442273 204 x 60 120 220 210 0.2 0.5 1.7 3.6 6.0 9.1 12.4 16.6 10.17 Single Air Brick Horizontal(System 60 Air Grille Adaptor is supplied with the Single Air Bricks) External Dimensions (mm) Resistance (Pa) at flow rate Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade A B C 436610 110 x 54 (White) 65 210 85 3.2 7.8 20.9 39 65 96 128 176 6.00 436612 110 x 54 (Terracotta) 65 210 85 3.2 7.8 20.9 39 65 96 128 176 6.00 436611 110 x 54 (Brown) 65 210 85 3.2 7.8 20.9 39 65 96 128 176 6.00 436613 110 x 54 (Beige) 65 210 85 3.2 7.8 20.9 39 65 96 128 176 6.00 Single Air Grille Soldier A B C External Dimensions (mm) Resistance (Pa) at flow rate Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 438594 204 x 60 (White) 210 65 15 3.3 10 20.6 40 63 92.8 128 168 7.48 468728 204 x 60 (Terracotta) 210 65 15 3.3 10 20.6 40 63 92.8 128 168 7.48 468730 204 x 60 (Brown) 210 65 15 3.3 10 20.6 40 63 92.8 128 168 7.48 468729 204 x 60 (Beige) 210 65 15 3.3 10 20.6 40 63 92.8 128 168 7.48

131 Double Air Brick External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size Colour A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 438604 204 x 60or220 x 90 White 145 245 80 0.2 1.6 4.3 8.7 13.9 21.1 27.5 37.4 10.50 438607 Terracotta 145 245 80 0.2 1.6 4.3 8.7 13.9 21.1 27.5 37.4 10.50 438605 Brown 145 245 80 0.2 1.6 4.3 8.7 13.9 21.1 27.5 37.4 10.50 438606 Beige 145 245 80 0.2 1.6 4.3 8.7 13.9 21.1 27.5 37.4 10.50 In conjuction with Double Air Brick Adaptor below Double Air Brick Adaptor External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 438608 204 x 60 135 226 85 - - - - - - - - 9.06 449367220 x 90 135 226 85 - - - - - - - - 10.03 Air Grille Adaptor External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 436609 110 x 54 65 210 85 0.2 1.2 2.5 4.7 7.8 11 14 18 3.88 Flexible Ducting External Dimensions (mm) Resistance (Pa) at flow rate Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 5109662 204 x 60 - - - 0.2 0.6 1.5 2.6 4.1 6.0 8.2 11.5 38.32 Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 449366 220 x 90 - - - N/A N/A N/A 29.71 Louvred Grille with Flyscreen Fitting External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 400743 110 x 54 140 140 50 5.7 14.5 37 75 120 - - - 11.79 Round (M) 100mm to Rectangular (F/M) Adaptor External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 441654 M to F 204 x 60 140 210 215 1.0 1.96 3.2 4.9 6.7 8.7 11.2 14.5 21.54 400740 M to M 110 x 54 100 115 180 1.2 4.2 8.3 19.8 29.9 42 60 86 10.44

132 Round (F) 125mm to Rectangular (F) Adaptor External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 370127 204 x 60 140 210 213 1 1 1.5 2.8 4.5 6.7 9 11.5 24.53 Round (F) 150mm to Rectangular (F) Adaptor External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 60 l/s 120 l/s 180 l/s £Trade 403031 220 x 90 160 225 203 N/A N/A N/A 12.73 Short Round (M) 100mm to 110 x 54 (F) Adaptor External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 455035 110 x 54 60 110 105 1.2 4.3 8.4 20 30.2 43 62 88 5.91 Round 2m Ducting length Insulated/Uninsulated External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 406873Insulated 100 Ø 200 200 2000 1 1 1.7 2.8 3.6 4.5 5.3 6.2 49.86 5108250 Uninsulated 100 Ø 100 100 2000 1 1 1.7 2.8 3.6 4.5 5.3 6.2 31.18 406874Insulated 125 Ø 225 225 2000 1 1 1 1.3 1.8 2.4 3.1 3.8 53.58 434715 # Uninsulated 125 Ø 125 125 1500 1 1 1 1.3 1.8 2.4 3.1 3.8 26.04 406875Insulated 150 Ø 265 265 2000 1 1 1 1 1.2 1.6 2 2.5 46.21 5108248 Uninsulated 150 Ø 150 150 2000 1 1 1 1.2 1.6 2 2.5 46.61 # 1.5 metres Equal Tee Insulated/Uninsulated MMM External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 406884 Insulated 100 Ø 290 210 235 vary on installation 22.28 372007 Uninsulated 100 Ø 190 110 135 vary on installation 16.56 406885 Insulated 125 Ø 310 215 260 vary on installation 24.40 428636 Uninsulated 125 Ø 210 115 160 vary on installation 19.93 406886 Insulated 150 Ø 335 245 285 vary on installation 30.24 370237 Uninsulated 150 Ø 235 130 177 vary on installation 29.69 Minimum insulation wall thickness 25mm. Insulation Thermal Conductivity: 0.04 W/(m.K) Ducting & Accessories

133 90° Bend Insulated/Uninsulated MM External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 406880 Insulated 100 Ø 230 200 200 2.8 5.5 11 20.3 33 45 60 79 24.08 372004 Uninsulated 100 Ø 130 100 100 2.8 5.5 11 20.3 33 45 60 79 16.35 406881 Insulated 125 Ø 260 230 230 1 1.8 5 8.2 11.8 18 26 35 22.81 427360 Uninsulated 125 Ø 160 130 130 1 1.8 5 8.2 11.8 18 26 35 20.53 406882 Insulated 150 Ø 290 255 255 1 1.0 2.5 4.1 6.4 9.6 13.5 18 21.30 370295 Uninsulated 150 Ø 190 155 155 1 1.0 2.5 4.1 6.4 9.6 13.5 18 14.51 45° Bend Insulated/Uninsulated MM External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 406877 Insulated 100 Ø 280 200 230 1 1.9 8.1 11.7 17.5 24.6 31.4 - 20.16 372005 Uninsulated 100 Ø 180 100 130 1 1.9 8.1 11.7 17.5 24.6 31.4 - 14.09 406878 Insulated 125 Ø 300 230 250 1 1 1.8 2.9 4.6 6.6 9 12.2 21.22 441657 Uninsulated 125 Ø 200 130 150 1 1 1.8 2.9 4.6 6.6 9 12.2 20.74 Connector MM External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade 372006 100Ø 100 60 - - - - - - - - - 5.42 428633 125Ø 125 60 - - - - - - - - - 6.94 370299 150Ø 150 60 - - - - - - - - - 8.26 Reducer External Dimensions (mm) Resistance (Pa) at flow rate A B C Stock Ref Duct Size A B C 8 l/s 13 l/s 21 l/s 29 l/s 37 l/s 45 l/s 53 l/s 61 l/s £Trade VA54119 125to100 130 57 - - - - - - - - - 6.11 428632 150to125 155 57 - - - - - - - - - 5.09 Minimum insulation wall thickness 25mm. Insulation Thermal Conductivity: 0.04 W/(m.K)

134 Fabric Woven PVC Flexible DuctingManufactured using fabric woven PVC with a wire helix. Used with single spigots and in multi-duct systems. Operating temperature -30°C to 70°C. 6 metre lengthsDuct SizeStock Ref£Trade 100 Ø427569 0.00 125 Ø4275700.00 150 Ø37028148.12 T-Series Flexible DuctingPVC with wire helix. For use with T-Series.6m lengthsSizeDuct SizeStock Ref£Trade Size 6175 Ø566607159.71Size 7225 Ø566609225.20Size 9300 Ø566612277.43Size 12400 Ø566616397.19 Insulated Flexible DuctingInsulated ducting should be used when duct passes through an unheated area. Minimises heat loss when used with heat recovery fans. Available in 6 diameters. An additional benefit is that thermally insulated duct offers some measure of acoustic attenuation. 10 metre lengths Duct DiaStock Ref£Trade 100 Ø561654 81.73 125 Ø561655 87.98 150 Ø561656 119.58 Duct Y Pieces For dividing a ventilation system, providing ducting to multiple supply or extract grilles using only a single fan source.2x Into1xStock Ref £Trade 100 Ø100 Ø45208158.04 100 Ø150 Ø45208260.44 125 Ø125 Ø45521158.65 125 Ø150 Ø45521256.85 150 Ø150 Ø45208363.95 150 Ø200 Ø45208465.94 200 Ø200 Ø45208566.76 200 Ø250 Ø45207865.16 250 Ø250 Ø45207684.21 250 Ø300 Ø45207969.56 Acoustic Insulated DuctingMultiple layer aluminium/polyester laminate with micro perforated flexible core to enhance acoustic performance. Core surrounded by 25mm fibreglass insulation with outer vapour barrier.Duct SizeLengthStock Ref£Trade 100 Ø1m44327328.92 125 Ø1.5m44379345.88 150 Ø1m44327432.77 ReducerDuct SizeStock Ref£Trade R125/10037030224.75 R150/10037030326.40 R150/12537030424.75 R200/15037030731.35 R250/20037030941.25 R300/10037031063.79 R300/20037031249.51 Ducting & Accessories

135 Circular Extract DiffusersManufactured from powder coated steel. Suitable for exhausting air and can be fitted directly to the duct or in the ceiling. Duct SizeStock Ref£Trade 100 Ø1054410018.30 125 Ø1054412522.18 150 Ø10544150 28.92 200 Ø1054420033.25Circular Supply DiffusersManufactured from powder coated steel. Suitable for supplying air and can be fitted directly to the duct or in the ceiling. Duct SizeStock Ref£Trade 100 Ø1054310018.85 125 Ø1054312521.34 150 Ø1054315031.81 200 Ø1054420033.25Collar for Exhaust & Supply DiffusersDuct SizeStock Ref £Trade 100 Ø3713013.20 VT100 Tile Vent 5 in 1 roof ventilation terminal kit available in grey. The kit comprises of a streamlined hood on a circular upstand with a 500 x 500mm non lead skirt and a stepped adaptor which allows connections from 100mm to 160mm diameter ducting.Stock Ref £Trade 37053890.42 Acoustic Mat 486mm x 486mm x 25mm thick foam mat for use as a resilient mounting for wholehouse units.ModelStock Ref£Trade ACM/House37017910.22

136 Spiral Ductwork - 3m lengthDuct SizeStock Ref£Trade 100 Ø40090046.21 125 Ø40090166.00 150 Ø40090282.49 200 Ø41092279.07 250 Ø41092398.55 315 Ø410924126.04 Equal Tee Duct SizeStock Ref£Trade 100 Ø40074936.30 125 Ø40075044.64 150 Ø40075151.98 200 Ø37023857.77 250 Ø37023981.21 315 Ø410925118.99 90° Bend Duct SizeStock Ref£Trade 100 Ø40075217.60 125 Ø40075323.01 150 Ø40075433.17 200 Ø37020241.28 250 Ø37020371.54 315 Ø410926117.87 Female Coupler Duct SizeStock Ref£Trade 100 Ø40075512.37 125 Ø40075612.75 150 Ø40075713.46 200 Ø41092714.39 315 Ø41092921.91 Joining Piece In sheet metal. For joining lengths of flexible ducting to give long lasting airtight connection.Duct SizeStock Ref£Trade 100 Ø56180413.36 125 Ø561805 16.12 150 Ø56180618.84 200 Ø56180819.79 250 Ø56181026.81 315 Ø56181332.22 Rectangular Balancing DamperDuct SizeStock Ref£Trade 110 x 5440515647.36 204 x 6040369862.70 220 x 9040369969.30 Circular Balancing DamperDuct SizeStock Ref£Trade 100 Ø40075836.08 125 Ø40075947.22 150 Ø40076048.72 200 Ø41093054.62 250 Ø41093164.12 315 Ø41093271.29 Galvanised Spiral Wound Ducting

137 Fire Stopping – Round and Flat Ducting Fire Rated DiffusersExtractExtractSupplySupply Duct SizeStock Ref£TradeStock Ref£Trade 100 Ø40343161.8747566161.87 125 Ø40343282.4947566282.49 150 Ø40343395.7647566395.76 200 Ø408828 109.74475664109.74 Round Fire SleeveThickness:10-15mm Length:280mm (180mm 407655) CE MarkedDuct SizeStock Ref£Trade 100 Ø40765560.56 125 Ø40765686.13 150 Ø407657121.66 Rectangular Fire Sleeve - 4 sided Thickness:10-15mmLength:180mm CE MarkedDuct SizeStock Ref£Trade 110 x 5440765836.71 204 x 6040765952.52 220 x 9040766089.27 Rectangular Fire WrapDuct SizeStock Ref£Trade 204x60mm43513867.13 Pyrocheck Duct SizeStock Ref£Trade 4” ØCVT10057.48 5” ØCVT13066.33 Vent-Axia provides a complete range of fire stopping products specifically tested with ventilation ducting. This versatile selection allows for stacking and parallel installation in certain circumstances, along with creative solutions for partition walls and slab mounting. The table highlights the type of fire stopping required for most common applications. Minutes Protec- tion Fire Valves Round Fire Sleeve 100mm 125mm 100mm 125mm 150mm 130mm StudPartition 30 407655407657 60 407656 120 130mmMasonary 30 407655407657 60 407656 120 140mmMasonary 30 407655407657 60 407656 120 Ceilings 30 403431 403432 60 120 Minutes Protec- tion Rectangular Fire Sleeve Rectangular FireWrap 110 x 54 204 x60 220 x90 110 x 54 204 x60 72mm StudPartition 30 407658 407659 407660 60 120 100mm StudPartition 30 407658 407659 407660 60 120 130mm StudPartition 30 407658 407659 407660 404276 404274 60 120 130mmMasonary 30 407658 407659 407660 435137 435138 60 120 140mmMasonary 30 407658 407659 407660 435137 435138 60 120 Fire Test Assessment also covers multiple flat ducts to be installed in series / side by side, max. 3No., 30, 60 & 120 Minute Partitions, Single & Double Boards.Note: For a copy of the Fire Certificates for the product(s) above, visit our webpagewww.vent-axia.com/range/ventilation-fire-stopping.Vent-Axia does not guarantee compliance with Building Regulations Part B, Fire Spread or other regulations that relate to fire planning. Suitability to comply with these regulations should be determined prior to installation and in conjunction with Building Control Officers. Compliance with the Regulations is specifically excluded from quotations and designs.

138 Wall Fitting Kit A range of wall kits suitable for Vent-Axia range of 100 and 150mm fans. The kit can be installed into most walls using the telescopic liners supplied.White ModelStock Ref£Trade VA10025410221.55 Silhouette 12545522624.43 VA140/15014090224.70 Silhouette 15014090224.70 Brown ModelStock Ref£Trade VA10025410021.55 VA140/15014090324.70 Silhouette 150140903 24.70 Window Fitting Kit For use in single or sealed double glazing and most materials up to 40mm thick. White ModelStock Ref£Trade VA100 (105Ø)25410121.55 VA100 (110Ø)44323423.32 Centra/Sil 100442947 23.32 VA140/15014090124.70 Solo Pro1146168520.20 Air Grille Louvre grille for external termination of 100mm diameter rigid ducting. Consists of wall mounting piece and grille with 2 fixing screws. Colour:White or Brown Dimensions:155 x 155 x 32mm Material:ABS plastic ColourStock Ref£Trade White56351115.14 Brown56350015.14 Termination Set Used as a decorative inlet grille or soffit termination set in conjunction with 100mm or 125mm diameter ducting. Two fixing screws supplied to secure grille to the spigot through material up to 25mm thick.Dimension 155mm x155mm. Colour:White Material:ABS plastic Stock Ref £Trade 563513 29.21 . 100mm & 150mm Accessories

139 Decoration Frame A decoration frame that converts old Centrif to new Centrif Duo without the need to redecorate. The frame can be used with Quadra and Centrif Duo Plus. The frame is simply installed using two wall fixing screws, allowing the fan to be mounted via it’s standard mountings. Finished in a high moulded material plastic colour matched to the fan. Color: White Size:386mm x 296 x 32 mm deepStock Ref £Trade 442551 20.29 Quick Fit 100mm Airflow ShutterShutter with gravity flaps to protect against backdraught.The spigot connects to 100mm rigid ducting using quick fix grips provided. Dimensions:155 x 155 x 20mm Material:Plastic ColourStock Ref£Trade White563522 15.61 Brown563542 15.61Terminal Connector & GrilleUsed for the termination of 100mm flexible ducting to the ceiling or wall of small areas, such as internal toilets. Connector:Manufactured in high impact thermoplasticColour:Grey Grille:ABS plastic eggcrate, white finish Description Stock Ref£Trade Grille 56084628.64 Connector56085656.55 External Terminationslouvre Grilles with SpigotPlastic louvre grilles with either 100mm or 150mm diameter spigots. Duct SizeModelStock Ref£Trade 100 ØRD104TC Terracotta370328 7.22 100 ØRD104BR Brown370329 7.22 100 ØRD104WH White3703306.98 Duct SizeModelStock Ref£Trade 150 ØRD604TC Terracotta37033811.79 150 ØRD604BR Brown37033711.79 150 ØRD604WH White37033911.79

140 Quick Fit 100mm GrilleTerminates a rigid duct on an outside wall using the ‘quick fix’ side grips without the need for additional fixings.ColourStock Ref£Trade White56352115.61 Brown56354115.61 Vent Cowl External termination for 110mm diameter rigid ducting through roofs and walls in exposed situations. Overall diameter 200mm. Not suitable for use with flexible ducting.MaterialStock Ref£Trade Grey PVCu56140331.88 White457845 29.79Quick Fix TerminationThe quick fix termination is designed to be installed from inside the building to a nominal 117mm or 165mm diameter core-cut hole, saving time and cost. Four sealing rings ensures a weather tight fit to the wall external leaf. Effective length 370mm.Duct SizeStock Ref£Trade 100 Ø56353539.11 150 Ø43465651.42 Air Replacement Set Bathroom and toilet ventilation is only effective when there is adequate air replacement into the room. This is often most effectively achieved by fitting a pair of air replacement grilles at low level in a door. Consists of a two piece telescopic set which fits unobtrusively on either side of the door panel. Minimum fixing thickness:30mmDimensions:454 x 90mm Hole size:4 35 x 76mm Material:HIPS / High Impact Polystyrene Free area: 16,600mm 2ColourStock Ref£Trade Brown56140024.39 Ivory56140124.39 Condensation Trap Condensation trap, for fitting in vertical rigid PVCu pipe ducting. Must be used where pipe ducts pass through unheated roof voids. Fitted with 20mm pipe connection for running off condensate. Not suitable for use with flexible ducting.Length:85mmMaterial:Grey PVCu SizeStock Ref£Trade 110mm56351615.18 125mm45519118.17 150mm45519021.21 100mm & 150mm Accessories

141 Wind Baffles A range of 100mm and 150mm wind baffles. Cowled wall outlet with damper protected gravity grille. Available in white and brown they are ideal for exposed coastal applications, helping to prevent unwanted backdraughts. 100mmColourStock Ref£Trade White4520948.65 Brown4520958.65 150mmColourStock Ref£Trade White45209615.49 Brown45209715.49 Wind Baffle Kits 100mm wind baffle kit consisting of a telescopic wall tube and wind baffle. Available with either a white or brown wind baffle.ColourStock Ref£Trade White40738219.95 Brown40757719.95 VA140/150 Window wind cowlWind cowl for exposed areas.Stock Ref £Trade 455262 55.18

ElectricHeating Vent-Axia heating is ideal for residential or commercial applications. So whether it’s a bedroom or hallway, office or shop, we can provide the solution.The simplicity of installing electric heating, particularly in high rise apartments means it is the natural choice for your project.Comfort heating products with innovative zone control features provide energy savings for the occupier without compromising comfort in the home, coupled with low capital outlay they offer a cost effective solution for installer and occupier. With a slim, stylish design our Opal Aluminium Radiator range offers households attractive, energy efficient comfort. Featuring an advanced digitally controlled thermostat, the Opal range gives you one of the most cost effective and energy efficient electric heating systems available.

Bluethermal ®Underfloor Heating 144-149 Heated Towel Rails 150-151 Radiant Heaters 152-153 Opal Aluminium Radiators 154 Optimax ®Plus Panel Heaters 155 Optimax ®Plus Combination Storage Heaters 156 Optimax ®Plus Storage Heaters 157 Plinth Heaters 158 Warm Air Curtains 159 Convector Heater 160 Portable Fan Heater 161

144 Bluethermal Underfloor Heating Mat •Energy efficient•Maintenance free •Zone controllable•Easy to install adhesive mats •Offers design freedom by removing radiators • 100W/m 2& 150W/m 2options available•2.5m cold lead cable •Controller & insulation board available •10 Years warrantyBluethermal Mat Thin Twin Conductor Heating MatRenovating with Heating MatsMinimum floor thickness can be important in renovation processes in order to avoid extra work on doors and thresholds. For these projects our Bluethermal ®Mat range is the ideal product. The heating mat consistsof a thin twin conductor heating cable attached to an adhesive flexible glass fibre net. The thin heating cable has a total thickness of only 4mm, is delivered with a 2.5m cold lead and has a width of 0.5m. The 100W/m² mat can be installed on any type of levelled and stable sub floor, and can also be used under parquet or other wooden floor coverings. The 150W/m² must be installed on a non-combustible levelled and stable sub floor. With all our products we recommend the use of our Bluethermal ®Thermostatic Controller thermostat with a temperature limitingfunction. 10 year WarrantyVent-Axia offers a 2 year standard warranty on underfloor heating and their components from the date of purchase. A 10 year extended warranty is also available upon completing the ‘Warranty Form’ found in the Fitting and Wiring Instructions. Construction:•Solid resistance wires •FEP insulation •Solid copper earth wire •Fibre-glass net •PVC outer jacket •Aluminium sheath •Cable thickness is 4mm•Mat width 0.5m (19.7”) Technical Data:•Area load 100W or 150W/m² (9.3 or 14.0W/sq.ft.) •Loads from 100W to 1800W •Max. continuously operating temperature outer jacket: 65°C •Tolerance on conductor resistance: -5 / + 10 % •Rated voltage: 230V

145 Installation Detail Floor coveringTile adhesive Recommended screed depth 10-30mm Bluethermal ®Mat 4mm Insulation board Stable and levelled sub-floor 1 2 3 4 5 6 1 2 3 4 5 6Performance Guide StockMat Area Output Dimensions m Element Nom.Ref Model m 2W W LResistance Ω £Trade 446175 VAUFHM 100 1.0 100 0.5 2 529.0 88.63 446176 VAUFHM 100 1.5 150 0.5 3 352.7 103.77 446177 VAUFHM 100 2.0 200 0.5 4 264.5 118.91 446178 VAUFHM 100 2.5 250 0.5 5 211.6 134.08 446179 VAUFHM 100 3.0 300 0.5 6 176.3 149.23 446180 VAUFHM 100/HS 3.5 350 0.5 7 151.1 164.38 446181 VAUFHM 100/HS 4.0 400 0.5 8 132.3 179.54 446182 VAUFHM 100/HS 5.0 500 0.5 10 105.8 209.81 446183 VAUFHM 100/HS 6.0 600 0.5 12 88.2 240.13 446184 VAUFHM 100/HS 7.0 700 0.5 14 75.6 266.32 446185 VAUFHM 100/HS 8.0 800 0.5 16 66.1 300.74 446186 VAUFHM 100/HS 10.0 1000 0.5 20 52.9 361.34 446187 VAUFHM 100/HS 12.0 1200 0.5 24 44.1 421.95 446188 VAUFHM 150 1.0 150 0.5 2 352.7 98.47 446189 VAUFHM 150 1.5 225 0.5 3 235.1 115.30 446190 VAUFHM 150 2.0 300 0.5 4 176.3 132.14 446191 VAUFHM 150/HS 2.5 375 0.5 5 141.1 148.97 446192 VAUFHM 150/HS 3.0 450 0.5 6 117.6 165.81 446193 VAUFHM 150/HS 3.5 525 0.5 7 100.8 182.64 446194 VAUFHM 150/HS 4.0 600 0.5 8 88.2 199.48 446195 VAUFHM 150/HS 5.0 750 0.5 10 70.5 233.14 446196 VAUFHM 150/HS 6.0 900 0.5 12 58.8 266.82 446197 VAUFHM 150/HS 7.0 1050 0.5 14 50.4 300.49 446198 VAUFHM 150/HS 8.0 1200 0.5 16 44.1 334.15 446199 VAUFHM 150/HS 10.0 1500 0.5 20 35.3 401.49 446200 VAUFHM 150/HS 12.0 1800 0.5 24 29.4 468.85 HS = hidden splice The mats are equipped with a 2.5m cold leadConvection Heating and Underfloor Heating Comparison HeatingwithConvection 21 ºCAir Temperature18 ºCPerceivedTemperature15 ºCSurfaceTemperatureHeating withUnderfloorHeating 19 ºCAir Temperature19 ºCPerceived Temperature24 ºCSurface Temperature

146 Bluethermal Cable Twin Conductor Cable For Direct HeatingRenovation with Heating CablesWhen renovating with our Bluethermal ®Cable range, apply thecable to a non-combustible subfloor (minimum thickness 5mm) and take into consideration the placement of permanent installations such as showers, baths, toilets, cupboards etc. Place the end seal away from potentially wet areas of the floor. See ‘Installation Example’ on the next page detailing the placement of a free laid heating cable. Note that the cable is not crossing or touching itself, this is to provide the best possible heat conductivity to the surroundings of the cable.The heating cable is embedded in a screed/concrete with low overall construction height. After drying and hardening, a moisture barrier/membrane can be put on top of the screed/concrete before the floor covering is installed. 10 year WarrantyVent-Axia offers a 2 year standard warranty on underfloor heating and their components from the date of purchase. A 10 year extended warranty is also available upon completing the ‘Warranty Form’ found in the Fitting and Wiring Instructions. Construction:•Solid resistance wire •XLPE insulation •Tinned copper drain wire•Aluminium screen •PVC outer jacket •Cable thickness is 7mm Technical Data:•Series resistance, element values from 300W to 3300W •Linear load: 17W/m (5.2W/ft) •UV resistant •Max. cont. operating temperature outer jacket: 65°C (149°F) •Min. bending radius: 5 x cable diameter •Tolerance on conductor resistance: - 5 / + 10 % •Highest system voltage: 300/500V •Rated voltage: 230V Bluethermal Underfloor Heating Cable •Energy efficient•Maintenance free •Zone controllable•Allows for application in tight areas •Offers design freedom by removing radiators • 100W/m 2& 150W/m 2options available•2.5m cold lead cable •Controller & insulation board available •10 Years warranty

147 Installation Detail 1 2 3 4 5 6 1 2 3 4 5 6 Floor covering Tile adhesive Recommended screed depth 40-60mm Bluethermal ®Cable 7mm Insulation board 5-10mm stable and levelled subfloorPerformance Guide Stock Load @ 230V Element Length Element Nom Outer Diameter Ref Model W m ft Resistance Ω mm £Trade 446201 VAUFHC 300 17.6 58 176.30 7 102.67 446202 VAUFHC 400 23.5 77 132.30 7 112.00 446203 VAUFHC 500 29.3 96 105.80 7 117.87 446204 VAUFHC 600 35.2 115 88.20 7 130.59 446205 VAUFHC 700 41.0 135 75.60 7 136.52 446206 VAUFHC 840 49.7 162 63.00 7 153.19 446207 VAUFHC 1000 58.3 191 52.90 7 179.28 446208 VAUFHC 1250 72.4 237 42.30 7 200.07 446209 VAUFHC 1370 80.8 265 38.60 7 222.71 446210 VAUFHC 1700 100.0 328 31.10 7 243.22 446211 VAUFHC 2100 123.7 405 25.20 7 289.71 446212 VAUFHC 2600 154.5 507 20.30 7 322.67 446213 VAUFHC 3300 194.0 615 16.00 7 422.52 The cables are equipped with a 2.3m cold lead Convection Heating and Underfloor Heating Comparison HeatingwithConvection 21 ºCAir Temperature18 ºCPerceivedTemperature15 ºCSurfaceTemperatureHeating withUnderfloorHeating 19 ºCAir Temperature19 ºCPerceived Temperature24 ºCSurface TemperatureInstallation Example 1 1 2 2 3 3 4 4 5 5 6 6

148 Applications Precise and accurate temperature control is important to fully achieve the advantages of underfloor heating, without using more electric energy than necessary.The use of heating mats and cables in combination with an accurate thermostat can provide an energy efficient and comfortable floor heating solution for most modern buildings. Specifications•Accuracy: +0.5°C / 1°F •Maximum load: 16A or 3.2kW •Power supply: 230V •Dimensions: 86 x 86 x 13mm (WxHxD) •IP24 ratedModelStock Ref£Trade VAUFHTC44617492.68 Splicing Kit In the unlikely event that you need to repair your heating cables, this kit provides you with the necessary joints to get your systems back running. ModelStock Ref£Trade VAUFHS446214 37.83 Recommended Application GuideOutputMin W/m 2OutputMax W/m 2 Model Application VAUFHM100 VAUFHM150 VAUFHC Entrance/Hall 80 150 X X Entrance/Porch 120 150 X X Hall/Corridor 80 100 X X Living Room 70 100 X X Kitchen 70 100 X X WC 120 150 X X Utility Room 120 150 X X Bedroom 70 100 X X Bathroom 120 150 X X Office 80 100 X X Storage Room 80 100 X X Shop 80 100 X X Workshop 80 100 X X Bluethermal Thermostatic Controller •Large screen with blue backlighting •4-event programme or constant temperature control •Clock: 12 hours (am/pm) / 24 hours •Day display: Monday - Sunday •Celsius or fahrenheit display selection •Frost protection setting •5 - 40°C working range (default)

149 ApplicationsOur insulation boards limit the downward heat loss within the system directing the heat to where you need it.Vent-Axia underfloor heating insulation boards are recommended for use with our products to increase the efficiency and minimise the warm up time of the system, saving both energy and money. They are available from 6mm to 70mm thick. Fixing to Wooden Floors By Adhesive - The boards must be laid onto a level floor, with a suitable flexible rapid set cementitious tile adhesive – solvent based or ready mixed adhesives MUST NOT be used.By Mechanical Fixing - The boards (other than 6mm boards) can be installed with mechanical fixings only to flat and level timber floors using approximately 12 fixings per 1200mm x 600mm board, with suitable screws and a 35mm fixing washer under the head. Fixing kits are available as detailed in the table to the right. Fixing to Concrete Floors A suitable flexible rapid set cementitious tile adhesive should be used – solvent based adhesives or ready mixed adhesives MUST NOT be used.Vent-Axia Underfloor Heating Insulation BoardsStock Ref Model Thicknessmm Numberof boardsper box Pack coveragem 2 U-Value W/m 2 /K £Trade 447267 VAUFHIB6 6 8 5.76 4.5 166.27 447268 VAUFHIB10 10 6 4.32 2.7 124.70 447269 VAUFHIB12 12.5 6 4.32 2.16 146.84 447270 VAUFHIB20 20 6 4.32 1.35 159.61 447271 VAUFHIB30 30 4 2.88 0.9 124.70 447272 VAUFHIB40 40 3 2.16 0.67 110.13 447273 VAUFHIB50 50 2 1.44 0.54 82.26 447274 VAUFHIB60 60 2 1.44 0.45 92.68 447275 VAUFHIB70 70 2 1.44 0.39 113.14 Vent-Axia Underfloor Heating Insulation Board AccessoriesStock Ref Model Type To be usedwith insulationboard Size£Trade 447277 VAUFHIB10S Screws VAUFHIB6-12 25mm (L) 15.91 447278 VAUFHIB20S Screws VAUFHIB20 35mm (L) 16.94 447279 VAUFHIB30S Screws VAUFHIB30 45mm (L) 18.74 447280 VAUFHIB40SScrews VAUFHIB40 60mm (L) 20.11 447281 VAUFHIB50SScrews VAUFHIB50 65mm (L) 20.11 447282 VAUFHIB60S Screws VAUFHIB60 75mm (L) 25.05 447283 VAUFHIBWWashers All 35mmØ 21.93 447276 VAUFHIBT Tape All 100mm (W)x 50m roll (L) 19.91(50 per pack) Bluethermal Insulation Boards •Increases the efficiency of any Underfloor Heating system •Variety of sizes to suit any project •Minimizes downwards heat loss

150 Range OptionsVent-Axia Heated Towel Rails quickly warm and dry towels. Their presence on the wall also adds to the overall style, temperature and comfort of the room. This comprehensive range of white and chrome towel rails offers 10 different models across the flat, curved and designer ranges. The range offers sizes from 500 x 600mm to 500 x 1500mm available in four heat outputs of 100, 150, 250 and 400W matched to the size of the rail. Controller The range is complemented by an advanced controller available in white and chrome giving you control of five heat outputs. The controller also offers an eco mode ideal for use when drying your towels to ensure minimal energy use. This feature turns on the rail on full power for 30 minutes then reduces the output to the user setting for a further 90 minutes before turning the towel rail off. •IPX4 rated•White or chrome finish•Five power settings•Eco timed function•Two year warranty ModelStock Ref£Trade VATRCW White44786466.54 VATRCC Chrome44786590.08 Heated Towel Rails •IP55 rated •Wall fixings included •Plug and vent included •Five year leakage warranty •One year manufacturer’s guarantee •Heating element included •Stylish designs •Steel construction with high quality white and chrome finishes •Production is carried out using latest technology resulting inabsolute consistency in quality •Complete fitting set supplied

151 Dimensions mm Output Stock Ref Model Description Finish W H W £Trade 447854 VATRS100C ‘S’ ShapeChrome 600 500 100 126.26 447855 VATRF150C FlatChrome 400 700 150 168.47 447856 VATRF250W White 500 1100 250 158.29 447857 VATRF250C Chrome 500 1100 250 217.99 447858 VATRF400C Chrome 500 1500 400 309.74 447859 VATRC250C CurvedChrome 500 1100 250 227.13 447860 VATRC400C Chrome 500 1500 400 322.23 447861 Atacama LS DesignerChrome 400 700 150 257.95 447862 Atacama OS Chrome 300 650 150 265.28 447863 Atacama SS Chrome 500 1000 250 266.36 447864 VATRCW ControllerWhite single gang n/a 66.54 447865 VATRCC Chrome single gang n/a 90.08 447866 VATRDFK150 Replacement element /dual fuel kit n/a n/a 150 62.04 447867 VATRDFK250 n/a n/a 250 64.53 447868 VATRDFK400 n/a n/a 400 66.96 Specification Heated Towel Rail Range S-shaped chrome VATRS100CStock Ref£Trade 447854126.26 Flat chrome VATRF150CStock Ref£Trade 447855168.47 Flat white VATRF250WStock Ref£Trade 447856158.29 Flat chrome VATRF250CStock Ref£Trade 447857217.99 Flat chromeVATRF400CStock Ref£Trade 447858309.74 Curved chrome VATRC250CStock Ref£Trade 447859227.13 Curved chromeVATRC400CStock Ref£Trade 447860322.23 Flat designerAtacama LSStock Ref£Trade 447861257.95 Oval designerAtacama OSStock Ref£Trade 447862265.28 Flat designerAtacama SSStock Ref£Trade 447863266.36

152 Profile Our radiant heating product range gives the flexibility to deal with large and small unheated spaces which would be uneconomical to heat using traditional space heating.Areas such as bars, restaurants, terraces, delivery areas, warehouses and churches are some examples where our radiant heating products will provide an economical heating solution. Radiant heat and its advantages The heat we feel from the sun is called radiant heat and is part of the electromagnetic spectrum called infrared. Ultra violet and visible light also belong to the same family.Visible light is the easiest part of this spectrum to understand, light travels in a straight line from the source, is unaffected by air and is invisible until it hits a surface. Shadows are a good example of this and are the absence of light.Infrared rays behave in the same way, we cannot see them but we can feel them as warmth. A good example of this is the effect created when you move from the shade into the sun, although the temperature is the same, the perceived temperature when in direct sunlight is much higher. This phenomenon makes sunbathing possible during winter holidays.There are three categories of infrared; short wave (IR A), medium wave (IR B) and long wave (IR C), the shorter the wave length the easier it travels through the air. The advantage when using short wave infrared heating is that the rays cut through the air and are not affected by air movement and only transmits its energy when it collides with a solid object. The rays also travel in a straight line so can be directed where you need it, ideal in locations which feature high ceilings, have high air change rates orare outside. Convection Heating and Radiant Heating Comparison HeatingwithConvection 21 ºC AirTemperature18 ºC Perceived Temperature15 ºC Surface Temperature15 ºC AirTemperature18 ºC PerceivedTemperature21 ºC SurfaceTemperatureHeating with theRaditant Effect Wave Infrared comparison Short WaveInfrared Medium WaveInfrared Long WaveInfrared Typical source IR Halogen Lamp Quartz HeatSource Resistance Materials Tungsten Filamentwelded in aquartz tube Filament incompound of Fe-Cr-Al in aquartz tube Filament incompoundofFe-Cr-Al in asteel tube Radiant efficiency 92% 60% 40% Switch on/off times 1 second 30 second 5 minutes Radiant Heaters •Economical and easy to install •Silent in operation •No yearly maintenance cost •Shortwave IR halogen lamp •One second heat up time •Precision heating directed where you need it •Up to 5000 hours element life span •IP65 rated (VARO model)

153 Technical Details Weight Luminous Output Heating Replacement Stock Ref Model kg Voltage rating Bulb spectrum Accessories W Amps range m 2 elements 447600 VAR0 1800 1.0 230V ~ 50-60Hz gold x1 IR-A wall bracket 1800 8 8-10 VARO 447606 447602 VARI 2000 2.2 220-240V - 50-60Hz gold x1 IR-A wall bracket 2000 9 9-12 VARI 447605 447603 VARI 4000 3.0 220-240V - 50-60Hz gold x1 IR-A wall bracket 4000 18 12-16 VARI 447605 447604 VARI 6000 3.8 380-415V - 50-60Hz gold x1 IR-A wall bracket 6000 27 16-20 VARI 447605 Dimensions (mm) Stock Ref A B C 44760083 836 112 Stock Ref A B C 447602235 313 486 447603 376 313 496 447604 515 313 496 Radiant Heater Range ModelStock Ref£Trade VARO 1800447600149.36 ModelStock Ref£Trade VARI 4000447603349.26 ModelStock Ref£Trade VARI 2000447602239.31 ModelStock Ref£Trade VARI 6000447604456.78

154 ApplicationsThe Vent-Axia Opal range of Aluminium Radiators offers a slim stylish design with advanced digital thermostatic control giving you one of the most cost effective and energy efficient electric heating systems you can have. Popular with specifiers, contractors and home owners, the Opal range is ideal for new build and refurbishment. Available in five sizes, our range provides a solution for any size room with outputs from 500W - 1500W. All of the Opal Aluminium Radiators controllers are fully programmable offering closer management of energy control with resultant costs savings. This can be measured with the on-board energy monitor allowing you to see how much energy you are using to heat your room. All standard units come with all the features and controls you would expect to see on an advanced heating system.Energy Saving Electronic Control Accurate, fast acting control is essential for reducing temperature overrun and minimising energy consumption. The silent operating electronic thermostat is accurate to +/- 0.5˚C and acts quickly to maintain consistent temperature levels. Room Temperature °C Time Comfort level Mechanical thermostatElectronic thermostatEnergy saved 23 21 19 Seven Pre-set Lifestyle Heat Schedules The heater is pre-programmed with seven heating plans, with two of them being adjustable to meet your own needs. The five pre-set programmes are adapted to most heating situations. The seven plans are described in the table on the right. Heating schedule PLnF is pre-programmed for when you are away from your home for a long period of time and would like to protect it against freezing. The green economy LED will flash. Heating schedule PLUE is designed for weekends. With this plan the heater is pre-programmed to work from Monday to Thursday in the antifreeze position. From Friday through to Sunday you can configure the programme according to your own needs. Should the pre-set schedules not meet your heating requirements, the PLCF heating plan enables you to create your own heating schedule. Weekdays/hrs Weekend/hrs Comfort Economy Anti-freeze PLO1 PLO2 PLO3 PLO4 PLnF PLUE PLCF 0612 18 24 0612 18 24 Monday to Thursday Friday Specification Weight Dimensions (mm) Output Stock Ref Model kg H W D W Amps£Trade 448469 VAAR500500W11584 460 96 500 2.3 339.23 448470 VAAR750750W15 584 620 96 750 3.4 390.22 448471 VAAR10001000W19 584 780 96 1000 4.5 453.68 448472 VAAR12501250W23 584 940 96 1250 5.7 518.28 448473 VAAR15001500W27 584 1100 96 1500 6.8 586.83 Opal Aluminium Radiators •Aluminium block with innovative curved elements•Digitally controlled thermostat•Dynamic fluid with high thermal inertia•Temperature setting; Comfort, Economy, Anti-Freeze•Seven pre-set heating schedules, including two programmable options•Outputs from 500W - 1500W•Safety thermal regulator•Supplied with wall mounting brackets and 0.7m power cable •IP24 Rated •Safe, clean and easy to operate •All radiators are powder coated externally in white (RAL 9016)

155 Optimax Plus Panel Heater •Integral adjustable thermostat •Optional integral timer model•Frost protection setting of 5˚C •BEAB approved •Unique quick fix wall bracket•Colour RAL 9001 •Ideal complement to storage heaters •Brackets for panel included •IP24 rated Comfort Heating Our Optimax Plus Panel Heaters are perfect for smaller rooms such as bedrooms, studies, conservatories and loft conversions.Vent-Axia’s Panel Heaters offer a wide range of heat outputs from 750W to 2000W and every model is available with or without a timer.Vent-Axia Panel Heaters look as good as they perform. Stylish and slim, they occupy minimal wall space and are finished in an attractive white finish.Vent-Axia Panel Heaters are wall mounted and connected to the permanent electrical supply via a fused connection switched outlet. Vent-Axia Panel Heaters are supplied with mounting brackets and one metre of cable connected to the bottom right hand side of the unit. Adjustable Thermostat All Vent-Axia Panel Heaters have a built-in adjustable thermostat offering a full temperature range, including a frost protection setting of 5˚C.For maximum safety there is a thermal cut-out on all models to prevent overheating should the outlet grille be accidentally covered. Specification Output Weight Stock Ref Model kW kg 439034 / 439038 VAPH 075/T 0.75 6.2 439035 / 439039 VAPH 125/T 1.25 6.6 439036 / 439040 VAPH 150/T 1.5 6.6 439037 / 439041 VAPH 200/T 2 8.0 220-240V-50Hz. BEAB Approved. Dimensions (mm) D E F G B C Stock Ref A B C D E F G 439034 / 439038 620 430 108 118 288 214 255 439035 / 439039 690 430 108 118 358 214 255 439036 / 439040 690 430 108 118 358 214 255 439037 / 439041 860 430 108 118 528 214 255 ModelsManual and Timer versions available.ModelStock Ref£Trade VAPH 075439034104.75 VAPH 075T439038135.14 VAPH 125439035117.35 VAPH 125T439039147.69 VAPH 150439036127.78 VAPH 150T439040159.23 VAPH 200439037133.03 VAPH 200T439041166.54

156 Optimax Plus Combination Storage Heater •Optimised charge period offers 15% energy saving •Reduced installation times •Conveniently mounted controls •Range of three heat outputs •Colour RAL 9001 •IP20 rated •BEAB approved Comfort Heating Vent-Axia Combination Storage Heaters take advantage of low tariff night-time electricity in the same way as our domestic storage heaters.They combine the benefit of a domestic storage heater and a convector heater in one casing. The storage heater offers comfortable heat around the clock taking advantage of low tariff electricity.The convector heater can be switched on at any time to offer additional heat when required, or used outside the normal heating season for instant heating. Combination Heaters require a permanent power supply for immediate convection heating when required. The storage heater section has a separateoff-peak supply. Ease of InstallationFeatures such as snap-on feet, simple wall fixings and quick assembly mean that new installations or replacement of existing units are completed with minimum disruption. The cable entry is located at the back of the unit on the bottom right hand side. All models incorporate an ambient thermostat which optimises the charge to suit room conditions, typically saving an additional 15% in energy costs. Vent-Axia Combination Heaters are slim, compact and aesthetically pleasing. Their attractive neutral finish blends in with a variety of decors. The controls are conveniently positioned on top of the heater for ease of use. Once the optimum settings are selected, no further adjustment is necessary. A separate convector heater On/Off switch is situated on the side of the casing together with a thermostat for temperature control.Models Combination HeatersModelStock Ref£Trade VACSH 12A438919551.15 VACSH 18A438920646.51 VACSH 24A438921777.75 Dimensions (mm) 75min. W all or fur nitur e Shelf or overhang 250min. 150 Stock Ref A B C 438919 540 730 185 438920 765 730 185 438921 990 730 185 Specification Input Weight Number Stock Ref Model kW Output kW kg of bricks 438919 VACSH 12A 1.70 1 79 8 438920 VACSH 18A 2.55 1.5 116 12 438921 VACSH 24A 3.40 2 152 16220-240V-50Hz.BEAB Approved. 150min. 88Furniture or other obstruction

157 Optimax Plus Storage Heater •Perfect for offices and homes •Optimised charge period offers 15% energy saving •Reduced installation times•Conveniently mounted controls •Range of four heat outputs •Colour RAL 9001 •IP20 rated Comfort Heating Vent-Axia Storage Heaters are often an economic alternative for new build or in existing properties, particularly where no other fuel source is available. Vent-Axia Storage Heaters are simple to install, economical to run and virtually maintenance free. Ideal for use in living rooms, hallways and landings. The range can be installed in bathrooms outside Zone 2, provided that the installation complies with IEE regulations.Vent-Axia Storage Heaters offer comfortable warmth around the clock taking advantage oflow-tariff electricity. Ease of InstallationSimple to install wall fixings and quick assembly mean that new installations or replacement of existing units are completed with minimum disruption. The cable entry is located at the back of the unit on the bottom right hand side. The automatic Optimax Plus storage heaters incorporate an ambient thermostat which optimises the charge to suit room conditions, typically saving an additional 15% in energy costs.Vent-Axia storage heaters are slim, compact and aesthetically pleasing. Their attractive neutral finish blends in with furnishings.The controls are conveniently positioned on top of the storage heater for ease of use. Once the optimum settings are selected, no further adjustment is necessary.Models ModelStock Ref£Trade VASH 6A438673247.35 VASH 12A439359 418.59 VASH 18A439360 527.61 VASH 24A439361642.52 Dimensions (mm) 150min. 88Furniture or other obstruction 75min. W all or fur nitur e Shelf or overhang 250min. 150 Stock Ref A B C 438673 332 700 170 439359 560 700 170439360 788 700 170 439361 1016 700 170Specification Input Weight Number Stock RefModelkW kgof bricks 438673VASH 6A 0.85 41 4 439359VASH 12A 1.70 77 8439360VASH 18A 2.55 110 12 439361VASH 24A 3.40 145 16220-240V-50Hz.

158 Vent-Axia Plinth Heaters are designed for use in kitchens and bedrooms. They fit neatly into most types of fitted furniture, fascias, display units and false walls. When installed in a corner with an adjacent cupboard to the right, a distance of at least 150mm must be maintained between the right hand end of the heater and the front of the adjacent cupboard door. Vent-Axia Plinth Heaters are supplied with 1.5m of 1mm 23 core cable,terminating on the right hand side of the unit. ModelsThermostatic ModelsModelStock Ref£Trade VAPL2TC-S459115122.65 VAPL2TC-W459116119.08 VAPL2TC-B459117122.65Dimensions (mm)500 Front Top 97 165 320 Weight:3kgCut Out (WxH):470x85mm Plinth Heaters •Ideal for where wall space is at a premium •Finishes: Stainless steel, Brown or White •Optional thermostatic control 5-30˚C •Can be used with remote switch VARSU 436494 •Two heat settings 1kW & 2kW •Fan only mode

159 Warm Air Curtains •Integral switching for faster installation •Three heat settings and fan only mode •Models to suit single and double doorways •Suitable for use as a high level fan heater Vent-Axia Warmair Curtains provide a heated downflow of warm air in doorways of commercial premises such as shops, offices and schools. The robust outer case is made from painted steel with an off white epoxy finish. Accommodating varying door widths is easily achieved by installing Warmair units ‘side by side’. Vent-Axia Warmair Curtains are supplied with 0.75m of 3 core cable, and mounting brackets. Three Warmair models are available offering heat outputs plus fan only setting: Warmair 3 - 3 kW, 2 kW, 1 kWWarmair 4.5 - 4.5 kW, 3 kW, 1.5 kWWarmair 6 - 6kW,4 kW, 2 kW ModelsWarm Air CurtainsModelStock Ref£Trade Warmair 3456343235.03 Warmair 4.5456344268.65 Warmair 6456345427.40 Remote SwitchRemote Switch unit to control Warmair units. Switch allows for fan only & three heat settings. ModelStock Ref£Trade VARSU43649458.00 Specification Rating Dimensions mm Weight Model kW W H D kg Warmair 3 3.0 650 103 210 6.1 Warmair 4.5 4.5 650 103 210 6.5 Warmair 6 6.0 900 103 210 8.7 220-240V-50Hz.BEAB Approved.

160 The Vent-Axia Convector Heater is ideal for use in any domestic or commercial room where extra or occasional heating is required. The heater is suitable for use in the home, offices, shops and workshops, but is not recommended for use in bathrooms. Both standard and timer versions offer three heat outputs; 0.75kW, 1.25kW & 2kW and are both thermostatically controlled. The Vent-Axia Convector Heater is lightweight, portable and is supplied with a cable and plug. Stylish and versatile, the heater may be wall mounted or installed as a floor standing unit using the feet included. This gives the benefit of moving the heater to an area where you want, when you want. For maximum safety the heater includes a thermal cut-out feature to prevent overheating. Timer Control The 24 Hour timer control offers On or Off setting selection in 15 minute time segments. Set the pins on the easy to use timer dial and the heater will operate automatically during the selected times. ModelConvector Heater ModelStock Ref£Trade VACH2-TC Standard42625052.75 VACH2T-TC Timer4746330.00 SpecificationRating Dimensions mm Weight Model kW W H D kgVACH2TC 2 530 370 110 2.3220-240V-50Hz. BEAB ApprovedConvector Heater •Silent operation •Ideal for use where occasional heating is required •Three heat outputs •Thermostatic control •Safety thermal cutout •BEAB Approval•Timer version available

161 The Vent-Axia Portable Fan Heater is a floor standing heater with three settings; fan only, 1kW and 2kW outputs. Variable thermostat. The unit comes complete with a 13amp plug. ModelPortable Fan Heater ModelStock Ref£Trade VAFH2TC42671537.87 Specification Rating Dimensions mm WeightModel kW W H D kg VAFH2TC 2 265 130 275 1.5 Portable Fan Heater •Silent operation •Ideal for use where occasional heating is required •Two heat settings •Thermostatic control •Safety thermal cutout •Fan only mode for summer cooling

CommercialRange Lo-Carbon T-SeriesThe UK’s No. 1 Commercial Fan is available with a low energy DC motor providing up to 65% energy saving. The motor is designed to provide longer life, improved performance, lower running costs and maintain the T-Series rugged reliability. Vent-Axia have improved the way this product can be purchased for the refurbishment market. As well as being able to purchase it as you always have, you can also purchase it as a fan core plus optional application specific fitting kit, which gives you more flexibility in both stocking and installing the product. It also supports our lo-carbon drive to reduce waste and landfill.

ACM100-200164-165 ACM250-315 166-167 Powerflow Range 168-169 Lo-Carbon T-SeriesOverview 170-171 Lo-Carbon T-SeriesWindow Fan 172--173 Lo-Carbon T-SeriesWall Fan 174-175 Lo-Carbon T-SeriesRoof Fan 176-177 Lo-Carbon T-SeriesPanel Fan 178-179 Traditional T-SeriesOverview 180-181 Traditional T-SeriesWindow Fan 182-183 Traditional T-SeriesWall Fan 184-185 Traditional T-SeriesRoof Fan 186-187 Traditional T-SeriesPanel/Ceiling Fan 188-189 Traditional T-SeriesDarkroom Fan 190-191 Traditional T-SeriesIn-line Fan 192-193 Super T-SeriesHeavy Duty Wall Fans 194-195 Standard RangeOverview 196-197 Standard RangeWindow Fan 198-199 Standard RangeRoof Fan 200-201 Standard RangeWall Fan 202-203 Standard RangePanel fan 204-205

164 Ducted Ventilation Vent Axia has designed a complete range of energy efficient Mixed Flow In-Line fans that are now quieter, offer two and half times the pressure of conventional axial fans and are dimensionally more compact making them ideal for many ducted applications. The ACM Mixed Flow In-Line fan can operate in both horizontal and vertical positions. MotorAll motors have three speeds selectable on installation and are fitted with Standard Thermal Overload Protection (S.T.O.P.). Designed for ambient temperatures up to +50°C. All sizes with capacitor run motors. All sizes are Class II appliances. Supply voltage 220-240V/1/50Hz. InstallationThese units have a separate footplate for simple location mounting and detachable spigots for simple connection to ducting. The motor body chassis rotates to provide connection in acute spaces. Cleaning the product has also become simple as all parts can be removed without removing the ducting. ControllerFor optimum variable speed performance use a Vent-Axia 1.5 Amp electronic controller. Surface mounted providing variable speed control with an On/Off/sensor slider with indication light. There is an adjustable minimum speed setting. The controller has electrical connections for use with suitable external sensors. Cannot be used with timer models.1.5 Amp Controller (Suitable for 100mm – 200mm models). Dimensions: 86 x 156 x 53mm (H x W x D). Stock Ref £TradeW300310101.53 For flush fitting, a metal wall box accessory is available. Stock Ref £Trade 40014412.27 Hole for wall box: 80 x 150 x 150mm (H x W x D). ModelsModelStock Ref£Trade ACM10017104010146.94 ACM100T17104020182.23 ACM12517105010183.13 ACM125T17105020183.13 ACM15017106010223.41 ACM150T17106020272.38 ACM20017108010328.64 ACM200T17108020400.66 Dimensions (mm) D G AØ B F H C E Size 100 125 150 200 AØ 97 122 147 199.5 B 178 178 200 223 C 124 124 138 146 D 298 259 350 300 E 96 96 118 130 F 168 168 192 195 G (fixing hole) 120 120 162 100 H (fixing hole) 153.5 153.5 178 180 ACM 100-200•Designed and manufactured in UK •Three speed motor •Timer versions available •Removable motor core assembly •Rotating motor chassis assembly •IP44 rated •Aesthetically pleasing with wipe clean polymer casing •Sound data from independent testing •Running speed selected on installation

165 Performance Guide St aticPressure P a Air Volume l/s Air Volume l/s Static Pressure Pa 0 25 50 75100 050100 150 200 250 300 175 150 125 100 75 50 25 0 250 200 150 100 50 0 7 2 4 3 5 6 8 1l/s @ Pa Dia. Motor Phase Speed r.p.m IP Rating Curve Ref. 0 50 100 150 200 Motor kW F.L.C Amps dBA @ 3m 100 1 Low 1580 IP44 1 70 50 10 0.02 0.09 16 100 1 High 2200 IP44 2 80 70 20 0.02 0.1 22 125 1 Low 1450 IP44 3 60 40 10 0.03 0.1 17 125 1 High 2400 IP44 4 90 80 60 0.02 0.12 24 150 1 Low 1645 IP44 5 130 90 60 0.04 0.17 29 150 1 High 2350 IP44 6 160 140 120 60 0.05 0.21 36 200 1 Low 1845 IP44 7 110 60 0.08 0.48 26 200 1 High 2350 IP44 8 290 260 240 210 170 0.11 0.55 41 Medium speed is not shown. Sound Data Dia. Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 100 Breakout High 32 36 41 39 37 37 28 22 22 100 Breakout Low 30 31 34 36 28 29 23 22 16 100 Inlet High 38 42 57 56 54 46 38 30 37 100 Inlet Low 35 40 49 49 47 37 28 24 30 100 Outlet High 36 41 52 52 53 44 37 28 34 100 Outlet Low 38 41 45 46 45 36 28 24 27 125 Breakout High 32 33 38 41 41 40 33 23 24 125 Breakout Low 27 33 30 39 30 29 24 22 17 125 Inlet High 36 47 53 58 55 53 47 39 39 125 Inlet Low 38 42 45 48 45 41 35 26 29 125 Outlet High 36 47 51 54 55 50 46 37 37 125 Outlet Low 33 41 45 45 44 38 33 25 26 150 Breakout High 26 28 41 45 48 54 41 29 36 150 Breakout Low 21 29 45 49 43 44 32 22 29 150 Inlet High 40 49 59 63 59 63 55 47 46 150 Inlet Low 38 46 52 57 52 54 46 37 38 150 Outlet High 36 48 54 60 58 61 54 46 44 150 Outlet Low 33 45 49 54 54 52 45 36 37 200 Breakout High 38 53 47 47 56 60 44 33 41 200 Breakout Low 26 46 40 34 30 26 18 21 26 200 Inlet High 46 52 54 60 61 63 60 49 47 200 Inlet Low 38 37 40 41 39 35 24 23 22 200 Outlet High 63 68 69 73 70 69 62 54 54 200 Outlet Low 53 54 52 52 48 47 39 28 33

166 ACM 250-315•Available in two sizes •Simple installation •Supplied complete for installation •Optimise fan performance by using an approvedVent-Axia controller •Diagonal impeller with stator •Galvanized metal housing •Integrated thermal switch •Includes a mounting bracket •Designed to meet IP54 Ducted Ventilation Vent Axia has designed a complete range of energy efficient Mixed Flow In-Line fans for use with rigid and flexible ducting.In-line Mixed Flow fans offer two and half times the pressure of conventional axial fans and are dimensionally more compact making them ideal for many ducted applications. The ACM Mixed Flow In-Line fan can operate in both horizontal and vertical positions and can be mounted to meet its optimum performance. Motor All motors are fitted with Standard Thermal Overload Protection (S.T.O.P.). Designed for ambient temperatures up to +50°C. All sizes with capacitor run motors. ACM 250 and 315 are Class I appliances. Supply voltage 220-240V/1/50Hz. ModelsGEN ModelStock Ref£Trade ACM25017110010484.00 ACM31517112010554.00 ACM 250 Controller For optimum performance use a Vent-Axia electronic controller. Surface mounted providing variable speed control with an On/Off/sensor slider with indication light. There is an adjustable minimum speed setting. The controller is radio suppressed to BS EN 55014 and electrical connections for use with suitable external sensors are provided.1.5 Amp Controller – Suitable for 250mm model Dimensions: 86 x 156 x 53mm (H x W x D).ModelStock Ref£Trade 1.5A Electronic ControllerW300310101.53 ACM315Controller Used in conjunction with speed controllable fans to provide 5 stepped speed without electronic motor ‘hum’. Several fans can be connected to one transformer provided their combined load does not exceed the controller rating. Single phase: 3.0amp. Rotary switch giving On/Off and five speeds. Output voltages at 240V/1PH/50Hz 0, 90, 115,140, 175, 240 volts. Neon indicator. Enclosures are protected to IP54. Dimensions: 135 x 170 x 117mm (H x W x D).ModelStock Ref£Trade 3A Transformer Controller10314103215.81

167 Dimensions (mm) 296 +- 2 258.8+ - 2 Ø250+ - 1 278 +- 1 ACM250 335.5 +- 2 31 8.5+ - 2 Ø 31 5 307.6 +- 2 ACM315 Performance Guide Air Volume l/s ACM250 - 315 Static Pressure Pa 400 300 200 100 0 0100 200 300 400 500 600 700 1 2l/s @ Pa Dia. Stock Ref. Poles r.p.m IP Rating Curve Ref. 0 100 200 300 400 S.C. Amps F.L.C Amps dBA @ 3m 250 17110010 2 2720 IP54 1 450 410 350 120 40 0.8 1 53 315 17112010 2 2840 IP54 2 650 610 540 460 150 1.2 1.6 56 Sound Data Dia. Spectrum 125 250 500 1k 2k 4k 8k dBA @ 3m 250 Inlet 34 54 61 65 67 66 55 72 250 Outlet 39 64 68 71 70 66 55 78 250 Casing 34 41 43 46 46 42 37 54 315 Inlet 45 60 66 68 69 67 56 75 315 Outlet 47 69 73 74 72 66 57 79 315 Casing 38 41 46 50 49 46 41 58

168 Ducted Ventilation Powerflow models provide a compact yet versatile range designed with the installer in mind, combining the acoustic benefits of a tough plastic casing with the pressure characteristics of a centrifugal fan. A range of seven models available from 100 to 315mm dia. duct sizes. The 315mm dia. model has been specifically developed for use with rigid ductwork. Air volumes from 59l/s to 340l/s in free air and capable of pressure development up to 500 Pa.Powerflow has 50-80mm long inlet and discharge spigots allowing easy installation and fixing. The adjustable mounting foot allows the terminal box to be rotated to any angle and allows plenty of space and adjustment for screw fixing. The robust fire retardant polymeric casing combined with internal guide vanes ensures optimum airflow management through the unit. Electrical Motors are 220-240V single phase 50Hz. Capacitor start and run. The terminal box is integral with the case moulding. All motors are fitted with Standard Thermal Overload Protection (S.T.O.P.). Motor/Impeller All models are fitted with an external rotor motor and backward curved impeller assembly for long life and reliability. All sizes are IP44 according to BS EN 60529. Ball bearings are greased for life and designed to run at any angle. Insulation is Class ‘B’ (from -30˚C to +40˚C). Manufacture is controlled to BS EN ISO 9001. Models 2 Pole In-Line Duct Fan - Single Phase.GEN Stock Ref £Trade ACP10012 238.28 ACP12512 257.01 ACP15012 266.83ACP16012266.83 ACP20012 364.08 ACP25012 471.32 ACP31512 548.76 2.5A Electronic ControllerIND On/Off indication light. Infinitely variable speed control. Adjustable minimum speed setting and optional sensor mode. The controller is radio-suppressed to BS800 and rated at 2.5 amps. ModelStock Ref£Trade 2.5A Electronic ControllerW10303102M98.23 Dimensions (mm) Dia AØ B C D E FØ G H Weight100 100 146 287 52 52 254 110 270 2.2 125 125 146 287 60 60 254 110 270 2.2 150 149 175 287 52 52 301 110 270 3.1 160 160 175 287 52 52 301 110 270 3.1 200 200 193 290 47 47 344 92 130 4.3 250 250 218 312 65 65 367 92 130 4.6 315 315 250 366 76 76 405 92 130 5.9 Sizes 100, 125, 150 & 160 have a flat mounting footPowerflow (ACP) •Tough plastic in-line range in seven models •50-80mm long ribbed spigots •Flame retardant casing •All models speed controllable •Fitted with Standard Thermal Overload Protection (S.T.O.P.) •For the best performance from your fan, use a Vent-Axia controller •IP44 Rated

169 Performance Guide 4 7l/s at Pa Dia. Motor Phase Stock Ref r.p.m IP Rating Curve Ref. 0 100 200 300 400 Motor kW S.C. Amps F.L.C Amps dBA @ 3m 100 1 ACP10012 2740 IP44 1 60 50 30 10 0.08 0.85 0.34 35 125 1 ACP12512 2410 IP44 2 80 60 40 10 0.08 0.85 0.34 35 150 1 ACP15012 2520 IP44 3 140 110 70 40 0.1 1.1 0.43 45 150 1 ACP16012 2520 IP44 4 140 110 70 40 0.1 1.1 0.43 45 200 1 ACP20012 2620 IP44 5 230 200 160 120 0.15 1.52 0.68 47 250 1 ACP25012 2720 IP44 6 290 260 220 180 120 0.19 1.6 0.77 48 315 1 ACP31512 2720 IP44 7 340 290 220 160 90 0.18 1.57 0.75 51 Sound Data Dia. Motor Phase Stock Ref. Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 100 1 ACP10012 Inlet 81 84 75 68 61 52 46 40 51 100 1 ACP10012 Outlet 82 84 77 68 61 52 49 43 52 100 1 ACP10012 Breakout 52 48 57 53 53 48 40 38 36 125 1 ACP12512 Inlet 80 79 76 70 61 57 51 45 51 125 1 ACP12512 Outlet 82 80 76 71 61 54 51 43 52 125 1 ACP12512 Breakout 52 48 57 53 53 48 40 38 36 150 1 ACP15012 Inlet 79 84 84 76 69 65 61 52 58 150 1 ACP15012 Outlet 78 84 83 74 69 65 60 50 57 150 1 ACP15012 Breakout 59 62 66 62 62 58 51 43 45 150 1 ACP16012 Inlet 81 81 79 76 66 61 58 49 55 150 1 ACP16012 Outlet 80 82 81 73 67 62 57 49 55 150 1 ACP16012 Breakout 59 62 66 62 62 58 51 43 45 200 1 ACP20012 Inlet 80 79 74 76 67 65 66 60 55 200 1 ACP20012 Outlet 79 79 74 71 69 69 65 59 55 200 1 ACP20012 Breakout 54 70 67 66 62 59 53 43 47 250 1 ACP25012 Inlet 84 80 74 74 69 69 67 63 56 250 1 ACP25012 Outlet 75 79 73 72 72 73 68 64 58 250 1 ACP25012 Breakout 60 71 70 66 65 62 55 44 49 315 1 ACP31512 Inlet 84 80 74 74 69 69 67 63 56 315 1 ACP31512 Outlet 75 79 73 72 72 73 68 64 58 315 1 ACP31512 Breakout 72 71 73 71 66 63 55 45 52

170 Lo-Carbon T-Series Range Overview •Wall, Window, Roof and panel mounting versions available •Low Energy DC Motor •Wired or Wireless control options •Up to 70% energy saving •Modular design, available as a complete unit or as aseparate fitting kit and fan core for refurbishment ErP Regulations The introduction of the ErP regulations gave us the opportunity to review our product ranges and has enabled us to improve the way we stock and sell them. You can still buy the market leading T-Series in the same way you always have, as a complete product, however we have taken the opportunity to add a more flexible option if you need it. We have introduced a modular option for refurbishment situations where you may not want to replace the whole product. For new build projects and complete building refits the market leading T-Series is unchanged and available as a complete unit generally supplied in one carton. For refurbishment markets, supplying it as separate core and specific fitting kit gives more flexibility in both stocking and installing the product. This also gives the lowest overall cost to refurbish your fan system without changing wiring or controls, furthermore it also supports our Lo-Carbon drive to reduce waste and landfill. Available as either Wired or Wireless control variants with controllers available, the Lo-Carbon T-series range offers the most flexible, efficient and controllable range of commercial fan systems. Complete Product option Complete product Modular option Fan Core Fitting Kit

171 Lo-Carbon T-Series Complete Fan ControllerType Window Wall Roof Panel Size Stock Ref Stock Ref Stock Ref Stock Ref Wired 9" 456165 456166 456168 456167 Wired 12" 456173 456174 456176 456175 Wireless 9" 456169 456170 456172 456171 Wireless 12" 456177 456178 456180 456179 Lo-Carbon T-Series Modular Option ControllerType Fitting Kit Options (excludes Fan Core) Fan Core Window Wall Roof Panel Size Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Wired 9" 472039 472047 472043 472055 472051 Wired 12" 472040 472048 472044 472056 472052 Wireless 9" 472041 472049 472045 472057 472053 Wireless 12" 472042 472050 472046 472058 472054 Wired or Wireless refers to the controller type that can be utilised with the particular model. Wired or Wireless refers to the controller type that can be utilised with the particular model.

172 UK’s No. 1 Commercial Fan The Lo-Carbon T-Series Fan range utilises a low energy DC motor, developed to improve performance, lower running costs and maintain T-Series’ rugged reliability.Window Fan The fitting kit is designed for installation through single or double glazing and material up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Alternatively, theLo-Carbon T-Series range can be used in conjunction with Vent-Axia ventilation accessories in flexible and rigid ducting systems to suit individual requirements. It can also be mounted in a fixing plate on walls or above ceilings. Instantaneous Shutter With energy saving in mind, units are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior grille. It operates on both extract and intake and at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum back draught protection. When the fan is used with the Lo-Carbon T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window. Top Socket A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.ModelsComplete FanModelStock Ref£Trade 9” Wired 456165489.70 12” Wired456173683.40 9” Wireless456169553.93 12” Wireless456177773.03 Fan Core (excludes Window Kit)ModelStock Ref£Trade 9" Wired472039488.01 12" Wired472040710.80 9" Wireless472041583.50 12" Wireless472042806.28 Window Kit (excludes Fan Core)ModelStock Ref£Trade 9" Wired47204763.86 12" Wired47204882.40 9" Wireless47204963.86 12" Wireless47205082.40 AccessoryExtended Fixing Rod setSizeStock Ref£Trade 9”56810411.53 12”56810616.79 ControllersModelsStock Ref£Trade Wireless 455874 125.57 Wired455873 104.68 Lo-Carbon T-Series Window Fan •Reduces your carbon footprint •Extract/intake model in 2 sizes: 9” and 12” •Long life Lo-Carbon motor lasts twice as long asconventional motors •Up to 70% energy saving •Wired or Wireless fan models available •Easy fit connector Top Socket, standard on all models

173 Dimensions (mm)Size Dim. 9 in 12 inA 39 41B 150 177C 304 381D 302 378E 19 19F 54 54Fixing hole Ø 260 337Weight kg 5.35 7.7 Complete product. Controller (W x H x D) 97 x 99 x 32 Performance Guide100 80 60 40 20 0 S taticPressure P a Air Volume m 3 /h 1 2 0 50010001500Extract performance m 3 /h (l/s) Watts Sound dB(A)AmpsModel Curve low medium high (high) (med) @ 3m @ 240VLo-Carbon 9" Window - Wireless/Wired 1 1 332 (90) 571 (160) 761 (210) 30.8 40 0.35Lo-Carbon 12" Window - Wireless/Wired 1 2 660 (185) 1295 (360) 1550 (430) 68.6 46 0.73

174 Lo-Carbon T-Series Wall Fan •Long life Lo-Carbon motor lasts twice as long as conventional motors •Reduces your carbon footprint •Extract/intake model in 2 sizes: 9” and 12” •Up to 70% energy saving •Wired or Wireless fan models available •Easy fit connector Top Socket, standard on all models UK’s No. 1 Commercial Fan The Lo-Carbon T-Series Fan range utilises a low energy DC motor, developed to improve performance, lower running costs and maintain T-Series’ rugged reliability.Wall Fan Lo-Carbon T-Series wall models are designed to fit directly into double brick, solid and cavity walls. The two part telescopic liner accommodates wall thicknesses from 240 to 315mm. For thicker walls additional liner sections are available. Lo-Carbon T-Series wall models are provided with internal and external wall frames which fit flush with both faces of the wall. Instantaneous Shutter Lo-Carbon T-Series models are supplied complete with an integral instantaneous automatic louvre shutter which will operate on both intake and extract and at any angle of mounting. When the fan is used with a Lo-Carbon T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window. Electrical Motor purpose-designed. Suitable for running at any angle. Quiet running. Suitable for operation in ambient temperatures from -40°C to +50°C. Fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.). Supply voltage 220-240V/1/50Hz.Top Socket A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.Models Complete FanSizeStock Ref£Trade 9” Wired456166620.12 12” Wired456174820.719” Wireless 456170701.41 12” Wireless 456178928.32Fan Core (excludes Wall Kit)SizeStock Ref£Trade 9" Wired472039488.01 12" Wired472040710.80 9" Wireless472041583.50 12" Wireless472042806.28 Wall Kit (excludes Fan Core)SizeStock Ref£Trade 9" Wired472043190.96 12" Wired472044201.57 9" Wireless472045190.96 12" Wireless472046201.57 AccessoryAdditional Wall Liner SectionSizeStock Ref£Trade 9”46009652.48 12”46008656.95 Controllers ModelsStock Ref£Trade Wireless455874 125.57 Wired455873 104.68

175 Dimensions (mm)Size Dim. 9 in 12 inA 391 470B 388 467C 365 442D 375 450 E 143 182 F 25 25Weight kg 7.77 10.86 Complete product. Controller (W x H x D) 97 x 99 x 32 Performance Guide70 60 50 40 30 20 10 0 S taticPressure P a 1 2 Air Volume m 3 /h 0 50010001500Extract performance m 3 /h (l/s) Watts Sound dB(A)AmpsModel Curve low medium high (high) (med) @ 3m @ 240VLo-Carbon 9" Wall - Wireless/Wired 1 1 326 (90) 562 (160) 732 (210) 27 39 0.31Lo-Carbon 12" Wall - Wireless/Wired 1 2 660 (185) 1355 (360) 1650 (430) 68 48 0.70

176 UK’s No. 1 Commercial Fan The Lo-Carbon T-Series Fan range utilises a low energy DC motor, developed to improve performance, lower running costs and maintain T-Series’ rugged reliability. Roof Fitting Kit Designing ventilation systems with the unit mounted in a skylight or a flat roof is easy. With a low profile cowl, the Lo-Carbon T-Series Roof model is suitable for installation in horizontal, angled (max pitch 30deg) and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs. Instantaneous Shutter With energy saving in mind, Lo-Carbon T-Series models are supplied complete with an integral, instantaneous, automatic louvre shutter concealed behind the interior grille.It will operate on both intake and extract and at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing.When the fan is used with a Lo-Carbon T-Series controller, the shutter can be set open with the fan motor switched off to provide natural ventilation without the security risk of an open window. Top Socket A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.Electrical Motor purpose-designed. Suitable for running at any angle. Quietrunning, enclosed. Suitable for operation in ambient temperatures from -40°C to +50°C. Fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.).Supply voltage 220-240V/1/50Hz.ModelsComplete FanModelStock Ref£Trade 9” Wired 456168553.61 12” Wired 456176768.28 9” Wireless 456172626.21 12” Wireless 456180869.06 Fan Core (excludes Roof Kit)SizeStock Ref£Trade 9" Wired472039488.01 12" Wired472040710.80 9" Wireless472041583.50 12" Wireless472042806.28 Roof Kit (excludes Fan Core) SizeStock Ref£Trade 9" Wired472055116.70 12" Wired47205682.40 9" Wireless47205763.86 12" Wireless472058137.92 Controllers ModelsStock Ref£Trade Wireless455874 125.57 Wired455873 104.68 Lo-Carbon T-Series Roof Fan •Reduces your carbon footprint •Extract / intake model in 2 sizes:9” and 12” •Long life Lo-Carbon motor lasts twice as long as otherconventional motors •Up to 70% energy saving •Wired or Wireless fan models available •Easy fit connector Top Socket, standard on all models

177 Dimensions (mm)Size Dim. 9 in 12 inA 136 171B 150 177C 304 381D 302 378 E 54 54 FØ 400 500 Fixing Hole 260 337Weight kg 6.22 9.28 Complete product. Controller (W x H x D) 97 x 99 x 32 Performance Graph 90 80 70 60 50 40 30 20 10 0 S tatic Pressure (P a) 0250 500 75010001250 1 2 Air Volume m 3 /h Extract performance m 3 /h (l/s) Watts Sound dB(A)AmpsModel Curve low medium high (high) (med) @ 3m @ 240VLo-Carbon 9" Roof - Wireless/Wired 1 1 313 (85) 562 (155) 693 (190) 27 40 0.34Lo-Carbon 12" Roof - Wireless/Wired 1 2 518 (143) 1017 (282) 1194 (330) 67 48 0.69

178 UK’s No. 1 Commercial Fan The Lo-Carbon T-Series Fan range utilises a low energy DC motor, developed to improve performance, lower running costs and maintain T-Series’ rugged reliability.Panel Fitting KitLo-Carbon T-Series panel/ceiling models are suitable for mounting at any angle in internal partitions, ceilings, ducts and, with louvre grilles, through external walls. When installed only the louvre grille is visible.Instantaneous Shutter With energy saving in mind, Lo-Carbon T-Series models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior grille. With a Lo-Carbon T-Series Controller the fan will operate on both extract and intake, suitable for any angle of mounting. When the fan is used with a Lo-Carbon T-Series controller, the shutter can be set open with the fan motor switched off to provide natural ventilation without the security risk of an open window. Wireless Control Every Lo-Carbon T-Series Wireless FM Controller uses unique digital signals to ensure trouble free operation. The controller will transmit through walls and floors allowing complete flexibility of design to control fans up to 30m away. Top Socket A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.Electrical Suitable for operation in ambient temperatures from -40°C to +50°C. Fitted with self resetting Standard Thermal Overload Protection (S.T.O.P).Supply voltage: 220-240V/1/50Hz.Easy Cleaning Integrated component design allows all parts to be dismantled for cleaning without the use ofspecialist tools. ModelsComplete FanSizeStock Ref£Trade 9” Wired456167 517.37 12” Wired456175712.77 9” Wireless456171 585.19 12” Wireless456179 806.20 Fan Core (excludes wired Panel Kit)SizeStock Ref£Trade 9" Wired472039488.01 12" Wired472040710.80 9" Wireless472041583.50 12" Wireless472042806.28 Panel Kit (excludes Fan Core)SizeStock Ref£Trade 9" Wired47205163.86 12" Wired472052137.92 9" Wireless472053116.70 12" Wireless47205482.40 ControllersModelsStock Ref£Trade Wireless455874 125.57 Wired455873 104.68 Lo-Carbon T-Series Panel Fan •Reduces your carbon footprint •Extract / intake model in 2 sizes: 9” and 12” •Long life Lo-Carbon motor last twice as long as otherconventional motors •Up to 70% energy saving •Wired or Wireless fan models available •Easy fit connector Top Socket, standard on all models

179 Dimensions (mm)Size 9 in 12 in Size 9 in 12 inA 391 470 J 345 422 B 388 467 K 19 19C 129 152 L 22 22D 39 41 M 180 180 E 302 378 N 309 386 F 304 381 O 326 402 GØ 255 334 P 126 164 HØ 247 325 Q 55 55Weight kg : 9mm - 5.13, 12mm - 7.44Complete product. Controller (W x H x D) 97 x 99 x 32 Performance Guide 100 80 60 40 20 0 S taticPressure P a 1 2 Air Volume m 3 /h 0 50010001500Extract performance m 3 /h (l/s) Watts Sound dB(A)AmpsModel Curve low medium high (high) (med) @ 3m @ 240VLo-Carbon 9" Panel - Wireless/Wired 1 1 357 (100) 601 (166) 799 (221) 30 41 0.33Lo-Carbon 12" Panel - Wireless/Wired 1 2 737 (205) 1487 (413) 1761 (490) 67 48 0.70

180 Traditional T-Series Range Overview •Available as wall, window, panel, roof, inline orDarkroom models•Available as a complete unit or modular fan core andfitting kit for refurbishments •Flexible installation design •Simple installation ErP Regulations The introduction of the ErP regulations gave us the opportunity to review our product ranges and has enabled us to improve the way we stock and sell them. You can still buy the market leading T-Series in the same way you always have, as a complete product, however we have taken the opportunity to add a more flexible option if you need it. We have introduced a modular option for refurbishment situations where you may not want to replace the whole product. For new build projects and complete building refits the market leading T-Series is unchanged and available as a complete unit generally supplied in one carton. For refurbishment markets,supplying as separate core and specific fitting kit gives more flexibility in both stocking and installing the product. This also gives the lowest overall cost to refurbish your fan system without changing wiring or controls, furthermore it also supports our Lo-Carbon drive to reduce waste and landfill. Complete product option Complete product Modular option Fan Core Fitting Kit

181 Traditional T-Series Complete Fan Window Wall Roof Panel Darkroom In-line Size Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref 6" W161110 W161510 W161210 W161610 W161240 W161710 7" W162110 W162510 W162210 W162610 W162240 N/A 9" W163110 W163510 W163210 W163610 W163240 W163710 12" W164110 W164510 W164210 W164610 W164240 W164710 Traditional T-Series Modular Option Fitting Kit Options (excludes Fan Core) Fan Core Window Wall Roof Panel Darkroom In-line Size Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref 6" 472012 472020 472016 472028 472024 472032 472036 7" 472013 472021 472017 472029 472025 472033 N/A 9" 472014 472022 472018 472030 472026 472034 472037 12" 472015 472023 472019 472031 472027 472035 472038

182 Traditional T-Series Window Fan •Extract/intake fans in 4 sizes: 6”, 7”, 9” and 12” •Patented electronic shutter system ensures quiet troublefree operation•To obtain the best from your fan, use the Ecotronic controller •Shutter open/fan off mode •Low sound levels •Easy fit connector Top Socket, standard on all models •Designed for single or double glazing up to 32mm thick UK’s No. 1 Commercial Fan The T-Series fan range is fitted with a Vent-Axia M-Tech motor, developed to improve performance, lower running costs and maintain the T-Series’ rugged reliability. A patented speed control pack is simply plugged in one of 3 positions to provide low, medium or boost speed matching the fan performance to the requirements of the installation. Instantaneous Shutter With energy saving in mind T-Series Fitting Kits are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior grille. It operates on both extract and intake and at any angle of mounting. When the fan is used with a T-Series or Ecotronic controller, the shutter can be set open with the fan motor switched off to provide natural ventilation without the security risk of an open window. Top Socket A connector Top Socket is standard on all T-Series fans allowing fast and trouble-free mains connection.Easy Cleaning Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools.Electrical Motor purpose-designed. Suitable for running at any angle. Quiet running. Suitable for operation in ambient temperatures from -40°C to +50°C. Fitted with Standard Thermal Overload Protection (S.T.O.P.). Supply voltage 220-240V/1/50Hz. Window Kit Designed for use in single or double glazing, most types of glass and materials up to 32mm thick. Greater thicknesses can be accommodated using Extended Fixing Rod Sets. Can also be mounted in a fixing plate or wall, in ducts or above ceilings.Models Complete FanModelStock Ref£Trade TX6WWW161110 286.37 TX7WWW162110 376.59 TX9WWW163110489.70 TX12WWW164110 683.40 Fan Core (excludes Fitting Kit)SizeStock Ref£Trade TX6472012302.36 TX7472013381.92 TX9472014488.01 TX12472015710.80 Window Kits (excludes Fan Core)SizeStock Ref£Trade TX647202037.08 TX747202151.50 TX947202263.86 TX1247202382.40 Accessories Extended Fitting Rod setSizeStock Ref£Trade 6/7/9”56810411.53 12”56810616.79

183 Controllers Ecotronic Controller Surface MountingStock Ref £Trade W362320 148.46 T-Series Controller Surface MountingStock Ref £Trade W361119108.31 Dimensions (mm)Size Dim. 6 in 7 in 9 in 12 inA 31 31 39 41B 130 130 150 177C 226 265 304 381D 220 258 302 378E 19 19 19 19F 54 54 54 54Fixing hole Ø 184 222 260 337Weight kg 3.57 3.93 5.35 7.7 Complete product. Performance Guide Extract performance m 3 /h (l/s) Watts Sound dB(A)AmpsModel low medium high (high) (med) @ 3m @ 240V TX6 Window 245 (68) 315 (88) 360 (100) 30 41 0.24 TX7 Window 305 (85) 395 (110) 485 (135) 40 37 0.24 TX9 Window465 (130) 685 (190) 795 (220) 85 43 0.42 TX12 Window 1095 (305) 1415 (393) 1615 (449) 105 48 0.51

184 Traditional T-Series Wall Fan •Extract/intake model in 4 sizes:6”, 7”, 9” and 12” •Patented electronic shutter system ensures quiet,trouble free operation•For the very best from your fan use theEcotronic controller •Easy fit connector Top Socket, standard onall models UK’s No. 1 Commercial Fan Behind the grille of the Vent-Axia T-Series Wall model is a range of high performance extract/intake fans designed to fit through most wall thicknesses using telescopic liners supplied.T-Series also features a unique speed control pack which enables high, medium or low speed to be preset to suit room size or required duty.T-Series controllers may be used with this model to obtain a choice of speeds, reversible airflow direction and automatic sensor operation. The Vent-Axia Ecotronic controller gives even greater running economy with its minimum speed setting and ‘E’ mode.Top Socket A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.Shutter TX models are supplied complete with an integral instantaneous automatic louvre shutter which will operate on both intake and extract and at any angle of mounting. When the fan is used with a T-Series or Ecotronic controller, the shutter can be set open with the fan motor switched off to provide natural ventilation without the security risk of an open window. Electrical Motor purpose-designed. Suitable for running at any angle. Quiet running, enclosed. Suitable for operation in ambient temperatures from -40°C to +50°C. Fitted with Standard Thermal Overload Protection (S.T.O.P.). Supply voltage 220-240V/1/50Hz. Wall Kits Designed to fit into most double brick walls using the telescopic liners, supplied. Additional liners are available to accommodate exceptionally thick brick walls.ModelsComplete FanModelStock Ref£Trade TX6WLW161510 362.13 TX7WLW162510 513.05 TX9WLW163510 620.12 TX12WLW164510 820.71 Fan Core (excludes Fitting Kit)SizeStock Ref£Trade TX6472012302.36 TX7472013381.92 TX9472014488.01 TX12472015710.80 Wall Kits (excludes Fan Core)SizeStock Ref£Trade TX6472016100.79 TX7472017169.74 TX9472018190.96 TX12472019201.57 Accessories Additional Wall Liner Section SP SizeStock Ref£Trade TX646009438.56 TX746009544.71 TX946009652.48 TX1246008656.95

185 Controllers Ecotronic Controller Surface MountingStock Ref £Trade W362320 148.46 T-Series Controller Surface MountingStock Ref £Trade W361119108.31 Dimensions (mm)Size Dim. 6 in 7 in 9 in 12 inA 310 352 391 470B 303 345 388 467C 290 330 365 442D 290 330 375 450 E 104 124 143 182 F 25 25 25 25Weight kg 5.54 6.13 7.77 10.86 Complete product. Performance Guide Extract performance m 3 /h (l/s) Watts Sound dB(A)AmpsModel low medium high (high) (med) @ 3m @ 240V TX6 Wall 270 (75) 350 (97) 395 (110) 40 43 0.24 TX7 Wall 335 (93) 435 (120) 530 (147) 40 39 0.24 TX9 Wall515 (143) 755 (210) 870 (241) 85 43 0.42 TX12 Wall 1185 (329) 1530 (425) 1745 (485) 105 49 0.51

186 Traditional T-Series Roof Fan •Extract/intake model in 4 sizes:6”, 7”, 9” and 12” •Patented electronic shutter system ensures quiet, troublefree operation •For the very best from your fan use the Ecotronic controller •T-Series controllers and sensors save energy by onlyswitching on the units when you want either manuallyor automatically •Easy fit connector Top Socket, standard on all models UK’s No. 1 Commercial Fan With a low profile cowl, the T-Series Roof model is suitable for installation in horizontal, angled (max pitch 30deg) and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single or double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. All four sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs. T-Series features a unique speed control pack which enables high, medium or low speed to be preset to suit room size or required duty. When used with a T-Series TSC controller, the speed control pack is removed from the T-Series fan and fitted into the 3-pin socket in the back of the controller. The Vent-Axia Ecotronic controller gives even greater running economy with its minimum speed setting and ‘E’ mode. When using the Ecotronic controller the speed control pack remains in the fan. Shutter With energy saving in mind, T-Series Fitting Kits are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior grille. It will operate on both intake and extract and at any angle of mounting. When the fan is used with a T-Series or Ecotronic controller, the shutter can be set open with the fan motor switched off to provide natural ventilation without the security risk of an open window. Electrical Motor purpose-designed. Suitable for running at any angle. Quiet running, enclosed. Suitable for operation in ambient temperatures from -40°C to +50°C. Fitted with Standard Thermal Overload Protection (S.T.O.P.).Supply voltage 220-240V/1/50 Hz. Top Socket A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.ModelsComplete FanModelStock Ref£Trade TX6RFW161210 316.08 TX7RFW162210439.70 TX9RFW163210553.61 TX12RFW164210768.28 Fan Core (excludes Fitting Kit)SizeStock Ref£Trade TX6472012302.36 TX7472013381.92 TX9472014488.01 TX12472015710.80 Roof Kit (excludes Fan Core)SizeStock Ref£Trade TX647202853.05 TX747202984.87 TX9472030116.70 TX12472031137.92 Controllers Ecotronic Controller Surface MountingStock Ref £Trade W362320 148.46 T-Series Controller Surface MountingStock Ref £Trade W361119108.31

187 Dimensions (mm)Size Dim. 6 in 7 in 9 in 12 inA 100 136 136 171B 130 130 150 177C 226 265 304 381D 220 258 302 378 E 54 54 54 54 F Ø 285 400 400 500 Fixing Hole Ø 184 222 260 337Weight kg 3.96 4.89 6.22 9.28 Complete product. Performance Extract performance m 3 /h (l/s) Watts Sound dB(A)AmpsModel low medium high (high) (med) @ 3m @ 240V TX6 Roof 195 (55) 250 (70) 290 (80) 30 41 0.24 TX7 Roof 305 (85) 395 (110) 485 (135) 40 37 0.24 TX9 Roof465 (130) 685 (190) 795 (220) 85 43 0.42 TX12 Roof 1010 (280) 1305 (362) 1485 (412) 105 48 0.51

188 Traditional T-Series Panel/Ceiling Fan •Extract/intake model in 4 sizes:6”, 7”, 9” and 12” •Colour: soft tone grey •Patented electronic shutter system ensures quiettrouble-free operation •For the very best from your fan use the Ecotronic controller •East fit connector Top Socket, standard on all models UK’s No. 1 Commercial Fan Vent-Axia T-Series Panel/Ceiling models are suitable for mounting at any angle in internal partitions, ceilings, ducts and, with louvre grilles, through external walls. When installed only the louvre grille is visible. The range features a unique speed control pack which enables high, medium or low speed to be preset to suit a specific room size or required duty. T-Series controllers may be used with this model to obtain a choice of speeds, reversible airflow direction and automatic sensor operation. When used with a controller, the speed control pack is removed from the T-Series fan and fitted into the 3-pin socket in the back of the controller. The Vent-Axia Ecotronic controller gives even greater running economy with its minimum speed setting on ‘E’ mode and infinitely variable speed control. For this controller the speed control pack remains in the fan. Electrical Suitable for operation in ambient temperatures from -40°C to +50°C. Fitted with Standard Thermal Overload Protection (S.T.O.P).Supply voltage: 220-240V/1/50Hz.Top Socket A connector Top Socket is standard on all T-Series fans allowing fast and trouble-free mains connection.Shutter With energy saving in mind, panel/ceiling kits are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior grille. It will operate on both intake and extract and at any angle of mounting. When the fan is used with a T-Series or Ecotronic controller, the shutter can be set open with the fan motor switched off to provide natural ventilation without the security risk of an open window. ModelsComplete FanModelStock Ref£Trade TX6PLW161610313.73 TX7PLW162610403.25 TX9PLW163610517.37 TX12PLW164610712.77 Fan Core (excludes Fitting Kit)SizeStock Ref£Trade TX6472012302.36 TX7472013381.92 TX9472014488.01 TX12472015710.80 Panel/Ceiling Kit (excludes Fan Core)SizeStock Ref£Trade TX647202437.08 TX747202551.50 TX947202663.86 TX1247202782.40 Controllers EcotronicController Surface Mounting Stock Ref £Trade W362320 148.46 T-Series Controller Surface MountingStock Ref £Trade W361119108.31

189 Dimensions (mm)Size Dim. 6 in 7 in 9 in 12 inA 310 352 391 470 B 303 345 388 467C 117 117 129 152D 32 32 39 41 E 220 258 302 378 F 226 265 304 381 GØ 180 218 255 334 HØ 171 210 247 325 J 267 306 345 422 K 19 19 19 19 L 22 22 22 22 M 180 180 180 180 N 231 270 309 386 O 244 282 326 402 P 85 104 126 164 Q 55 55 55 55 R 12 12 12 12Weight kg 3.50 3.82 5.13 7.44 Complete product. Performance Guide Extract performance m 3 /h (l/s) Watts Sound dB(A)AmpsModel low medium high (high) (med) @ 3m @ 240V TX6 Panel/Ceiling 295 (81) 380 (105) 435 (120) 30 41 0.24 TX7 Panel/Ceiling 365 (101) 480 (133) 585 (162) 40 37 0.24 TX9 Panel/Ceiling565 (157) 830 (230) 960 (267) 85 43 0.42 TX12 Panel/Ceiling 1270 (353) 1640 (456) 1885 (524) 105 44 0.51

190 UK’s No. 1 Commercial Fan A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom fitting kit has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles.Shutter With energy savings in mind Darkroom models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angleof mounting. When used with a T-Series or Ecotronic controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window. Top Socket A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.Electrical Suitable for running at any angle. Quiet running, enclosed. Fitted with Standard Thermal Overload Protection (S.T.O.P.).Supply voltage: 220-240V/1/50Hz. Suitable for operation in ambient temperatures from -40°C to +50°C. Models Complete FanModelStock Ref£Trade TX6DRW161240354.55 TX7DRW162240505.05 TX9DRW163240 591.84 TX12DRW164240810.82Fan Core (excludes Fitting Kit)SizeStock Ref£Trade TX6472012302.36 TX7472013381.92 TX9472014488.01 TX12472015710.80 Darkroom Kit (excludes Fan Core)SizeStock Ref£Trade TX647203284.87 TX7472033170.36 TX9472034190.96 TX12472035212.18 Controllers Ecotronic Controller Surface MountingStock Ref £Trade W362320 148.46 T-Series Controller Surface MountingStock Ref £Trade W361119108.31 Traditional T-Series Darkroom Fan •Extract/intake models in 4 sizes:6”, 7”, 9” and 12” •Specially designed to provide extract/intake ventilationin darkrooms, X-ray areas, etc •Patented electronic shutter system ensures quiet, troublefree operation •For the very best from your fan use the Ecotronic controller •Integrated component design allows all parts to bedismantled for cleaning without the use of specialist tools •Easy fit connector Top Socket, standard on all models

191 Dimensions (mm)Size Dim. 6 in 7 in 9 in 12 inA 100 136 136 171B 196 206 229 308C 285 400 400 500D 220 258 302 378 E 226 265 304 381 F 19 19 19 19 Fixing Hole Ø 184 222 260 337Weight kg 4.13 5.33 6.60 10.05 Complete product. Performance Guide Extract performance m 3 /h (l/s) Watts Sound dB(A)AmpsModel low medium high (high) (med) @ 3m @ 240V TX6 Darkroom 200 (55) 240 (67) 265 (74) 30 43 0.24 TX7 Darkroom 330 (92) 415 (115) 530 (147) 40 42 0.24 TX9 Darkroom455 (126) 630 (175) 725 (201) 85 45 0.42 TX12 Darkroom 870 (242) 1040 (289) 1130 (314) 100 42 0.51

192 Traditional T-Series In-Line Fan •Extract/intake model in 3 sizes: 6”, 9” and 12” •Patented instantaneous electronic shutter system ensuresquiet, trouble free operation •For the best from your fan use the Ecotronic controller •T-Series controllers and sensor save energy by onlyswitching on the units when you want eithermanually or automatically •Easy fit connector Top Socket, standard on all models UK’s No. 1 Commercial Fan No other range of high performance in-line duct fans offers a combination of 3 impeller diameters, reversibility, low sound level, speed control and built-in electric shutter. T-Series features a unique speed control pack which enables high, medium or low speed to be preset to suit room size or required duty. Designed for use with rigid or flexible ducting, T-Series In-Line models can be plate mounted or fixed through partitions and in ceiling voids. T-Series controllers may be used with this model to obtain a choice of speeds, extract/intake airflow direction and automatic sensor operation. The Vent-Axia Ecotronic controller gives even greater running economy with its minimum speed setting and ‘E’ mode. Top Socket A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.Shutter The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum back draught protection.When the fan is used with a T-Series or Ecotronic controller, the shutter can be set open with the fan motor switched off to provide natural ventilation without the security risk of an open window. Ducts Where ducts pass through an unheated roof void, the duct should be insulated. Horizontal ducts should fall away from the fan unit. In circumstances where an excessive amount of moisture is present, a condensation trap should be installed in the exhaust duct. The fan unit should be accessible for regular maintenance. Electrical Suitable for operation in ambient temperatures from -40°C to +50°C. Fitted with Standard Thermal Overload Protection (S.T.O.P.). Supply voltage 220-240V/1/50 Hz. Models Complete FanModelStock Ref£Trade TX6ILW161710324.95 TX9ILW163710 592.91 TX12ILW164710788.89 Fan Core (excludes Fitting Kit)ModelStock Ref£Trade TX6472012302.36 TX9472014488.01 TX12472015710.80 In-line Kit (excludes Fan Core)ModelStock Ref£Trade TX647203663.65 TX9472037180.66 TX12472038201.88 For use with rigid and flexible ducting. Can be plate-mounted or fixed to partitions and in ceiling voids. Controllers Ecotronic Controller Surface MountingStock Ref £Trade W362320 148.46 T-Series Controller Surface MountingStock Ref £Trade W361119108.31

193 Dimensions (mm) Sizes 6 & 9 Size 12Size Dim. 6 in 9 in 12 inA 75 71 200B 175 183 337C 45 41 45DØ 175 300 400 E 220 302 378 F 226 304 381 Fixing Hole Ø 184 260 337 kg 4.5 8 11.5 Performance GuideExtract performance m 3 /h (l/s) Watts Sound dB(A)AmpsModel low medium high (high) (med) @ 3m @ 240V TX6 In-line 318 (88) 398 (110) 444 (123) 30 45 0.24 TX9 In-line703 (195) 966 (268) 1050 (292) 85 47 0.42 TX12" In-line 1674 (465) 2000 (556) 2230 (620) 100 51 0.51

194 Powerful Ventilation Vent-Axia’s Super T-Series 355, 400, 450 and 500mm fans provide efficient, quiet powerful ventilation with performances up to 4940m 3 /h.Tough heavy duty internal grilles and external weather shutters ensure longevity, performance and peace of mind. Construction The axial fan at the heart of the Super T range is based on an integrated impeller and internal rotor motor design which produces a very compact unit. A specially designed bellmouth inlet and mounting plate ensures an excellent performance to sound level ratio.Electrical Single phase 220-240V 50Hz. Capacitor start and run. An IP54 terminal box is supplied with all models with conduit entry from the side of the wall liner. All motors are fitted with Standard Thermal Overload Protection (S.T.O.P.), which should be wired via the controller.ModelsSuper T - Gravity shutter When installed, only the room side aluminium fascia grille is visible. The outside is finished with an external gravity shutter and frame.ModelStock Ref£Trade ST355-16-WL165510 940.00 ST400-16-WL166510 1030.52 ST450-16-WL167510 1205.73 ST500-16-WL168510 1352.71 Super T TX - Electric shutter Super T TX extract or intake models with powerful, quiet, smooth-operation electric shutters. ModelStock Ref£Trade STX355165710 1210.98 STX400166710 1301.22 STX4501677101477.09 STX500168710 1623.67 Super T Filtered Air InputSuper T ARX and AR filtered passive air replacement input unit. Consisting of a wall liner with high capacity high disposable EU4 pleated filter which fits inside the wall liner. ARX ModelsWith electronically controlled integral shutter AR Models - external louvre fixed blade.ModelStock Ref£Trade Units with integral shutterSTARX355165810 977.68 STARX4501678101120.80Units with louvre fixed bladesSTAR355165910 431.98 STAR450167910520.78Filtered Kitchen Extract - Super T GF Super T GF extract unit without internal grille, but with matching stainless steel filter housing and tray kit ready for assembly on site and 50mm stainless steel framed mesh grease filter with handles.ModelStock Ref£Trade STGF3551656201289.91 STGF400166620 1415.08 Accessories Replacement Grease Filters Super T replacement grease filters 50mm stainless steel mesh filter with handles. Supplied in packs of two.ModelStock Ref£Trade 355452550 266.63 400452551 352.72 Super T-Series •4 impeller diameters 355, 400, 450, 500mm •Complete with telescopic wall sleeve and shutter, ready for installation •IP54 motor and terminal box •Smart internal grille and external shutter with flange trim •Super quiet operation •For the very best performance from your fan, use the Vent-Axia 25Amp electronic controller

195 Dimensions (mm) Impeller dia. 355 400 450 500 A 550 597 657 727 B 550 597 657 727 C 470 520 580 650 D 470 520 580 650 Weight kg 17 22 28 33 Performance Guide Model Extract Performance m 3 /h(l/s) F.I.D. Watts S.C. amps F.L.C. amps Sound dB(A) @ 3m 355-16 1800 (500) 130 1.38 0.6 40 400-16 2034 (565) 90 1.2 0.46 45 450-16 2561 (761) 100 1.4 0.48 48 500-16 4378 (1216) 360 3.6 1.6 51 355-14 2150 (597) 150 1.38 0.7 56 400-14 3500 (972) 190 1.45 0.84 59 Replacement Air Filters High capacity EU4 pleated filter which fits inside wall liner. Supplied in packs of five.ModelStock Ref£Trade 355452814 143.83 450452815 183.22Electronic 2.5A Controller Provides variable motor speed control. On/Off with indication light. Infinitely variable speed slider control. Presettable minimum speed and sensor mode option: can be connected to a range of Vent-Axia sensors. Radio suppressed to BS 800. Includes electric shutter output.Stock Ref £Trade W10303102M 98.23

196 Traditional Standard Range Overview •Retro styled product •Available as a fan core and fitting kit for refurbishment ErP Regulations The introduction of the ErP regulations has given us the opportunity to review our product ranges and has enabled us to improve the way we stock and sell them. You can still buy the Standard Range in the same way you always have, as a complete product, however we have taken the opportunity to add a more flexible option if you need it. We have introduced a modular option for refurbishment situations where you may not want to replace the whole product. The Standard Range can also be supplied as a Fan Core or specific fitting kit, this gives you more flexibility in both stocking and installing the product. It also supports our Lo-Carbon drive to reduce waste and landfill.There are two variants of Core assembly, the Window/Roof Core and the Panel / Wall Core. The Window / Roof core are the circular fitting assemblies and consists of all internal components. The fitting kit consists of the externally mounted components (eg cowl or grill). The Wall and Panel core assemblies are square and contains the wiring loom for connecting to the relevant fixing kit (if required). The Wall fitting kit consists of the external grill and the wall mounting sleeve.The panel fan has no separate fixing kit. Modular option Fan Core Fitting Kit Complete product option Complete Product

197 Traditional Standard Window & Roof Range WindowComplete Fan RoofComplete Fan Window/RoofFan Core Fitting Kit Options (excludes Fan Core) Window Roof Size Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref 6"131310131410 472226 472230 472234 7"132310132410 472227 472231 472235 9"133310133410 472228 472232 472236 12" 134310 134410 472229 472233 472237 Traditional Standard Wall & Panel Range Wall Fan Complete Fan Wall Fan Core Wall Fitting Kit (excludes Fan Core) Panel Fan Complete Size Stock Ref Stock Ref Stock Ref Size Stock Ref 6"131510 472222 472274 6" 472442 7"132510 472223 472275 7" 472443 9"133510 472224 472276 9" 472444 12"134510 472225 472277 12" 472445

198 Traditional Standard Window Fan •Extract / intake model in 4 sizes:6", 7", 9" and 12" •IPX4 Rated •Colour: White •Manufactured in weather-resistant polymeric materials •For the best performance from your fan, use anEcotronic controller •Suitable for glass or panels up to 10mm thick Classic Retro-Style Ventilation This ever popular range of extract/intake fans continues to satisfy the most demanding requirements for efficient ventilation. The Vent-Axia Standard Range fitting kit unit is supplied without a shutter. The shutter is available as an accessory, which can be easily fitted within the unit. Standard Range Window Fans and Fitting Kits are suitable for most forms of single glazing or can be wall mounted in a Vent-Axia fixing plate. Vent-Axia’s patented spigot and ring method of fixing ensures easy installation and a weather proof joint. The simple integrated component design makes installation and servicing easy.Fan Core Motor Purpose designed enclosed motor. Suitable for running at any angle. Quiet running. Supply voltage 220-240V/1/50 Hz. Suitable for operation in ambient temperatures from -40° to +50°C. Fitted with Standard Thermal Overload Protection (S.T.O.P.). Shutter Type SD/R The extract/intake shutter fits inside the Vent-Axia unit and closes against unwanted back draughts. It can be fitted at the same time as the unit or at a later date if required. Airflow operated for extract use, cord operated lock for intake use. For all models mounted in vertical surfaces only. Controller The Ecotronic controller is recommended for use with this model to provide full function control of the fan plus the option of sensor mode using a selection of electro-mechanical switches to provide automatic switching of the fan.Alternatively, single speed extract is achieved using a normal On/Off switch. Easy Cleaning Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools. Protective Grilles Where Standard Range units are installed in low positions, finger guards provide extra protection to VDE, DIN 31001.ModelsComplete FanSizeStock Ref£Trade S6WW131310 299.57 S7WW132310 390.72 S9WW133310 512.27 S12WW134310720.10 Fan Core (excludes Window Kit)SizeStock Ref £Trade 6"472226 269.61 7"472227 351.65 9"472228 461.04 12"472229648.09 Window Kit (excludes Fan Core)SizeStock Ref £Trade 6"472230 29.96 7"472231 39.07 9"472232 51.23 12"47223372.01

199 Accessories ShuttersSizeStock Ref£Trade S6SD/R231710 74.13 S7SD/R232710 92.09 S9SD/R233710118.86 S12SD/R234710 159.19Fan & Fitting Kit Dimensions (mm) Size 6 in 7 in 9 in 12 in A 140 147 166 201 B Ø 216 254 295 381 C 21 21 21 21 D 83 83 92 105 E (max) 10 10 10 13 Fixing hole Ø 184 222 260 337 Weight kg 2.9 3.2 4.6 7.0 Fan Core and Fitting Kit combined weight PerformanceModel Extract Performance m 3 /h (l/s) F.I.D. Watts MAX. Sound dB(A) @ 3m Amps @ 240VS6WW 285 (79) 32 35 0.16 S7WW 425 (118) 34 31 0.16 S9WW 710 (197) 53 39 0.24 S12WW 1560 (433)84 42 0.36

200 Classic Retro-Styled Ventilation A versatile and robust range of roof extract fans designed to satisfy the requirements of efficient ventilation in commercial and industrial applications. The simple, proven design of Standard Range makes installation and routine cleaning easy.Featuring a low profile cowl, the unit is ready for fitting into horizontal, angled and vertical glass, fixing plates on roofs and in vertical windows or walls in exposed areas. With Vent-Axia roof plate assemblies, all four sizes can be fitted easily into flat roofs. Suitable for roof installation plus window and wall installation in exposed areas eg: coastal positions. Vent-Axia’s spigot and ring method of fixing ensures easy installation and a weather proof joint. We recommend the use of sealing compound under the upper part of the unit when fitted in roofs. Fan Core Motor Purpose designed enclosed motor. Suitable for running at any angle. Quiet running, continuous rated motor with sealed for life ball bearings. Suitable for operation in ambient temperatures from -40°C to +50°C. Fitted with Standard Thermal Overload Protection (S.T.O.P.). Supply voltage 220-240V/1/50Hz. All Standard Range roof models are designed to fit directly into horizontal and sloping windows including wired cast, up to 10mm thick. In solid roofs, install using a roof plate assembly and, if required, an eggcrate grille in the ceiling below. A suitable sealing compound should be used between the glass/roof plate and theexterior seal. ModelsComplete FanSizeStock Ref£ Trade S6RF131410333.79 S7RF132410474.72 S9RF133410584.75 S12RF134410828.42 Fan Core (excludes Roof Kit)SizeStock Ref £Trade 6"472226 269.61 7"472227 351.65 9"472228 461.04 12"472229648.09 Roof Kit (excludes Fan Core)SizeStock Ref £Trade 6"472234 64.18 7"472235123.07 9"472236 123.71 12"472237180.30 Traditional Standard Roof Fan •Extract model in 4 sizes:6", 7", 9" and 12" •IPX4 Rated •Colour: White •Wide range of sensors available •Manufactured in weather-resistant polymeric materials •For the best performance from your fan, use an Ecotroniccontroller

201 Fan & Fitting Kit Dimensions (mm) Size 6 in 7 in 9 in 12 in A 140 147 166 201 B Ø 216 254 295 381 C 21 21 21 21 D 95 108 121 146 E Ø 267 330 394 508 Fixing hole Ø 184 222 260 337 Weight kg 3.2 3.9 5.5 8.5 Fan Core and Fitting Kit combined weight PerformanceModel Extract Performance m 3 /h (l/s) F.I.D. Watts MAX. Sound dB(A) @ 3m Amps @ 240VS6RF 240 (67) 32 36 0.16 S7RF 350 (97) 34 31 0.16 S9RF 625 (174) 53 39 0.24 S12RF 1130 (314) 84 42 0.36

202 Traditional Standard Wall Fan •Extract/intake models in 4 sizes: 6", 7", 9" and 12" •IPX4 Rated •White fascia, wall sleeve and black external weather louvre •Optional shutter available •Manufactured in weather-resistant polymeric materials•For the best performance from your fan, use anEcotronic controller Classic Retro-Styled Ventilation The proven Standard Range Wall Fans and Fitting Kits are designed to fit flush into most double brick walls using the rigid wall liner supplied. Provision is made within the liner for conduit entry. When installed, only the ivory fascia is visible on the internal wall face. The external weather louvre fits flush to the outside. A shutter is available as an accessory which can be easily fitted within the unit. On new building work the installation and wiring of the wall liner can be completed prior to the final installation of the unit and controller. Fully shrouded connectors on the fascia automatically connect the wiring to the motor when fitted to the wall liner. Fan Core Motor The motor is purpose-designed. Suitable for running at any angle. Quiet running, enclosed, sealed for life ball bearings. Supply voltage: 220-240V/1/50Hz. Suitable for operation in ambient temperatures from -40°C to +50°C.Fitted with Standard Thermal Overload Protection (S.T.O.P.). Shutter Type SD/RThe extract/intake shutter fits inside the Vent-Axia unit and closes against unwanted back draughts. It can be fitted at the same time as the unit or at a later date if required. Airflow operated for extract use, cord operated lock for intake use.Controller The Ecotronic controller is recommended for use with this model to give full function control of the fan including auto mode using an electro-mechanical sensor from Vent-Axia’s sensor range. Alternatively, single speed extract is achieved using a normal On/Off switch. ModelsComplete FanSizeStock Ref£ Trade S6WL131510400.41 S7WL132510543.05 S9WL133510685.83 S12WL134510899.86 Fan Core (excludes Wall Kit)SizeStock Ref £Trade 6"472222 342.23 7"472223 429.10 9"472224 547.78 12"472225747.02 Wall Kit (excludes Fan Core)SizeStock Ref £Trade 6"472274 63.37 7"472275116.52 9"472276 137.06 12"472277145.88 Accessories ShuttersSizeStock Ref£Trade S6SD/R231710 74.13 S7SD/R232710 92.09 S9SD/R233710118.86 S12SD/R234710 159.19

203 Fitting Kit Dimensions (mm) C A B C Size 6 in 7 in 9 in 12 in A 279 279 279 279 B 203 279 279 356 C 279 362 362 448 Fixing hole Ø 235 311 311 400 Weight kg 4.1 5.7 6.7 10.1 Fan Core and Fitting Kit combined weight PerformanceModel Extract Performance m 3 /h (l/s) F.I.D. Watts MAX. Sound dB(A) @ 3m Amps @ 240VS6WL 340 (94) 32 39 0.16 S7WL 544 (151) 34 35 0.16 S9WL 856 (238) 53 43 0.24 S12WL 1767 (491) 84 46 0.36 Please note that the Standard Range Panel model is not suitable for fitting within an existing Standard Range Wall fitting kit. Please use the correct Standard range Wall Core assembly.

204 Classic Retro-Styled Ventilation A versatile range of extract/intake fans designed to satisfy the most demanding requirements of efficient ventilation. Available in four sizes, the Standard Range Panel Fan is supplied without a shutter for vertical installations. The shutter is available as an accessory which can be easily fitted within the unit. Suitable for mounting at any angle, this range may be installed in internal partitions, ceilings, ducts, and (with external louvres) through external walls.The outer spigot may be connected directly to flexible ducting and other Vent-Axia ventilation accessories to suit individual applications. When installed, only the white fascia is visible. Shutter Type SD/RThe vertical extract/intake shutter fits inside the Vent-Axia unit and closes against unwanted back draughts. It can be fitted at the same time as the unit or at a later date if required. Airflow operated for extract use, cord operated for intake use. For all models mounted in vertical surfaces. Motor Purpose-designed enclosed ball bearing motor. Suitable for running at any angle. Quiet running. Supply voltage 220-240V/1/50 Hz. Suitable for operation in ambient temperatures from -40°C to +50°C. Fitted with Standard Thermal Overload Protection. (S.T.O.P.). Controller The Ecotronic Controller is recommended for use with this model to provide full function control of the fan plus the option of sensor mode using a selection of electro-mechanical switches to provide automatic switching of the fan. Alternatively, single speed extract is achieved using a normal On/Off switch. ModelSizeStock Ref £Trade S6PL472442 352.50 S7PL472443 441.97 S9PL472444 564.21 S12PL472445769.43 Accessories ShuttersSizeStock Ref£Trade S6SD/R231710 74.13 S7SD/R232710 92.09 S9SD/R233710118.86 S12SD/R234710 159.19Traditional Standard Panel Fan •Extract / intake model in 4 sizes:6", 7", 9" and 12" •IPX4 Rated •Built-in shutter available •Colour: White Fascia •Pre-wired lead for easy installation •Manufactured in weather-resistant polymeric materials •For the best performance from your fan, use a Ecotronic controller

205 Dimensions (mm) Size 6 in 7 in 9 in 12 in A 127 137 156 197 BØ 171 210 248 324 CØ 219 250 302 387 D 226 311 311 397 E 254 337 337 419 Fixing Hole Ø 254 337 337 419 Weight kg 2.5 3.0 3.5 5.8 PerformanceModel Extract Performance m 3 /h (l/s) F.I.D. Watts MAX. Sound dB(A) @ 3m Amps @ 240VS6/PL 354 (98) 32 41 0.16 S7/PL 561 (156) 34 37 0.16 S9/PL 927 (258) 53 45 0.24 S12/PL 1910 (531) 84 48 0.36 Please note that the Standard Range Panel model is not suitable for fitting within an existing Standard Range Wall fitting kit. Please use the correct Standard range Wall Core assembly.

Accessories & Controllers For ventilation systems to be truly efficient it is important for them to operate only when needed. Our range of Sentinel demand ventilation systems along with our controls and sensors help respond to the exact ventilation requirements of a room at any one time. Providing airflow only when it is required and at the level that it is required ensures that only the energy that is needed is used; no more, no less.Approved Document L recognises the value that controls can offer and you will find Vent-Axia offer a range of solutions to ensure that you can maximise the benefit of automation wherever you chose to use it.

Controllers and Sensors 208-217 Ventilation Accessories 218-225

208 Ecotronic Controller Surface Mounting An electronic controller for use with all Traditional T-Series and Standard Range models to give extract/intake and speed variation. For groups of units of any one size up to a total of 400 Watts. Do not mix T-Series with Standard Range. Where a controller is used with T-Series, 5-core flexible cord is required. •‘E’ running position for optimum efficiency. •Finger-tip sliders. •Infinitely variable speed control. •Double pole On/Off switching. •Extract/intake airflow direction. •Neon indicator. •Sensor mode for use with suitable electromechanical switches, eg. ThermoSwitch, HumidiSwitch to give automatic fan operation.•Adjustable minimum speed setting. •Knockouts for recessed wiring. •Ambient operating temperature range 0°C to +40°C. •Dimensions: 86 x 156 x 53mm (H x W x D). •Supply voltage 220-240V/1/50Hz. •Maximum load: Ecotronic - 400 Watts. •Designed to meet IP20. •BEAB Approved. Stock Ref£Trade W362320148.46 Flush Fitting BoxStock Ref£Trade 40014412.27 T-Series ®Controller SurfaceMounting A single unit controller for use with allTraditional T-Series ventilating units. With knockouts for recessed wiring. Where a controller is used with T-Series, 5-core flexible cord is required. •3-speed operation. High, medium orlow. •Finger-tip sliders. •Double pole On/Off switching.•Extract/intake airflow direction. •Sensor mode for use with suitableelectromechanical switches, eg. ThermoSwitch, HumidiSwitch to give automatic fan operation. •Unique shutter open/ fan Off setting. •Neon indicator.•Knockouts for recessed wiring. •Ambient operating temperature range0°C to +40°C. •Dimensions: 86 x 156 x 53mm(H x W x D). •Supply voltage 220-240V/1/50Hz. •Designed to meet IP20. •BEAB approved. Stock Ref£Trade W361119108.31 Flush Fitting BoxStock Ref£Trade 40014412.27 TimeSpan ®Controller Adjustable timer with overrun facility for fans ventilating WCs and other small rooms. For use with any Vent-Axia fan within maximum rating below. The fan is switched On with the light and keeps running for a pre-set period after the light is switched Off. •Fits to any single gang box. •Adjustable time delay 5-25 minutes. •Ambient operating temperature range 0°C to + 40°C. •Maximum load250W inductive. •BEAB Approved. •Dimensions:87 x 87 x 33mm (H x W x D). •Supply voltage 220-240V/1/50Hz. •Will fit single gang box for surface mounting. Stock Ref£Trade 56351974.05Surface Mounting BoxA surface mounting back box is available.Stock Ref£Trade 4100208.95 Registered design numbers: 1 030 207 Surface Mounting Controller, 1 030 208 Flush Fitting Controller.Patented Remote Speed Control Circuit. European Patent number EP 0180311. Manufacturers of some fluorescent/low energy lighting systems indicate that these can interfere with other electronic/timing circuits. For reliable operation of these circuits we recommend therefore that a tungsten filament light is used. Controllers & Sensors

209 Air Quality Sensor Automatically reacts to the depletion of air quality, sensing unpleasant smells and toilet odours to regulate mechanically ventilated areas such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. This is not a CO 2sensor. The sensor switches the fan On when the air quality declines below an adjustable preset level. This is registered by the ceramic sensing head which is self-cleaning, a process which occurs every time the unit is triggered.When the atmosphere has returned to normal, the fan will continue to run for a pre-set period (adjustable between 1-25 minutes) and then switch Off. The air quality sensor should not be used for the detection of combustible gases and is not designed for use as a smoke detector in an alarm system.For use with various Vent-Axia fans within maximum rating below. The Air Quality Sensor is also able to switch between trickle and boost speed on the appropriate ventilation units.•Ambient operating temperature range 0°C to +50°C. • Dimensions: 87 x 157 x 47mm (H x W x D).•Maximum switched load:2A inductive at 240V.•Sensor consumption: 25mA at 240V. •Supply voltage 240V/1/50Hz. Stock Ref£Trade 563506223.74 Electronic 1.5A Controller Surface mounted, providing infinitely variable speed control and features an On/Off/sensor slider with neon indicator. There is an adjustable minimum speed setting. The controller is radio suppressed to BS EN 55014 and electrical connections for use with suitable external sensors are provided.86 x 156 x 53mm (H x W x D).Hole for wall box:80x150x150mm (H x W x D). Stock Ref£Trade W300310101.53For flush fitting a metal wall box accessory is available.Flush fitting boxStock Ref£Trade 400144 12.27

210 Ambient Response Humidity Sensor A self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On’ for rapid removal of moisture laden air in domestic bathrooms and kitchens. Can be wired into controller ‘Auto’ mode connections. Night time relative humidity increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls. •Pullcord override and neon indicator.•Changeover relay switch. •Operating range: 30%-90%RH. •Ambient operating temperature +5°C to +40°C. •Dimensions:87 x 87 x 33mm (H x W x D). •Will fit single gang box for surface mounting. Stock Ref£Trade563550240VAC 50Hz200.83 European Patent No: 2298057 Surface Mounting BoxA surface mounting back box is available.Stock Ref£Trade 4100208.95 Ambient Response SELV 12Humidity Sensor 12V Safety Extra Low Voltage version for use with VA100 SELV, Solo SELV, LuminAir SELV and HR100 SELV range. The latest self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On’ for rapid removal of moisture laden air in domestic bathrooms and kitchens. Can be wired into controller ‘Auto’ mode connections.Night time relative humidity increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls. •Pullcord override and neon indicator.•Changeover relay switch. •Operating range: 30%-90%RH.•Ambient operating temperature +5°C to +40°C. •Dimensions:87 x 87 x 33mm (H x W x D). •Will fit single gang box for surface mounting.Stock Ref£Trade56355112VAC 50Hz200.83 Surface Mounting BoxA surface mounting back box is available.Stock Ref£Trade 4100208.95 Lo-Carbon AmbientResponse Humidity Sensor Designed specifically for the Lo-Carbon product range. This self programming electronic On/Off wall mounted humidity sensor reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On’ for rapid removal of moisture laden air in domestic bathrooms and kitchens. Night time relative humidity increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls.•Pullcord override and neon indicator.•Changeover relay switch. •Operating range: 30%-90%RH.•Ambient operating temperature +5°C to +40°C. •Dimensions:87 x 87 x 33mm (H x W x D). •Will fit single gang box for surface mounting.Stock Ref£Trade56355212VDC200.83 Surface Mounting BoxA surface mounting back box is available.Stock Ref£Trade 4100208.95 All of these Sensors can be wired for either On/Off or Trickle/Boost operation. Manufacturers of some fluorescent/low energy lighting systems indicate that these can interfere with other electronic/timing circuits. For reliable operation of these circuits we recommend therefore that a tungsten filament light is used. Controllers & Sensors

211 Ecotronic Humidity SensorSurface Mounting An adjustable set point, solid state On/Off sensor. A pullcord provides manual override, indicated by lamp. Adjustable from 65 to 90% relative humidity. Can be wired into controller ‘Auto’ mode connections. Incorporates changeover switch to select low/high speed.•Setting range 65% - 90%RH. •Maximum switching load 1 Amp inductive. •Pullcord override indicated by lamp. •Ambient operating temperature 0°C to +40°C. •Dimensions: 87 x 87 x 33mm. (H x W x D). •Supply voltage 220-240V/1/50Hz. Stock Ref£Trade 563532111.57 Surface Mounting BoxA surface mounting back box is available.Stock Ref£Trade 4100208.95Ecotronic® SELV 12 Humidity Sensor 12V Safety Extra Low Voltage version for use with VA100 SELV, Solo SELV, and LuminAir SELV range. Incorporates changeover switch to select low/high speed. Although suitable for siting within reach of a shower or bath we recommend this model is located out of the spray zone of a bath or shower. •Setting range 65% - 90%RH.•Maximum switching load 5.6A @ 12V AC. •Pullcord override indicated by lamp. •Ambient operating temperature 0°C to +40°C. •Dimensions: 87 x 87 x 33mm (H x W x D). •Supply voltage 12V AC. Stock Ref£Trade 563531111.57 Surface Mounting BoxA surface mounting back box is available.Stock Ref£Trade 4100208.95 Vent-Axia HumidiSwitchOperates Vent-Axia ventilating units on either a rise or a fall in humidity to control the damaging effects of condensation. •Concealed adjustment. •Setting range 20% to 80% RH. •Ambient operating temperature 0°C to +50°C. •Dimensions: 82 x 132 x 40mm(H x W x D). •Rating 2A (1A inductive). •Switching range 120-240V. •Designed for use with controllers with ‘Auto’ mode facility. •Single pole changeover contacts. Stock Ref£Trade 56350196.63The Ecotronic and Ecotronic SELV 12 Sensor can be wired for either On/Off or Trickle/Boost operation.

212 7 Day TimeSwitch For applications where regular switching is required at fixed periods or at different times on different days of the week, eg: offices, shops, pubs and restaurants. The 7-day TimeSwitch gives twelve On or Off positions per day and can be set for 7 days. The cycle will repeat until changed. •Analogue clock display and integral time switches for ease of setting. •Manual override. •Removable clear plastic cover protects TimeSwitch face. •Volt free changeover contacts. •Time base: 7 days. •Shortest switching time: 2 hours. •Maximum load: 16amp resistive (8amp inductive). •Ambient operating temperature range -20°C to +85°C. •Dimensions:104 x 74 x 52mm (H x W x D). •Supply voltage 220-240V/1/50Hz. Stock Ref£Trade56351584.30 Vent-Axia ThermoSwitch Automatically switches On fans on either a rise or fall in air temperature. The ThermoSwitch can be used with all Vent-Axia fans (via switch gear if appropriate) for the removal of warm air from buildings. It can also be used to switch On Hi-Line ceiling fans for summer cooling and to move high level warm air down to the working level during winter. •Setting range: +6°C to +30°C. •Two internal range limit/locking rings are included to allow setting within a limited temperature range or locking at a fixed t/o point. •IP20 rated. •Sealed sensing mechanism. •Snap-action, single pole, changeover contacts. •Mounting direct on surface only. •Electrical connection to screw type terminals with rear or side cable entry. •Dimensions:80 x 104 x 36mm (H x W x D). •Contact rating: 1.5 amp (inductive). •16 amps (resistive). •Maximum voltage 250V. Stock Ref£Trade56350237.95 Guardian Personnel Detector(PIR Sensor) Suitable for controlling a range of Vent-Axia fans. Continuously monitors an area and activates when a moving body is detected. •Supplied complete with wall mounting bracket. •Adjustable timer overrun (5 seconds to 20 minutes). •Supplied with lens to provide 15m (max) range, 200° detection area. •Designed to meet IP55. •Ambient operating temperature range -20°C to +50°C. •Maximum load: 10 amp resistive (5 amp inductive).•Suitable for use with fluorescent lighting up to 500W. •Internal/External use. •Supply voltage 220-240V/1/50Hz. Stock Ref£Trade563548129.33 Controllers & Sensors 7 day Time Switch & Thermoswitch can be wired for either On/Off or Trickle/Boost operation.

213 Vent-Axia Visionex PIR A wall or ceiling mounted movement detector for use with any domestic Vent-Axia mains voltage product. Also suitable for use with Vent-Axia T-Series controllers on ‘Auto’ setting and ITC controllers on sensor mode. Visionex PIR can be wired for either On/Off or Trickle/Boost operation. •Fits any UK single gang mounting box. •Adjustable timer overrun (5-25 minutes). •Range of detection up to 10 metres. •Designed to meet IP43. •Ambient operating temperature range0°C to +50°C. •Maximum load: 2.5 amps/600W inductive. Not suitable for use with lighting. •Internal use only. •No switched live required for internal rooms and WCs. •Double insulated. •Volt-free contacts. •Supply voltage 220-240V/1/50Hz. Stock Ref£Trade459623115.70 Surface Mounting BoxA surface mounting back box is available.Stock Ref£Trade 410020 8.95 Vent-Axia Visionex SELV 12 PIR A wall or ceiling mounted movement detector for use with any domestic Vent-Axia SELV 12 product.•Fits any UK single gang mounting box. •Adjustable timer overrun (5-25 minutes). •Range of detection up to 10 metres. •Designed to meet IP43. •Ambient operating temperature range0°C to +50°C. •Maximum load:5.6 amps inductive @ 12V. •Internal use only. •No switched live required for internalrooms and WCs. •Class III product. •Volt-free contacts. •Supply voltage 12V/1/50Hz. Stock Ref£Trade 459624109.17 Surface Mounting BoxA surface mounting back box is available.Stock Ref£Trade 410020 8.95 3 Pole Isolator Isolates Live, Neutral and Switched Live for integral timer fans. 6 amp, 3 pole isolator complying to the 3mm contact separation requirement for routine maintenance repair. Stock Ref£Trade 56351818.41 Surface Mounting BoxA surface mounting back box is available.Stock Ref£Trade 4100208.95

214 Fan Speed Adjuster5 step speed adjuster for domestic kitchen extract fans, that can reduce the speed to 40% of its maximum performance. 91mm x 176mm x 85mm (WxHxD). Stock Ref £Trade 458153 80.415 Step Auto ControllerUsed in conjunction with speed controllable fans to provide 5 stepped speed without electronic motor ‘hum’. Several fans can be connected to one transformer provided their combined load does not exceed the controller rating. Single phase: 3.5 , 6.0 and 7.5amp. Rotary switch giving On/Off and five speeds. Output voltages at 240V/1PH/50Hz 0, 90, 115, 140, 175, 240 volts.Neon indicator. Enclosures are protected to IP54. DimensionsStock Ref£Trade 230 x 168 x 11810314103215.81 230 x 168 x 11810314105265.93 284 x 240 x 13210314107337.97 Additional ratings and three phase units are available - see page 454 Ventwise ControllerThe award winning Ventwise controller has been designed to fully automate a ventilation system. The unit can be used on intermittent or continuous systems, switching a fan between Off and On or from trickle to boost speed. The controller saves energy by only switching when cooking is taking place or condensation is being generated. The current sensor detects when the power supply to an oven or hob is switched on. The temperature sensor detects the rise in temperature in the hot feed to a bath or shower. Suitable for 240V single phase, the Ventwise is capable of switching 2 amps or 500 Watts. Ideal for student accommodation, social and sheltered housing, the Ventwise maintains indoor air quality without the need for manual switching. 160mm x 85mm x 45mm (WxHxD). Controller 3 sensor inputsStock Ref £Trade 435960 391.10 Controller 6 sensor inputs Stock Ref£Trade 446409 443.38 Current Sensors6m cableStock Ref £Trade 43595690.24 12m cableStock Ref £Trade 43595790.24 Temperature Sensors6m cableStock Ref £ Trade 43595890.2412m cableStock Ref £Trade 435959 90.24 Controllers & Sensors

215 Remote Delay TimerA remote delay timer for use with all domestic products gives the option of offering a 2 minute delay before the fan starts. Once the fan has started the overrun timer is adjustable between 5-25 minutes.Stock Ref£Trade 45798669.60 Surface Mounting BoxA surface mounting back box is available.Stock Ref£Trade 4100208.95 Isolator Relay ControllerAllows fan unit to be isolated from other mains circuit when used with TIM2, Trickle/boost switch or light switch control.Stock Ref£Trade 44203064.46 Surface Mounting BoxA surface mounting back box is available.Stock Ref£Trade 4100208.95 150VA TransformerSurface Mounting Transformer with six voltage selections for trickle settings to match dwelling volume. Provides Boost/Trickle ventilation when used with humidity sensors or a manual switch. 95 x 225 x 75mm (H x W x D). Stock Ref£Trade 563538107.06

216 Normal Boost SwitchA single gang switch to boost from high to low speeds on all heat recovery systems.85 x 85 x 10mm (H x W x D).Stock Ref£Trade45521338.34 Momentary Push SwitchCompatible with the Sentinel Kinetic range, the momentary switch boosts the unit for 30 minutes.85 x 85 x 10mm (H x W x D).Stock Ref£Trade44892920.05 Normal Boost Switch with Light IndicatorA single gang switch with LED illumination when in the Boost condition.85 x 85 x 10mm (H x W x D).Stock Ref£Trade44906038.34 VCON6A double gang switch to boost from high to low speeds.85 x 145 x 10mm (H x W x D).Stock Ref£Trade37035660.71 LED Indicator Compatible with the Sentinel Kinetic range, the LED indicator illuminates when the MVHR unit requires a filter check or if the unit has a fault. Supplied with 15 metres of cable.85 x 85 x 10mm (H x W x D).Stock Ref£Trade44835630.93 Normal Boost Purge SwitchA single gang switch to operate between normal, boost and purge speeds.85 x 85 x 10mm (H x W x D).Stock Ref£Trade510845437.84 Normal Boost Switch - Stainless Steel A single gang switch to operate normal/boost functions on MVHR systems. Brushed stainless steel finish.90 x 90 x 18 (H x W x D).Stock Ref£Trade43732046.72 Controllers & Sensors

217 2-Way Switch and Neons A double gang switch to boost from high to low speeds on all heat recovery systems, incorporating neon lights to indicate speed settings. Suitable changeover relay required. 85 x 145 x 10mm (H x W x D).Stock Ref£Trade 45974696.56 HR500 Controller Suitable for use with HR500 MVHR units. Surface mounting. On/Off remote sensor mode. Heat exchange, single fan extract or twin fan extract modes. Infinitely variable speed. Minimum speed setting.Stock Ref£Trade W14301010157.12 3 Speed Controller A three position rotary control which enables the unit to be manually switched from permanent trickle ventilation to either medium or boost speed.85 x 85 x 25mm ( H x W x D ).85 x 85 x 37mm ( H x W x D ): with rotary switch.Stock Ref£Trade 56353341.59 TIM2 Overrun Timer The TIM2 is a remote mounting electronic overrun timer with a relay output. 2 Amp indication load maximum. Adjustable overrun 2-30 mins. Ideal for where fans are to be controlled in conjunction with a lighting circuit or activated by remote sensors. 76 x 76 x 41mm. (H x W x D).Stock Ref£Trade 37034688.46

218 Fixing Plates A single plate available in 300mm and 450mm square modular sizes for permanent fixing on walls or for use with other modular components. Manufactured in high impact recyclable thermoplastic. Unit SizeStock Ref£Trade 6”561136 43.91 7”561137 43.91 9”561139 66.59 12”561142 66.59 ‘A’ ØVent-Axia fixing plate Unit size ‘A’ ØModule Size 6” 184mm 300mm7” 222mm 300mm9” 260mm 450mm12” 337mm 450mmT-Series Adaptor KitsUsed for T-Series Window models in secondary double glazing, Roof models in secondary double glazing in exposed areas, Roof models through roofs and Darkroom models installed through either roof or walls. Adaptor kits allow units to be installed on two surfaces. T-Series Adaptor kits consist of two Mounting plates with weather-tight seals and a set of fixing screws. Unit SizeStock Ref£Trade 6”W56103149.23 7”W56103261.59 9”W56103379.59 12”W56103496.63 T-Series Extended Fixing Rod SetsFor use with T-Series Window and Roof models fitted through walls. Consists of a set of rods which are cut to suit the wall thickness. Maximum thickness of wall 370mm. Rod thread 3.5mm. Unit SizeStock Ref£Trade 6”, 7” & 9”568104 11.53 12”568106 16.79 Ventilation Accessories

219 Wall Liner SectionDesigned for T-Series units installed in walls thicker than 315mm, each liner section provides a maximum extension of 150mm. Wall liner section can also form a frame for Panel models in walls. T-Series Wall Liners Unit SizeStock Ref£Trade 6”46009438.56 7”46009544.71 9”46009652.48 12”46008656.95 Mounting BoxesA flanged sleeve in 300mm and 450mm square modular sizes used as an interconnecting sleeve between other modular accessories. Mounting boxes will accept the depth of a unit and can be mounted in conjunction with a Fixing plate and Eggcrate grille for ventilation through ceilings. Manufactured in flame retardant high impact recyclable thermoplastic. Duct length 200mm. Unit SizeStock Ref£Trade 6”/7”560236102.70 9”/12”560239113.46 Unit Size Mounting boxmodular size 6”/7” 300mm 9”/12” 450mm Joining Bolt Set GEN Set of 8 nuts, bolts and washers. Stock Ref£Trade5630007.10 Single SpigotsSingle spigots in 300mm and 450mm square modular sizes. Used to connect Flexible ducting to Mounting boxes and other modular accessories or can be fixed directly to walls. Manufactured in flame retardant high impact thermoplastic. Unit SizeNom DiaStock Ref£Trade 6” 175mm(B)56063772.47 6”/7” 225mm(B)56063972.47 7” 250mm(A)56064072.47 9” 300mm(A)56064272.47 9” 300mm(B)566142102.52 12” 400mm(B)566146102.52 Vent-Axia single spigot Unit Size ‘A’ ØModule Size 6” B 175mm 300mm 6” B 225mm 300mm 7” B 225mm 300mm 7” A 250mm 300mm 9” A 300mm 300mm 9” B 300mm 450mm 12” B 400mm 450mm

220 Multi-Spigot PlatesAvailable with 2, 3, 4 or 5 circular spigots of 100mm diameter. Multi-spigot plates are used in conjunction with 100mm Flexible ducting and other modular accessories to ventilate several small areas especially internal WCs. For use with Size 6 units only. Manufactured in flame retardant high impact recyclable thermoplastic. Available in 300mm square modular size. DescriptionStock Ref£Trade 2-3-4 Spigots56073475.47 5 Spigots56073585.42 Cone Connectors GEN Used in conjunction with a Size 6 StandardRange Panel model to reduce the outlet spigot (175mm Ø) to 100mm Ø flexible or rigid ducting. The Cone connector is 280mm long and incorporates a splitter for improved performance. Manufactured in flame retardant, high impact thermoplastic.Colour: Grey. Unit SizeStock Ref£Trade6”56093656.26 Not for use with T-Series Range. T-Series Direct Mount SpigotsUsed to connect Flexible ducting directly to the inlet side of all T-Series models and the outlet side of T-Series Window models. Manufactured in flame-retardant high impact recyclable thermoplastic. Unit SizeStock Ref£Trade 6”All models56050158.92 7“ All models56050264.22 9”WW/RF56050371.01 9“ WL/PL560504109.03 12” All models560505127.56 T-Series Darkroom Cowl Assembly For use with all T-Series fans for Darkroom applications. Designed to give light protection. Can also be used in other light sensitive areas such as medical, dental and veterinarian applications. Unit SizeStock Ref£Trade 6”46058573.75 7“46058683.01 9” 46058783.01 12”460588117.63 Standard Range Protective Grilles Where Standard Range units are installed in low positions, finger guards provide extra protection to VDE, DIN 31001. Standard Range internal grille (all models) Unit SizeStock Ref£Trade 6”563106 15.38 7”563107 15.38 9”563109 20.01 12”56311222.44 Standard Range external grille (window models)Unit SizeStock Ref£Trade6”563406 15.107”563407 15.109”563409 22.4412”563412 22.44 Ventilation Accessories

221 Plenum Boxes The Plenum box allows square grilles and diffusers to connect to circular duct. Each box size has a two diameter circular spigot for maximum versatility. The box is deep enough to accommodate both a double deflection grille and opposed blade damper. Manufactured in flame retardant high impact recyclable thermoplastic. SizeStock RefNom. Ø£Trade 200mm560601125/150mm34.22 250mm560602150/175mm37.21 300mm560603200/225mm44.39 300mm560604250/300mm56.74 450mm560605315/400mm68.42 Dimensions (mm) Stock Ref. A B CØ DØ E F 560601 200 130 125 150 25 25 560602 250 130 150 175 25 25 560603 300 130 200 225 25 25 560604 300 130 250 300 25 25 560605 450 130 315 400 25 25 Single Deflection Grilles Single deflection grilles are suitable for either side wall or exposed duct applications. The Single deflection grille has a single row of blades which permit up to 45° deflection of the air in one plane. Satin silver finish. Size 6/7 fits 300mm square modular size and size 9/12 fits 450mm square modular size. Module sizeStock Ref£Trade 200mm sq56137032.50 250mm sq56137141.66 300mm sq56137253.13 450mm sq56137394.17Double Deflection Grilles Double deflection grilles are suitable for supply air for either side wall or exposed duct applications. The Double deflection grille has two rows of blades set at 90° apart which permit up to 45° deflection of the air in two planes. Satin silver finish. Size 6/7 fits 300mm square modular size and size 9/12 fits 450mm square modular size. Module sizeStock Ref£Trade 200mm sq56138051.99 250mm sq56138167.60 300mm sq56138284.91 450mm sq561383155.99

222 Eggcrate GrillesEggcrate grilles can be used for air replacement or air extract purposes. Used underneath Roof plate assemblies with Roof models, underneath single spigots in ceilings, underneath mounting boxes and on the inside faces of walls that have units in fixed and removable wall plates on the outside of the wall. Comprising a 13mm square by 13mm deep mesh eggcrate core housed in a frame which has a satin silver or white finish. Size 6/7 fits 300mm square modular size and size 9/12 fits 450mm square modular size. Size 6/7 - 785cm 2free area Size 9/12 - 1810cm 2free area 200mm Sq - 340 cm 2 250mm Sq - 530 cm 2 Satin finish.Module sizeStock Ref£Trade 200mm sq56130342.53 250mm sq56130560.40 300mm sq561301 62.91 450mm sq56130293.70 White finish.Module sizeStock Ref£Trade 125mm sq560846 28.64 200mm sq560847 42.53 250mm sq560848 52.35 300mm sq560849 60.09 450mm sq560850 93.70 Opposed Blade Dampers Opposed blade dampers are used to regulate air flow through all Vent-Axia grilles and diffusers. Key operated. This action ensures that the downstream airflow is non-directional when the damper is in the partially closed position. Opposed blade dampers have aluminium blades and the frame is left in natural mill finish. Can be used in conjunction with Eggcrate, Single deflection and Double deflection grilles. Size 6/7 fits 300mm square modular size and size 9/12 fits 450mm square modular size. Module sizeStock Ref£Trade 200mm sq561341 33.86 250mm sq561342 43.47 300mm sq561343 53.13 450mm sq56134489.35 Filtered Inlet GrilleFor ceiling, panel or glass mounting. Consists of a size 6 grille, washable filter, adaptor kit and a stepped spigot to suit 100, 125 or 150mm diameterducting. Grille size:226mm x 220mmSpigot depth:100mm Fixing hole diameter:184mm Stock Ref £TradeW56353692.27 4-Way DiffusersManufactured in polypropylene plastic. Four diffuser cassettes can be set for downward or 45° discharge in any of sixteen directional combinations.Colour: Ivory Neck SizeStock Ref£Trade 225mm1054623032.66 300mm1054630041.72 350mm1054635051.48 Neck Adaptor Used to connect Flexible ducting directly to 4-way diffusers. Integral volume control damper for duct sizes up to 300mm. Diffuser4-Way Duct SizeNeck SizeStock Ref£Trade 150mm Ø225mm1054715025.72 200mm Ø225mm1054720029.75 250mm Ø300mm1054725037.78 300mm Ø350mm1054730048.49 Ventilation Accessories

223 Window/Wall/Ceiling Termination Sets Used to terminate Flexible ducting at windows. Can be used with the Extended fixing rod set or Fixing plates for termination at walls. Used with Flexible ducting and Worm drive clips.Consists of a Direct mount spigot, Adaptor kit, Window grille and all screws. Unit SizeSpigot DiaØStock Ref£Trade 6”175mmW560151115.84 7” 225mmW560152 135.90 9” 300mmW560153168.5512” 400mmW560154 244.29 Other sizesSpigot DiaØStock Ref£Trade 100/125/150mmW10554150119.17 200mmW10554200133.62 250mmW10554250148.09 315mmW10554315169.02 Pressure Drop (Pa) Mean Duct Velocity m/s 60 50 40 30 20 10 0 0 1 2 3 4 5 6 7 8Air Replacement Non-Vision Grilles Satin finishNon-vision grilles consist of a single row of overlapping chevron vanes. Used as transfer grilles for doors or partitions, the overlapping vanes prevent through-vision. Module sizeStock Ref£Trade300mm sq56131181.07450mm sq561312137.08Black finishIn addition to preventing through-vision the black finish also limits light transference. Use two grilles back to back for darkroom applications. Module sizeStock Ref£Trade300mm sq56132181.07450mm sq561322137.08Roof Termination Sets Used to terminate Flexible ducting at roofs. Consists of: Direct mount spigot, Adaptor kit, Roof cowl, Deflector and all screws. Can be used with Roof Plate Assemblies for installation on flat roofs. T-series unitsSizeSpigot ØStock Ref£Trade 6” 175mm560161144.58 7” 225mm560162192.989” 300mm560163215.3812” 400mm560164341.13Vent-Axia roof terminationDiameterStock Ref£Trade 100/125/150mm1055515084.96 200mm10555200121.20 250mm10555250172.03 315mm10555315192.22Mean Duct Velocity m/sPressure Drop (Pa) 2 0 0 1 3 4 5 6 7 8 60 50 40 30 20 10

224 Air Replacement Non-Vision Door Grilles with Matching Flanges Non-vision grilles consist of a single row of overlapping chevron vanes to prevent through-vision, supplied with matching flanges.The grille is fitted to one side of the door with the matching flange on the other side. Suitable for door thicknesses of 19-49mm. Available inSilver or Brown finish, in two sizes, 600 x 150 and 600 x 300mm. Satin finishSizeStock Ref£Trade 600 x 150mm561390125.51 600 x 300mm561391183.20 Brown finishSizeStock Ref£Trade 600 x 150mm560900125.51 600 x 300mm560901183.20 Heavy Duty T-SeriesWall Grilles Tough aluminum construction for accesible public areas. Fits T-Series wall models in place of existing external grille. Finish T-Series grey. SizeStock Ref£Trade 6”452725 83.50 7”45272697.14 9”452727105.22 12”452728117.67 External Louvres Mill Weather resistant external louvres are suitable for air intake or dischargeand for use with ducting on external walls. The narrow blade construction has a 38mm pitch set at 45° with a depth of 41mm and an integral rain lip. Standard 32mm wide undrilled outer flanges in aluminium have fully welded mitre corners as standard. Size 6/7 fits 300mm square modular size and size 9/12 fits 450mm square modular size. Size 6/7 - 345cm 2free area Size 9/12 - 824cm 2free area Satin finishSizeStock Ref£Trade 225mm sq56135089.35 300mm sq56135191.77 400mm sq561355130.99 450mm sq561352152.34Brown finishSizeStock Ref£Trade 225mm sq56091084.20 300mm sq56091194.31 400mm sq560912142.54 450mm sq560913169.07Louvre GrillesLouvre grilles can be used for air replacement, for extract purposes and as an external louvre. Available in four sizes, the assembly fits over rather than into the aperture making it especially useful where there are space restrictions within the duct. Manufactured in thermoplastic. Choice of three colours: White, Brown and Grey.Size6- 190cm 2free area Size7- 335cm 2free area Size9- 415cm 2free area Size 12- 705cm 2free area Grille Dimensions (mm)Sizew x h 6”= 310 x 303 7”= 352 x 345 9”= 391 x 388 12”= 470 x 467The grilles and surrounds are moulded in ABS plastic to tone in with building materials, therefore an equivalent BS or RAL colour reference cannot be given. Unit SizeColourStock Ref£Trade 6” GreyW561431 42.73 6” Brown561411 42.73 6” White561421 42.73 7” GreyW561432 51.28 7” Brown56141251.28 7” White56142251.28 9” GreyW561433 63.35 9“Brown56141363.33 9”White561423 63.33 12” GreyW561434 80.71 12” Brown561414 80.71 12” White561424 80.71 Ventilation Accessories

225 Roof Plate Assemblies Vent-Axia roof plate assemblies are manufactured in high impact recyclable thermoplastic. They consist of a strong one piece moulded plate with extended sides to assist flashing and weather protection. A separate sub-frame is provided for permanent fixing to the roof kerb. The Vent-Axia Roof model is then fitted to the plate using a suitable sealing compound between the Cowl and plate, ensuring a weather-tight seal. SizeStock Ref£Trade 6”560136146.65 7”560137146.65 9”560139 168.52 12”560142 168.52 Size A B C 6” 300mm 335mm 465mm 7” 300mm 335mm 465mm 9” 450mm 490mm 615mm 12” 450mm 490mm 615mm In addition to the size 6, 7, 9 & 12 Roof Termination Sets, the Roof Plate Assemblies can also be used with the following Roof Terminations part numbers. 10555150 use size 6 Roof Plate Assembly10555200 use size 7 Roof Plate Assembly10555250 use size 9 Roof Plate Assembly10555315 use size 12 Roof Plate Assembly Joining PiecesUsed to join lengths of flexible ducting to give a long-lasting airtight connection. Duct SizeStock Ref£Trade 100mm Ø56180413.36 125mm Ø56180516.12 150mm Ø56180618.84 175mm Ø561807 19.48 200mm Ø56180819.79 225mm Ø561809 22.51 250mm Ø56181026.81 300mm Ø561812 31.74 315mm Ø56181332.22 400mm Ø56181633.43 Worm Drive ClipsStainless steel tightening band with quick-fix screwed ends for securing flexible ducting. Max. ØStock Ref£Trade 110mm5617042.85 215mm5617073.84 270mm561710 5.09 380mm561715 5.79 525mm561720 6.29 660mm5617266.47 Standard Range Adaptor Kits Used for Standard Range Window models in secondary double glazing, Roof models in secondary double glazing in exposed areas and Roof models through roofs.Adaptor kits allow units to be installed on two surfaces and consist of an additional shroud and gasket, locking ring and seal. The shroud and gasket fit to the outside part of the unit, the locking ring and seal going to the inside part. Fitting through holes in both Fixing Plates or glass, Vent-Axia’s spigot and ring method of fixing allows simple installation separately to both parts. Colour: Ivory.Unit sizeStock Ref£Trade 6”561011 49.23 7”561012 61.57 9”561013 79.59 12”56101496.63

Plate &Case Fans Vent-Axia Plate and Case axial fans have been developed with a detailed understanding of air movement requirements within the European market. The products are designed to meet the exacting demands of both modern building services as well as the replacement market.The fans are supplied fully assembled and ready for installation in any application together with a comprehensive range of accessories and controllers. Our new range of VSP and VSC fans have been designed incorporating the FE2 Owlet impeller. This state of the art impeller ensures maximum efficiency and minimum noise for the application. The bifurcated and cased axial ranges along with the KAF range are designed for reliable operation within the aggressive environments of commercial kitchens.

Sabre ®Plate Mounted Sickle Fans (VSP) 228-233 Sabre ®Sickle Short Case Fans (VSC) 234-241 Long Case Axial Fans (LCA) 242-271 Kitchen Axial Fans (KAF) 272-275 Bifurcated Case Axial Fans (BIFA) 276-301

228 Sabre Plate Mounted Sickle Fans (VSP) •Swept impeller with Aerofoil blades, winglets and serratedtrailing edge for optimum performance •One shot die cast impeller, dynamically balanced forsmoother operation •Operating temperature up to 70°C •External Rotor Motors on all models for compact efficient design •All models speed controllable•Guards fitted as standard on all models •Thermal Overload Protection for motor protection •Maintenance free sealed for life bearings •2 Year Guarantee The latest generation of the Vent-Axia Sabre ®Plate Mounted Sicklefans incorporate the very latest FE2 Owlett impeller offering improved performance over the previous ranges with up to 7dB(A) reduction in sound and up to 15% improvement in efficiency ensuring the best available fan performance in its class. The advanced blade design, matched to a purpose designed external rotor motor ensures unrivalled reliability and controllability. Design and Development Using a combination of NASA research into wing performance and winglets, coupled with a study of bird flight, has enabled the development of the best available Sickle blade profile. By matching this to a purpose designed close fitting mounting plate ensures best use of this blade technology thereby reducing noise and improving the performance in plate axial fans. Construction Vent-Axia Sabre ®Plate Mounted Sickle fans are based on an integratedimpeller and external rotor motor design, which produces a very compact unit. Together with a specially designed bell mouth inlet and mounting plate, the complete fan is lightweight and ensures an excellent performance to sound level ratio. The mounting plate is formed from a single sheet, protected with a tough epoxy paint finish. Inlet finger guards and motor supports are manufactured from steel rod and electro welded for extra strength. Finger guards give protection to BS 848 Part 5. Manufacture is controlled to BS EN ISO 9001 Standards. Impellers The impellers incorporate the latest in sickle blade aerofoil technology to ensure minimum sound and maximum performance. Impellers up to 400mm diameter are moulded from a composite polymer, impellers above this size are Aluminium. The motors and impellers are factory matched, statically and dynamically balanced to ISO 1940 part 1, Quality Class G.6.3. Motors The external rotor motors are specifically designed and styled for this range of fan. Ball bearings are greased for life. Sizes 315 – 710 motors are protected to IP54 against dust and moisture, complying with BS EN 60529. They have ribbed aluminium body castings for efficient cooling with Motor insulation to Class ‘F’ (from -40°C to + 70°C). Speed controlled sizes 450 to 710, 6 & 8 pole motors are only suitable for operating temperatures of up to 40°C. Electrical The Sabre ®Plate Mounted Sickle fan range is available for either singlephase 220-240V 50 Hz capacitor start and run or three phase 380-415V 50Hz. Motors are fitted with Thermal Overload Protection which should be wired into all controller circuits and into starter contactors to prevent motor damage due to overloading / overheating. Speed Control Units are suitable for speed control by either electronic, voltage reduction or frequency inverters where permissible. For optimum efficiency and controllability Vent-Axia recommend the use of the eDemand Inverter controller to give close control via sensors or manual control. Form of Running Plate mounted fans (ex-stock) are supplied for extract use (Form ‘A’ running). Performance The fan performance is in accordance with tests to ISO 5801.

229 SoundLevels Fan sound levels are measured in a reverberant chamber in accordance with ISO 3744 Part 1. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10 -5 Pa (20 micro-Pascal). The sound power level spectra figures aredB with a reference level of 10 -12Watts (1 pico-watt).To ensure minimum noise levels during speed control, either an auto transformer or eDemand inverter speed control is recommended. Accessories A full range of accessories is available with the Sabre ®Plate MountedSickle fans:•Electronic speed controllers •Auto transformer speed controllers •eDemand inverter speed control •D.O.L. starters •Louvre shutter •Discharge guard Stock Ref kg A B C D E F G H J VSP25012/14 3.3 370 320 260 264.5 78 73.4 6 50 7 VSP31514/34 6.7 430 380 349 349 78 83.9 11 63 9 VSP35514/34 7.5 485 435 390 390 78 82.9 12 68 9 VSP40014/34 7.8 549 490 412 419.8 90 91.5 12 88 9 VSP45014/34/16/36 16.2 575 535 463 480 110 143.5 14 96 11 VSP50014/34/16/36 20.1 655 615 517 528 84.5 141.5 16 104 11 VSP56014 31.8 725 675 568 589 98.3 167.5 16 119 11 VSP56034/16/36 24.2 725 675 568 589 82.5 162.5 16 119 11 VSP63034/36 41.6 805 750 643 664 111 159.5 20 130 11 VSP63016 33.7 805 750 643 664 70.5 174.5 20 130 11 VSP71016/36/38 38.6 850 810 720 763 44 201.5 20 150 14.5 Stock Ref a b c Ød 10502325 397 64 351 8 10502375 449 64 403 8 10502450 501 64 455 8 10502525 553 64 507 8 10502630 808 150 735 8 10502800 1010 140 - 8 Stock Ref a b c Ød eLS250 294 265 25 6 230 LS315 344 276 26 6 295 LS355 398 312 26 6 329 LS400 458 365 26 6 382 LS450 499 395 31 6 432 LS500 544 444 31 6 477 LS560 605 533 31 6 533 LS630 694 627 31 6 626 LS710 790 722 43 6 722 If a discharge guard is required with a louvre shutter the next size up discharge guard should be selected. Louvre Shutter Discharge Guard ‘K’ factor loss 0.25 Fan Dimensions (mm) Accessories Dimensions (mm)

230 Performance Curves Performance Guide Sound Power Level Spectra dB (ref 10 -12Watts) Stock Ref 63Hz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 8KHz dB(A) @ 3m VSP25012 65 70 68 66 64 66 62 55 50 VSP25014 56 63 56 54 53 53 49 41 37 VSP31514 71 70 65 60 58 59 55 47 45 VSP31534 75 71 62 60 61 62 59 51 47 VSP35514 67 70 67 64 58 60 53 45 46 VSP35534 74 66 61 63 64 63 59 53 48 VSP40014 72 73 66 62 60 59 54 48 46 VSP40034 67 67 61 60 60 59 54 48 47 Volume (m3/s) 00.2 0.4 0.6 0.8 1.0 1.2 Volume (m3/s) 00.2 0.4 0.6 0.8 1.0 1.2 100 75 50 25 0 S tatic Pressure (P a) 100 75 50 25 0 S tatic Pressure (P a) 250 to 400 dia. - Pole 2 & 41 Phase3 Phase 2 4 3 5 7 6 8 1 1 IP Motor F.L.C S.C.Volume m 3 /s @ Pa dB(A) @ Stock Ref Supply Rating kW Amps Amps Poles rpm Curve 0 25 50 75 100 3m VSP25012 230/1/50 IP54 0.12 0.54 2.16 2 2160 1 1 Volume m 3 /s 0.48 0.44 0.40 0.36 0.25 50 Power Watts 110 115 118 121 125 VSP25014 230/1/50 IP54 0.05 0.24 0.96 4 1370 1 2 Volume m 3 /s 0.27 0.22 37 Power Watts 46 48 VSP31514 230/1/50 IP54 0.12 0.54 2.16 4 1360 1 3 Volume m 3 /s 0.67 0.63 0.51 0.45 45 Power Watts 111 118 124 130 VSP31534 400/3/50 IP54 0.12 0.39 1.7 4 1450 1 4 Volume m 3 /s 0.62 0.54 0.47 0.38 47 Power Watts 105 115 117 120 VSP35514 230/1/50 IP54 0.13 0.56 2.24 4 1260 1 5 Volume m 3 /s 0.90 0.82 0.72 0.58 46 Power Watts 132 141 151 162 VSP35534 400/3/50 IP54 0.19 0.4 1.6 4 1390 1 6 Volume m 3 /s 0.97 0.90 0.65 0.67 48 Power Watts 152 168 176 178 VSP40014 230/1/50 IP54 0.24 1.05 4.2 4 1340 1 7 Volume m 3 /s 1.07 1.00 0.89 0.78 0.61 46 Power Watts 166 195 200 210 240 VSP40034 400/3/50 IP54 0.23 0.46 1.6 4 1360 1 8 Volume m 3 /s 1.06 1.00 0.90 0.78 0.64 47 Power Watts 160 170 190 205 220

231 Sound Power Level Spectra dB (ref 10 -12Watts) Performance Curves Performance Guide Stock Ref 63Hz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 8KHz dB(A) @ 3m VSP45014 67 69 71 63 63 63 59 53 49 VSP45034 72 70 65 65 64 64 59 53 49 VSP45016 57 62 59 56 56 56 50 41 41 VSP45036 71 66 60 60 60 58 51 43 44 VSP50014 71 75 67 63 67 68 60 52 51 VSP50034 74 72 66 66 68 68 62 56 52 VSP50016 66 72 70 55 59 58 51 43 44 VSP50036 77 77 72 66 64 61 54 47 47 Volume (m3/s) 00.5 1.0 1.5 2.0 2.5 3.0150 125 100 75 50 25 0 S tatic Pressure (P a) Volume (m3/s) 00.5 1.0 1.5 2.0 2.5 3.0150 125 100 75 50 25 0 S tatic Pressure (P a) 450 to 500 dia. - Pole 4 & 6 1 Phase3 Phase 2 4 3 5 7 6 8 1 1 IP Motor F.L.C S.C.Volume m 3 /s @ Pa dB(A) @ Stock Ref Supply Rating kW Amps Amps Poles rpm Curve 0 25 50 75 100 125 150 3m VSP45014 230/1/50 IP54 0.6 2.9 10 4 1320 1 1 Volume m 3 /s 1.96 1.89 1.76 1.64 1.47 1.25 49 Power Watts 480 500 520 530 540 550 VSP45034 400/3/50 IP54 0.54 1.1 4.4 4 1350 1 2 Volume m 3 /s 1.97 1.89 1.79 1.68 1.53 1.36 49 Power Watts 440 460 480 505 520 530 VSP45016 230/1/50 IP54 0.19 0.9 3.6 6 910 1 3 Volume m 3 /s 1.32 1.17 0.94 41 Power Watts 165 175 180 VSP45036 400/3/50 IP54 0.36 0.66 2.64 6 1020 1 4 Volume m 3 /s 1.64 1.44 1.25 1.01 44 Power Watts 325 350 360 380 VSP50014 230/1/50 IP54 0.7 3.2 12.8 4 1230 1 5 Volume m 3 /s 2.47 2.33 2.19 1.97 1.83 1.58 51 Power Watts 630 660 670 690 720 740 VSP50034 400/3/50 IP54 0.84 1.45 5.8 4 1340 1 6 Volume m 3 /s 2.63 2.50 2.36 2.22 2.07 1.92 1.67 52 Power Watts 620 650 680 720 740 750 800 VSP50016 230/1/50 IP54 0.27 1.25 5.0 6 910 1 7 Volume m 3 /s 1.75 1.61 1.36 1.03 44 Power Watts 250 265 280 295 VSP50036 400/3/50 IP54 0.54 0.96 3.84 6 940 1 8 Volume m 3 /s 2.07 1.81 1.56 1.25 47 Power Watts 470 500 520 540

Specification Range 11th Edition - Vent-Axia - 2017

232 Stock Ref 63Hz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 8KHz dB(A) @ 3m VSP56014 79 78 74 74 77 77 73 66 62 VSP56034 84 78 76 74 75 74 70 63 57 VSP56016 75 73 66 65 67 66 60 54 50 VSP56036 77 77 67 66 67 66 60 54 51 VSP63034 85 80 77 75 78 77 71 66 62 VSP63016 74 71 73 68 68 66 60 54 52 VSP63036 84 75 71 71 74 71 65 59 57 VSP71016 81 81 72 69 70 67 61 57 52 VSP71036 69 69 68 67 68 65 59 52 49 VSP71038 66 63 63 65 62 59 50 44 45 Sound Power Level Spectra dB (ref 10 -12Watts) Performance Curves Performance Guide IP Motor F.L.C S.C.Volume m 3 /s @ Pa dB(A) @ Stock Ref Supply Rating kW Amps Amps Poles rpm Curve 0 25 50 75 100 125 150 200 250 3m VSP56014 230/1/50 IP54 1.15 5 20 4 1330 1 1 Volume m 3 /s 3.00 2.92 2.78 2.69 2.51 2.31 2.22 1.71 62 Power Watts 810 830 870 890 900 980 1000 1100 VSP56034 400/3/50 IP54 1.05 2.2 8.8 4 1280 1 2 Volume m 3 /s 3.11 3.03 2.92 2.76 2.53 2.36 2.17 1.53 57 Power Watts 742 800 840 860 910 920 940 1044 VSP56016 230/1/50 IP54 0.39 1.8 7.2 6 930 1 3 Volume m 3 /s 2.22 2.07 1.86 1.64 1.26 50 Power Watts 369 394 415 438 458 VSP56036 400/3/50 IP54 0.58 1.1 4.4 6 910 1 4 Volume m 3 /s 2.47 2.21 1.96 1.67 1.14 51 Power Watts 489 518 542 556 576 VSP63034 400/3/50 IP54 2.4 4.6 18.4 4 1320 1 5 Volume m 3 /s 5.71 5.56 5.35 5.19 5.03 4.83 4.56 4.16 3.44 62 Power Watts 2305 2350 2400 2450 2500 2540 2587 2628 2639 VSP63016 230/1/50 IP54 0.6 2.8 11.2 6 910 1 6 Volume m 3 /s 3.10 2.92 2.59 2.31 2.06 52 Power Watts 568 603 650 679 710 VSP63036 400/3/50 IP54 1.5 2.6 10.4 6 1040 1 7 Volume m 3 /s 4.56 4.32 4.07 3.81 3.56 3.13 2.73 57 Power Watts 1538 1550 1593 1610 1645 1661 1666 VSP71016 230/1/50 IP54 0.95 4.4 17.6 6 850 1 8 Volume m 3 /s 3.86 3.64 3.40 3.03 2.68 2.33 1.70 52 Power Watts 607 666 700 760 808 850 950 VSP71036 400/3/50 IP54 0.94 1.7 6.8 6 900 1 9 Volume m 3 /s 4.04 3.81 3.50 3.19 2.92 2.61 2.00 49 Power Watts 560 620 700 768 813 861 920 VSP71038 400/3/50 IP54 0.62 1.05 4.2 8 690 1 10 Volume m 3 /s 3.51 3.12 2.69 1.94 45 Power Watts 451 510 540 616 Volume (m3/s) 0 1 2 3 4 5 6 250 225 200 175 150 125 100 75 50 25 0 S tatic Pressure (P a) Volume (m3/s) 0 1 2 3 4 5 6 250 225 200 175 150 125 100 75 50 25 0 S tatic Pressure (P a) 2 4 3 5 7 6 8 9 1 1 1 10 560 to 710 dia. - Pole 4 & 6 & 81 Phase3 Phase

233 Accessories Stock Ref Supply ElectronicController 5 Step AutoTransformer eDemandVoltage eDemand 3phInverter eDemand 1phin 3ph outInverter eDemand 1PhInverter D.O.L StarterOverload VSP25012 230/1/50 W10303102M 10314102 444164 - - 444169 444744 444698 VSP25014 230/1/50 W10303102M 10314102 444164 - - 444169 444744 444697 VSP31514 230/1/50 W10303102M 10314102 444164 - - 444169 444744 444699 VSP31534 400/3/50 - 10314301 444166 444172 444177 - 444747 444699 VSP35514 230/1/50 W10303102M 10314102 444164 - - 444169 444744 444699 VSP35534 400/3/50 - 10314301 444166 444172 444177 - 444747 444698 VSP40014 230/1/50 W10303102M 10314102 444164 - - 444169 444744 444700 VSP40034 400/3/50 - 10314301 444166 444172 444177 - 444747 444698 VSP45014 230/1/50 10303103 10314103 444164 - - 444169 444744 444702 VSP45034 # 400/3/50 - 10314302 444166 444172 444177 - 444747 444700 VSP45016 230/1/50 W10303102M 10314102 444164 - - 444169 444744 444699 VSP45036 # 400/3/50 - 10314301 444166 444172 444177 - 444747 444699 VSP50014 230/1/50 10303106 10314105 444164 - - 444169 444744 444702 VSP50034 # 400/3/50 - 10314302 444166 444172 444177 - 444747 444700 VSP50016 230/1/50 W10303102M 10314102 444164 - - 444169 444744 444700 VSP50036 # 400/3/50 - 10314302 444166 444172 444177 - 444747 444700 VSP56014 230/1/50 10303106 10314105 444164 - - 444170 444744 444703 VSP56034 # 400/3/50 - 10314304 444166 444172 444177 - 444747 444702 VSP56016 230/1/50 10314103 10314103 444164 - - 444169 444744 444702 VSP56036 # 400/3/50 - 10314302 444166 444172 444177 - 444747 444700 VSP63034 # 400/3/50 - 10314307 444166 444173 444177 - 444747 444703 VSP63016 230/1/50 10303106 10314105 444164 - - 444169 444744 444702 VSP63036 # 400/3/50 - 10314304 444166 444173 444177 - 444747 444702 VSP71016 230/1/50 10303106 10314105 444164 - - 444170 444744 444703 VSP71036 # 400/3/50 - 10314302 444166 444172 444177 - 444747 444701 VSP71038 # 400/3/50 - 10314302 444166 444172 444177 - 444747 444700 Electronic Voltage controllers may cause motor noise and vibration at lower speeds, transformer or Inverter recommended for noise sensitive applications#All models are supplied with 2 speed delta/star connection motors as standard (Sizes 450 to 630 are 4/6 Pole, size 710 is 6/8 pole) Guards: Some installations may occur where additional safety parts are needed, to ensure safety in operation. For example, the unit may be fitted at the inlet or outlet end of a ducted ventilation system, thereby exposing the impeller/motor to unguarded access. In this event, the installer must fit a safety guard complying to current regulations. These guards are available as an optional extra Where inverters are utilised these must be include Sine filters, as included within our eDemand range of inverters Louvre shutter Fan Dia. Stock Ref 250 LS250 315 LS315 355 LS355 400 LS400 450 LS450 500 LS500 560 LS560 630 LS630 710 LS710 Discharge guard Fan Dia. Stock Ref 250 10502325 315 10502325 355 10502375 400 10502450 450 10502525 500 10502525 560 10502630 630 10502630 710 10502800 NOTE: If a discharge guard is required with a louvre shutter the next size up discharge guard should be selected

234 Sabre Sickle Short Case Fans (VSC) •Swept impeller with Aerofoil blades, winglets and serratedtrailing edge for optimum performance •One shot die cast impeller, dynamically balanced forsmoother operation •Operating temperature up to 70°C •External Rotor Motors on all models for compact efficient design •All models speed controllable•Guards fitted as standard on all models •Thermal Overload Protection for motor protection •Maintenance free sealed for life bearings •2 Year Guarantee The latest generation of the Vent-Axia Sabre ®Sickle Short Case fansincorporate the very latest FE2 Owlett impeller offering improved performance over the previous ranges with up to 7dB(A) reduction in sound and up to 15% improvement in efficiency ensuring the best available fan performance in its class. The advanced blade design is matched to a purpose designed external rotor motor to ensure unrivalled reliability and controllability. Design and Development Using a combination of NASA research into wing performance and winglets, coupled with a study of bird flight has enabled the development of the best available Sickle blade profile. Matching this to a purpose designed close fitting casing ensures best use of this blade technology thereby reducing noise and improving the performance in cased axial fans. Construction The Sabre ®Sickle Short Case fan range share the same case lengths asthe Euroseries Cased axial range making them fully interchangeable and compatible with the full range of Vent-Axia Accessories. The strong and compact short case is constructed from rolled steel plate and protected with a tough, epoxy paint finish. Casing dimensions are to DIN 24151 and flange dimensions are to ISO 6580. Manufacture is controlled to BS EN ISO 9001. The compact motor/impeller unit is robustly supported within the casing by electro welded and epoxy coated steel rod mounting supports for ease of installation and service access. Suitable for all outdoor weather environments. Impellers The impellers incorporate the latest in Sickle blade aerofoil technology to ensure minimum sound and maximum performance. Impellers up to 400mm diameter are moulded from a composite polymer, impellers above this size are Aluminium. The motors and impellers are factory matched, statically and dynamically balanced to ISO 1940 part 1, Quality Class G.6.3. Motors The external rotor motors are specifically designed and styled for this range of fan. Ball bearings are greased for life. Sizes 315 – 710 motors are protected to IP54 against dust and moisture, complying with BS EN 60529. They have ribbed aluminium body castings for efficient cooling with Motor insulation to Class ‘F’ (from -40°C to + 70°C). Speed controlled sizes 450 to 710, 6 & 8 pole motors are only suitable for operating temperatures of up to 40°C. Electrical The Sabre ®Sickle Short Case fan range is available for either singlephase 220-240V 50 Hz capacitor start and run or three phase 380-415V 50Hz. Motors are fitted with Thermal Overload Protection which should be wired into all controller circuits and into starter contactors to prevent motor damage due to overloading / overheating. Speed Control Units are suitable for speed control by either electronic, voltage reduction or frequency inverters where permissible. For optimum efficiency and controllability Vent-Axia recommend the use of the eDemand Inverter Controller to give close control via sensors or manual control. Form of Running Cased mounted fans (ex-stock) are supplied for extract use (Form ‘B’ running). Performance The fan performance is in accordance with tests to ISO 5801.

235 Sound Levels Fan sound levels are measured in a reverberant chamber in accordance with ISO 3744 Part 1. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10 -5 Pa (20 micro-Pascal). The sound power level spectra figures aredB with a reference level of 10 -12Watts (1 pico-watt).To ensure minimum noise levels during speed control, either an auto transformer or eDemand inverter speed control is recommended. Accessories A full range of accessories is available with the Sabre ®Sickle Short Casefans:•Electronic Speed Controllers •Auto Transformer Speed Controllers •eDemand Inverter Speed Control •D.O.L. Starters •Ancillary Packs • Attenuators Fan Dimensions (mm) D F E dia. A dia. B pcd C dia. Stock Ref Kg A B C D E n F VSC31514 7 316 356 382 136.5 9.5 8 65 VSC31534 7 316 356 382 136.5 9.5 8 65 VSC35514 7 356 395 421 136.5 9.5 8 65 VSC35534 7.1 359 395 421 135 9.5 8 65 VSC40014 8.3 400 438 466 155 9.5 12 65 VSC40034 8.3 400 438 466 155 9.5 12 65 VSC45014 15.7 451 487 515 160 9.5 12 65 VSC45034 14.2 451 487 515 160 9.5 12 65 VSC45036 14.2 451 487 515 160 9.5 12 65 VSC50014 16.8 503 541 567 166 9.5 12 65 VSC50034 16.8 503 541 567 166 9.5 12 65 VSC50036 16.8 503 541 567 166 9.5 12 65 VSC56014 29.7 559 605 635 210 11.5 16 75 VSC56034 21.3 559 605 635 210 11.5 16 75 VSC56034 21.3 559 605 635 210 11.5 16 75 VSC63034 35.8 634 674 707 225.5 11.5 16 75 VSC63036 35.8 634 674 707 225.5 11.5 16 75 VSC71036 41.8 711 751 785 260 11.5 16 75 VSC71016 36.8 711 751 785 260 11.5 16 75 VSC71038 41.8 711 751 785 260 11.5 16 75 n = number of holes

236 Performance CurvesPerformance GuideSound Power Level Spectra dB (ref 10 -12Watts) IP Motor F.L.C S.C.Volume m 3 /s @ Pa dB(A) @ Stock Ref Supply Rating kW Amps Amps Poles rpm Curve 0 25 50 75 100 3.0m VSC31514 230/1/50 IP54 0.12 0.54 11.2 4 1360 1 1 Volume m 3 /s 0.65 0.58 0.47 0.29 44 Power Watts 85 93 100 110 VSC31534 400/3/50 IP54 0.12 0.39 1.56 4 1450 1 2 Volume m 3 /s 0.62 0.54 0.47 0.38 47 Power Watts 105 115 117 120 VSC35514 230/1/50 IP54 0.13 0.56 2.24 4 1260 1 3 Volume m 3 /s 0.88 0.78 0.67 0.50 48 Power Watts 145 155 167 181 VSC35534 400/3/50 IP54 0.19 0.4 1.6 4 1390 1 4 Volume m 3 /s 0.98 0.92 0.82 0.67 0.44 48 Power Watts 155 166 174 179 186 VSC40014 230/1/50 IP54 0.24 1.05 4.2 4 1340 1 5 Volume m 3 /s 1.09 1.00 0.92 0.79 0.67 46 Power Watts 183 197 210 224 236 VSC40034 400/3/50 IP54 0.23 0.46 1.84 4 1360 1 6 Volume m 3 /s 1.07 1.01 0.92 0.85 0.74 44 Power Watts 168 184 200 214 228 00.2 0.4 0.6 0.8 1.0 1.2 120 100 80 60 40 20 0 S tatic Pressure (P a) Volume (m 3 /s) 00.2 0.4 0.6 0.8 1.0 1.2 120 100 80 60 40 20 0 S tatic Pressure (P a) Volume (m 3 /s) 2 4 3 5 6 315 to 400 dia. - Pole 41 Phase3 Phase 1 1 Stock Ref 63Hz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 8KHz dB(A) @ 3.0m VSC31514 71 70 65 60 58 59 55 47 44 VSC31534 75 71 62 60 61 62 59 51 47 VSC35514 67 70 67 64 58 60 53 45 48 VSC35534 74 66 61 63 64 63 59 53 48 VSC40014 72 73 66 62 60 59 54 48 46 VSC40034 67 67 61 60 60 59 54 48 44

237 Performance CurvesSound Power Level Spectra dB (ref 10 -12Watts) Performance Guide00.5 1.0 1.5 2.0 2.5 3.0 175 150 125 100 75 50 25 0 S tatic Pressure (P a) Volume (m 3 /s) 0 0.5 1.0 1.5 2.0 2.5 3.0 175 150 125 100 75 50 25 0 S tatic Pressure (P a) Volume (m 3 /s) 3 1 1 2 5 4 7 6 450 to 500 dia. - Pole 4 & 61 Phase3 Phase IP Motor F.L.C S.C.Volume m 3 /s @ Pa dB(A) @ Stock Ref Supply Rating kW Amps Amps Poles rpm Curve 0 25 50 75 100 125 150 175 3.0m VSC45014 230/1/50 IP54 0.6 2.9 11.6 4 1320 1 1 Volume m 3 /s 1.98 1.86 1.72 1.58 1.50 1.31 49 Power Watts 481 490 510 530 537 546 VSC45034 400/3/50 IP54 0.54 1.1 4.4 4 1350 1 2 Volume m 3 /s 2.00 1.89 1.75 1.68 1.53 1.41 49 Power Watts 446 450 485 510 523 532 VSC45036 400/3/50 IP54 0.36 0.66 2.64 6 1020 1 3 Volume m 3 /s 1.623 1.448 1.254 1.056 44 Power Watts 333 351 364 372 VSC50014 230/1/50 IP54 0.72 3.2 12.8 4 1230 1 4 Volume m 3 /s 2.48 2.33 2.14 2.02 1.78 1.54 51 Power Watts 626 649 670 696 710 740 VSC50034 400/3/50 IP54 0.84 1.45 5.8 4 1340 1 5 Volume m 3 /s 2.63 2.50 2.38 2.22 2.08 1.91 1.63 1.28 52 Power Watts 616 653 683 713 739 765 802 829 VSC50036 400/3/50 IP54 0.54 0.96 3.84 6 940 1 6 Volume m 3 /s 2.08 1.89 1.57 1.25 47 Power Watts 472 498 517 530 Stock Ref 63Hz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 8KHz dB(A) @ 3.0m VSC45014 67 69 71 63 63 63 59 53 49 VSC45034 72 70 65 65 64 64 59 53 49 VSC45036 71 66 60 60 60 58 51 43 44 VSC50014 71 75 67 63 67 68 60 52 51 VSC50034 74 72 66 66 68 68 62 56 52 VSC50036 77 77 72 66 64 61 54 47 47

238 Performance CurvesPerformance GuideSound Power Level Spectra dB (ref 10 -12Watts) 01 2 3 4 5 6 7 300 250 200 150 100 50 0 S tatic Pressure (P a) Volume (m 3 /s) 01 2 3 4 5 6 7 300 250 200 150 100 50 0 S tatic Pressure (P a) Volume (m 3 /s) 1 1 2 3 4 5 560 to 630 dia. - Pole 4 & 6 1 Phase3 Phase IP Motor F.L.C S.C.Volume m 3 /s @ Pa dB(A) @ Stock Ref Supply Rating kW Amps Amps Poles rpm Curve 0 25 50 75 100 125 150 175 200 225 250 275 3.0m VSC56014 230/1/50 IP54 1.15 5 20 4 1330 1 1 Volume m 3 /s 3.03 2.92 2.78 2.67 2.50 2.36 2.15 1.96 1.79 62 Power Watts 824 850 910 946 996 1020 1055 1085 1114 VSC56034 400/3/50 IP54 1.05 2.2 8.8 4 1280 1 2 Volume m 3 /s 3.15 3.06 2.89 2.76 2.59 2.39 2.14 1.89 1.52 57 Power Watts 742 770 830 870 910 945 975 1014 1044 VSC56036 400/3/50 IP54 0.58 1.1 4.4 6 880 1 3 Volume m 3 /s 2.47 2.28 2.06 1.67 1.11 51 Power Watts 560 580 605 628 650 VSC63034 400/3/50 IP54 2.4 4.6 18.4 4 1320 1 4 Volume m 3 /s 5.81 5.64 5.50 5.35 5.21 5.00 4.69 4.54 4.23 3.61 3.56 3.40 60 Power Watts 2396 2440 2511 2550 2603 2650 2700 2735 2750 2762 2769 2759 VSC63036 400/3/50 IP54 1.5 2.6 10.4 6 1040 1 5 Volume m 3 /s 4.62 4.39 4.17 3.91 3.63 3.21 2.72 55 Power Watts 1608 1640 1677 1695 1722 1741 1753 Stock Ref 63Hz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 8KHz dB(A) @ 3.0m VSC56014 79 78 74 74 77 77 73 66 62 VSC56034 84 78 76 74 75 74 70 63 57 VSC56036 77 77 67 66 67 66 60 54 51 VSC63034 85 80 77 75 78 77 71 66 60 VSC63036 84 75 71 71 74 71 65 59 55

239 Performance CurvesSound Power Level Spectra dB (ref 10 -12Watts) Performance Guide00.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 150 125 100 75 50 25 0 S tatic Pressure (P a) Volume (m 3 /s) 00.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 150 125 100 75 50 25 0 S tatic Pressure (P a) Volume (m 3 /s) 3 1 1 2 710 dia. - Pole 6 & 81 Phase3 Phase IP Motor F.L.C S.C.Volume m 3 /s @ Pa dB(A) @ Stock Ref Supply Rating kW Amps Amps Poles rpm Curve 0 25 50 75 100 125 150 3.0m VSC71016 230/1/50 IP54 0.95 4.4 17.6 6 850 1 1 Volume m 3 /s 3.859 3.637 3.399 3.056 2.677 2.333 1.695 52 Power Watts 607 666 705 750 808 850 950 VSC71036 400/3/50 IP54 0.94 1.7 6.8 6 900 1 2 Volume m 3 /s 4.042 3.861 3.611 3.194 2.919 2.608 1.994 49 Power Watts 560 590 670 768 813 861 931 VSC71038 400/3/50 IP54 0.62 1.05 4.2 8 690 1 3 Volume m 3 /s 3.512 3.115 2.694 1.936 45 Power Watts 451 510 560 615 Stock Ref 63Hz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 8KHz dB(A) @ 3.0m VSC71016 81 81 72 69 70 67 61 57 52 VSC71036 69 69 68 67 68 65 59 52 49 VSC71038 66 63 63 65 62 59 50 44 45

240 Accessories Dimensions (mm) 150 a Ø Coupling Flange Mounting Feet (Pack of 2) Stock Ref a b c d Øe f g h i MFZ315 315 40 265 200 10 20 71 178 166 MFZ355 350 40 300 225 10 20 81.5 197.5 186 MFZ400 250 40 220 250 10 20 78 219 205 MFZ450 275 40 240 275 10 20 82 243.5 230 MFZ500 315 50 280 315 1 25 100 270.5 255 MFZ560 355 50 320 355 12 25 97 302.5 285 MFZ630 400 50 360 400 12 25 108.5 337 320 MFZ710 465 50 415 450 12 25 118.5 375.5 362 Stock Ref Dia WGZ315 375 WGZ355 414 WGZ400 461 WGZ450 506 WGZ500 560 WGZ560 626.5 WGZ630 695.5 WGZ710 772.5 Stock Ref Øa b Øc Ød Øe Øfn CFZ315 313 40 356 382 10 319 8 CFZ355 353 40 395 421 10 359 8 CFZ400 398 45 438 466 10 404 12 CFZ450 448 45 487 515 10 454 12 CFZ500 498 45 541 567 10 504 12 CFZ560 558 45 605 635 12 564 16 CFZ630 628 45 674 707 12 634 16 CFZ710 708 50 751 785 12 714 16 Anti-Vibration Mounts (Pack of 4) - All Models Stock Ref a Øb c d e Øf n load kg68MP033G 27 37 54 67 18.5 7 M8 23 Flexible Connection Inlet Wire Guard ‘K’ factor loss 0.25 For more information on the ‘K’ factor, refer to General Information Section

241 Accessories Stock Ref Supply ElectronicController 5 Step AutoTransformer eDemandVoltage eDemand 3phInverter eDemand 1phin 3ph outInverter eDemand 1PhInverter D.O.L StarterOverload VSC31514 230/1/50 W10303102M 10314102 444164 - - 444169 444744 444699 VSC31534 400/3/50 - 10314301 444166 444172 444177 - 444747 444699 VSC35514 230/1/50 W10303102M 10314102 444164 - - 444169 444744 444699 VSC35534 400/3/50 - 10314301 444166 444172 444177 - 444747 444698 VSC40014 230/1/50 W10303102M 10314102 444164 - - 444169 444744 444700 VSC40034 400/3/50 - 10314301 444166 444172 444177 - 444747 444698 VSC45014 230/1/50 10303103 10314103 444164 - - 444169 444744 444702 VSC45034 # 400/3/50 - 10314302 444166 444172 444177 - 444747 444700 VSC45036 # 400/3/50 - 10314301 444166 444172 444177 - 444747 444699 VSC50014 230/1/50 10303106 10314105 444164 - - 444169 444744 444702 VSC50034 # 400/3/50 - 10314302 444166 444172 444177 - 444747 444700 VSC50036 # 400/3/50 - 10314301 444166 444172 444177 - 444747 444700 VSC56014 230/1/50 10303106 10314105 444164 - - 444170 444744 444703 VSC56034 400/3/50 - 10314304 444166 444173 444177 - 444747 444701 VSC63034 # 400/3/50 - 10314304 444166 444173 444177 - 444747 444703 VSC63036 # 400/3/50 - 10314304 444166 444173 444177 - 444747 444702 VSC71036 # 400/3/50 - 10314302 444166 444172 444177 - 444747 444701 VSC71016 230/1/50 10303106 10314105 444164 - - 444170 444744 444703 VSC71038 # 400/3/50 - 10314302 444166 444172 444177 - 444747 444700 Electronic Voltage controllers may cause motor noise and vibration at lower speeds, transformer or Inverter recommended for noise sensitive applications #All models are supplied with 2 speed delta/star connection motors, as standard. (Sizes 450 to 630 are 4/6 Pole) Guards: Some installations may occur where additional safety parts are needed, to ensure safety in operation. For example, the unit may be fitted at the inlet or outlet end of a ducted ventilation system, thereby exposing the impeller/motor to unguarded access. In this event, the installer must fit a safety guard complying to current regulations. These guards are available as an optional extra.Where inverters are utilised these must be include Sine filters, as included within our eDemand range of inverters. Fan Dia Mounting Feet Wire (pack of 2) Stock Ref Inlet Wire Guard Stock Ref Coupling Flange Stock Ref Axial Ancillary Pack Stock Ref Cased AxialAttenuator Stock Ref Cased Axial Attenuator Pod 1D Stock Ref Cased AxialPod 2D Stock Ref 315 MFZ315 WGZ315 CFZ315 APZ315 ACZ3151D ACZ3151DP ACZ3152DP 355 MFZ355 WGZ355 CFZ355 APZ355 ACZ3551D ACZ3551DP ACZ3552DP 400 MFZ400 WGZ400 CFZ400 APZ400 ACZ4001D ACZ4001DP ACZ4002DP 450 MFZ450 WGZ450 CFZ450 APZ450 ACZ4501D ACZ4501DP ACZ4502DP 500 MFZ500 WGZ500 CFZ500 APZ500 ACZ5001D ACZ5001DP ACZ5002DP 560 MFZ560 WGZ560 CFZ560 APZ560 ACZ5601D ACZ5601DP ACZ5602DP 630 MFZ630 WGZ630 CFZ630 APZ630 ACZ6301D ACZ6301DP ACZ6302DP 710 MFZ710 WGZ710 CFZ710 APZ710 ACZ7101D ACZ7101DP ACZ7102DP

242 Long Case Axial Fans (LCA) •Motors protected to IP55 •Motor insulation Class ‘F’ •Maximum ambient temp. 54˚C •Speed controllable via transformer or inverter•IP55 terminal box •Adjustable factory set die cast aluminium impeller •Suitable for relative humidity levels up to 95% RH •Manufactured to BS EN ISO 9001 •Performance tested to BS 848 parts 1, 2 and ISO 5801 •2 Year GuaranteeThe Long Case Axial range of fans incorporates manually adjustable pitch impellers which provide a comprehensive range of duties offering high performance and pressure characteristics. Available in thirteen sizes ranging from 250 to 1250mm diameter and performances from 0.24m 3 /s to 36m 3 /s with pressure development upto 1500Pa. The casing is constructed from rolled steel plate complete with flanges and protected with a tough, galvanised finish. The Long Case Axial Fan range has a number of accessories available which include: Axial Ancillary Pack, Attenuators, Mounting Feet, Wire Inlet Guard, Coupling Flange and Speed Controllers. Sound Levels All measurements of the sound that the fans generate have been taken strictly in accordance with BS 848 part 2, test method 1. Published sound power level spectra figures are dBW with a reference of 10 -12Watts(1 Pico watt). Motors The motors are specially selected for optimum performance and efficiency. Ball bearings are greased for life and allow the fan to be installed at any angle. Suitable for continuous operation in relative humidity up to 95% Motors are protected to IP55 against dust and water jets complying withBS EN 60529. They have ribbed aluminium body castings for efficient cooling. Motor insulation is Class ‘F’ (from -35˚C to +54˚C). Star/delta starting is recommended for motor output above 7.5kW. Axial Impellers Impeller blades are clamped in a split cast aluminium hub, with a keywayed mild steel insert enabling positive locking of the impeller assembly to the motor shaft, this also allows manual adjustment of the pitch angle giving a wide selection of performance details. Terminal Box Rated to IP55, protected against dust and water jets from any angle, allowing outside applications. Declaration of Conformity All models are supplied with an EC Declaration of Conformity as defined by the EC Council Directive on Machinery 98/37/EC. This declares that all the models, on the basis of their design and construction in the form brought onto the market by Vent-Axia, are in accordance with the Machinery Directive. Electrical Single phase 220-240V 50 Hz permanent capacitor. Three phase 380-415V 50Hz. Protection of the motor must be provided by an overload current sensing device (eg. D.O.L Starter or Star/Delta starter where appropriate) or the guarantee will be invalidated. All models are available with 4 pole motors for 250 up to 1250mm diameter with additional 2 pole motors available from 250 up to 630mm diameter. All units are manufactured to order with 10 working days delivery (uk mainland).

243 Fan Dimensions (mm) Model No. Pole Phase Pitch Angle A B C D E F G Max Weight kg LCA25 2 & 4 1 & 3 25-40 250 300 295 335 8 10 200 15 LCA31 2 & 4 1 & 3 10-38 315 420 355 385 8 10 224 23 LCA35 2 & 4 1 & 3 10-38 355 420 395 425 8 10 250 25 LCA40 2 & 4 1 & 3 10-38 400 435 450 480 8 12 280 38 LCA45 2 & 4 1 & 3 10-40 450 435 500 530 8 12 315 49 LCA50 2 3 10-31 500 565 560 590 12 12 315 86 LCA50 2 3 32-40 500 565 560 590 12 12 315 86 LCA50 4 1 & 3 10-40 500 565 560 590 12 12 315 86 LCA56 2 3 10-15 560 565 620 650 12 12 355 94 LCA56 2 3 16-24 560 565 620 650 12 12 355 94 LCA56 4 1 & 3 10-40 560 565 620 650 12 12 355 94 LCA63 2 3 10-22 630 565 690 720 12 12 400 96 LCA63 4 1 10-26 630 565 690 720 12 12 400 96 LCA63 4 3 10-40 630 565 690 720 12 12 400 96 LCA71 4 3 10-36 710 565 770 800 16 12 435 92 LCA80 4 3 10-20 800 565 860 890 16 12 480 131 LCA80 4 3 21-34 800 565 860 890 16 12 480 131 LCA90 4 3 10-26 900 565 970 1038 16 14 535 214 LCA90 4 3 28-40 900 700 970 1038 16 14 535 214 LCA100 4 3 10-22 1000 565 1070 1138 16 14 555 274 LCA100 4 3 24-32 1000 700 1070 1138 16 14 555 274 LCA100 4 3 34-40 1000 790 1070 1138 16 14 555 274 LCA125 4 3 20-34 1250 950 1320 1390 20 15 868 903

244 1 40° 1 35° 1 30° 1 25° LCA25 - 1 & 3 Phase - 2 Pole Performance CurvesPerformance Guide1 Phase3 PhaseIP Curve m 3 /s at Pa Motor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 50 100 150 200 250kW@3m 250 LCA251225 LCA253225 2 2800 IP55 1 25° 0.43 0.41 0.38 0.35 0.31 0.24 0.37 58 250 LCA251230 LCA253230 2 2800 IP55 1 30° 0.54 0.51 0.47 0.42 0.37 0.29 0.37 57 250 LCA251235 LCA253235 2 2800 IP55 1 35° 0.64 0.6 0.56 0.5 0.44 0.37 0.37 58 250 LCA251240 LCA253240 2 2800 IP55 1 40° 0.72 0.67 0.62 0.56 0.48 0.37 59 Sound Power Level Spectra dB (ref 10 -12Watts) 1 Phase Stock 3 Phase Dia. Stock Ref Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 250 LCA251225 LCA253225 2 Inlet/Outlet 73 74 82 75 73 70 67 64 58 250 LCA251230 LCA253230 2 Inlet/Outlet 72 73 81 74 72 69 66 63 57 250 LCA251235 LCA253235 2 Inlet/Outlet 73 74 82 75 73 70 67 64 58 250 LCA251240 LCA253240 2 Inlet/Outlet 74 75 83 76 74 71 68 65 59

245 1 38° 1 36° 1 34° 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° LCA31 - 1 & 3 Phase - 2 Pole Performance Guide1 Phase3 PhaseCurve m 3 /s at Pa Motor dBA Dia. Stock Ref Stock Ref Poles rpmIP RatingRef 0 100 200 300 400kW@3m 315 LCA311210 LCA313210 2 2800 IP55 1 10° 0.58 0.52 0.43 0.27 0.08 0.37 65 315 LCA311212 LCA313212 2 2800 IP55 1 12° 0.63 0.57 0.48 0.33 0.11 0.37 65 315 LCA311214 LCA313214 2 2800 IP55 1 14° 0.69 0.63 0.54 0.38 0.13 0.37 65 315 LCA311216 LCA313216 2 2800 IP55 1 16° 0.76 0.69 0.6 0.43 0.16 0.37 63 315 LCA311218 LCA313218 2 2800 IP55 1 18° 0.83 0.76 0.65 0.48 0.19 0.37 61 315 LCA311220 LCA313220 2 2800 IP55 1 20° 0.9 0.82 0.71 0.53 0.21 0.37 61 315 LCA311222 LCA313222 2 2800 IP55 1 22° 0.96 0.87 0.76 0.58 0.37 62 315 LCA311224 LCA313224 2 2800 IP55 1 24° 1 0.92 0.8 0.62 0.37 63 315 LCA311226 LCA313226 2 2800 IP55 1 26° 1.05 0.97 0.85 0.65 0.55 63 315 LCA311228 LCA313228 2 2800 IP55 1 28° 1.1 1.01 0.89 0.69 0.55 63 315 LCA311230 LCA313230 2 2800 IP55 1 30° 1.16 1.06 0.94 0.72 0.55 64 315 LCA311232 LCA313232 2 2800 IP55 1 32° 1.22 1.11 0.98 0.75 0.55 66 315 LCA311234 LCA313234 2 2800 IP55 1 34° 1.28 1.16 1.01 0.78 0.75 66 315 LCA311236 LCA313236 2 2800 IP55 1 36° 1.33 1.2 1.04 0.79 0.75 66 315 LCA311238 LCA313238 2 2800 IP55 1 38° 1.37 1.23 1.06 0.79 0.75 66 Sound Power Level Spectra dB (ref 10 -12Watts) 1 Phase 3 Phase Dia. Stock Ref Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 315 LCA311210 LCA313210 2 Inlet/Outlet 83 82 82 79 81 80 76 68 65 315 LCA311212 LCA313212 2 Inlet/Outlet 83 82 82 79 81 80 76 68 65 315 LCA311214 LCA313214 2 Inlet/Outlet 83 82 82 79 81 80 76 68 65 315 LCA311216 LCA313216 2 Inlet/Outlet 81 80 80 77 79 78 74 66 63 315 LCA311218 LCA313218 2 Inlet/Outlet 79 78 78 75 77 76 72 64 61 315 LCA311220 LCA313220 2 Inlet/Outlet 79 78 78 75 77 76 72 64 61 315 LCA311222 LCA313222 2 Inlet/Outlet 80 79 79 76 78 77 73 65 62 315 LCA311224 LCA313224 2 Inlet/Outlet 81 80 80 77 79 78 74 66 63 315 LCA311226 LCA313226 2 Inlet/Outlet 81 80 80 77 79 78 74 66 63 315 LCA311228 LCA313228 2 Inlet/Outlet 81 80 80 77 79 78 74 66 63 315 LCA311230 LCA313230 2 Inlet/Outlet 82 81 81 78 80 79 75 67 64 315 LCA311232 LCA313232 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 315 LCA311234 LCA313234 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 315 LCA311236 LCA313236 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 315 LCA311238 LCA313238 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 Performance Curves

246 1 38° 1 36° 1 34° 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° LCA35 - 1 & 3 Phase - 2 Pole Performance CurvesPerformance Guide1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 100 200 300 400 500kW@3m 355 LCA351210 LCA353210 2 2800 IP55 1 10° 0.84 0.76 0.67 0.54 0.34 0.13 0.37 65 355 LCA351212 LCA353212 2 2800 IP55 1 12° 0.91 0.84 0.75 0.62 0.42 0.17 0.37 66 355 LCA351214 LCA353214 2 2800 IP55 1 14° 0.99 0.92 0.83 0.7 0.49 0.21 0.55 66 355 LCA351216 LCA353216 2 2800 IP55 1 16° 1.08 1.01 0.92 0.78 0.56 0.25 0.55 66 355 LCA351218 LCA353218 2 2800 IP55 1 18° 1.19 1.1 1 0.86 0.64 0.29 0.55 66 355 LCA351220 LCA353220 2 2800 IP55 1 20° 1.29 1.2 1.09 0.93 0.7 0.32 0.55 66 355 LCA351222 LCA353222 2 2800 IP55 1 22° 1.37 1.28 1.16 1 0.76 0.75 61 355 LCA351224 LCA353224 2 2800 IP55 1 24° 1.44 1.34 1.23 1.07 0.81 0.75 62 355 LCA351226 LCA353226 2 2800 IP55 1 26° 1.51 1.41 1.29 1.13 0.86 0.75 63 355 LCA351228 LCA353228 2 2800 IP55 1 28° 1.58 1.48 1.36 1.19 0.9 1.1 63 355 LCA351230 LCA353230 2 2800 IP55 1 30° 1.66 1.55 1.42 1.25 0.93 1.1 64 355 LCA351232 LCA353232 2 2800 IP55 1 32° 1.75 1.63 1.49 1.31 0.97 1.1 64 355 LCA351234 LCA353234 2 2800 IP55 1 34° 1.84 1.7 1.55 1.35 1 1.1 64 355 LCA351236 LCA353236 2 2800 IP55 1 36° 1.9 1.76 1.59 1.39 1.02 1.5 64 355 LCA351238 LCA353238 2 2800 IP55 1 38° 1.96 1.8 1.63 1.41 1.5 64 Sound Power Level Spectra dB (ref 10 -12Watts) 1 Phase 3 Phase Dia. Stock Ref Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 355 LCA351210 LCA353210 2 Inlet/Outlet 83 82 82 79 81 80 76 68 65 355 LCA351212 LCA353212 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 355 LCA351214 LCA353214 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 355 LCA351216 LCA353216 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 355 LCA351218 LCA353218 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 355 LCA351220 LCA353220 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 355 LCA351222 LCA353222 2 Inlet/Outlet 79 78 78 75 77 76 72 64 61 355 LCA351224 LCA353224 2 Inlet/Outlet 80 79 79 76 78 77 73 65 62 355 LCA351226 LCA353226 2 Inlet/Outlet 81 80 80 77 79 78 74 66 63 355 LCA351228 LCA353228 2 Inlet/Outlet 81 80 80 77 79 78 74 66 63 355 LCA351230 LCA353230 2 Inlet/Outlet 82 81 81 78 80 79 75 67 64 355 LCA351232 LCA353232 2 Inlet/Outlet 82 81 81 78 80 79 75 67 64 355 LCA351234 LCA353234 2 Inlet/Outlet 82 81 81 78 80 79 75 67 64 355 LCA351236 LCA353236 2 Inlet/Outlet 82 81 81 78 80 79 75 67 64 355 LCA351238 LCA353238 2 Inlet/Outlet 82 81 81 78 80 79 75 67 64

247 1 40° 1 38° 1 36° 1 34° 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° LCA40 - 1 & 3 Phase - 2 Pole Performance CurvesPerformance Guide1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 100 200 300 400 500kW@3m 400 LCA401210 LCA403210 2 2800 IP55 1 10° 1.17 1.08 0.97 0.8 0.53 0.23 0.55 71 400 LCA401212 LCA403212 2 2800 IP55 1 12° 1.29 1.2 1.09 0.92 0.66 0.33 0.55 71 400 LCA401214 LCA403214 2 2800 IP55 1 14° 1.42 1.32 1.2 1.03 0.78 0.42 0.75 71 400 LCA401216 LCA403216 2 2800 IP55 1 16° 1.55 1.45 1.32 1.15 0.9 0.75 71 400 LCA401218 LCA403218 2 2800 IP55 1 18° 1.68 1.57 1.44 1.27 1.01 0.75 71 400 LCA401220 LCA403220 2 2800 IP55 1 20° 1.81 1.69 1.55 1.37 1.11 1.1 71 400 LCA401222 LCA403222 2 2800 IP55 1 22° 1.93 1.8 1.65 1.46 1.2 1.1 66 400 LCA401224 LCA403224 2 2800 IP55 1 24° 2.04 1.9 1.74 1.54 1.28 1.1 66 400 LCA401226 LCA403226 2 2800 IP55 1 26° 2.15 2 1.83 1.63 1.37 1.1 67 400 LCA401228 LCA403228 2 2800 IP55 1 28° 2.27 2.11 1.93 1.72 1.45 1.5 68 400 LCA401230 LCA403230 2 2800 IP55 1 30° 2.38 2.22 2.03 1.8 1.52 1.5 68 400 LCA401232 LCA403232 2 2800 IP55 1 32° 2.49 2.31 2.11 1.88 1.59 1.5 68 400 - LCA403234 2 2800 IP55 1 34° 2.59 2.4 2.19 1.94 1.64 2.2 67 400 - LCA403236 2 2800 IP55 1 36° 2.67 2.47 2.25 1.99 1.67 2.2 66 400 - LCA403238 2 2800 IP55 1 38° 2.73 2.53 2.31 2.04 1.69 2.2 66 400 - LCA403240 2 2800 IP55 1 40° 2.78 2.59 2.36 2.08 1.69 3 66 Sound Power Level Spectra dB (ref 10 -12Watts) Dia. 1 PhaseStockRef 3Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 400 LCA401210 LCA403210 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 400 LCA401212 LCA403212 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 400 LCA401214 LCA403214 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 400 LCA401216 LCA403216 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 400 LCA401218 LCA403218 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 400 LCA401220 LCA403220 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 400 LCA401222 LCA403222 2 Inlet/Outlet 84 81 84 81 82 79 76 69 66 400 LCA401224 LCA403224 2 Inlet/Outlet 84 81 84 81 82 79 76 69 66 400 LCA401226 LCA403226 2 Inlet/Outlet 85 82 85 82 83 80 77 70 67 400 LCA401228 LCA403228 2 Inlet/Outlet 86 83 86 83 84 81 78 71 68 400 LCA401230 LCA403230 2 Inlet/Outlet 86 83 86 83 84 81 78 71 68 400 LCA401232 LCA403232 2 Inlet/Outlet 86 83 86 83 84 81 78 71 68 400 - LCA403234 2 Inlet/Outlet 85 82 85 82 83 80 77 70 67 400 - LCA403236 2 Inlet/Outlet 84 81 84 81 82 79 76 69 66 400 - LCA403238 2 Inlet/Outlet 84 81 84 81 82 79 76 69 66 400 - LCA403240 2 Inlet/Outlet 84 81 84 81 82 79 76 69 66

248 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° LCA45 - 3 Phase - 2 Pole Performance Curves3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 100 200 300 400 500 600 700kW@3m 450 LCA453210 2 2880 IP55 1 10° 1.72 1.62 1.51 1.37 1.17 0.89 0.56 0.25 1.1 74 450 LCA453212 2 2880 IP55 1 12° 1.89 1.79 1.68 1.54 1.34 1.08 0.73 0.37 1.1 73 450 LCA453214 2 2880 IP55 1 14° 2.08 1.97 1.85 1.7 1.51 1.26 0.9 0.5 1.5 72 450 LCA453216 2 2880 IP55 1 16° 2.27 2.16 2.03 1.88 1.69 1.43 1.5 71 450 LCA453218 2 2880 IP55 1 18° 2.47 2.35 2.21 2.05 1.86 1.59 1.2 1.5 70 450 LCA453220 2 2880 IP55 1 20° 2.65 2.53 2.38 2.21 2.01 1.74 1.35 2.2 70 450 LCA453222 2 2880 IP55 1 22° 2.82 2.69 2.53 2.35 2.14 1.87 1.49 2.2 70 450 LCA453224 2 2880 IP55 1 24° 2.99 2.84 2.67 2.48 2.26 1.99 1.62 2.2 70 450 LCA453226 2 2880 IP55 1 26° 3.15 2.99 2.82 2.61 2.38 2.11 1.75 2.2 70 450 LCA453228 2 2880 IP55 1 28° 3.32 3.15 2.96 2.75 2.51 2.23 1.86 3 70 450 LCA453230 2 2880 IP55 1 30° 3.49 3.31 3.11 2.89 2.64 2.35 1.97 3 70 450 LCA453232 2 2880 IP55 1 32° 3.65 3.45 3.24 3.01 2.74 2.44 2.08 3 70 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuideDia. 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 450 LCA453210 2 Inlet/Outlet 92 89 92 89 90 87 84 77 74 450 LCA453212 2 Inlet/Outlet 91 88 91 88 89 86 83 76 73 450 LCA453214 2 Inlet/Outlet 90 87 90 87 88 85 82 75 72 450 LCA453216 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 450 LCA453218 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 LCA453220 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 LCA453222 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 LCA453224 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 LCA453226 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 LCA453228 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 LCA453230 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 LCA453232 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70

249 1 10° 1 12° 1 14° 1 16° 1 18° 1 20° 1 22° 1 24° 1 26° 1 28° 1 30° 1 32° 1 34° 1 36° 1 38° 1 40° LCA50 - 3 Phase - 2 Pole 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 100 200 300 400 500 600 700kW@3m 500 LCA503210 2 2880 IP55 1 10° 2.34 2.19 2.02 1.82 1.56 1.23 0.77 0.25 1.5 74 500 LCA503212 2 2880 IP55 1 12° 2.64 2.48 2.3 2.09 1.83 1.51 1.06 0.46 1.5 73 500 LCA503214 2 2880 IP55 1 14° 2.93 2.76 2.57 2.36 2.1 1.77 1.33 0.68 2.2 72 500 LCA503216 2 2880 IP55 1 16° 3.21 3.04 2.84 2.62 2.35 2.03 1.58 2.2 71 500 LCA503218 2 2880 IP55 1 18° 3.48 3.29 3.09 2.86 2.59 2.26 1.8 2.2 71 500 LCA503220 2 2880 IP55 1 20° 3.73 3.54 3.33 3.09 2.82 2.48 2.01 3 71 500 LCA503222 2 2880 IP55 1 22° 3.96 3.77 3.55 3.31 3.03 2.69 2.21 3 71 500 LCA503224 2 2880 IP55 1 24° 4.19 3.99 3.77 3.52 3.24 2.88 2.4 3 71 500 LCA503226 2 2880 IP55 1 26° 4.42 4.21 3.99 3.73 3.44 3.07 2.58 4 71 500 LCA503228 2 2880 IP55 1 28° 4.66 4.45 4.21 3.94 3.63 3.25 2.74 4 72 500 LCA503230 2 2880 IP55 1 30° 4.9 4.67 4.41 4.13 3.8 3.41 2.88 4 72 500 LCA503232 2 2880 IP55 1 32° 5.12 4.86 4.58 4.28 3.95 3.55 3 5.5 72 500 LCA503234 2 2880 IP55 1 34° 5.3 5.02 4.73 4.41 4.07 3.66 3.08 5.5 72 500 LCA503236 2 2880 IP55 1 36° 5.45 5.16 4.85 4.52 4.15 3.7 5.5 72 500 LCA503238 2 2880 IP55 1 38° 5.55 5.26 4.95 4.61 4.21 3.69 7.5 72 500 LCA503240 2 2880 IP55 1 40° 5.64 5.36 5.05 4.69 4.25 7.5 72 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance CurvesDia. Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 500 LCA503210 2 Inlet/Outlet 93 84 91 91 91 87 85 78 74 500 LCA503212 2 Inlet/Outlet 92 83 90 90 90 86 84 77 73 500 LCA503214 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 LCA503216 2 Inlet/Outlet 90 81 88 88 88 84 82 75 71 500 LCA503218 2 Inlet/Outlet 90 81 88 88 88 84 82 75 71 500 LCA503220 2 Inlet/Outlet 90 81 88 88 88 84 82 75 71 500 LCA503222 2 Inlet/Outlet 90 81 88 88 88 84 82 75 71 500 LCA503224 2 Inlet/Outlet 90 81 88 88 88 84 82 75 71 500 LCA503226 2 Inlet/Outlet 90 81 88 88 88 84 82 75 71 500 LCA503228 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 LCA503230 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 LCA503232 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 LCA503234 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 LCA503236 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 LCA503238 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 LCA503240 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72

250 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° LCA56 - 3 Phase - 2 Pole 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 200 400 600 800 1000 1200 1400kW@3m 560 LCA563210 2 2880 IP55 1 10° 3.01 2.8 2.56 2.25 1.85 1.36 0.79 0.09 4 79 560 LCA563212 2 2880 IP55 1 12° 3.44 3.2 2.93 2.59 2.18 1.69 1.11 0.35 4 79 560 LCA563214 2 2880 IP55 1 14° 3.87 3.61 3.31 2.95 2.52 1.99 1.37 0.53 4 79 560 LCA563216 2 2880 IP55 1 16° 4.3 4.04 3.73 3.36 2.88 2.27 5.5 79 560 LCA563218 2 2880 IP55 1 18° 4.73 4.48 4.18 3.79 3.25 2.53 5.5 79 560 LCA563220 2 2880 IP55 1 20° 5.15 4.91 4.61 4.21 3.65 2.83 7.5 79 560 LCA563222 2 2880 IP55 1 22° 5.54 5.3 5 4.61 4.05 3.21 7.5 79 560 LCA563224 2 2880 IP55 1 24° 5.94 5.67 5.36 4.98 4.45 3.62 7.5 79 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve Dia. 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 560 LCA563210 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 LCA563212 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 LCA563214 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 LCA563216 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 LCA563218 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 LCA563220 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 LCA563222 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 LCA563224 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 LCA563226 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79

251 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° LCA63 - 3 Phase - 2 Pole Performance Curve 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 200 400 600 800 1000 1200 1400kW@3m 630 LCA633210 2 2940 IP55 1 10° 4.51 4.2 3.87 3.47 3.01 2.44 1.7 0.72 5.5 84 630 LCA633212 2 2940 IP55 1 12° 5 4.7 4.36 3.96 3.48 2.9 2.16 1.17 5.5 84 630 LCA633214 2 2940 IP55 1 14° 5.53 5.22 4.88 4.48 3.98 3.38 2.61 1.6 7.5 84 630 LCA633216 2 2940 IP55 1 16° 6.15 5.84 5.48 5.06 4.54 3.89 7.5 84 630 LCA633218 2 2940 IP55 1 18° 6.81 6.5 6.13 5.68 5.14 4.44 11 84 630 LCA633220 2 2940 IP55 1 20° 7.46 7.12 6.74 6.28 5.72 4.98 11 84 630 LCA633222 2 2940 IP55 1 22° 8.01 7.67 7.27 6.82 6.25 5.51 11 84 630 LCA633224 2 2940 IP55 1 24° 8.53 8.17 7.76 7.3 6.74 6 15 84 630 LCA633226 2 2940 IP55 1 26° 9.08 8.7 8.27 7.79 7.22 6.47 5.41 15 84 630 LCA633228 2 2940 IP55 1 28° 9.67 9.26 8.81 8.3 7.69 6.92 5.85 15 84 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuideDia. Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 630 LCA633210 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 630 LCA633212 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 630 LCA633214 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 630 LCA633216 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 630 LCA633218 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 630 LCA633220 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 630 LCA633222 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 630 LCA633224 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 630 LCA633226 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 630 LCA633228 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84

252 1 40° 1 35° 1 30° 1 25° LCA25 - 1 & 3 Phase - 4 Pole Performance Guide1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 10 20 30 40 50 60kW@3m 250 LCA251425 LCA253425 4 1400 IP55 1 25° 0.22 0.21 0.2 0.18 0.17 0.15 0.13 0.25 46 250 LCA251430 LCA253430 4 1400 IP55 1 30° 0.27 0.26 0.24 0.23 0.21 0.19 0.15 0.25 45 250 LCA251435 LCA253435 4 1400 IP55 1 35° 0.32 0.3 0.29 0.27 0.25 0.22 0.19 0.25 46 250 LCA251440 LCA253440 4 1400 IP55 1 40° 0.36 0.34 0.32 0.3 0.27 0.24 0.25 46 Sound Power Level Spectra dB (ref 10 -12Watts)Dia. 1 PhaseStock Ref 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 250 LCA251425 LCA253425 4 Inlet/Outlet 61 68 64 63 61 58 55 52 46 250 LCA251430 LCA253430 4 Inlet/Outlet 60 67 63 62 60 57 54 51 45 250 LCA251435 LCA253435 4 Inlet/Outlet 61 68 64 63 61 58 55 52 46 250 LCA251440 LCA253440 4 Inlet/Outlet 61 68 64 63 61 58 55 52 46 Performance Curve

253 LCA31 - 1 & 3 Phase - 4 Pole 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° Performance Curve Performance Guide1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 20 40 60 80 100kW@3m 315 LCA311410 LCA313410 4 1400 IP55 1 10° 0.29 0.27 0.23 0.19 0.12 0.04 0.25 49 315 LCA311412 LCA313412 4 1400 IP55 1 12° 0.32 0.29 0.26 0.22 0.14 0.05 0.25 49 315 LCA311414 LCA313414 4 1400 IP55 1 14° 0.35 0.32 0.29 0.24 0.17 0.07 0.25 49 315 LCA311416 LCA313416 4 1400 IP55 1 16° 0.38 0.35 0.32 0.27 0.19 0.08 0.25 44 315 LCA311418 LCA313418 4 1400 IP55 1 18° 0.42 0.39 0.35 0.3 0.22 0.09 0.25 44 315 LCA311420 LCA313420 4 1400 IP55 1 20° 0.45 0.42 0.38 0.32 0.24 0.11 0.25 44 315 LCA311422 LCA313422 4 1400 IP55 1 22° 0.48 0.45 0.4 0.35 0.26 0.25 44 315 LCA311424 LCA313424 4 1400 IP55 1 24° 0.5 0.47 0.43 0.37 0.28 0.25 46 315 LCA311426 LCA313426 4 1400 IP55 1 26° 0.53 0.49 0.45 0.39 0.29 0.25 46 315 LCA311428 LCA313428 4 1400 IP55 1 28° 0.55 0.52 0.47 0.41 0.31 0.25 46 315 LCA311430 LCA313430 4 1400 IP55 1 30° 0.58 0.54 0.5 0.43 0.32 0.25 46 315 LCA311432 LCA313432 4 1400 IP55 1 32° 0.61 0.57 0.52 0.45 0.32 0.25 48 315 LCA311434 LCA313434 4 1400 IP55 1 34° 0.64 0.59 0.54 0.47 0.33 0.25 48 315 LCA311436 LCA313436 4 1400 IP55 1 36° 0.67 0.61 0.56 0.48 0.25 48 315 LCA311438 LCA313438 4 1400 IP55 1 38° 0.68 0.63 0.57 0.49 0.25 48 Sound Power Level Spectra dB (ref 10 -12Watts)Dia. 1 PhaseStock Ref 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 315 LCA311410 LCA313410 4 Inlet/Outlet 66 69 67 64 65 63 58 48 49 315 LCA311412 LCA313412 4 Inlet/Outlet 66 69 67 64 65 63 58 48 49 315 LCA311414 LCA313414 4 Inlet/Outlet 66 69 67 64 65 63 58 48 49 315 LCA311416 LCA313416 4 Inlet/Outlet 61 64 62 59 60 58 53 43 44 315 LCA311418 LCA313418 4 Inlet/Outlet 61 64 62 59 60 58 53 43 44 315 LCA311420 LCA313420 4 Inlet/Outlet 61 64 62 59 60 58 53 43 44 315 LCA311422 LCA313422 4 Inlet/Outlet 61 64 62 59 60 58 53 43 44 315 LCA311424 LCA313424 4 Inlet/Outlet 63 66 64 61 62 60 55 45 46 315 LCA311426 LCA313426 4 Inlet/Outlet 63 66 64 61 62 60 55 45 46 315 LCA311428 LCA313428 4 Inlet/Outlet 63 66 64 61 62 60 55 45 46 315 LCA311430 LCA313430 4 Inlet/Outlet 63 66 64 61 62 60 55 45 46 315 LCA311432 LCA313432 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48 315 LCA311434 LCA313434 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48 315 LCA311436 LCA313436 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48 315 LCA311438 LCA313438 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48 315 LCA311440 LCA313440 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48

254 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° LCA35- 1 & 3 Phase - 4 Pole Performance Guide1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 20 40 60 80 100 120 140kW@3m 355 LCA351410 LCA353410 4 1400 IP55 1 10° 0.42 0.39 0.36 0.31 0.25 0.17 0.08 0.01 0.25 50 355 LCA351412 LCA353412 4 1400 IP55 1 12° 0.45 0.43 0.39 0.35 0.29 0.21 0.11 0.02 0.25 50 355 LCA351414 LCA353414 4 1400 IP55 1 14° 0.49 0.47 0.43 0.39 0.33 0.25 0.13 0.03 0.25 50 355 LCA351416 LCA353416 4 1400 IP55 1 16° 0.54 0.51 0.48 0.43 0.37 0.28 0.16 0.04 0.25 50 355 LCA351418 LCA353418 4 1400 IP55 1 18° 0.6 0.56 0.52 0.48 0.41 0.32 0.18 0.06 0.25 50 355 LCA351420 LCA353420 4 1400 IP55 1 20° 0.64 0.61 0.57 0.52 0.45 0.35 0.2 0.07 0.25 50 355 LCA351422 LCA353422 4 1400 IP55 1 22° 0.68 0.65 0.6 0.55 0.48 0.38 0.25 45 355 LCA351424 LCA353424 4 1400 IP55 1 24° 0.72 0.68 0.64 0.59 0.51 0.41 0.25 45 355 LCA351426 LCA353426 4 1400 IP55 1 26° 0.75 0.72 0.67 0.62 0.55 0.43 0.25 46 355 LCA351428 LCA353428 4 1400 IP55 1 28° 0.79 0.75 0.7 0.65 0.58 0.45 0.25 47 355 LCA351430 LCA353430 4 1400 IP55 1 30° 0.83 0.79 0.74 0.68 0.6 0.47 0.25 47 355 LCA351432 LCA353432 4 1400 IP55 1 32° 0.87 0.83 0.77 0.71 0.63 0.48 0.25 48 355 LCA351434 LCA353434 4 1400 IP55 1 34° 0.92 0.86 0.81 0.74 0.65 0.5 0.25 48 355 LCA351436 LCA353436 4 1400 IP55 1 36° 0.95 0.89 0.83 0.76 0.67 0.51 0.25 48 355 LCA351438 LCA353438 4 1400 IP55 1 38° 0.98 0.92 0.85 0.78 0.68 0.25 48 Sound Power Level Spectra dB (ref 10 -12Watts) Dia. 1 PhaseStock Ref 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 355 LCA351410 LCA353410 4 Inlet/Outlet 67 70 68 65 66 64 59 49 50 355 LCA351412 LCA353412 4 Inlet/Outlet 67 70 68 65 66 64 59 49 50 355 LCA351414 LCA353414 4 Inlet/Outlet 67 70 68 65 66 64 59 49 50 355 LCA351416 LCA353416 4 Inlet/Outlet 67 70 68 65 66 64 59 49 50 355 LCA351418 LCA353418 4 Inlet/Outlet 67 70 68 65 66 64 59 49 50 355 LCA351420 LCA353420 4 Inlet/Outlet 67 70 68 65 66 64 59 49 50 355 LCA351422 LCA353422 4 Inlet/Outlet 62 65 63 60 61 59 54 44 45 355 LCA351424 LCA353424 4 Inlet/Outlet 62 65 63 60 61 59 54 44 45 355 LCA351426 LCA353426 4 Inlet/Outlet 63 66 64 61 62 60 55 45 46 355 LCA351428 LCA353428 4 Inlet/Outlet 64 67 65 62 63 61 56 46 47 355 LCA351430 LCA353430 4 Inlet/Outlet 64 67 65 62 63 61 56 46 47 355 LCA351432 LCA353432 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48 355 LCA351434 LCA353434 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48 355 LCA351436 LCA353436 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48 355 LCA351438 LCA353438 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48 Performance Curve

255 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° LCA40 - 1 & 3 Phase - 4 Pole Performance Guide1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 20 40 60 80 100 120 140kW@3m 400 LCA401410 LCA403410 4 1400 IP55 1 10° 0.59 0.55 0.51 0.46 0.38 0.27 0.15 0.04 0.25 54 400 LCA401412 LCA403412 4 1400 IP55 1 12° 0.65 0.61 0.57 0.51 0.44 0.33 0.2 0.08 0.25 54 400 LCA401414 LCA403414 4 1400 IP55 1 14° 0.71 0.67 0.63 0.57 0.5 0.39 0.25 0.11 0.25 54 400 LCA401416 LCA403416 4 1400 IP55 1 16° 0.77 0.73 0.69 0.63 0.56 0.45 0.25 54 400 LCA401418 LCA403418 4 1400 IP55 1 18° 0.84 0.8 0.75 0.69 0.61 0.5 0.25 54 400 LCA401420 LCA403420 4 1400 IP55 1 20° 0.91 0.86 0.81 0.74 0.66 0.55 0.25 54 400 LCA401422 LCA403422 4 1400 IP55 1 22° 0.96 0.91 0.86 0.79 0.71 0.6 0.25 48 400 LCA401424 LCA403424 4 1400 IP55 1 24° 1.02 0.97 0.9 0.83 0.75 0.64 0.25 48 400 LCA401426 LCA403426 4 1400 IP55 1 26° 1.08 1.02 0.95 0.88 0.79 0.68 0.25 50 400 LCA401428 LCA403428 4 1400 IP55 1 28° 1.13 1.07 1 0.92 0.83 0.72 0.25 51 400 LCA401430 LCA403430 4 1400 IP55 1 30° 1.19 1.13 1.05 0.97 0.88 0.76 0.25 52 400 LCA401432 LCA403432 4 1400 IP55 1 32° 1.25 1.18 1.1 1.01 0.91 0.79 0.25 52 400 LCA401434 LCA403434 4 1400 IP55 1 34° 1.29 1.22 1.14 1.05 0.94 0.82 0.25 51 400 LCA401436 LCA403436 4 1400 IP55 1 36° 1.33 1.26 1.17 1.08 0.97 0.84 0.25 51 400 LCA401438 LCA403438 4 1400 IP55 1 38° 1.36 1.29 1.2 1.1 0.99 0.84 0.25 50 400 LCA401440 LCA403440 4 1400 IP55 1 40° 1.39 1.31 1.23 1.13 1.01 0.84 0.37 50 Sound Power Level Spectra dB (ref 10 -12Watts) Dia. 1 Phase Stock Ref 3 Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 400 LCA401410 LCA403410 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 400 LCA401412 LCA403412 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 400 LCA401414 LCA403414 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 400 LCA401416 LCA403416 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 400 LCA401418 LCA403418 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 400 LCA401420 LCA403420 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 400 LCA401422 LCA403422 4 Inlet/Outlet 66 68 67 63 64 61 57 48 48 400 LCA401424 LCA403424 4 Inlet/Outlet 66 68 67 63 64 61 57 48 48 400 LCA401426 LCA403426 4 Inlet/Outlet 68 70 69 65 66 63 59 50 50 400 LCA401428 LCA403428 4 Inlet/Outlet 69 71 70 66 67 64 60 51 51 400 LCA401430 LCA403430 4 Inlet/Outlet 70 72 71 67 68 65 61 52 52 400 LCA401432 LCA403432 4 Inlet/Outlet 70 72 71 67 68 65 61 52 52 400 LCA401434 LCA403434 4 Inlet/Outlet 69 71 70 66 67 64 60 51 51 400 LCA401436 LCA403436 4 Inlet/Outlet 69 71 70 66 67 64 60 51 51 400 LCA401438 LCA403438 4 Inlet/Outlet 68 70 69 65 66 63 59 50 50 400 LCA401440 LCA403440 4 Inlet/Outlet 68 70 69 65 66 63 59 50 50 Performance Curve

256 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° LCA45 - 1 & 3 Phase - 4 Pole 1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 40 80 120 160kW@3m 450 LCA451410 LCA453410 4 1400 IP55 1 10° 0.83 0.75 0.63 0.42 0.15 0.25 59 450 LCA451412 LCA453412 4 1400 IP55 1 12° 0.92 0.83 0.71 0.51 0.22 0.25 59 450 LCA451414 LCA453414 4 1400 IP55 1 14° 1.01 0.92 0.8 0.6 0.28 0.25 59 450 LCA451416 LCA453416 4 1400 IP55 1 16° 1.1 1.01 0.88 0.68 0.25 59 450 LCA451418 LCA453418 4 1400 IP55 1 18° 1.2 1.1 0.96 0.76 0.25 54 450 LCA451420 LCA453420 4 1400 IP55 1 20° 1.29 1.18 1.04 0.83 0.25 55 450 LCA451422 LCA453422 4 1400 IP55 1 22° 1.37 1.25 1.11 0.9 0.25 54 450 LCA451424 LCA453424 4 1400 IP55 1 24° 1.45 1.32 1.17 0.96 0.25 54 450 LCA451426 LCA453426 4 1400 IP55 1 26° 1.53 1.4 1.23 1.01 0.37 54 450 LCA451428 LCA453428 4 1400 IP55 1 28° 1.61 1.47 1.29 1.07 0.37 54 450 LCA451430 LCA453430 4 1400 IP55 1 30° 1.7 1.54 1.36 1.13 0.37 54 450 LCA451432 LCA453432 4 1400 IP55 1 32° 1.77 1.61 1.41 1.17 0.37 54 450 LCA451434 LCA453434 4 1400 IP55 1 34° 1.84 1.67 1.46 1.21 0.55 54 450 LCA451436 LCA453436 4 1400 IP55 1 36° 1.9 1.72 1.51 1.24 0.55 54 450 LCA451438 LCA453438 4 1400 IP55 1 38° 1.94 1.76 1.54 1.25 0.55 54 450 LCA451440 LCA453440 4 1400 IP55 1 40° 1.98 1.8 1.58 1.27 0.55 54 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve Dia. 1 PhaseStock Ref 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 450 LCA451410 LCA453410 4 Inlet/Outlet 77 79 78 74 75 72 68 59 59 450 LCA451412 LCA453412 4 Inlet/Outlet 77 79 78 74 75 72 68 59 59 450 LCA451414 LCA453414 4 Inlet/Outlet 77 79 78 74 75 72 68 59 59 450 LCA451416 LCA453416 4 Inlet/Outlet 77 79 78 74 75 72 68 59 59 450 LCA451418 LCA453418 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 LCA451420 LCA453420 4 Inlet/Outlet 73 75 74 70 71 68 64 55 55 450 LCA451422 LCA453422 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 LCA451424 LCA453424 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 LCA451426 LCA453426 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 LCA451428 LCA453428 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 LCA451430 LCA453430 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 LCA451432 LCA453432 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 LCA451434 LCA453434 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 LCA451436 LCA453436 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 LCA451438 LCA453438 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 LCA451440 LCA453440 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54

257 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° LCA50 - 1 & 3 Phase - 4 Pole 1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 40 80 120 160kW@3m 500 LCA501410 LCA503410 4 1400 IP55 1 10° 1.14 1.01 0.84 0.58 0.18 0.25 58 500 LCA501412 LCA503412 4 1400 IP55 1 12° 1.28 1.15 0.97 0.72 0.3 0.25 58 500 LCA501414 LCA503414 4 1400 IP55 1 14° 1.42 1.28 1.1 0.85 0.42 0.25 58 500 LCA501416 LCA503416 4 1400 IP55 1 16° 1.56 1.41 1.22 0.97 0.25 58 500 LCA501418 LCA503418 4 1400 IP55 1 18° 1.69 1.53 1.34 1.09 0.25 58 500 LCA501420 LCA503420 4 1400 IP55 1 20° 1.82 1.65 1.45 1.19 0.37 58 500 LCA501422 LCA503422 4 1400 IP55 1 22° 1.93 1.76 1.56 1.29 0.37 58 500 LCA501424 LCA503424 4 1400 IP55 1 24° 2.04 1.87 1.66 1.39 0.37 58 500 LCA501426 LCA503426 4 1400 IP55 1 26° 2.15 1.97 1.76 1.48 0.37 60 500 LCA501428 LCA503428 4 1400 IP55 1 28° 2.27 2.08 1.86 1.56 0.55 60 500 LCA501430 LCA503430 4 1400 IP55 1 30° 2.38 2.18 1.95 1.64 0.55 61 500 LCA501432 LCA503432 4 1400 IP55 1 32° 2.49 2.27 2.02 1.71 0.55 61 500 LCA501434 LCA503434 4 1400 IP55 1 34° 2.58 2.34 2.08 1.76 0.55 61 500 LCA501436 LCA503436 4 1400 IP55 1 36° 2.65 2.4 2.13 1.78 0.75 61 500 LCA501438 LCA503438 4 1400 IP55 1 38° 2.7 2.46 2.17 1.77 0.75 61 500 LCA501440 LCA503440 4 1400 IP55 1 40° 2.74 2.5 2.2 0.75 61 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve Dia. 1 Phase Stock Ref 3 Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 500 LCA501410 LCA503410 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 LCA501412 LCA503412 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 LCA501414 LCA503414 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 LCA501416 LCA503416 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 LCA501418 LCA503418 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 LCA501420 LCA503420 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 LCA501422 LCA503422 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 LCA501424 LCA503424 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 LCA501426 LCA503426 4 Inlet/Outlet 78 80 76 77 76 73 70 60 60 500 LCA501428 LCA503428 4 Inlet/Outlet 78 80 76 77 76 73 70 60 60 500 LCA501430 LCA503430 4 Inlet/Outlet 79 81 77 78 77 74 71 61 61 500 LCA501432 LCA503432 4 Inlet/Outlet 79 81 77 78 77 74 71 61 61 500 LCA501434 LCA503434 4 Inlet/Outlet 79 81 77 78 77 74 71 61 61 500 LCA501436 LCA503436 4 Inlet/Outlet 79 81 77 78 77 74 71 61 61 500 LCA501438 LCA503438 4 Inlet/Outlet 79 81 77 78 77 74 71 61 61 500 LCA501440 LCA503440 4 Inlet/Outlet 79 81 77 78 77 74 71 61 61

258 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° LCA56 - 1 & 3 Phase - 4 Pole 1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 50 100 150 200 250 300kW@3m 560 LCA561410 LCA563410 4 1400 IP55 1 10° 1.46 1.36 1.23 1.06 0.85 0.58 0.28 0.55 64 560 LCA561412 LCA563412 4 1400 IP55 1 12° 1.67 1.55 1.41 1.23 1.01 0.74 0.43 0.55 64 560 LCA561414 LCA563414 4 1400 IP55 1 14° 1.88 1.75 1.59 1.4 1.17 0.89 0.55 0.55 64 560 LCA561416 LCA563416 4 1400 IP55 1 16° 2.09 1.96 1.8 1.59 1.34 0.55 64 560 LCA561418 LCA563418 4 1400 IP55 1 18° 2.3 2.17 2.01 1.8 1.51 0.75 64 560 LCA561420 LCA563420 4 1400 IP55 1 20° 2.5 2.38 2.22 2.01 1.69 0.75 64 560 LCA561422 LCA563422 4 1400 IP55 1 22° 2.7 2.57 2.41 2.2 1.89 0.75 64 560 LCA561424 LCA563424 4 1400 IP55 1 24° 2.89 2.75 2.59 2.38 2.09 1.1 64 560 LCA561426 LCA563426 4 1400 IP55 1 26° 3.08 2.94 2.77 2.56 2.27 1.1 64 560 LCA561428 LCA563428 4 1400 IP55 1 28° 3.29 3.13 2.95 2.73 2.43 1.1 64 560 LCA561430 LCA563430 4 1400 IP55 1 30° 3.48 3.32 3.13 2.89 2.58 2.1 1.1 64 560 LCA561432 LCA563432 4 1400 IP55 1 32° 3.66 3.49 3.29 3.04 2.72 2.21 1.5 64 560 LCA561434 LCA563434 4 1400 IP55 1 34° 3.82 3.64 3.44 3.19 2.85 2.32 1.5 64 560 LCA561436 LCA563436 4 1400 IP55 1 36° 3.99 3.8 3.58 3.32 2.97 1.5 64 560 - LCA563438 4 1400 IP55 1 38° 4.16 3.96 3.73 3.45 3.08 2.2 64 560 - LCA563440 4 1400 IP55 1 40° 4.34 4.12 3.87 3.57 3.17 2.2 64 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve Dia. 1 PhaseStock Ref 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 560 LCA561410 LCA563410 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561412 LCA563412 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561414 LCA563414 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561416 LCA563416 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561418 LCA563418 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561420 LCA563420 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561422 LCA563422 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561424 LCA563424 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561426 LCA563426 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561428 LCA563428 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561430 LCA563430 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561432 LCA563432 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561434 LCA563434 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 LCA561436 LCA563436 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 - LCA563438 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 - LCA563440 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64

259 1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 50 100 150 200 250 300kW@3m 630 LCA631410 LCA633410 4 1400 IP55 1 10° 2.15 1.99 1.81 1.59 1.33 0.99 0.54 0.55 64 630 LCA631412 LCA633412 4 1400 IP55 1 12° 2.38 2.22 2.04 1.82 1.55 1.21 0.76 0.75 64 630 LCA631414 LCA633414 4 1400 IP55 1 14° 2.64 2.47 2.29 2.06 1.79 1.43 0.97 0.75 64 630 LCA631416 LCA633416 4 1400 IP55 1 16° 2.93 2.76 2.57 2.34 2.05 1.66 1.1 64 630 LCA631418 LCA633418 4 1400 IP55 1 18° 3.24 3.08 2.88 2.63 2.32 1.9 1.1 64 630 LCA631420 LCA633420 4 1400 IP55 1 20° 3.55 3.37 3.17 2.92 2.59 2.14 1.1 64 630 LCA631422 LCA633422 4 1400 IP55 1 22° 3.82 3.63 3.42 3.17 2.85 2.38 1.5 65 630 LCA631424 LCA633424 4 1400 IP55 1 24° 4.06 3.87 3.66 3.4 3.08 2.62 1.5 65 630 LCA631426 LCA633426 4 1400 IP55 1 26° 4.32 4.12 3.9 3.63 3.3 2.84 1.5 65 630 - LCA633428 4 1400 IP55 1 28° 4.61 4.39 4.15 3.87 3.52 3.06 2.2 65 630 - LCA633430 4 1400 IP55 1 30° 4.88 4.65 4.4 4.1 3.74 3.27 2.2 65 630 - LCA633432 4 1400 IP55 1 32° 5.11 4.89 4.63 4.32 3.96 3.5 2.2 65 630 - LCA633434 4 1400 IP55 1 34° 5.34 5.1 4.84 4.54 4.17 3.7 2.2 65 630 - LCA633436 4 1400 IP55 1 36° 5.57 5.32 5.04 4.73 4.34 3.84 3 65 630 - LCA633438 4 1400 IP55 1 38° 5.82 5.55 5.25 4.9 4.48 3 65 630 - LCA633440 4 1400 IP55 1 40° 6.09 5.78 5.44 5.06 4.61 3 65 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° Dia. 1 PhaseStock Ref 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 630 LCA631410 LCA633410 4 Inlet/Outlet 75 71 79 82 81 77 74 66 64 630 LCA631412 LCA633412 4 Inlet/Outlet 75 71 79 82 81 77 74 66 64 630 LCA631414 LCA633414 4 Inlet/Outlet 75 71 79 82 81 77 74 66 64 630 LCA631416 LCA633416 4 Inlet/Outlet 75 71 79 82 81 77 74 66 64 630 LCA631418 LCA633418 4 Inlet/Outlet 75 71 79 82 81 77 74 66 64 630 LCA631420 LCA633420 4 Inlet/Outlet 75 71 79 82 81 77 74 66 64 630 LCA631422 LCA633422 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 LCA631424 LCA633424 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 LCA631426 LCA633426 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 - LCA633428 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 - LCA633430 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 - LCA633432 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 - LCA633434 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 - LCA633436 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 - LCA633438 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 - LCA633440 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 LCA63 - 1 & 3 Phase - 4 Pole

260 LCA71 - 3 Phase - 4 Pole 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve Dia. 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 710 LCA713410 4 Inlet/Outlet 89 84 92 92 90 85 82 75 74 710 LCA713412 4 Inlet/Outlet 89 84 92 92 90 85 82 75 74 710 LCA713414 4 Inlet/Outlet 89 84 92 92 90 85 82 75 74 710 LCA713416 4 Inlet/Outlet 89 84 92 92 90 85 82 75 74 710 LCA713418 4 Inlet/Outlet 89 84 92 92 90 85 82 75 74 710 LCA713420 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 LCA713422 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 LCA713424 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 LCA713426 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 LCA713428 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 LCA713430 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 LCA713432 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 LCA713434 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 LCA713436 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 LCA713438 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 LCA713440 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 100 200 300 400kW@3m 710 LCA713410 4 1420 IP55 1 10° 2.79 2.39 1.87 1.16 0.07 0.75 74 710 LCA713412 4 1420 IP55 1 12° 3.12 2.73 2.2 1.44 0.28 1.1 74 710 LCA713414 4 1420 IP55 1 14° 3.49 3.1 2.56 1.74 0.48 1.1 74 710 LCA713416 4 1420 IP55 1 16° 3.91 3.53 2.98 1.5 74 710 LCA713418 4 1420 IP55 1 18° 4.37 3.99 3.44 2.5 1.5 74 710 LCA713420 4 1420 IP55 1 20° 4.81 4.43 3.87 2.89 2.2 71 710 LCA713422 4 1420 IP55 1 22° 5.19 4.8 4.23 3.23 2.2 71 710 LCA713424 4 1420 IP55 1 24° 5.56 5.13 4.54 3.55 2.2 71 710 LCA713426 4 1420 IP55 1 26° 5.95 5.47 4.85 3.88 3 71 710 LCA713428 4 1420 IP55 1 28° 6.37 5.84 5.19 4.23 3 71 710 LCA713430 4 1420 IP55 1 30° 6.78 6.21 5.53 4.55 3 71 710 LCA713432 4 1420 IP55 1 32° 7.14 6.56 5.86 4.82 4 71 710 LCA713434 4 1420 IP55 1 34° 7.46 6.88 6.16 5.04 4 71 710 LCA713436 4 1420 IP55 1 36° 7.77 7.17 6.42 4 71 710 LCA713438 4 1420 IP55 1 38° 8.09 7.44 6.63 5.5 71 710 LCA713440 4 1420 IP55 1 40° 8.41 7.68 6.81 5.5 71

261 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° LCA80 - 3 Phase - 4 Pole 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 100 200 300 400 500kW@3m 800 LCA803410 4 1420 IP55 1 10° 3.94 3.63 3.24 2.73 2.06 1.27 2.2 80 800 LCA803412 4 1440 IP55 1 12° 4.45 4.14 3.76 3.25 2.58 1.75 2.2 80 800 LCA803414 4 1440 IP55 1 14° 4.94 4.61 4.21 3.69 2.99 2.1 3 80 800 LCA803416 4 1440 IP55 1 16° 5.49 5.14 4.71 4.15 3.4 3 80 800 LCA803418 4 1440 IP55 1 18° 6.12 5.72 5.24 4.63 3.82 3 80 800 LCA803420 4 1440 IP55 1 20° 6.77 6.33 5.8 5.14 4.29 3 77 800 LCA803422 4 1440 IP55 1 22° 7.4 6.94 6.38 5.7 4.82 4 78 800 LCA803424 4 1440 IP55 1 24° 8.02 7.54 6.98 6.29 5.39 4 78 800 LCA803426 4 1440 IP55 1 26° 8.65 8.15 7.57 6.88 5.98 5.5 78 800 LCA803428 4 1440 IP55 1 28° 9.28 8.75 8.15 7.44 6.55 5.5 79 800 LCA803430 4 1440 IP55 1 30° 9.88 9.32 8.69 7.96 7.03 7.5 79 800 LCA803432 4 1440 IP55 1 32° 10.41 9.84 9.19 8.41 7.38 7.5 79 800 LCA803434 4 1440 IP55 1 34° 10.89 10.3 9.62 8.78 7.63 7.5 79 800 LCA803436 4 1440 IP55 1 36° 11.34 10.72 10 9.09 7.8 11 79 800 LCA803438 4 1440 IP55 1 38° 11.78 11.11 10.33 9.35 7.93 11 79 800 LCA803440 4 1440 IP55 1 40° 12.21 11.47 10.63 9.58 8.04 11 79 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve Dia. 3 Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 800 LCA803410 4 Inlet/Outlet 93 87 93 98 96 93 88 80 80 800 LCA803412 4 Inlet/Outlet 93 87 93 98 96 93 88 80 80 800 LCA803414 4 Inlet/Outlet 93 87 93 98 96 93 88 80 80 800 LCA803416 4 Inlet/Outlet 93 87 93 98 96 93 88 80 80 800 LCA803418 4 Inlet/Outlet 93 87 93 98 96 93 88 80 80 800 LCA803420 4 Inlet/Outlet 90 84 90 95 93 90 85 77 77 800 LCA803422 4 Inlet/Outlet 91 85 91 96 94 91 86 78 78 800 LCA803424 4 Inlet/Outlet 91 85 91 96 94 91 86 78 78 800 LCA803426 4 Inlet/Outlet 91 85 91 96 94 91 86 78 78 800 LCA803428 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79 800 LCA803430 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79 800 LCA803432 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79 800 LCA803434 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79 800 LCA803436 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79 800 LCA803438 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79 800 LCA803440 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79

262 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° LCA90 - 3 Phase - 4 Pole 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 100 200 300 400 500 600kW@3m 900 LCA903410 4 1440 IP55 1 10° 5.4 4.95 4.45 3.84 3.11 2.19 1.02 3 79 900 LCA903412 4 1440 IP55 1 12° 6.05 5.63 5.15 4.57 3.85 2.94 1.75 4 80 900 LCA903414 4 1440 IP55 1 14° 6.74 6.34 5.87 5.3 4.58 3.64 2.41 4 80 900 LCA903416 4 1440 IP55 1 16° 7.52 7.11 6.62 6.03 5.27 4.26 4 80 900 LCA903418 4 1440 IP55 1 18° 8.38 7.93 7.4 6.75 5.94 4.8 5.5 81 900 LCA903420 4 1440 IP55 1 20° 9.26 8.76 8.18 7.48 6.6 5.35 5.5 81 900 LCA903422 4 1440 IP55 1 22° 10.1 9.57 8.95 8.21 7.27 5.96 7.5 81 900 LCA903424 4 1440 IP55 1 24° 10.92 10.35 9.71 8.94 7.97 6.62 7.5 81 900 LCA903426 4 1440 IP55 1 26° 11.72 11.14 10.47 9.67 8.68 7.34 7.5 82 900 LCA903428 4 1440 IP55 1 28° 12.51 11.92 11.23 10.42 9.42 8.09 11 82 900 LCA903430 4 1440 IP55 1 30° 13.28 12.69 11.99 11.18 10.17 8.86 11 82 900 LCA903432 4 1440 IP55 1 32° 14.02 13.42 12.74 11.93 10.94 9.62 11 82 900 LCA903434 4 1440 IP55 1 34° 14.74 14.15 13.46 12.64 11.62 10.22 15 82 900 LCA903436 4 1440 IP55 1 36° 15.5 14.87 14.14 13.27 12.14 15 82 900 LCA903438 4 1440 IP55 1 38° 16.29 15.6 14.8 13.81 12.47 15 82 900 LCA903440 4 1440 IP55 1 40° 17.1 16.34 15.44 14.3 12.72 15 82 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve Dia. 3 Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 900 LCA903410 4 Inlet/Outlet 89 83 91 97 95 92 87 79 79 900 LCA903412 4 Inlet/Outlet 90 84 92 98 96 93 88 80 80 900 LCA903414 4 Inlet/Outlet 90 84 92 98 96 93 88 80 80 900 LCA903416 4 Inlet/Outlet 90 84 92 98 96 93 88 80 80 900 LCA903418 4 Inlet/Outlet 91 85 93 99 97 94 89 81 81 900 LCA903420 4 Inlet/Outlet 91 85 93 99 97 94 89 81 81 900 LCA903422 4 Inlet/Outlet 91 85 93 99 97 94 89 81 81 900 LCA903424 4 Inlet/Outlet 91 85 93 99 97 94 89 81 81 900 LCA903426 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 LCA903428 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 LCA903430 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 LCA903432 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 LCA903434 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 LCA903436 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 LCA903438 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 LCA903440 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82

263 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° LCA100 - 3 Phase - 4 Pole 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 150 300 450 600kW@3m 1000 LCA1003410 4 1440 IP55 1 10° 6.5 5.68 4.63 3.18 1.14 4 89 1000 LCA1003412 4 1440 IP55 1 12° 7.66 6.85 5.79 4.31 2.11 4 89 1000 LCA1003414 4 1440 IP55 1 14° 8.83 8.01 6.94 5.41 3.04 5.5 89 1000 LCA1003416 4 1440 IP55 1 16° 10.02 9.17 8.06 6.48 5.5 89 1000 LCA1003418 4 1440 IP55 1 18° 11.23 10.3 9.15 7.51 7.5 89 1000 LCA1003420 4 1440 IP55 1 20° 12.4 11.41 10.2 8.5 7.5 89 1000 LCA1003422 4 1440 IP55 1 22° 13.51 12.47 11.22 9.49 7.5 89 1000 LCA1003424 4 1440 IP55 1 24° 14.53 13.5 12.23 10.49 11 89 1000 LCA1003426 4 1440 IP55 1 26° 15.45 14.47 13.23 11.53 11 89 1000 LCA1003428 4 1440 IP55 1 28° 16.33 15.41 14.24 12.6 15 89 1000 LCA1003430 4 1440 IP55 1 30° 17.31 16.4 15.24 13.6 15 89 1000 LCA1003432 4 1440 IP55 1 32° 18.48 17.47 16.21 14.48 15 89 1000 LCA1003434 4 1440 IP55 1 34° 19.74 18.58 17.15 15.26 18.5 89 1000 LCA1003436 4 1440 IP55 1 36° 20.93 19.64 18.07 16 18.5 89 1000 LCA1003438 4 1440 IP55 1 38° 22.01 20.64 18.98 16.71 18.5 89 1000 LCA1003440 4 1440 IP55 1 40° 23.03 21.6 19.87 17.41 22 89 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve Dia. 3 Phase StockRef Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 1000 LCA1003410 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003412 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003414 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003416 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003418 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003420 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003422 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003424 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003426 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003428 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003430 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003432 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003434 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003436 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003438 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 LCA1003440 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89

264 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 34° LCA125 - 3 Phase - 4 Pole 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 250 500 750 1000 1250 1500 1750 2000kW@3m 1250 LCA1253420 4 1475 IP55 1 20° 20.81 18.64 16.07 12.79 8.59 5.26 2.6 22 83 1250 LCA1253422 4 1475 IP55 1 22° 23.03 20.92 18.43 15.28 10.86 7.33 4.1 1.46 30 84 1250 LCA1253424 4 1475 IP55 1 24° 25.27 23.16 20.69 17.37 12.55 8.47 5.18 2.51 30 85 1250 LCA1253426 4 1475 IP55 1 26° 27.51 25.39 22.96 19.57 14.61 9.54 6.33 3.58 37 86 1250 LCA1253428 4 1475 IP55 1 28° 29.72 27.6 25.18 21.83 16.82 10.6 7.46 4.64 1.84 37 87 1250 LCA1253430 4 1475 IP55 1 30° 31.81 29.62 27.15 23.86 18.86 11.45 8.46 5.62 2.71 37 87 1250 LCA1253432 4 1475 IP55 1 32° 33.89 31.63 29.13 25.88 21.13 45 88 1250 LCA1253434 4 1475 IP55 1 34° 36.01 33.63 30.98 27.66 22.97 45 88 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve Dia. 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8kdBA @3m 1250 LCA1253420 4 Inlet/Outlet 98 105 101 100 98 95 92 89 83 1250 LCA1253422 4 Inlet/Outlet 99 106 102 101 99 96 93 90 84 1250 LCA1253424 4 Inlet/Outlet 100 107 103 102 100 97 94 91 85 1250 LCA1253426 4 Inlet/Outlet 101 108 104 103 101 98 95 92 86 1250 LCA1253428 4 Inlet/Outlet 102 109 105 104 102 99 96 93 87 1250 LCA1253430 4 Inlet/Outlet 102 109 105 104 102 99 96 93 87 1250 LCA1253432 4 Inlet/Outlet 103 110 106 105 103 100 97 94 88 1250 LCA1253434 4 Inlet/Outlet 103 110 106 105 103 100 97 94 88

265 Electrical Details Speed Controllers Used in conjunction with speed controllable fans Vent-Axia offers a choice of speed controllers, the traditional Five-Step Auto Transformer or the Inverter Speed Controller. The Five-Step-Auto Transformer provides five stepped speed settings without the electronic motor harmonic noise associated with all electronic or solid state type Speed Controllers. eDemand Speed Controllers & Inverters see Accessories & Controllers Section. 3 Phase 2 Pole eDemand Controller Stock Ref rpm Pitch Angle Motor kW S.C. Amps F.L.C Amps Starting Method Starter Ref Overload Ref Transform Controller VoltageControl 1/3 PhaseInverter 3 PhaseInverter LCA25 2800 25°-40° 0.37 5.82 0.97 D.O.L. 444747 444700 - - 444177 444172 LCA31 2800 10°-24° 0.37 5.82 0.97 D.O.L. 444747 444700 - - 444177 444172 LCA31 2800 26°-32° 0.55 8.52 1.42 D.O.L. 444747 444701 - - 444177 444172 LCA31 2800 34°-38° 0.75 10.62 1.77 D.O.L. 444747 444701 - - 444177 444172 LCA35 2800 10°-12° 0.37 5.82 0.97 D.O.L. 444747 444700 - - 444177 444172 LCA35 2800 14°-20° 0.55 8.52 1.42 D.O.L. 444747 444701 - - 444177 444172 LCA35 2800 22°-26° 0.75 10.62 1.77 D.O.L. 444747 444701 - - 444177 444172 LCA35 2800 28°-34° 1.1 15.06 2.51 D.O.L. 444747 444702 - - 444177 444173 LCA35 2800 36°-38° 1.5 19.68 3.28 D.O.L. 444747 444702 - - 444177 444173 LCA35 2800 40° 2.2 27.66 4.61 D.O.L. 444747 444703 - - - 444174 LCA40 2800 10°-12° 0.55 8.52 1.42 D.O.L. 444747 444701 - - 444177 444172 LCA40 2800 14°-18° 0.75 10.62 1.77 D.O.L. 444747 444701 - - 444177 444172 LCA40 2800 20°-26° 1.1 15.06 2.51 D.O.L. 444747 444702 - - 444177 444173 LCA40 2800 28°-32° 1.5 19.68 3.28 D.O.L. 444747 444702 - - 444177 444173 LCA40 2800 34°-38° 2.2 27.66 4.61 D.O.L. 444744 444703 - - - 444174 LCA40 2800 40° 3 42.2 6.03 D.O.L. 444747 444704 - - - 444174 LCA45 2880 10°-12° 1.1 15.06 2.51 D.O.L. 444747 444702 - - 444177 444173 LCA45 2880 14°-18° 1.5 19.68 3.28 D.O.L. 444747 444702 - - 444177 444173 LCA45 2880 20°-26° 2.2 27.66 4.61 D.O.L. 444747 444703 - - 444177 444173 LCA45 2880 28°-32° 3 42.2 6.03 D.O.L. 444747 444704 - - - 444174 LCA50 2880 10°-12° 1.5 19.68 3.28 D.O.L. 444747 444702 - - 444177 444173 LCA50 2880 14°-18° 2.2 27.66 4.61 D.O.L. 444747 444703 - - - 444174 LCA50 2880 20°-24° 3 42.2 6.03 D.O.L. 444747 444704 - - - 444174 LCA50 2880 26°-30° 4 59.1 7.88 D.O.L. 444747 444705 - - - 444175 LCA50 2880 32°-36° 5.5 78.8 10.5 D.O.L. 444748 444706 - - - 444175 1 Phase 2 Pole eDemand Controller Stock Ref rpm Pitch Angle Motor kW S.C. Amps F.L.C Amps Starting Method Starter Ref Overload Ref Transform Controller Voltage Control 1/3 PhaseInverter 3 Phase Inverter LCA25 2800 25°-40° 0.37 8 2.6 D.O.L. 444744 444702 - - - - LCA31 2800 10°-24° 0.37 8 2.6 D.O.L. 444744 444702 - - - - LCA31 2800 26°-32° 0.55 14 3.6 D.O.L. 444744 444703 - - - - LCA31 2800 34°-38° 0.75 16 4.5 D.O.L. 444744 444703 - - - - LCA35 2800 10°-12° 0.55 14 3.6 D.O.L. 444744 444703 - - - - LCA35 2800 22°-26° 0.75 16 4.5 D.O.L. 444744 444703 - - - - LCA35 2800 28°-34° 1.1 23 6.6 D.O.L. 444744 444704 - - - - LCA35 2800 36°-38° 1.5 31 8.5 D.O.L. 444744 444705 - - - - LCA40 2800 10°-12° 0.55 14 3.6 D.O.L. 444744 444703 - - - - LCA40 2800 14°-18° 0.75 16 4.5 D.O.L. 444744 444704 - - - - LCA40 2800 20°-24° 1.1 23 6.6 D.O.L. 444744 444704 - - - - LCA40 2800 26°-32° 1.5 31 8.5 D.O.L. 444744 444705 - - - - 1 phase 2 pole is not speed controllable

266 Speed Controllers Used in conjunction with speed controllable fans Vent-Axia offers a choice of speed controllers, the traditional Five-Step Auto Transformer or the Inverter Speed Controller. The Five-Step-Auto Transformer provides five stepped speed settings without the electronic motor harmonic noise associated with all electronic or solid state type Speed Controllers. eDemand Speed Controllers & Inverters see Accessories and Controls Section. Electrical Details 3 Phase 2 Pole eDemand Controller Stock Ref rpm Pitch Angle Motor kW S.C. Amps F.L.C Amps Starting Method Starter Ref Overload Ref Transform Controller VoltageControl 1/3 PhaseInverter 3 PhaseInverter LCA50 2880 38°-40° 7.5 106 14.1 D.O.L. 444748 444707 - - - 444176 LCA56 2880 10°-14° 4 59.1 7.88 D.O.L. 444747 444705 - - - 444175 LCA56 2880 16°-18° 5.5 78.8 10.5 D.O.L. 444748 444706 - - - 444175 LCA56 2880 20°-24° 7.5 106 14.1 D.O.L. 444748 444707 - - - 444176 LCA63 2940 10°-12° 5.5 78.8 10.5 D.O.L. 444748 444706 - - - 444175 LCA63 2940 14°-16° 7.5 106 14.1 D.O.L. 444748 444707 - - - 444176 LCA63 2940 18°-22° 11 52.3 20.9 Star Delta 444843 444707 - - - - LCA63 2940 24°-28° 15 75.3 30.1 Star Delta - - - - - - 1 Phase 4 Pole eDemand Controller Stock Ref rpm Pitch Angle Motor kW S.C. Amps F.L.C Amps Starting Method Starter Ref Overload Ref Transform Controller VoltageControl 1/3 PhaseInverter 3 PhaseInverter LCA25 1400 25°-40° 0.25 5 2 D.O.L. 444744 444701 10314103 444164 - - LCA31 1400 10°-38° 0.25 5 2 D.O.L. 444744 444701 10314103 444164 - - LCA35 1400 10°-38° 0.25 5 2 D.O.L. 444744 444701 10314103 444164 - - LCA40 1400 10°-36° 0.25 5 2 D.O.L. 444744 444701 10314103 444164 - - LCA40 1400 38°-40° 0.37 7 2.9 D.O.L. 444744 444702 10314105 444164 - - LCA45 1400 10°-24° 0.25 5 2 D.O.L. 444744 444701 10314103 444164 - - LCA45 1400 26°-32° 0.37 7 2.9 D.O.L. 444744 444702 10314105 444164 - - LCA45 1400 34°-40° 0.55 11 3.9 D.O.L. 444744 444703 10314105 444164 - - LCA50 1400 10°-18° 0.25 5 2 D.O.L. 444744 444701 10314103 444164 - - LCA50 1400 20°-26° 0.37 7 2.9 D.O.L. 444744 444702 10314105 444164 - - LCA50 1400 28°-34° 0.55 11 3.9 D.O.L. 444744 444703 10314105 444164 - - LCA50 1400 36°-40° 0.75 15 5.3 D.O.L. 444744 444704 10314107 444165 - - LCA56 1400 10°-16° 0.55 11 3.9 D.O.L. 444744 444703 10314105 444164 - - LCA56 1400 18°-22° 0.75 15 5.3 D.O.L. 444744 444704 10314107 444165 - - LCA56 1400 24°-30° 1.1 22 7 D.O.L. 444744 444705 10314120 444165 - - LCA56 1400 32°-36° 1.5 32 9.3 D.O.L. 444744 444706 10314120 - - - LCA63 1400 10°-12° 0.55 11 3.9 D.O.L. 444744 444703 10314105 444164 - - LCA63 1400 14°-16° 0.75 15 5.3 D.O.L. 444744 444704 10314107 444165 - - LCA63 1400 18°-24° 1.1 22 7 D.O.L. 444744 444705 10314120 444165 - - LCA63 1400 22°-26° 1.5 32 9.3 D.O.L. 444744 444706 10314120 - - - 3 Phase 4 Pole eDemand Controller Stock Ref rpm Pitch Angle Motor kW S.C. Amps F.L.C Amps Starting Method Starter Ref Overload Ref Transform Controller VoltageControl 1/3 PhaseInverter 3 PhaseInverter LCA25 1400 25°-40° 0.25 4.26 0.71 D.O.L. 444747 444699 10314301 444166 444177 444172 LCA31 1400 10°-38° 0.25 5.04 0.84 D.O.L. 444747 444699 10314301 444166 444177 444172 LCA35 1400 10°-38° 0.25 5.04 0.84 D.O.L. 444747 444699 10314301 444166 444177 444172 LCA40 1400 10°-26° 0.25 5.04 0.84 D.O.L. 444747 444699 10314301 444166 444177 444172 LCA40 1400 28°-38° 0.25 5.04 0.84 D.O.L. 444747 444699 10314301 444166 444177 444172 LCA40 1400 40° 0.37 6.66 1.11 D.O.L. 444747 444700 10314301 444166 444177 444172

267 Electrical Details 3 Phase 4 Pole eDemand Controller Stock Ref rpm Pitch Angle Motor kW S.C. Amps F.L.C Amps Starting Method Starter Ref Overload Ref Transform Controller VoltageControl 1/3 PhaseInverter 3 PhaseInverter LCA45 1400 10°-24° 0.25 5.04 0.84 D.O.L. 444747 444699 10314301 444166 444177 444172 LCA45 1400 26°-32° 0.37 6.66 1.11 D.O.L. 444747 444700 10314301 444166 444177 444172 LCA45 1400 34°-40° 0.55 9.48 1.58 D.O.L. 444747 444701 10314304 444166 444177 444172 LCA50 1400 10°-18° 0.25 5.04 0.84 D.O.L. 444747 444699 10314301 444166 444177 444172 LCA50 1400 20°-26° 0.37 6.66 1.11 D.O.L. 444747 444700 10314301 444166 444177 444172 LCA50 1400 28°-34° 0.55 9.48 1.58 D.O.L. 444747 444701 10314304 444166 444177 444172 LCA50 1400 36°-40° 0.75 11.58 1.93 D.O.L. 444747 444701 10314304 444166 444177 444172 LCA56 1400 10°-16° 0.55 9.48 1.58 D.O.L. 444747 444701 10314304 444166 444177 444172 LCA56 1400 18°-22° 0.75 11.58 1.93 D.O.L. 444747 444702 10314304 444166 444177 444172 LCA56 1400 24°-30° 1.1 15.84 2.64 D.O.L. 444747 444702 10314304 444166 444177 444173 LCA56 1400 32°-36° 1.5 20.7 3.45 D.O.L. 444747 444702 10314304 444166 444177 444173 LCA56 1400 38°-40° 2.2 33.9 4.84 D.O.L. 444747 444703 10314307 444167 - 444174 LCA63 1400 10° 0.55 9.48 1.58 D.O.L. 444747 444701 10314304 444166 444177 444172 LCA63 1400 12°-14° 0.75 11.58 1.93 D.O.L. 444747 444701 10314304 444166 444177 444172 LCA63 1400 16°-18° 1.1 15.84 2.64 D.O.L. 444747 444702 10314304 444166 444177 444173 LCA63 1400 22°-26° 1.5 20.7 3.45 D.O.L. 444747 444702 10314307 444166 444177 444173 LCA63 1400 28°-34° 2.2 33.9 4.84 D.O.L. 444747 444703 10314307 444167 - 444174 LCA63 1400 36°-40° 3 45.3 6.47 D.O.L. 444747 444704 10314311 444167 - 444174 LCA71 1420 10° 0.75 11.58 1.93 D.O.L. 444747 444701 10314304 444166 444177 444172 LCA71 1420 12°-14° 1.1 15.84 2.64 D.O.L. 444747 444702 10314304 444166 444177 444173 LCA71 1420 16°-18° 1.5 20.7 3.45 D.O.L. 444747 444702 10314304 444166 444177 444173 LCA71 1420 20°-24° 2.2 33.9 4.84 D.O.L. 444747 444703 10314307 444167 - 444174 LCA71 1420 26°-30° 3 45.3 6.47 D.O.L. 444747 444704 10314311 444167 - 444174 LCA71 1420 32°-36° 4 57.8 8.26 D.O.L. 444747 444705 10314311 444167 - 444175 LCA71 1420 38°-40° 5.5 77 11 D.O.L. 444748 444706 - 444168 - 444175 LCA80 1420 10°-12° 2.2 33.9 4.84 D.O.L. 444747 444703 10314307 444167 - 444174 LCA80 1440 14°-20° 3 45.3 6.47 D.O.L. 444747 444704 10314311 444167 - 444174 LCA80 1440 22°-24° 4 57.8 8.26 D.O.L. 444747 444705 10314311 444167 - 444175 LCA80 1440 26°-28° 5.5 77 11 D.O.L. 444748 444706 - 444168 - 444175 LCA80 1440 30°-34° 7.5 102.2 14.6 D.O.L. 444748 444707 - - - 444176 LCA80 1440 36°-40° 11 52.3 20.9 Star Delta 444843 444707 - - - - LCA90 1440 10° 3 45.3 6.47 D.O.L. 444747 444704 10314311 444167 - 444174 LCA90 1440 12°-16° 4 57.8 8.26 D.O.L. 444747 444705 10314311 444167 - 444175 LCA90 1440 18°-20° 5.5 77 11 D.O.L. 444748 444706 - 444168 - 444175 LCA90 1440 22°-26° 7.5 102.2 14.6 D.O.L. 444748 444707 - - - 444176 LCA90 1440 28°-32° 11 52.3 20.9 Star Delta 444843 444707 - - - - LCA90 1440 34°-40° 15 75.3 30.1 Star Delta - - - - - - LCA100 1440 10°-12° 4 57.8 8.26 D.O.L. 444747 444705 10314311 444167 - 444175 LCA100 1440 14°-16° 5.5 77 11 D.O.L. 444748 444706 - 444168 - 444175 LCA100 1440 18°-22° 7.5 102.2 14.6 D.O.L. 444748 444707 - - - 444176 LCA100 1440 24°-26° 11 52.3 20.9 Star Delta 444843 444707 - - - - LCA100 1440 28°-32° 15 75.3 30.1 Star Delta - - - - - - LCA100 1440 34°-38° 18.5 86 34.3 Star Delta - - - - - - LCA100 1440 40° 22 102 40.6 Star Delta - - - - - - LCA125 1475 20° 22 102 40.6 Star Delta - - - - - - LCA125 1475 22°-24° 30 131 54.7 Star Delta - - - - - - LCA125 1475 26°-30° 37 159 66.4 Star Delta - - - - - - LCA125 1475 32°-34° 45 193 80.5 Star Delta - - - - - -

268 Fan Attenuator DetailsAn attenuator without Pod offers negligible resistance to air flow, and therefore the pressure loss can be considered to be the same as that for the equivalent length of ducting.Resistance Graph for Axial Attenuator with Pod1 RESISANCE (Pa) 40 0 MEAN DUCT VELOCITY m/s 10 20 30 0 2 3 4 5 6 7 8 9 10 Attenuator Insertion Loss Data Dia Stock Ref63 125 250 500 1k 2k 4k 8k kg approx 250 10514250 2 3 6 11 16 11 10 6 20 315 10514315 2 3 6 11 16 11 10 6 22 355 10514355 2 3 6 12 16 11 10 6 30 400 10514400 2 3 6 13 16 12 10 6 41 450 10514450 2 4 6 14 17 12 10 6 50 500 10514500 3 4 7 14 17 14 11 7 59 560 10514560 2 4 8 15 18 14 11 7 70 630 10514630 3 4 8 16 18 14 11 7 82 710 10514710 1 2 6 9 12 10 6 2 90 800 10514800 1 2 6 9 12 10 6 2 100 900 10514900 1 2 6 9 12 10 6 2 145 1000 10514000 1 2 6 9 12 10 6 2 184 1250 105141250 1 2 6 9 12 10 6 2 150 Melinex lined attenuators are available on request Case Axial Attenuator Fitted with Pod Insertion Losses Dia Stock Ref63 125 250 500 1k 2k 4k 8k kg approx315 10500315 6 7 12 18 27 25 22 19 32 355 10500355 3 8 12 18 28 26 22 19 44 400 10500400 3 8 12 18 28 26 23 19 60 450 10500450 4 8 14 20 28 26 23 19 73 500 10500500 4 8 14 20 29 26 23 19 87 560 10500560 4 9 14 20 29 26 23 19 102 630 10500630 4 9 14 20 29 26 23 19 120 710 10500710 6 10 20 30 35 28 25 22 134 800 10500800 6 10 20 30 35 28 25 22 149 900 10500900 6 10 20 30 35 28 25 22 211 1000 105001000 6 10 20 30 35 28 25 22 267 1250 105001250 6 10 17 28 27 21 18 17 222

269 Attenuator Dimensions (mm) StockModelRef a Ø b Ø c Ø d e Ø n LCA25 10514250 350 292 254 375 M8 4LCA31 10514315 415 355 315 475 M8 8LCA35 10514355 455 395 355 540 M8 8LCA40 10514400 500 450 400 600 M10 8LCA45 10514450 550 500 450 675 M10 8LCA50 10514500 600 560 500 750 M10 12LCA56 10514560 660 620 560 810M10 12LCA63 10514630 730 690 630 940 M10 12LCA71 10514710 814 700 710 1070 M10 16LCA80 10514800 900 860 796 1200 M10 16LCA90 10514900 999 970 893 1350 M1016LCA100 105141000 1108 1070 1070 1500 M10 16LCA125 105141250 1350 1320 1250 1875 M10 20

270 Accessory Dimensions (mm) Inlet Wire Guard ‘K’ factor loss 0.25 Available for direct fixing to either side of the fan using flange sizing holes.Constructed to meet BS 848 Part 5. Anti-Vibration Mounts Coupling Flange Rolled from mild steel.Dimensionally matched to fan flange and fixing holes.Stock Ref a Ø b c Ø d Ø e Ø n 10506 250 335 30 295 250 10 8 10506315 385 30 355 315 10 8 10506355 425 45 395 355 10 8 10506400 480 45 450 400 12 8 10506450 530 60 500 450 12 8 10506500 590 0 560 500 12 12 10506560 650 75 620 560 12 12 10506630 720 75 690 630 12 1210506710A 800 40 770 710 12 1610506800A 890 40 860 800 12 1610506900A 1038 50 970 900 14 16105061000A 1138 50 1070 1000 14 16105061250A 1390 83 1320 1250 15 20Stock Refa b 10505250 330 3 10505315 380 3 10505355 420 3 10505400 475 3 10505450 525 3 10505500 595 3 10505560 655 3 10505630 725 3 10505710 784 10 10505800 870 10 10505900 970 10 105051000 1090 10 105051250 1370 10 Max. Load Stock RefA B C D E F G H kg68MP033G 37 26 2767 54 7 3 M 8 2368MP055B 37 26 27 67 54 7 3 M8 3668MP133G 57 46 35 95 76 10.5 4 M12 9168MP165R 57 46 35 95 76 10.5 4 M12 245 Mounting Feet Stock Refa b c d e f g h i 10503250 232 24 180 240 10 14 115 146 130 10503315 275 24 224 240 10 14 115 177.5 167 10503355 303 24 250 250 10 14 125 197.5 187 10503400 348 24 280 300 12 14 135 225 213 10503450 384 24 315 360 12 14 155 250 238 10503500 425 24 315 360 12 14 135 280 268 10503560 475 24 355 355 12 14 155 310 298 10503630 520 24 400 400 12 14 175 345 333 10503710A 710 40 610 435 13 18 240 385 365 10503800A 800 40 700 480 13 18 262 430 410 10503900A 900 40 800 535 13 18 288 485 460 105031000A 1000 40 900 580 15 18 314 535 510 105031250A 1250 80 1150 868 15 26 366 660 640 Set of 2 feet supplied as a set of 4. For more information on the ‘K’ factor, refer to General Information Section

271 Accessories Mounting Inlet Wire Coupling Ancillary Axial Attenuator Anti Vibration Feet - set of 2 Guard Flange Pack Attenuator inc. PodMount Model Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref LCA25 10503250 10505250 10506250 10513250 10514250 - 68MP033G LCA31 10503315 10505315 10506315 10513315 10514315 10500315 68MP033G LCA35 10503355 10505355 10506355 10513355 10514355 10500355 68MP033G LCA40 10503400 10505400 10506400 10513400 10514400 10500400 68MP033G LCA45 10503450 10505450 10506450 10513450 10514450 10500450 68MP033G LCA50 10503500 10505500 10506500 10513500 10514500 10500500 68MP033G LCA56 10503560 10505560 10506560 10513560 10514560 10500560 68MP033G LCA63 10503630 10505630 10506630 10513630 10514630 10500630 68MP033G LCA71 10503710A 10505710 10506710A 10513710A 10514710A 10500710 68MP055B LCA80 10503800A 10505800 10506800A 10513800A 10514800A 10500800 68MP055B LCA90 10503900A 10505900 10506900A 10513900A 10514900A 10500900 68MP133G LCA100 105031000A 105051000 105061000A 105131000A 105141000A 105001000 68MP133G LCA125 105031250A 105051250 105061250A 105131250A 105141250A 105001250 68MP165R consists of 2 Matching Flanges, 2 Flexible Connectors, 2 Mounting Feet, 4 Anti Vibration Mounts, 4 Worm Drive Clips Typical Installation Vent-Axia attenuatorlength = 11/2 x duct dia. DUCT Cased axial ancillary pack consists of 2 matching flanges, 2 flexible connections, 2 mounting feet, 4 anti-vibration mounts and 4 worm drive clips Pod available for extra attenuation Class ‘F’ motor insulation as standard Motors and TerminalBox protected to IP55against dust andwater jets DUCT

272 Kitchen Axial Fan(KAF) •Fully ERP 2015 compliant •Designed to operate at elevated temperatures (70˚C max) •All models speed controllable via matched eDemand inverter controls •Robust motor construction for aggressive conditions •Die cast aluminium impellers •IP65 motor and terminal box, suitable for internal or externalmounting as standard •Motor insulation class H, suitable for induct operatingtemperatures of -40˚C to + 70˚C •Standard Thermal Overload Protection •Maximum operating temperature indicator label The ever tightening requirement for kitchen ventilation systems with higher filtration levels and long duct runs requires a powerful and yet compact fan to provide a cost-effective controllable ventilation solution suitable for operating reliably in atmospherically aggressive installations. A first within the H&V industry, Vent-Axia’s New Kitchen Axial Fan range provides such a solution offering robustly engineered fans and motors designed and tested for operation at elevated temperatures (up to 70˚C induct) whilst utilising speed control. Utilising Vent-Axia’s advanced eDemand Inverter controls provides accurate and reliable control functionality whilst offering substantial running cost reductions and noise control. Availableinfoursizes: 450, 500, 560 and 630mm diameter with a performanceenvelope from0.65m3/sto5.93m3/s and pressure development of up to 600 Pa. Ensuring a compact design, the units have been constructed from a single sheet of steel, with a single 2 pole motor and axial impeller mounted within the length of the unit casing. The unit is manufactured from electro welded steel with an epoxy paint finish. Factory assembled to BS EN ISO 9001 ensuring a quiet and vibration free unit. All sizes are protected with a tough black epoxy paint finish for those harsh environmental conditions, internally or externally. Ensuring ease of installation the motor is wired directly into a single IP65 terminal box. Axial Impellers The impeller is manufactured in die-cast aluminium and fitted with narrow profiled blades, which provide the maximum efficiency at the maximum airflow. Airflow is Form A to ensure maximum cooling airflow over the motor. Motors Specifically designed for this range of fans and the expected environmental conditions. Greased for life ball bearings with temperature resilient grease specially selected to operate at the elevated temperatureslikely to be encountered in kitchen applications whilst allowing the fans to be installed at any angle. Rotors are dynamically balanced to ISO 1940 grade G6.3. Motors are protected to IP65 against dust and water jets complying with BS EN 60529. They have ribbed aluminium body castings and are mounted towards the airstream for efficient cooling. Motor insulation is Class ‘H’ (from -40°C to +70°C). All models are speed controllable by either voltage control or frequency inverter (see electrical section for details). Electrical Single phase 220-240V/50 Hz. Capacitor start and run. Three phase 380V-415V/50Hz. All motors are fitted with Standard Thermal Overload Protection (S.T.O.P), which should be wired into all controller circuits and into starter contactors. Terminal Box IP65 terminal box is supplied with all models with 20mm PGII entry. Performance The fan performance is tested and certified in accordance with BS 848 Part 1 1980. Sound Levels Fan sound levels, measured in a reverberant chamber in accordance with BS848 part 2 published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at reference level of 2 x10–5Pa (20 micro-pascal). The sound power level spectra figures are dB with a reference levelof 10–12 Watts (1 pico-watt). To ensure minimum noise levels during speed control, an auto transformer speed control is recommended.

273 Accessories •eDemand Inverter Speed Controllers •Auto Transformer Speed Controllers •Mounting Ancillary Packs •Cased Attenuators •Mounting Feet•Wire Inlet Guard •Coupling Flanges Warranty Standard 2 year warranty, extendable to 5 years by registration, subject to installation and maintenance in accordance with fitting and operating instructions supplied with product. Performance Curve Performance Guide Speed Performance m 3 /s at Pa Motor Amps Amps Stock Ref rpm Phase Pole Curve 0 50 100 150 200 300 400 500 600 kW S.C. F.L.C. KAF45012 2850 1 2 1 2.1 2 1.86 1.69 1.49 1.08 0.65 1.1 29 6.6 KAF50012 2850 1 2 2 3.38 3.2 2.94 2.73 2.47 1.89 1.2 1.5 35 7.8 KAF56012 2800 1 2 3 4.27 4.1 3.95 3.81 3.64 3.28 2.89 2.37 1.18 2.2 66 15 KAF63012 2860 1 2 4 4.74 4.5 4.2 4 3.75 3.27 2.7 2.1 1.00 3 80 13.5 KAF45032 2830 3 2 5 2.13 2 1.86 1.72 1.52 1 1.1 11 2 KAF50032 2830 3 2 6 3.67 3.56 3.38 3.23 3.02 2.63 2.2 1.5 17 3.4 KAF56032 2760 3 2 7 3.57 3.45 3.3 3.16 3.03 2.75 2.46 2.15 1.48 2.2 32 4.9 KAF63032 2785 3 2 8 5.93 5.69 5.49 5.26 5.03 4.45 3.78 2.87 1.5 4 66 7.8 Sound Power Level Spectra dB (re 10 –12 Watts) Stock Ref Phase Pole 125 250 500 1k 2k 4k 8k dBA @ 3m KAF45012 Inlet/Outlet 1 2 70 71 79 82 82 79 74 67 KAF50012 Inlet/Outlet 1 2 70 76 79 81 81 80 75 67 KAF56012 Inlet/Outlet 1 2 79 94 97 99 98 94 86 78 KAF63012 Inlet/Outlet 1 2 79 90 98 99 98 97 91 81 KAF45032 Inlet/Outlet 3 2 63 73 80 82 83 81 76 68 KAF50032 Inlet/Outlet 3 2 69 80 83 84 85 84 80 70 KAF56032 Inlet/Outlet 3 2 86 98 97 97 92 87 80 75 KAF63032 Inlet/Outlet 3 2 79 90 98 98 99 97 91 81 Published dB(A) figures are free field sound levels at 3m with spherical propagation at a reference level of 2x10-5 Pa. The free field sound power level spectra figure are dB with reference of 10 -12 Watts. To ensure minimum noise levels during speed control an auto transformer or inverter speed controller is recommended. STATIC PRESSURE P a 1 1 1 2 1 3 1 4 0 100 200 300 400 500 600 AIR VOLUME m 3 /s 0 1 2 3 4 5 6 STATIC PRESSURE P a 0 100 200 300 400 500 600 AIR VOLUME m 3 /s 0 1 2 3 4 5 6 1 5 1 6 1 7 1 8

274 b a a g i h d f Øe Øe b c d n (no. of fixing holes) Øe(nutsert) Øa Øb Øc Resistance Graph For Case Attenuator Fitted With Pod Threaded hole to take bolt 1 Resist ance Pa 40 Mean Duct Velocitym/s 0 10 20 30 0 10 2 3 4 5 6 7 8 9 Accessories Dimensions (mm) n (number of fixing holes) eØ dØ cØ b direction ofairflow aØ Fan Dimensions (mm) Size øa b øc ød øe n kg approx 450 450 375 500 530 12 8 41 500 500 375 560 590 12 12 46 560 560 520 620 650 12 12 59 630 630 520 690 720 12 12 64 Attenuator Insertion Losses Dia 63 125 250 500 1k 2k 4k 8k 450 2 4 6 14 17 12 10 6 500 3 4 7 14 17 14 11 7 560 3 4 8 15 18 14 11 7 630 3 4 8 16 18 14 11 7 Attenuator Fitted with Pod Insertion Losses Dia 63 125 250 500 1k 2k 4k 8k 450 4 8 14 20 28 26 23 19 500 4 8 14 20 29 26 23 19 560 4 9 14 20 29 26 23 19 630 4 9 14 20 29 26 23 19 Case Axial Attenuator kg Fitted with pod Free area Dia Øa bØ Øc d Øe n approx kg approx m 2without pod 450 550 500 450 675 M10 8 50 73 0.159 500 600 560 500 750 M10 12 59 87 0.196 560 660 620 560 840 M10 12 70 102 0.246 630 730 690 630 940 M10 12 82 120 0.312 Stock Refa b c d Øe f g h i 10503450 384 24 315 315 12 14 155 250 238 10503500 425 24 315 315 12 14 135 280 268 10503560 475 24 355 355 12 14 155 310 298 10503630 520 24 400 400 12 14 175 345 333 ‘K’ factor loss 0.25 Stock Ref Øa b 10505450 525 3 10505500 595 3 10505560 655 3 10505 630 725 3 For more information on the ‘K’ factor, refer to General Information Section Mounting Feet Inlet Wire Guard

275 Accessories Dimensions (mm) AccessoriesIncludes 4 Anti Vibration Mounts, 2 Mounting Feet, 2 Flanges and 2 Flexible ConnectorsFor Manual control requiresSpeed Potentiometer 426332#4 required per fan xNot suitable Mounting Stock Ref Ancillary Pack Case Axial Attenuator Case Axial Attenuatorin Pod Mounting Feet Coupling Flange Inlet Wire Guard Anti Vibration Mounts# KAF45012 10513450 10514450 10500450 10503450 10506450 10505450 68MP033G KAF50012 10513500 10514500 10500500 10503500 10506500 10505500 68MP033G KAF56012 10513560 10514560 15000560 10503560 10506560 10505560 68MP033G KAF63012 10513630 10514630 10500630 10503630 10506630 10505630 68MP033G KAF45032 10513450 10514450 10500450 10503450 10506450 10505450 68MP033G KAF50032 10513500 10514500 10500500 10503500 10506500 10505500 68MP033G KAF56032 10513560 10514560 15000560 10503560 10506560 10505560 68MP033G KAF63032 10513630 10514630 10500630 10503630 10506630 10505630 68MP033GManual Starter eDemand Controls Stock Ref Starter Overload Single Phase InverterSingle Phase in 3Phase Out Inverter 3 Phase Inverter Voltage Control Transformer Control KAF45012 444744 444705 444171 x x 444165 10314113 KAF50012 444744 444705 444171 x x 444165 10314113 KAF56012 444744 444707 x x x x x KAF63012 444744 444707 x x x x x KAF45032 444747 444702 x 444177 444172 444166 10314304 KAF50032 444747 444702 x 444177 444173 444166 10314304 KAF56032 444747 444703 x 444177 444173 x x KAF63032 444747 444705 x x 444174 x x Coupling Flange Anti-Vibration Mounts Number of holes ØaØe Øc Ød n b inside dia. Stock Max Ref a Øb c d e Øf n load kg68MP033G 27 37 54 67 18.5 7 M8 23 Stock Ref No. Øa b Øc Ød Øe n 10506450 450 60 500 537 12 8 10506500 500 60 560 595 12 12 10506560 560 75 620 655 12 12 10506630 630 75 690 725 12 12 4 required per fan

276 Bifurcated Case Axial Fans (BIFA) •Sizes 250 to 1000 dia •Motors protected to IP55 •Motor insulation Class ‘F’ •Maximum ambient temperature 200˚C •Speed controllable via transformer or inverter (when theambient air temperature is not higher than 60˚C) •IP55 terminal box •Suitable for relative humidity levels up to 95% RH •Manufactured to BS EN ISO 9001 •Performance tested to BS 848 parts 1, 2 and ISO 5801 •2 Year Guarantee The Bifurcated Case Axial range has been specifically developed to meet the need for an axial fan which can handle atmospheres normally detrimental to the life of the fan motor. By isolating the motor from the system airstream, the bifurcated fan can handle a wide variety of saturated and dust-laden atmospheres, heated air and hot gases. The range has a split airway with a direct driven motor operating in ambient air within the motor compartment.They are suitable, as standard, for handling air temperatures up to +200˚C. The Bifurcated Case Axial Fan range has a number of accessories available which include: Axial Ancillary Pack, Attenuator, Wire Inlet Guard, Coupling Flanges, Mounting Feet, AV Mounts and Speed Controllers. Motors The motors are specially selected to operate within the motor compartment with the airstream in the duct system, at an elevated temperature. Motors are of the B3 foot mounting type, totally enclosed and fan cooled. Being foot mounted the motors can, in the event of a failure, be readily interchanged with a comparable frame size from a wide range of manufacturers to cover temperatures of up to 200˚C. Where indicated, the motor is suitable for speed control by either an inverter or a 5-step auto transformer speed controller when the ambient air temperature is not higher than 60˚C. Electrical Single phase 220-240V/50 Hz supply are available in two sizes 250 and 315 dia. in either 2 or 4 pole versions.Three phase 380-440V/50Hz supply are available in nine sizes 250, 315, 400, 500, 630, 710, 800, 900 and 1000 dia. in either 2 or 4 pole versions (710, 800, 900 and 1000 dia are only available as 4 pole). Impellers and Casing The aluminium alloy impellers are die cast and have an adjustable pitch which allows a wide range of air outputs to be selected. All the casings are manufactured in steel and hot dipped galvanised to BS EN ISO 1461 after fabrication. Motor mountings and fixings used in the assembly of the fan are zinc plated and passivated. Form of Running Bifurcated fans have arrows showing the direction of the impeller rotation and airflow. All models are Form B running. Terminal Box To IP55, protected against dust and water jets from any angle, allowing outside applications. Performance Tested to BS 848 Part 1 & 2.Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10–5Pa (20 micro-Pascal). The inlet and outlet sound power level spectra figures are dB with a reference of 10–12 Watts (1 pico-Watt). Cooling External cooling is provided by a fan mounted at the non-drive end of the motor, protected by a cover with a grid air intake. The airflow, guided by the fan cover, is directed longitudinally on the entire periphery of the motor in the channels formed by the frame ribs. Adequate space is provided within the motor compartment to ensure a plentiful supply of cooling air.The air within the motor compartment must not exceed 40˚C. For ambients in excess of this, please consult our Technical Services Department for further information.

277 BIFA63 - BIFA100 b e No. OF HOLES C P.C.D. C L f Ø HOLES Air Flow .(B Form) . hØ Rotation aØ Inside dØ Over Flanges g AØ Inside D Ø Over Flanges B G E No OF HOLES C P.C.D. C L F Ø HOLES Air Flow .(B Form) . Rotation Fan Dimensions (mm) BIFA25 - BIFA50 Model No. Pole Phase Pitch Angle aØ b c d e f g hØ Approx. Weight kgBIFA25 2&4 1&3 25-40 250 535 302 328 8 10 240 452 30BIFA31 2&4 1&3 10-38 315 535 355 385 8 10 240 452 35BIFA40 2&4 1&3 10-38 400 625 450 480 8 10 335 585 49 BIFA45 2&4 1&3 10-40 450 625 500 535 8 12 360 650 60BIFA504 1&3 10-40 500 660 560 590 12 12 360 695 66BIFA502 3 10-40 500 710 560 590 12 12 360 695 87 Model No. Pole Phase Pitch Angle a b c d e f g Approx.Weight kg BIFA56 2&4 3 10-40 560 800 604 644 12 12 350 80 BIFA63 2&4 3 10-40 630 790 690 728 12 12 400 106BIFA71 4 3 10-40 710 800 754 784 16 12 435 120 BIFA80 4 3 10-40 800 880 860 890 16 12 450 155 BIFA90 4 3 10-40 900 900 970 1038 16 14 535 170 BIFA100 4 3 10-40 1000 1000 1070 1138 16 14 575 275

278 1 40° 1 35° 1 30° 1 25° BIFA25 - 1 & 3 Phase - 2 Pole Performance Guide1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 50 100 150 200 250kW@3m 250 BIFA251225 BIFA253225 2 2800 IP55 1 25° 0.43 0.41 0.38 0.35 0.31 0.24 0.37 58 250 BIFA251230 BIFA253230 2 2800 IP55 1 30° 0.54 0.51 0.47 0.42 0.37 0.29 0.37 57 250 BIFA251235 BIFA253235 2 2800 IP55 1 35° 0.64 0.6 0.56 0.5 0.44 0.37 0.37 58 250 BIFA251240 BIFA253240 2 2800 IP55 1 40° 0.72 0.67 0.62 0.56 0.48 0.37 59 Sound Power Level Spectra dB (ref 10 -12Watts) Dia. 1 PhaseStock Ref 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 250 BIFA251225 BIFA253225 2 Inlet/Outlet 73 74 82 75 73 70 67 64 58 250 BIFA251230 BIFA253230 2 Inlet/Outlet 72 73 81 74 72 69 66 63 57 250 BIFA251235 BIFA253235 2 Inlet/Outlet 73 74 82 75 73 70 67 64 58 250 BIFA251240 BIFA253240 2 Inlet/Outlet 74 75 83 76 74 71 68 65 59 Performance Curve

279 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° BIFA31 - 1 & 3 Phase - 2 Pole Performance Guide1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 100 200 300 400kW@3m 315 BIFA311210 BIFA313210 2 2800 IP55 1 10° 0.58 0.52 0.43 0.27 0.08 0.37 65 315 BIFA311212 BIFA313212 2 2800 IP55 1 12° 0.63 0.57 0.48 0.33 0.11 0.37 65 315 BIFA311214 BIFA313214 2 2800 IP55 1 14° 0.69 0.63 0.54 0.38 0.13 0.37 65 315 BIFA311216 BIFA313216 2 2800 IP55 1 16° 0.76 0.69 0.6 0.43 0.16 0.37 63 315 BIFA311218 BIFA313218 2 2800 IP55 1 18° 0.83 0.76 0.65 0.48 0.19 0.37 61 315 BIFA311220 BIFA313220 2 2800 IP55 1 20° 0.9 0.82 0.71 0.53 0.21 0.37 61 315 BIFA311222 BIFA313222 2 2800 IP55 1 22° 0.96 0.87 0.76 0.58 0.37 62 315 BIFA311224 BIFA313224 2 2800 IP55 1 24° 1 0.92 0.8 0.62 0.37 63 315 BIFA311226 BIFA313226 2 2800 IP55 1 26° 1.05 0.97 0.85 0.65 0.55 63 315 BIFA311228 BIFA313228 2 2800 IP55 1 28° 1.1 1.01 0.89 0.69 0.55 63 315 BIFA311230 BIFA313230 2 2800 IP55 1 30° 1.16 1.06 0.94 0.72 0.55 64 315 BIFA311232 BIFA313232 2 2800 IP55 1 32° 1.22 1.11 0.98 0.75 0.55 66 315 BIFA311234 BIFA313234 2 2800 IP55 1 34° 1.28 1.16 1.01 0.78 0.75 66 315 BIFA311236 BIFA313236 2 2800 IP55 1 36° 1.33 1.2 1.04 0.79 0.75 66 315 BIFA311238 BIFA313238 2 2800 IP55 1 38° 1.37 1.23 1.06 0.79 0.75 66 Sound Power Level Spectra dB (ref 10 -12Watts) Dia. 1 Phase Stock Ref 3 Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 315 BIFA311210 BIFA313210 2 Inlet/Outlet 83 82 82 79 81 80 76 68 65 315 BIFA311212 BIFA313212 2 Inlet/Outlet 83 82 82 79 81 80 76 68 65 315 BIFA311214 BIFA313214 2 Inlet/Outlet 83 82 82 79 81 80 76 68 65 315 BIFA311216 BIFA313216 2 Inlet/Outlet 81 80 80 77 79 78 74 66 63 315 BIFA311218 BIFA313218 2 Inlet/Outlet 79 78 78 75 77 76 72 64 61 315 BIFA311220 BIFA313220 2 Inlet/Outlet 79 78 78 75 77 76 72 64 61 315 BIFA311222 BIFA313222 2 Inlet/Outlet 80 79 79 76 78 77 73 65 62 315 BIFA311224 BIFA313224 2 Inlet/Outlet 81 80 80 77 79 78 74 66 63 315 BIFA311226 BIFA313226 2 Inlet/Outlet 81 80 80 77 79 78 74 66 63 315 BIFA311228 BIFA313228 2 Inlet/Outlet 81 80 80 77 79 78 74 66 63 315 BIFA311230 BIFA313230 2 Inlet/Outlet 82 81 81 78 80 79 75 67 64 315 BIFA311232 BIFA313232 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 315 BIFA311234 BIFA313234 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 315 BIFA311236 BIFA313236 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 315 BIFA311238 BIFA313238 2 Inlet/Outlet 84 83 83 80 82 81 77 69 66 Performance Curve

280 1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 100 200 300 400 500kW@3m 400 BIFA401210 BIFA403210 2 2800 IP55 1 10° 1.17 1.08 0.97 0.8 0.53 0.23 0.55 71 400 BIFA401212 BIFA403212 2 2800 IP55 1 12° 1.29 1.2 1.09 0.92 0.66 0.33 0.55 71 400 BIFA401214 BIFA403214 2 2800 IP55 1 14° 1.42 1.32 1.2 1.03 0.78 0.42 0.75 71 400 BIFA401216 BIFA403216 2 2800 IP55 1 16° 1.55 1.45 1.32 1.15 0.9 0.75 71 400 BIFA401218 BIFA403218 2 2800 IP55 1 18° 1.68 1.57 1.44 1.27 1.01 0.75 71 400 BIFA401220 BIFA403220 2 2800 IP55 1 20° 1.81 1.69 1.55 1.37 1.11 1.1 71 400 BIFA401222 BIFA403222 2 2800 IP55 1 22° 1.93 1.8 1.65 1.46 1.2 1.1 66 400 BIFA401224 BIFA403224 2 2800 IP55 1 24° 2.04 1.9 1.74 1.54 1.28 1.1 66 400 BIFA401226 BIFA403226 2 2800 IP55 1 26° 2.15 2 1.83 1.63 1.37 1.1 67 400 BIFA401228 BIFA403228 2 2800 IP55 1 28° 2.27 2.11 1.93 1.72 1.45 1.5 68 400 BIFA401230 BIFA403230 2 2800 IP55 1 30° 2.38 2.22 2.03 1.8 1.52 1.5 68 400 BIFA401232 BIFA403232 2 2800 IP55 1 32° 2.49 2.31 2.11 1.88 1.59 1.5 68 400 - BIFA403234 2 2800 IP55 1 34° 2.59 2.4 2.19 1.94 1.64 2.2 67 400 - BIFA403236 2 2800 IP55 1 36° 2.67 2.47 2.25 1.99 1.67 2.2 66 400 - BIFA403238 2 2800 IP55 1 38° 2.73 2.53 2.31 2.04 1.69 2.2 66 400 - BIFA403240 2 2800 IP55 1 40° 2.78 2.59 2.36 2.08 1.69 3 66 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° BIFA40 - 1 & 3 Phase - 2 Pole Dia. 1 Phase Stock Ref 3 Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 400 BIFA401210 BIFA403210 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 400 BIFA401212 BIFA403212 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 400 BIFA401214 BIFA403214 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 400 BIFA401216 BIFA403216 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 400 BIFA401218 BIFA403218 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 400 BIFA401220 BIFA403220 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 400 BIFA401222 BIFA403222 2 Inlet/Outlet 84 81 84 81 82 79 76 69 66 400 BIFA401224 BIFA403224 2 Inlet/Outlet 84 81 84 81 82 79 76 69 66 400 BIFA401226 BIFA403226 2 Inlet/Outlet 85 82 85 82 83 80 77 70 67 400 BIFA401228 BIFA403228 2 Inlet/Outlet 86 83 86 83 84 81 78 71 68 400 BIFA401230 BIFA403230 2 Inlet/Outlet 86 83 86 83 84 81 78 71 68 400 BIFA401232 BIFA403232 2 Inlet/Outlet 86 83 86 83 84 81 78 71 68 400 - BIFA403234 2 Inlet/Outlet 85 82 85 82 83 80 77 70 67 400 - BIFA403236 2 Inlet/Outlet 84 81 84 81 82 79 76 69 66 400 - BIFA403238 2 Inlet/Outlet 84 81 84 81 82 79 76 69 66 400 - BIFA403240 2 Inlet/Outlet 84 81 84 81 82 79 76 69 66

281 Sound Power Level Spectra dB (ref 10 -12Watts) Performance Guide3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 150 300 450 600 750kW@3m 450 BIFA453210 2 2880 IP55 1 10° 1.72 1.57 1.37 1.04 0.56 0.11 1.1 74 450 BIFA453212 2 2880 IP55 1 12° 1.89 1.74 1.54 1.22 0.73 0.21 1.1 73 450 BIFA453214 2 2880 IP55 1 14° 2.08 1.91 1.7 1.4 0.9 0.32 1.5 72 450 BIFA453216 2 2880 IP55 1 16° 2.27 2.1 1.88 1.57 1.5 71 450 BIFA453218 2 2880 IP55 1 18° 2.47 2.28 2.05 1.74 1.2 1.5 70 450 BIFA453220 2 2880 IP55 1 20° 2.65 2.46 2.21 1.88 1.35 2.2 70 450 BIFA453222 2 2880 IP55 1 22° 2.82 2.61 2.35 2.01 1.49 2.2 70 450 BIFA453224 2 2880 IP55 1 24° 2.99 2.76 2.48 2.13 1.62 2.2 70 450 BIFA453226 2 2880 IP55 1 26° 3.15 2.91 2.61 2.25 1.75 2.2 70 450 BIFA453228 2 2880 IP55 1 28° 3.32 3.06 2.75 2.38 1.86 3 70 450 BIFA453230 2 2880 IP55 1 30° 3.49 3.21 2.89 2.5 1.97 3 70 450 BIFA453232 2 2880 IP55 1 32° 3.65 3.35 3.01 2.6 2.08 3 70 Performance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° BIFA45 - 3 Phase - 2 Pole Dia. 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 450 BIFA453210 2 Inlet/Outlet 92 89 92 89 90 87 84 77 74 450 BIFA453212 2 Inlet/Outlet 91 88 91 88 89 86 83 76 73 450 BIFA453214 2 Inlet/Outlet 90 87 90 87 88 85 82 75 72 450 BIFA453216 2 Inlet/Outlet 89 86 89 86 87 84 81 74 71 450 BIFA453218 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 BIFA453220 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 BIFA453222 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 BIFA453224 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 BIFA453226 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 BIFA453228 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 BIFA453230 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70 450 BIFA453232 2 Inlet/Outlet 88 85 88 85 86 83 80 73 70

282 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 150 300 450 600 750kW@3m 500 BIFA503210 2 2880 IP55 1 10° 2.34 2.11 1.82 1.41 0.77 0.02 1.5 74 500 BIFA503212 2 2880 IP55 1 12° 2.64 2.39 2.09 1.68 1.06 0.12 1.5 73 500 BIFA503214 2 2880 IP55 1 14° 2.93 2.67 2.36 1.95 1.33 0.26 2.2 72 500 BIFA503216 2 2880 IP55 1 16° 3.21 2.94 2.62 2.2 1.58 2.2 71 500 BIFA503218 2 2880 IP55 1 18° 3.48 3.19 2.86 2.44 1.8 2.2 71 500 BIFA503220 2 2880 IP55 1 20° 3.73 3.43 3.09 2.66 2.01 3 71 500 BIFA503222 2 2880 IP55 1 22° 3.96 3.66 3.31 2.87 2.21 3 71 500 BIFA503224 2 2880 IP55 1 24° 4.19 3.88 3.52 3.07 2.4 3 71 500 BIFA503226 2 2880 IP55 1 26° 4.42 4.11 3.73 3.26 2.58 4 71 500 BIFA503228 2 2880 IP55 1 28° 4.66 4.33 3.94 3.45 2.74 4 72 500 BIFA503230 2 2880 IP55 1 30° 4.9 4.54 4.13 3.62 2.88 4 72 500 BIFA503232 2 2880 IP55 1 32° 5.12 4.72 4.28 3.76 3 5.5 72 500 BIFA503234 2 2880 IP55 1 34° 5.3 4.88 4.41 3.87 3.08 5.5 72 500 BIFA503236 2 2880 IP55 1 36° 5.45 5 4.52 3.94 5.5 72 500 BIFA503238 2 2880 IP55 1 38° 5.55 5.11 4.61 3.97 7.5 72 500 BIFA503240 2 2880 IP55 1 40° 5.64 5.21 4.69 3.98 7.5 72 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° BIFA50 - 3 Phase - 2 Pole Dia. 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 500 BIFA503210 2 Inlet/Outlet 93 84 91 91 91 87 85 78 74 500 BIFA503212 2 Inlet/Outlet 92 83 90 90 90 86 84 77 73 500 BIFA503214 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 BIFA503216 2 Inlet/Outlet 90 81 88 88 88 84 82 75 71 500 BIFA503218 2 Inlet/Outlet 90 81 88 88 88 84 82 75 71 500 BIFA503220 2 Inlet/Outlet 90 81 88 88 88 84 82 75 71 500 BIFA503222 2 Inlet/Outlet 90 81 88 88 88 84 82 75 71 500 BIFA503224 2 Inlet/Outlet 90 81 88 88 88 84 82 75 71 500 BIFA503226 2 Inlet/Outlet 90 81 88 88 88 84 82 75 71 500 BIFA503228 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 BIFA503230 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 BIFA503232 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 BIFA503234 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 BIFA503236 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 BIFA503238 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72 500 BIFA503240 2 Inlet/Outlet 91 82 89 89 89 85 83 76 72

283 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 200 400 600 800 1000 1200 1400kW@3m 560 BIFA563210 2 2880 IP55 1 10° 3.01 2.8 2.56 2.25 1.85 1.36 0.79 0.09 4 79 560 BIFA563212 2 2880 IP55 1 12° 3.44 3.2 2.93 2.59 2.18 1.69 1.11 0.35 4 79 560 BIFA563214 2 2880 IP55 1 14° 3.87 3.61 3.31 2.95 2.52 1.99 1.37 0.53 4 79 560 BIFA563216 2 2880 IP55 1 16° 4.3 4.04 3.73 3.36 2.88 2.27 5.5 79 560 BIFA563218 2 2880 IP55 1 18° 4.73 4.48 4.18 3.79 3.25 2.53 5.5 79 560 BIFA563220 2 2880 IP55 1 20° 5.15 4.91 4.61 4.21 3.65 2.83 7.5 79 560 BIFA563222 2 2880 IP55 1 22° 5.54 5.3 5 4.61 4.05 3.21 7.5 79 560 BIFA563224 2 2880 IP55 1 24° 5.94 5.67 5.36 4.98 4.45 3.62 7.5 79 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° BIFA56 - 3 Phase - 2 Pole Dia. 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 560 BIFA563210 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 BIFA563212 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 BIFA563214 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 BIFA563216 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 BIFA563218 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 BIFA563220 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 BIFA563222 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79 560 BIFA563224 2 Inlet/Outlet 94 89 97 98 94 91 86 82 79

284 Performance Guide3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 200 400 600 800 1000 1200 1400kW@3m 630 BIFA633210 2 2940 IP55 1 10° 4.51 4.2 3.87 3.47 3.01 2.44 1.7 0.72 5.5 84 630 BIFA633212 2 2940 IP55 1 12° 5 4.7 4.36 3.96 3.48 2.9 2.16 1.17 5.5 84 630 BIFA633214 2 2940 IP55 1 14° 5.53 5.22 4.88 4.48 3.98 3.38 2.61 1.6 7.5 84 630 BIFA633216 2 2940 IP55 1 16° 6.15 5.84 5.48 5.06 4.54 3.89 7.5 84 Sound Power Level Spectra dB (ref 10 -12Watts) Dia. 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 630 BIFA633210 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 630 BIFA633212 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 630 BIFA633214 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 630 BIFA633216 2 Inlet/Outlet 99 94 102 103 99 96 91 87 84 Performance Curve 1 16° 1 14° 1 12° 1 10° BIFA63 - 3 Phase - 2 Pole

285 Performance Guide1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 10 20 30 40 50 60kW@3m 250 BIFA251425 BIFA253425 4 1400 IP55 1 25° 0.22 0.21 0.2 0.18 0.17 0.15 0.13 0.25 46 250 BIFA251430 BIFA253430 4 1400 IP55 1 30° 0. 27 0.26 0.24 0.23 0.21 0.19 0.15 0.25 45 250 BIFA251435 BIFA253435 4 1400 IP55 1 35° 0.32 0.3 0.29 0.27 0.25 0.22 0.19 0.25 46 250 BIFA251440 BIFA253440 4 1400 IP55 1 40° 0.36 0.34 0.32 0.3 0.27 0.24 0.25 46 Sound Power Level Spectra dB (ref 10 -12Watts) Dia. 1 Phase Stock Ref 3 Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 250 BIFA251425 BIFA253425 4 Inlet/Outlet 61 68 64 63 61 58 55 52 46 250 BIFA251430 BIFA253430 4 Inlet/Outlet 60 67 63 62 60 57 54 51 45 250 BIFA251435 BIFA253435 4 Inlet/Outlet 61 68 64 63 61 58 55 52 46 250 BIFA251440 BIFA253440 4 Inlet/Outlet 61 68 64 63 61 58 55 52 46 Performance Curve 1 40° 1 35° 1 30° 1 25° BIFA25 - 1 & 3 Phase - 4 Pole

286 1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 20 40 60 80 100kW@3m 315 BIFA311410 BIFA313410 4 1400 IP55 1 10° 0.29 0.27 0.23 0.19 0.12 0.04 0.25 49 315 BIFA311412 BIFA313412 4 1400 IP55 1 12° 0.32 0.29 0.26 0.22 0.14 0.05 0.25 49 315 BIFA311414 BIFA313414 4 1400 IP55 1 14° 0.35 0.32 0.29 0.24 0.17 0.07 0.25 49 315 BIFA313416 BIFA313416 4 1400 IP55 1 16° 0.38 0.35 0.32 0.27 0.19 0.08 0.25 44 315 BIFA311418 BIFA313418 4 1400 IP55 1 18° 0.42 0.39 0.35 0.3 0.22 0.09 0.25 44 315 BIFA311420 BIFA313420 4 1400 IP55 1 20° 0.45 0.42 0.38 0.32 0.24 0.11 0.25 44 315 BIFA311422 BIFA313422 4 1400 IP55 1 22° 0.48 0.45 0.4 0.35 0.26 0.25 44 315 BIFA311424 BIFA313424 4 1400 IP55 1 24° 0.5 0.47 0.43 0.37 0.28 0.25 46 315 BIFA311426 BIFA313426 4 1400 IP55 1 26° 0.53 0.49 0.45 0.39 0.29 0.25 46 315 BIFA311428 BIFA313428 4 1400 IP55 1 28° 0.55 0.52 0.47 0.41 0.31 0.25 46 315 BIFA311430 BIFA313430 4 1400 IP55 1 30° 0.58 0.54 0.5 0.43 0.32 0.25 46 315 BIFA311432 BIFA313432 4 1400 IP55 1 32° 0.61 0.57 0.52 0.45 0.32 0.25 48 315 BIFA311434 BIFA313434 4 1400 IP55 1 34° 0.64 0.59 0.54 0.47 0.33 0.25 48 315 BIFA311436 BIFA313436 4 1400 IP55 1 36° 0.67 0.61 0.56 0.48 0.25 48 315 BIFA311438 BIFA313438 4 1400 IP55 1 38° 0.68 0.63 0.57 0.49 0.25 48 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° BIFA31 - 1 & 3 Phase - 4 Pole Dia. 1 Phase Stock Ref 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 315 BIFA311410 BIFA313410 4 Inlet/Outlet 66 69 67 64 65 63 58 48 49 315 BIFA311412 BIFA313412 4 Inlet/Outlet 66 69 67 64 65 63 58 48 49 315 BIFA311414 BIFA313414 4 Inlet/Outlet 66 69 67 64 65 63 58 48 49 315 BIFA313416 BIFA313416 4 Inlet/Outlet 61 64 62 59 60 58 53 43 44 315 BIFA311418 BIFA313418 4 Inlet/Outlet 61 64 62 59 60 58 53 43 44 315 BIFA311420 BIFA313420 4 Inlet/Outlet 61 64 62 59 60 58 53 43 44 315 BIFA311422 BIFA313422 4 Inlet/Outlet 61 64 62 59 60 58 53 43 44 315 BIFA311424 BIFA313424 4 Inlet/Outlet 63 66 64 61 62 60 55 45 46 315 BIFA311426 BIFA313426 4 Inlet/Outlet 63 66 64 61 62 60 55 45 46 315 BIFA311428 BIFA313428 4 Inlet/Outlet 63 66 64 61 62 60 55 45 46 315 BIFA311430 BIFA313430 4 Inlet/Outlet 63 66 64 61 62 60 55 45 46 315 BIFA311432 BIFA313432 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48 315 BIFA311434 BIFA313434 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48 315 BIFA311436 BIFA313436 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48 315 BIFA311438 BIFA313438 4 Inlet/Outlet 65 68 66 63 64 62 57 47 48

287 Dia. 1 PhaseStock Ref 1 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 400 BIFA401410 BIFA403410 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 400 BIFA401412 BIFA403412 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 400 BIFA401414 BIFA403414 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 400 BIFA401416 BIFA403416 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 400 BIFA401418 BIFA403418 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 400 BIFA401420 BIFA403420 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 400 BIFA401422 BIFA403422 4 Inlet/Outlet 66 68 67 63 64 61 57 48 48 400 BIFA401424 BIFA403424 4 Inlet/Outlet 66 68 67 63 64 61 57 48 48 400 BIFA401426 BIFA403426 4 Inlet/Outlet 68 70 69 65 66 63 59 50 50 400 BIFA401428 BIFA403428 4 Inlet/Outlet 69 71 70 66 67 64 60 51 51 400 BIFA401430 BIFA403430 4 Inlet/Outlet 70 72 71 67 68 65 61 52 52 400 BIFA401432 BIFA403432 4 Inlet/Outlet 70 72 71 67 68 65 61 52 52 400 BIFA401434 BIFA403434 4 Inlet/Outlet 69 71 70 66 67 64 60 51 51 400 BIFA401436 BIFA403436 4 Inlet/Outlet 69 71 70 66 67 64 60 51 51 400 BIFA401438 BIFA403438 4 Inlet/Outlet 68 70 69 65 66 63 59 50 50 400 BIFA401440 BIFA403440 4 Inlet/Outlet 68 70 69 65 66 63 59 50 50 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° 1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 20 40 60 80 100 120 140kW@3m 400 BIFA401410 BIFA403410 4 1400 IP55 1 10° 0.59 0.55 0.51 0.46 0.38 0.27 0.15 0.04 0.25 54 400 BIFA401412 BIFA403412 4 1400 IP55 1 12° 0.65 0.61 0.57 0.51 0.44 0.33 0.2 0.08 0.25 54 400 BIFA401414 BIFA403414 4 1400 IP55 1 14° 0.71 0.67 0.63 0.57 0.5 0.39 0.25 0.11 0.25 54 400 BIFA401416 BIFA403416 4 1400 IP55 1 16° 0.77 0.73 0.69 0.63 0.56 0.45 0.25 54 400 BIFA401418 BIFA403418 4 1400 IP55 1 18° 0.84 0.8 0.75 0.69 0.61 0.5 0.25 54 400 BIFA401420 BIFA403420 4 1400 IP55 1 20° 0.91 0.86 0.81 0.74 0.66 0.55 0.25 54 400 BIFA401422 BIFA403422 4 1400 IP55 1 22° 0.96 0.91 0.86 0.79 0.71 0.6 0.25 48 400 BIFA401424 BIFA403424 4 1400 IP55 1 24° 1.02 0.97 0.9 0.83 0.75 0.64 0.25 48 400 BIFA401426 BIFA403426 4 1400 IP55 1 26° 1.08 1.02 0.95 0.88 0.79 0.68 0.25 50 400 BIFA401428 BIFA403428 4 1400 IP55 1 28° 1.13 1.07 1 0.92 0.83 0.72 0.25 51 400 BIFA401430 BIFA403430 4 1400 IP55 1 30° 1.19 1.13 1.05 0.97 0.88 0.76 0.25 52 400 BIFA401432 BIFA403432 4 1400 IP55 1 32° 1.25 1.18 1.1 1.01 0.91 0.79 0.25 52 400 BIFA401434 BIFA403434 4 1400 IP55 1 34° 1.29 1.22 1.14 1.05 0.94 0.82 0.25 51 400 BIFA401436 BIFA403436 4 1400 IP55 1 36° 1.33 1.26 1.17 1.08 0.97 0.84 0.25 51 400 BIFA401438 BIFA403438 4 1400 IP55 1 38° 1.36 1.29 1.2 1.1 0.99 0.84 0.25 50 400 BIFA401440 BIFA403440 4 1400 IP55 1 40° 1.39 1.31 1.23 1.13 1.01 0.84 0.37 50 BIFA40 - 1 & 3 Phase - 4 Pole

288 Dia. 1 Phase Stock Ref 3 Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 450 BIFA451410 BIFA453410 4 Inlet/Outlet 77 79 78 74 75 72 68 59 59 450 BIFA451412 BIFA453412 4 Inlet/Outlet 77 79 78 74 75 72 68 59 59 450 BIFA451414 BIFA453414 4 Inlet/Outlet 77 79 78 74 75 72 68 59 59 450 BIFA451416 BIFA453416 4 Inlet/Outlet 77 79 78 74 75 72 68 59 59 450 BIFA451418 BIFA453418 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 BIFA451420 BIFA453420 4 Inlet/Outlet 73 75 74 70 71 68 64 55 55 450 BIFA451422 BIFA453422 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 BIFA451424 BIFA453424 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 BIFA451426 BIFA453426 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 BIFA451428 BIFA453428 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 BIFA451430 BIFA453430 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 BIFA451432 BIFA453432 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 BIFA451434 BIFA453434 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 BIFA451436 BIFA453436 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 BIFA451438 BIFA453438 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 450 BIFA451440 BIFA453440 4 Inlet/Outlet 72 74 73 69 70 67 63 54 54 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° 1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 40 80 120 160kW@3m 450 BIFA451410 BIFA453410 4 1400 IP55 1 10° 0.83 0.75 0.63 0.42 0.15 0.25 59 450 BIFA451412 BIFA453412 4 1400 IP55 1 12° 0.92 0.83 0.71 0.51 0.22 0.25 59 450 BIFA451414 BIFA453414 4 1400 IP55 1 14° 1.01 0.92 0.8 0.6 0.28 0.25 59 450 BIFA451416 BIFA453416 4 1400 IP55 1 16° 1.1 1.01 0.88 0.68 0.25 59 450 BIFA451418 BIFA453418 4 1400 IP55 1 18° 1.2 1.1 0.96 0.76 0.25 54 450 BIFA451420 BIFA453420 4 1400 IP55 1 20° 1.29 1.18 1.04 0.83 0.25 55 450 BIFA451422 BIFA453422 4 1400 IP55 1 22° 1.37 1.25 1.11 0.9 0.25 54 450 BIFA451424 BIFA453424 4 1400 IP55 1 24° 1.45 1.32 1.17 0.96 0.25 54 450 BIFA451426 BIFA453426 4 1400 IP55 1 26° 1.53 1.4 1.23 1.01 0.37 54 450 BIFA451428 BIFA453428 4 1400 IP55 1 28° 1.61 1.47 1.29 1.07 0.37 54 450 BIFA451430 BIFA453430 4 1400 IP55 1 30° 1.7 1.54 1.36 1.13 0.37 54 450 BIFA451432 BIFA453432 4 1400 IP55 1 32° 1.77 1.61 1.41 1.17 0.37 54 450 BIFA451434 BIFA453434 4 1400 IP55 1 34° 1.84 1.67 1.46 1.21 0.55 54 450 BIFA451436 BIFA453436 4 1400 IP55 1 36° 1.9 1.72 1.51 1.24 0.55 54 450 BIFA451438 BIFA453438 4 1400 IP55 1 38° 1.94 1.76 1.54 1.25 0.55 54 450 BIFA451440 BIFA453440 4 1400 IP55 1 40° 1.98 1.8 1.58 1.27 0.55 54 BIFA45 - 1 & 3 Phase - 4 Pole

289 Dia. 1 PhaseStock Ref 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 500 BIFA501410 BIFA503410 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 BIFA501412 BIFA503412 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 BIFA501414 BIFA503414 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 BIFA501416 BIFA503416 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 BIFA501418 BIFA503418 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 BIFA501420 BIFA503420 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 BIFA501422 BIFA503422 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 BIFA501424 BIFA503424 4 Inlet/Outlet 76 78 74 75 74 71 68 58 58 500 BIFA501426 BIFA503426 4 Inlet/Outlet 78 80 76 77 76 73 70 60 60 500 BIFA501428 BIFA503428 4 Inlet/Outlet 78 80 76 77 76 73 70 60 60 500 BIFA501430 BIFA503430 4 Inlet/Outlet 79 81 77 78 77 74 71 61 61 500 BIFA501432 BIFA503432 4 Inlet/Outlet 79 81 77 78 77 74 71 61 61 500 BIFA501434 BIFA503434 4 Inlet/Outlet 79 81 77 78 77 74 71 61 61 500 BIFA501436 BIFA503436 4 Inlet/Outlet 79 81 77 78 77 74 71 61 61 500 BIFA501438 BIFA503438 4 Inlet/Outlet 79 81 77 78 77 74 71 61 61 500 BIFA501440 BIFA503440 4 Inlet/Outlet 79 81 77 78 77 74 71 61 61 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° 1 Phase3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Stock Ref Poles rpmRatingRef 0 40 80 120 160kW@3m 500 BIFA501410 BIFA503410 4 1400 IP55 1 10° 1.14 1.01 0.84 0.58 0.18 0.25 58 500 BIFA501412 BIFA503412 4 1400 IP55 1 12° 1.28 1.15 0.97 0.72 0.3 0.25 58 500 BIFA501414 BIFA503414 4 1400 IP55 1 14° 1.42 1.28 1.1 0.85 0.42 0.25 58 500 BIFA501416 BIFA503416 4 1400 IP55 1 16° 1.56 1.41 1.22 0.97 0.25 58 500 BIFA501418 BIFA503418 4 1400 IP55 1 18° 1.69 1.53 1.34 1.09 0.25 58 500 BIFA501420 BIFA503420 4 1400 IP55 1 20° 1.82 1.65 1.45 1.19 0.37 58 500 BIFA501422 BIFA503422 4 1400 IP55 1 22° 1.93 1.76 1.56 1.29 0.37 58 500 BIFA501424 BIFA503424 4 1400 IP55 1 24° 2.04 1.87 1.66 1.39 0.37 58 500 BIFA501426 BIFA503426 4 1400 IP55 1 26° 2.15 1.97 1.76 1.48 0.37 60 500 BIFA501428 BIFA503428 4 1400 IP55 1 28° 2.27 2.08 1.86 1.56 0.55 60 500 BIFA501430 BIFA503430 4 1400 IP55 1 30° 2.38 2.18 1.95 1.64 0.55 61 500 BIFA501432 BIFA503432 4 1400 IP55 1 32° 2.49 2.27 2.02 1.71 0.55 61 500 BIFA501434 BIFA503434 4 1400 IP55 1 34° 2.58 2.34 2.08 1.76 0.55 61 500 BIFA501436 BIFA503436 4 1400 IP55 1 36° 2.65 2.4 2.13 1.78 0.75 61 500 BIFA501438 BIFA503438 4 1400 IP55 1 38° 2.7 2.46 2.17 1.77 0.75 61 500 BIFA501440 BIFA503440 4 1400 IP55 1 40° 2.74 2.5 2.2 0.75 61 BIFA50 - 1 & 3 Phase - 4 Pole

290 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 50 100 150 200 250 300kW@3m 560 BIFA563410 4 1400 IP55 1 10° 1.46 1.36 1.23 1.06 0.85 0.58 0.28 0.55 64 560 BIFA563412 4 1400 IP55 1 12° 1.67 1.55 1.41 1.23 1.01 0.74 0.43 0.55 64 560 BIFA563414 4 1400 IP55 1 14° 1.88 1.75 1.59 1.4 1.17 0.89 0.55 0.55 64 560 BIFA563416 4 1400 IP55 1 16° 2.09 1.96 1.8 1.59 1.34 0.55 64 560 BIFA563418 4 1400 IP55 1 18° 2.3 2.17 2.01 1.8 1.51 0.75 64 560 BIFA563420 4 1400 IP55 1 20° 2.5 2.38 2.22 2.01 1.69 0.75 64 560 BIFA563422 4 1400 IP55 1 22° 2.7 2.57 2.41 2.2 1.89 0.75 64 560 BIFA563424 4 1400 IP55 1 24° 2.89 2.75 2.59 2.38 2.09 1.1 64 560 BIFA563426 4 1400 IP55 1 26° 3.08 2.94 2.77 2.56 2.27 1.1 64 560 BIFA563428 4 1400 IP55 1 28° 3.29 3.13 2.95 2.73 2.43 1.1 64 560 BIFA563430 4 1400 IP55 1 30° 3.48 3.32 3.13 2.89 2.58 2.1 1.1 64 560 BIFA563432 4 1400 IP55 1 32° 3.66 3.49 3.29 3.04 2.72 2.21 1.5 64 560 BIFA563434 4 1400 IP55 1 34° 3.82 3.64 3.44 3.19 2.85 2.32 1.5 64 560 BIFA563436 4 1400 IP55 1 36° 3.99 3.8 3.58 3.32 2.97 1.5 64 560 BIFA563438 4 1400 IP55 1 38° 4.16 3.96 3.73 3.45 3.08 2.2 64 560 BIFA563440 4 1400 IP55 1 40° 4.34 4.12 3.87 3.57 3.17 2.2 64 BIFA56 - 3 Phase - 4 Pole Dia. 3 Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 560 BIFA563410 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563412 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563414 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563416 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563418 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563420 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563422 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563424 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563426 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563428 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563430 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563432 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563434 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563436 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563438 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64 560 BIFA563440 4 Inlet/Outlet 75 75 80 81 81 77 74 64 64

291 Sound Power Level Spectra dB (ref 10 -12Watts) Performance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° Performance Guide3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 50 100 150 200 250 300 350kW@3m 630 BIFA633410 4 1400 IP55 1 10° 2.15 1.99 1.81 1.59 1.33 0.99 0.54 0.55 64 630 BIFA633412 4 1400 IP55 1 12° 2.38 2.22 2.04 1.82 1.55 1.21 0.76 0.09 0.75 64 630 BIFA633414 4 1400 IP55 1 14° 2.64 2.47 2.29 2.06 1.79 1.43 0.97 0.29 0.75 64 630 BIFA633416 4 1400 IP55 1 16° 2.93 2.76 2.57 2.34 2.05 1.66 1.1 64 630 BIFA633418 4 1400 IP55 1 18° 3.24 3.08 2.88 2.63 2.32 1.9 1.1 64 630 BIFA633420 4 1400 IP55 1 20° 3.55 3.37 3.17 2.92 2.59 2.14 1.1 64 630 BIFA633422 4 1400 IP55 1 22° 3.82 3.63 3.42 3.17 2.85 2.38 1.5 65 630 BIFA633424 4 1400 IP55 1 24° 4.06 3.87 3.66 3.4 3.08 2.62 1.5 65 630 BIFA633426 4 1400 IP55 1 26° 4.32 4.12 3.9 3.63 3.3 2.84 1.5 65 630 BIFA633428 4 1400 IP55 1 28° 4.61 4.39 4.15 3.87 3.52 3.06 2.2 65 630 BIFA633430 4 1400 IP55 1 30° 4.88 4.65 4.4 4.1 3.74 3.27 2.2 65 630 BIFA633432 4 1400 IP55 1 32° 5.11 4.89 4.63 4.32 3.96 3.5 2.2 65 630 BIFA633434 4 1400 IP55 1 34° 5.34 5.1 4.84 4.54 4.17 3.7 2.2 65 630 BIFA633436 4 1400 IP55 1 36° 5.57 5.32 5.04 4.73 4.34 3.84 3 65 630 BIFA633438 4 1400 IP55 1 38° 5.82 5.55 5.25 4.9 4.48 3 65 630 BIFA633440 4 1400 IP55 1 40° 6.09 5.78 5.44 5.06 4.61 3 65 BIFA63 - 3 Phase - 4 Pole Dia. 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 630 BIFA633410 4 Inlet/Outlet 75 71 79 82 81 77 74 66 64 630 BIFA633412 4 Inlet/Outlet 75 71 79 82 81 77 74 66 64 630 BIFA633414 4 Inlet/Outlet 75 71 79 82 81 77 74 66 64 630 BIFA633416 4 Inlet/Outlet 75 71 79 82 81 77 74 66 64 630 BIFA633418 4 Inlet/Outlet 75 71 79 82 81 77 74 66 64 630 BIFA633420 4 Inlet/Outlet 75 71 79 82 81 77 74 66 64 630 BIFA633422 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 BIFA633424 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 BIFA633426 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 BIFA633428 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 BIFA633430 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 BIFA633432 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 BIFA633434 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 BIFA633436 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 BIFA633438 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65 630 BIFA633440 4 Inlet/Outlet 76 72 80 83 82 78 75 67 65

292 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 50 100 150 200 250 300 350 400kW@3m 710 BIFA713410 4 1420 IP55 1 10° 2.68 2.5 2.3 2.06 1.8 1.49 1.12 0.68 0.07 0.75 74 710 BIFA713412 4 1420 IP55 1 12° 2.99 2.81 2.61 2.37 2.09 1.76 1.37 0.9 0.27 1.1 74 710 BIFA713414 4 1420 IP55 1 14° 3.33 3.15 2.94 2.7 2.41 2.06 1.64 1.13 0.47 1.1 74 710 BIFA713416 4 1420 IP55 1 16° 3.72 3.53 3.32 3.07 2.77 2.4 1.5 74 710 BIFA713418 4 1420 IP55 1 18° 4.14 3.95 3.73 3.46 3.15 2.76 1.5 74 710 BIFA713420 4 1420 IP55 1 20° 4.53 4.33 4.1 3.82 3.49 3.08 2.2 71 710 BIFA713422 4 1420 IP55 1 22° 4.84 4.64 4.4 4.12 3.77 3.34 2.2 71 710 BIFA713424 4 1420 IP55 1 24° 5.12 4.9 4.66 4.36 4.01 3.57 2.2 71 710 BIFA713426 4 1420 IP55 1 26° 5.4 5.17 4.91 4.61 4.25 3.81 3 71 710 BIFA713428 4 1420 IP55 1 28° 5.69 5.45 5.17 4.86 4.49 4.06 3 71 710 BIFA713430 4 1420 IP55 1 30° 5.98 5.71 5.43 5.1 4.73 4.28 3 71 710 BIFA713432 4 1420 IP55 1 32° 6.24 5.97 5.67 5.32 4.92 4.42 4 71 710 BIFA713434 4 1420 IP55 1 34° 6.47 6.19 5.87 5.51 5.07 4 71 710 BIFA713436 4 1420 IP55 1 36° 6.67 6.37 6.04 5.66 4 71 710 BIFA713438 4 1420 IP55 1 38° 6.82 6.51 6.17 5.78 5.5 71 710 BIFA713440 4 1420 IP55 1 40° 6.96 6.63 6.28 5.5 71 BIFA71 - 3 Phase - 4 Pole Dia. 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 710 BIFA713410 4 Inlet/Outlet 89 84 92 92 90 85 82 75 74 710 BIFA713412 4 Inlet/Outlet 89 84 92 92 90 85 82 75 74 710 BIFA713414 4 Inlet/Outlet 89 84 92 92 90 85 82 75 74 710 BIFA713416 4 Inlet/Outlet 89 84 92 92 90 85 82 75 74 710 BIFA713418 4 Inlet/Outlet 89 84 92 92 90 85 82 75 74 710 BIFA713420 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 BIFA713422 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 BIFA713424 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 BIFA713426 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 BIFA713428 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 BIFA713430 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 BIFA713432 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 BIFA713434 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 BIFA713436 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 BIFA713438 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71 710 BIFA713440 4 Inlet/Outlet 86 81 89 89 87 82 79 72 71

293 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 100 200 300 400 500kW@3m 800 BIFA803410 4 1420 IP55 1 10° 3.84 3.53 3.13 2.63 1.99 1.24 2.2 80 800 BIFA803412 4 1440 IP55 1 12° 4.32 4 3.61 3.11 2.47 1.69 2.2 80 800 BIFA803414 4 1440 IP55 1 14° 4.76 4.44 4.03 3.51 2.84 2 3 80 800 BIFA803416 4 1440 IP55 1 16° 5.27 4.91 4.46 3.9 3 80 800 BIFA803418 4 1440 IP55 1 18° 5.81 5.4 4.91 4.3 3 80 800 BIFA803420 4 1440 IP55 1 20° 6.35 5.9 5.37 4.72 3 77 800 BIFA803422 4 1440 IP55 1 22° 6.88 6.4 5.84 5.17 4 78 800 BIFA803424 4 1440 IP55 1 24° 7.39 6.9 6.33 5.64 4 78 800 BIFA803426 4 1440 IP55 1 26° 7.89 7.38 6.8 6.1 5.5 78 800 BIFA803428 4 1440 IP55 1 28° 8.36 7.84 7.25 6.53 5.5 79 800 BIFA803430 4 1440 IP55 1 30° 8.8 8.26 7.64 6.89 7.5 79 800 BIFA803432 4 1440 IP55 1 32° 9.19 8.61 7.94 7.12 7.5 79 800 BIFA803434 4 1440 IP55 1 34° 9.51 8.9 8.17 7.25 7.5 79 800 BIFA803436 4 1440 IP55 1 36° 9.78 9.12 8.33 11 79 800 BIFA803438 4 1440 IP55 1 38° 9.99 9.29 8.44 11 79 800 BIFA803440 4 1440 IP55 1 40° 10.18 9.44 8.54 11 79 BIFA80 - 3 Phase - 4 Pole Dia. 3 Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 800 BIFA803410 4 Inlet/Outlet 93 87 93 98 96 93 88 80 80 800 BIFA803412 4 Inlet/Outlet 93 87 93 98 96 93 88 80 80 800 BIFA803414 4 Inlet/Outlet 93 87 93 98 96 93 88 80 80 800 BIFA803416 4 Inlet/Outlet 93 87 93 98 96 93 88 80 80 800 BIFA803418 4 Inlet/Outlet 93 87 93 98 96 93 88 80 80 800 BIFA803420 4 Inlet/Outlet 90 84 90 95 93 90 85 77 77 800 BIFA803422 4 Inlet/Outlet 91 85 91 96 94 91 86 78 78 800 BIFA803424 4 Inlet/Outlet 91 85 91 96 94 91 86 78 78 800 BIFA803426 4 Inlet/Outlet 91 85 91 96 94 91 86 78 78 800 BIFA803428 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79 800 BIFA803430 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79 800 BIFA803432 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79 800 BIFA803434 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79 800 BIFA803436 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79 800 BIFA803438 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79 800 BIFA803440 4 Inlet/Outlet 92 86 92 97 95 92 87 79 79

294 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 100 200 300 400 500 600kW@3m 900 BIFA903410 4 1440 IP55 1 10° 5.22 4.79 4.29 3.71 3 2.12 1 3 79 900 BIFA903412 4 1440 IP55 1 12° 5.84 5.43 4.95 4.38 3.69 2.82 1.7 4 80 900 BIFA903414 4 1440 IP55 1 14° 6.49 6.09 5.62 5.05 4.34 3.45 2.29 4 80 900 BIFA903416 4 1440 IP55 1 16° 7.21 6.79 6.29 5.69 4.94 4 80 900 BIFA903418 4 1440 IP55 1 18° 7.96 7.49 6.95 6.3 5.49 5.5 81 900 BIFA903420 4 1440 IP55 1 20° 8.69 8.18 7.59 6.89 6 5.5 81 900 BIFA903422 4 1440 IP55 1 22° 9.39 8.84 8.21 7.46 6.51 7.5 81 900 BIFA903424 4 1440 IP55 1 24° 10.04 9.47 8.81 8.02 7.04 7.5 81 900 BIFA903426 4 1440 IP55 1 26° 10.69 10.08 9.39 8.58 7.57 7.5 82 900 BIFA903428 4 1440 IP55 1 28° 11.31 10.69 9.97 9.14 8.12 11 82 900 BIFA903430 4 1440 IP55 1 30° 11.91 11.28 10.55 9.71 8.67 11 82 900 BIFA903432 4 1440 IP55 1 32° 12.5 11.85 11.12 10.26 11 82 900 BIFA903434 4 1440 IP55 1 34° 13.05 12.39 11.62 10.7 15 82 900 BIFA903436 4 1440 IP55 1 36° 13.54 12.82 11.97 10.93 15 82 900 BIFA903438 4 1440 IP55 1 38° 13.94 13.13 12.15 15 82 900 BIFA903440 4 1440 IP55 1 40° 14.27 13.36 12.26 15 82 BIFA90 - 3 Phase - 4 Pole Dia. 3 Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 900 BIFA903410 4 Inlet/Outlet 89 83 91 97 95 92 87 79 79 900 BIFA903412 4 Inlet/Outlet 90 84 92 98 96 93 88 80 80 900 BIFA903414 4 Inlet/Outlet 90 84 92 98 96 93 88 80 80 900 BIFA903416 4 Inlet/Outlet 90 84 92 98 96 93 88 80 80 900 BIFA903418 4 Inlet/Outlet 91 85 93 99 97 94 89 81 81 900 BIFA903420 4 Inlet/Outlet 91 85 93 99 97 94 89 81 81 900 BIFA903422 4 Inlet/Outlet 91 85 93 99 97 94 89 81 81 900 BIFA903424 4 Inlet/Outlet 91 85 93 99 97 94 89 81 81 900 BIFA903426 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 BIFA903428 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 BIFA903430 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 BIFA903432 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 BIFA903434 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 BIFA903436 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 BIFA903438 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82 900 BIFA903440 4 Inlet/Outlet 92 86 94 100 98 95 90 82 82

295 Sound Power Level Spectra dB (ref 10 -12Watts) Performance GuidePerformance Curve 1 32° 1 30° 1 28° 1 26° 1 24° 1 22° 1 20° 1 18° 1 16° 1 14° 1 12° 1 10° 1 34° 1 36° 1 38° 1 40° 3 PhaseIP Curve m 3 /s at PaMotor dBA Dia. Stock Ref Poles rpmRatingRef 0 100 200 300 400 500 600 700kW@3m 1000 BIFA1003410 4 1440 IP55 1 10° 6.3 5.78 5.18 4.47 3.6 2.49 1.12 4 89 1000 BIFA1003412 4 1440 IP55 1 12° 7.38 6.87 6.27 5.54 4.64 3.5 2.04 0.26 4 89 1000 BIFA1003414 4 1440 IP55 1 14° 8.46 7.94 7.33 6.57 5.64 4.45 2.88 0.86 5.5 89 1000 BIFA1003416 4 1440 IP55 1 16° 9.54 8.98 8.33 7.55 6.58 5.3 5.5 89 1000 BIFA1003418 4 1440 IP55 1 18° 10.57 9.97 9.29 8.47 7.45 6.06 7.5 89 1000 BIFA1003420 4 1440 IP55 1 20° 11.55 10.91 10.19 9.33 8.26 6.8 7.5 89 1000 BIFA1003422 4 1440 IP55 1 22° 12.46 11.79 11.04 10.15 9.04 7.59 7.5 89 1000 BIFA1003424 4 1440 IP55 1 24° 13.32 12.64 11.86 10.94 9.82 8.44 11 89 1000 BIFA1003426 4 1440 IP55 1 26° 14.13 13.45 12.67 11.75 10.63 11 89 1000 BIFA1003428 4 1440 IP55 1 28° 14.93 14.26 13.48 12.55 11.41 15 89 1000 BIFA1003430 4 1440 IP55 1 30° 15.73 15.05 14.25 13.29 12.11 15 89 1000 BIFA1003432 4 1440 IP55 1 32° 16.52 15.78 14.92 13.91 12.7 15 89 1000 BIFA1003434 4 1440 IP55 1 34° 17.26 16.44 15.5 14.42 18.5 89 1000 BIFA1003436 4 1440 IP55 1 36° 17.92 17.03 16.01 14.77 18.5 89 1000 BIFA1003438 4 1440 IP55 1 38° 18.53 17.57 16.44 14.97 18.5 89 1000 BIFA1003440 4 1440 IP55 1 40° 19.1 18.06 16.8 22 89 BIFA100 - 3 Phase - 4 Pole Dia. 3 PhaseStock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 1000 BIFA1003410 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003412 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003414 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003416 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003418 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003420 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003422 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003424 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003426 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003428 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003430 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003432 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003434 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003436 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003438 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89 1000 BIFA1003440 4 Inlet/Outlet 99 94 101 106 106 102 97 89 89

296 Electrical Details 1 Phase 4 Pole eDemand Controller Stock Ref rpm Pitch Angle Motor kW S.C. Amps F.L.C Amps Starting Method Starter Ref Overload Ref Transform Controller Voltage Control 1/3 PhaseInverter 3 Phase Inverter BIFA25 1440 25°-50° 0.25 5 2 D.O.L. 444744 444701 10314103 444164 - - BIFA31 1400 10°-40° 0.25 5 2 D.O.L. 444744 444701 10314103 444164 - - BIFA40 1400 10°-40° 0.55 11 3.9 D.O.L. 444744 444703 10314105 444164 - - BIFA45 1400 10°-40° 0.55 11 3.9 D.O.L. 444744 444703 10314105 444164 - - BIFA50 1400 10°-34° 0.55 11 3.9 D.O.L. 444744 444703 10314105 444164 - - BIFA50 1400 36°-40° 0.75 15 5.3 D.O.L. 444744 444704 10314107 444165 - - LCA125 1475 32°-34° 45 193 80.5 Star Delta - - - 1 Phase 2 Pole eDemand Controller Stock Ref rpm Pitch Angle Motor kW S.C. Amps F.L.C Amps Starting Method Starter Ref Overload Ref Transform Controller Voltage Control 1/3 PhaseInverter 3 Phase Inverter BIFA25 2800 25°-50° 0.37 8 2.6 D.O.L. 444744 444702 - - - - BIFA31 2800 10°-24° 0.37 8 2.6 D.O.L. 444744 444702 - - - - BIFA31 2800 26°-32° 0.55 14 3.6 D.O.L. 444744 444703 - - - - BIFA31 2800 34°-38° 0.75 16 4.5 D.O.L. 444744 444703 - - - - BIFA31 2800 40° 1.1 23 6.6 D.O.L. 444744 444704 - - - - BIFA40 2800 10°-18° 0.75 16 4.5 D.O.L. 444744 444703 - - - - BIFA40 2800 20°-24° 1.1 23 6.6 D.O.L. 444744 444704 - - - - BIFA40 2800 26°-32° 1.5 31 8.5 D.O.L. 444744 444705 - - - - 3 Phase 2 Pole eDemand Controller Stock Ref rpm Pitch Angle Motor kW S.C. Amps F.L.C Amps Starting Method Starter Ref Overload Ref Transform Controller Voltage Control 1/3 PhaseInverter 3 Phase Inverter BIFA25 2800 25°-50° 0.37 5.82 0.97 D.O.L. 444747 444700 - - 444177 444172 BIFA31 2800 10°-24° 0.37 5.82 0.97 D.O.L. 444747 444700 - - 444177 444172 BIFA31 2800 26°-32° 0.55 8.52 1.42 D.O.L. 444747 444701 - - 444177 444172 BIFA31 2800 34°-38° 0.75 10.62 1.77 D.O.L. 444747 444701 - - 444177 444172 BIFA31 2800 40° 1.1 15.06 2.51 D.O.L. 444747 444702 - - 444177 444173 BIFA40 2800 10°-18° 0.75 10.62 1.77 D.O.L. 444747 444701 - - 444177 444172 BIFA40 2800 20°-26° 1.1 15.06 2.51 D.O.L. 444747 444702 - - 444177 444173 BIFA40 2800 28°-32° 1.5 19.68 3.28 D.O.L. 444747 444702 - - 444177 444173 BIFA40 2800 34°-38° 2.2 27.66 4.61 D.O.L. 444747 444703 - - - 444174 BIFA40 2800 40° 3 42.2 6.03 D.O.L. 444747 444704 - - - 444174 BIFA45 2880 10°-12° 1.1 15.06 2.51 D.O.L. 444747 444702 - - 444177 444173 BIFA45 2880 14°-18° 1.5 19.68 3.28 D.O.L. 444747 444702 - - 444177 444173 BIFA45 2880 20°-26° 2.2 27.66 4.61 D.O.L. 444747 444703 - - - 444174 BIFA45 2880 28°-32° 3 42.2 6.03 D.O.L. 444747 444704 - - - 444174 BIFA50 2880 10°-12° 1.5 19.68 3.28 D.O.L. 444747 444702 - - 444177 444173 BIFA50 2880 14°-18° 2.2 27.66 4.61 D.O.L. 444747 444703 - - - 444174 BIFA50 2880 20°-24° 3 42.2 6.03 D.O.L. 444747 444704 - - - 444174 BIFA50 2880 26°-30° 4 59.1 7.88 D.O.L. 444747 444705 - - - 444175 BIFA50 2880 32°-36° 5.5 78.8 10.5 D.O.L. 444748 444706 - - - 444175 BIFA50 2880 38°-40° 7.5 106 14.1 D.O.L. 444748 444707 - - - 444176 BIFA56 2880 10°-14° 4 59.1 7.88 D.O.L. 444747 444705 - - - 444175 BIFA56 2880 16°-18° 5.5 78.8 10.5 D.O.L. 444748 444706 - - - 444175 BIFA56 2880 20°-24° 7.5 106 14.1 D.O.L. 444748 444707 - - - 444176 BIFA63 2940 10°-12° 5.5 78.8 10.5 D.O.L. 444748 444706 - - - 444175 BIFA63 2940 14°-16° 7.5 106 14.1 D.O.L. 444748 444707 - - - 444176 1 phase 2 pole are not speed controlable

297 3 Phase 4 Pole eDemand Controller Stock Ref rpm Pitch Angle Motor kW S.C. Amps F.L.C Amps Starting Method Starter Ref Overload Ref Transform Controller Voltage Control 1/3 PhaseInverter 3 Phase Inverter BIFA25 1440 25°-50° 0.25 5.04 0.84 D.O.L. 444747 444699 10314301 444166 444177 444172 BIFA31 1400 10°-40° 0.25 5.04 0.84 D.O.L. 444747 444699 10314301 444166 444177 444172 BIFA40 1400 10°-40° 0.55 9.48 1.58 D.O.L. 444747 444701 10314304 444166 444177 444172 BIFA45 1400 10°–40° 0.55 9.48 1.58 D.O.L. 444747 444701 10314304 444166 444177 444172 BIFA50 1400 10°-34° 0.55 9.48 1.58 D.O.L. 444747 444701 10314304 444166 444177 444172 BIFA50 1400 36°-40° 0.75 11.58 1.93 D.O.L. 444747 444701 10314304 444166 444177 444172 BIFA56 1400 10°-16° 0.55 9.48 1.58 D.O.L. 444747 444701 10314304 444166 444177 444172 BIFA56 1400 18°-22° 0.75 11.58 1.93 D.O.L. 444747 444701 10314304 444166 444177 444172 BIFA56 1400 24°-30° 1.1 15.84 2.64 D.O.L. 444747 444702 10314304 444166 444177 444173 BIFA56 1400 32°-36° 1.5 20.7 3.45 D.O.L. 444747 444702 10314304 444166 444177 444173 BIFA56 1400 38°-40° 2.2 33.9 4.84 D.O.L. 444747 444703 10314307 444167 - 444173 BIFA63 1400 10° 0.55 9.48 1.58 D.O.L. 444747 444701 10314304 444166 444177 444172 BIFA63 1400 12°-14° 0.75 11.58 1.93 D.O.L. 444747 444701 10314304 444166 444177 444172 BIFA63 1400 16°-20° 1.1 15.84 2.64 D.O.L. 444747 444702 10314304 444166 444177 444173 BIFA63 1400 22°-26° 1.5 20.7 3.45 D.O.L. 444747 444702 10314304 444166 444177 444173 BIFA63 1400 28°-34° 2.2 33.9 4.84 D.O.L. 444747 444703 10314307 444167 - 444174 BIFA63 1400 36°-40° 3 45.3 6.47 D.O.L. 444747 444704 10314311 444167 - 444174 BIFA71 1420 10° 0.75 11.58 1.93 D.O.L. 444747 444701 10314304 444166 444177 444172 BIFA71 1420 12°-14° 1.1 15.84 2.64 D.O.L. 444747 444702 10314304 444166 444177 444173 BIFA71 1420 16°-18° 1.5 20.7 3.45 D.O.L. 444747 444702 10314304 444166 444177 444173 BIFA71 1420 20°-24° 2.2 33.9 4.84 D.O.L. 444747 444703 10314307 444167 - 444174 BIFA71 1420 26°-30° 3 45.3 6.47 D.O.L. 444747 444704 10314311 444167 - 444174 BIFA71 1420 32°-36° 4 57.8 8.26 D.O.L. 444747 444705 10314311 444167 - 444175 BIFA71 1420 38°-40° 5.5 77 11 D.O.L. 444748 444706 - 444168 - 444175 BIFA80 1420 10°-12° 2.2 33.9 4.84 D.O.L. 444747 444703 10314307 444167 - 444174 BIFA80 1440 14°-20° 3 45.3 6.47 D.O.L. 444747 444704 10314311 444167 - 444174 BIFA80 1440 22°-24° 4 57.8 8.26 D.O.L. 444747 444705 10314311 444167 - 444175 BIFA80 1440 26°-28° 5.5 77 11 D.O.L. 444748 444706 - 444168 - 444175 BIFA80 1440 30°-34° 7.5 102.2 14.6 D.O.L. 444748 444707 - - - 444176 BIFA80 1440 36°-40° 11 52.3 20.9 Star Delta 444843 444707 - - - - BIFA90 1440 10° 3 45.3 6.47 D.O.L. 444747 444704 10314311 444167 - 444174 BIFA90 1440 12°-16° 4 57.8 8.26 D.O.L. 444747 444705 10314311 444167 - 444175 BIFA90 1440 18°-20° 5.5 77 11 D.O.L. 444748 444706 - 444168 - 444175 BIFA90 1440 22°-26° 7.5 102.2 14.6 D.O.L. 444748 444707 - - - 444176 BIFA90 1440 28°-32° 11 52.3 20.9 Star Delta 444843 444707 - - - - BIFA90 1440 34°-40° 15 75.3 30.1 Star Delta - - - - - - BIFA100 1440 10°-12° 4 57.8 8.26 D.O.L. 444747 444705 10314311 444167 - 444175 BIFA100 1440 14°-16° 5.5 77 11 D.O.L. 444748 444706 - 444168 - 444175 BIFA100 1440 18°-22° 7.5 102.2 14.6 D.O.L. 444748 444707 - - - 444176 BIFA100 1440 24°-26° 11 52.3 20.9 Star Delta 444843 444707 - - - - BIFA100 1440 28°-32° 15 75.3 30.1 Star Delta - - - - - - BIFA100 1440 34°-38° 18.5 86 34.3 Star Delta - - - - - - BIFA100 1440 40° 22 102 40.6 Star Delta - - - - - - Speed Controllers Used in conjunction with speed controllable fans Vent-Axia offers a choice of speed controllers, the traditional Five-Step Auto Transformer or the Inverter Speed Controller. The Five-Step-Auto Transformer provides five stepped speed settings without the electronic motor harmonic noise associated with all electronic or solid state type Speed Controllers. For eDemand Speed Controllers & Inverters see Accessories & Controls Section. Electrical Details

298 Inlet Wire Guard ‘K’ factor loss 0.25 Available for direct fixing to either side of the fan using flange sizing holes.Constructed to meet BS 848 Part 5. Number of holes Coupling Flange Rolled from mild steel.Dimensionally matched to fan flange and fixing holes.Stock Refa b c d e f g h i 10503250 232 24 180 240 10 14 115 146 130 10503315 275 24 224 240 10 14 115 177.5 167 10503400 348 24 280 300 12 14 135 225 213 10503450 384 24 315 360 12 14 155 250 238 10503500 425 24 315 360 12 14 135 280 268 10503560 475 24 355 355 12 14 155 310 298 10503630 520 24 400 400 12 14 175 345 333 10503710A 710 40 610 435 13 18 240 385 365 10503800A 800 40 700 480 13 18 262 430 410 10503900A 900 40 800 535 13 18 288 485 460 105031000A 1000 40 900 580 15 18 314 535 510 Stock Ref a b 10505250 245 3 10505315 380 3 10505400 475 3 10505450 525 3 10505500 595 3 10505560 655 3 10505630 725 3 10505710A 784 10 10505800A 870 10 10505900A 970 10 105051000A 1090 10 Accessory Dimensions (mm) Anti-Vibration MountsStock Ref a Ø b c Ø d Ø e Øn 10506250 327 55 292 254 10 4 10506315 385 30 355 315 10 8 10506400 480 45 450 400 12 8 10506450 530 60 500 450 12 8 10506500 590 0 560 500 12 12 10506560 650 75 620 560 12 12 10506630 720 75 690 630 12 1210506710A 794 40 770 710 12 1310506800A 884 40 860 800 12 1310506900A 1100 50 970 900 14 15 Max. Load Stock RefA B C D E F G H kg68MP033G 37 26 2767 54 7 3 M8 2368MP055B 37 26 27 67 54 7 3 M8 3668MP133G 57 46 35 95 76 10.5 4 M12 9168MP165R 57 46 35 95 76 10.5 4 M12 245 Mounting Feet Supplied as a pair Supplied as a set of 4 For more information on the ‘K’ factor, refer to General Information Section

299 Accessories Model Ref Mounting FeetStock Ref Inlet Wire GuardStock Ref Coupling FlangeStock Ref Ancillary PackStock Ref AttenuatorStock Ref Attenuator inc. PodStock Ref Anti-Vibration MountStock Ref BIFA25 10503250 10505250 10506250 10513250HT 10514250 - 68MP033G BIFA31 10503315 10505315 10506315 10513315HT 10514315 10500315 68MP033G BIFA40 10503400 10505400 10506400 10513400HT 10514400 10500400 68MP033G BIFA45 10503450 10505450 10506450 10513450HT 10514450 10500450 68MP033G BIFA50 10503500 10505500 10506500 10513500HT 10514500 10500500 68MP033G BIFA56 10503560 10505560 10506560 10513560HT 10514560 10500560 68MP033G BIFA63 10503630 10505630 10506630 10513630HT 10514630 10500630 68MP033G BIFA71 10503710A 10505710 10506710A 10513710HT 10514710A 10500710 68MP055B BIFA80 10503800A 10505800 10506800A 10513800HT 10514800A 10500800 68MP055B BIFA90 10503900A 10505900 10506900A 10513900HT 10514900A 10500900 68MP133G BIFA100 105031000A 105051000 105061000A 105131000HT 105141000A 105001000 68MP133G Typical Installation Vent-Axia attenuatorlength = 1 1 / 2x duct dia. DUCT Cased axial ancillary pack consists of 2 matching flanges, 2 flexible connections, 2 mounting feet, 4 anti-vibration mounts and 4 worm drive clips Pod available for extra attenuation Class ‘F’ motor insulation as standard Motors and Terminal Box protected to IP55 againstdust and water jets DUCT Axial Ancillary Pack consists of 2 Matching flanges, 2 Flexible Connectors, 2 Mounting Feet, 4 Anti Vibration Mounts and 4 Worm Drive ClipsSupplied as a set of 4

300 Fan Attenuator DetailsAn attenuator without Pod offers negligible resistance to air flow, and therefore the pressure loss can be considered to be the same as that for the equivalent length of ducting.Resistance Graph for Axial Attenuator with Pod1 RESISANCE (Pa) 40 0 MEAN DUCT VELOCITY m/s 10 20 30 0 2 3 4 5 6 7 8 9 10 Attenuator Insertion Loss Data Dia Stock Ref63 125 250 500 1k 2k 4k 8k kg approx 250 10514250 2 3 6 11 16 11 10 6 20 315 10514315 2 3 6 11 16 11 10 6 22 355 10514355 2 3 6 12 16 11 10 6 30 400 10514400 2 3 6 13 16 12 10 6 41 450 10514450 2 4 6 14 17 12 10 6 50 500 10514500 3 4 7 14 17 14 11 7 59 560 10514560 2 4 8 15 18 14 11 7 70 630 10514630 3 4 8 16 18 14 11 7 82 710 10514710 1 2 6 9 12 10 6 2 90 800 10514800 1 2 6 9 12 10 6 2 100 900 10514900 1 2 6 9 12 10 6 2 145 1000 10514000 1 2 6 9 12 10 6 2 184 Melinex lined attenuators are available on request Case Axial Attenuator Fitted with Pod Insertion Losses Dia Stock Ref63 125 250 500 1k 2k 4k 8k kg approx315 10500315 6 7 12 18 27 25 22 19 32 355 10500355 3 8 12 18 28 26 22 19 44 400 10500400 3 8 12 18 28 26 23 19 60 450 10500450 4 8 14 20 28 26 23 19 73 500 10500500 4 8 14 20 29 26 23 19 87 560 10500560 4 9 14 20 29 26 23 19 102 630 10500630 4 9 14 20 29 26 23 19 120 710 10500710 6 10 20 30 35 28 25 22 134 800 10500800 6 10 20 30 35 28 25 22 149 900 10500900 6 10 20 30 35 28 25 22 211 1000 105001000 6 10 20 30 35 28 25 22 267

301 Attenuator Dimensions (mm) StockModelRef aØ bØ cØ d eØ nBIFA25 10514250 350 292 254 375 M8 4BIFA31 10514315 415 355 315 475 M8 8BIFA35 10514355 455 395 355 540 M8 8BIFA40 10514400 500 450 400 600 M10 8BIFA45 10514450 550 500 450 675 M10 8BIFA50 10514500 600 560 500 750 M10 12BIFA56 10514560 660 620 560 810M10 12BIFA63 10514630 730 690 630 940 M10 12BIFA71 10514710 814 700 710 1070 M10 16BIFA80 10514800 900 860 796 1200 M10 16BIFA90 10514900 999 970 893 1350 M1016BIFA100 105141000 1108 1070 1070 1500 M10 16BIFA125 105141250 1350 1320 1250 1875 M10 20

In-line Fans The Vent-Axia in-line fan range features both box and tube fans designed to provide controllable environmental management solutions for commercial and industrial applications. With sizes ranging from 100mm to 710mm diameter and air volumes up to 5.63m 3 /soptimum performance at minimum running costs is assured. Where noise is an issue, our ACQ range has been updated to include backward curved fans for energy efficiency and a highly sound absorbent acoustic foam to minimise breakout and induct sound levels, yet maintain a low profile for ceiling void applications. Designed specifically to fully comply with the new Building Regulations for Commercial Kitchens and fully tested within the aggressive conditions observed in commercial kitchen applications the EKF range with its EC motor out of the airstream achieves low specific fan powers ( 1.0w/l/s), has a multi spigot arrangement and is suitable for 120°C in duct temperature.

Lo-Carbon Kitchen Box Fans (EKF) 304-311 New & Improved Acoustic In-Line Fans (ACQ) 312-317 Eco Mixed Flow Fans (eMF) 318-323 Powerflow In-Line Duct Fans (ACP) 324-327 EuroSeries (SDX) In-Line Centrifugal Duct Fans 328-331 Slimpak® (SLP) In-Line Centrifugal Duct Fans 332-335 Square Mixed Flow Fans (MFQ) 336-341

304 Lo-Carbon Kitchen Box Fan (EKF) •Energy efficient EC motor •120°C airstream rated •Sealed for life motor •Flexible installation, straight through or turn through 90° as standard •Internal or external mounting as standard •25mm Double skin casing •Integral IP65 Isolator •Simple potentiometer control •Compliant part L 2013 SFP for requirements for kitchenventilation systems Vent-Axia’s latest product offering in the Non Residential sector is a centrifugal box fan specifically designed for kitchen operation at elevated duct temperatures of up to 120°C. Working closely with our Engineering partner, the motor impeller arrangement has been specifically engineered to benefit from the efficiencies of an EC external rotor motor mounted out of the airstream to allow for operation at 120°C induct temperatures. Construction The casing is constructed from a framed 25mm double skin with acoustic insulation to minimise unit noise.With careful thought to maximising the installation possibilities from one unit Vent-Axia have managed to create a single unit that is suitable for both internal and external mounting as standard. In addition to this the duct configuration can be either straight blow through or turn through 90° and with the motor shaft either horizontal or vertical this enables the fan to be mounted in any orientation. Motor The Kitchen Box Fan range is powered by highly efficient, electronically commutated (EC) motors with permanent magnets, exceeding the minimum efficiency requirements for IE3 motors. All units are fully speed controllable via the onboard electronics utilising a 0-10V input signal. Motors and the onboard electronics are protected to IP54 as standard mounted and are out of the airstream. The combination of an EC high efficiency motor and a high efficiency backward curved impeller ensures ERP 2015 compliance. Impeller A backward curved welded Aluminium impeller is mounted on an extended shaft from the EC external motor. Motor and impeller is balanced as a finished assembly to G2.5 to ensure vibration free operation. Impeller matched to inlet cone for optimum performance. Speed Control By utilising EC motors the EKF range has been designed for simple Demand Ventilation control facilitated by use of a 0-10V potentiometer. This low voltage controller can then be mounted within the kitchen area thereby removing the risk of overheating or damaging the control cicuits. Performance The fan performance has been tested in accordance with ISO 5801 DIN 24163. Sound Levels Fan sound levels were measured in a reverberant chamber in accordance with EN ISO 3745. Published dB(A) figures are free field at a distance of 3m with hemispherical propagation at a reference level of 2x10 -5 . The sound power level spectra figures are dB with areference level of 10 -12Watts. Electrical Depending on unit size the EKF range is suitable for either single phase 220-240V 50Hz or three phase 380-414V 50Hz. All mains wiring is direct to the built in IP65 isolator mounted on the motor support plate providing simple and safe connection and operation.

305 Accessories A full range of accessories are available for the EKF range including: •Potentiometer speed controller (includedas standard) •Square to round duct connectors •Flexible connectors •Mounting support and A/V mount set •Weather cowl •Discharge louvre Online Documentation For digital catalogue information, fitting & wiring instructions and online fan selection programme visit www.vent-axia.com/ekfFan Dimensions (mm) A A B B C B B A D FRONT TOP BACK SIDE Unit can be mounted either motor shaft vertical or horizontal Access doors and discharge panel are interchangeable Model A B C D Weight (kg) EKF355E1 600 400 684 708 63 EKF400E1 700 500 784 826 81 EKF450E1 700 500 784 826 83.5 EKF450E3 700 500 784 826 83.5 EKF500E3 850 650 929 1017 130 EKF560E3 850 650 929 1017 132

306 Performance Guide 0 100 200 300 400 500 0.000 0.200 0.400 0.600 0.800 1.000 0.00 0.10 0.20 0.30 0.40 Air Volume m 3 /s Pressure Pa Absorbed Power kW EKF355E1 0.50 100%80%60%Airflow, m 3 /s @ Pa Fans Supply Speed 0 50 100 150 200 250 300 350 400 450 F.L.C. Voltage 100% m 3 /s 0.920 0.866 0.815 0.767 0.700 0.630 0.600 0.510 0.435 0.275 1.7 220V/1/ 50Hz kW 0.29 0.31 0.32 0.32 0.33 0.34 0.34 0.34 0.33 0.27 SFP 0.32 0.35 0.39 0.42 0.48 0.54 0.60 0.66 0.76 0.97 80% m 3 /s 0.737 0.665 0.605 0.538 0.455 0.360 0.140 1.0 kW 0.16 0.17 0.18 0.19 0.18 0.18 0.13 SFP 0.22 0.26 0.30 0.35 0.41 0.50 0.90 60% m 3 /s 0.554 0.475 0.375 0.230 0.7 kW 0.08 0.09 0.09 0.08 SFP 0.14 0.18 0.24 0.36 40% m 3 /s 0.368 0.230 0.5 kW 0.04 0.04 SFP 0.095 0.172Sound Data Octave Band Frequency SWL SPL Speed Test Mode 63 125 250 500 1K 2K 4K 8K dB(A) @ 3m 100% Intake 50 66 66 63 60 61 58 52 49 Discharge 48 66 67 67 69 66 62 55 Breakout 62 71 72 64 66 58 53 47 90% Intake 46 62 58 57 55 55 51 46 47 Discharge 42 61 59 61 63 60 55 48 Breakout 61 77 72 61 59 53 47 41 80% Intake 43 51 50 51 48 48 43 37 38 Discharge 36 39 48 52 56 55 52 46 Breakout 58 70 62 54 48 44 37 32 60% Intake 40 46 45 45 40 39 33 30 29 Discharge 34 36 44 43 40 39 35 30 Breakout 57 59 51 46 39 33 27 31

307 Performance Guide Air Volume m 3 /s Pressure Pa Absorbed Power kW 0 100 200 300 400 500 600 0.000 0.250 0.500 0.750 1.000 700 0.00 0.10 0.20 0.30 0.40 1.250 0.50 0.60 0.70 EKF400E1 100%80%60%40%Airflow, m 3 /s @ Pa Fans Supply Speed 0 50 100 150 200 250 300 350 400 450 500 600 F.L.C. Voltage 100% m 3 /s 1.206 1.160 1.115 1.065 1.020 0.965 0.907 0.845 0.765 0.685 0.586 0.175 3.0 220V/1/ 50Hz kW 0.53 0.55 0.56 0.58 0.59 0.60 0.61 0.61 0.60 0.59 0.56 0.33 SFP 0.44 0.47 0.50 0.55 0.58 0.62 0.67 0.72 0.79 0.86 0.96 1.90 80% m 3 /s 0.961 0.907 0.845 0.780 0.705 0.622 0.520 0.350 2.2 kW 0.28 0.30 0.31 0.32 0.32 0.32 0.31 0.26 SFP 0.29 0.33 0.36 0.40 0.45 0.51 0.59 0.75 60% m 3 /s 0.721 0.640 0.552 0.438 0.235 1.6 kW 0.13 0.14 0.15 0.14 0.12 SFP 0.18 0.22 0.27 0.33 0.51 40% m 3 /s 0.480 0.351 0.012 0.8 kW 0.06 0.05 0.03 SFP 0.11 0.16 2.50 Sound Data Octave Band Frequency SWL SPL Speed Test Mode 63 125 250 500 1K 2K 4K 8K dB(A) @ 3m 100% Intake 61 70 69 66 65 64 60 54 56 Discharge 58 70 73 72 73 69 64 57 Breakout 69 90 94 70 67 63 57 53 80% Intake 54 61 60 59 59 58 54 47 49 Discharge 50 61 65 66 67 63 58 51 Breakout 65 81 73 65 61 56 50 44 60% Intake 49 52 52 51 51 50 45 38 42 Discharge 45 52 57 59 59 54 49 45 Breakout 62 75 64 57 52 46 40 34 40% Intake 44 47 47 44 44 43 40 33 32 Discharge 40 46 47 45 45 43 42 35 Breakout 60 62 54 49 44 35 28 31

308 Performance Guide Air Volume m 3 /s 0 100 200 300 400 500 600 0.000 0.500 1.000 1.500 2.000 0.00 0.20 0.40 0.60 0.80 1.20 700 800 1.40 1.60 1.00 EKF450E1/EKF450E3 Pressure Pa Absorbed Power kW 100%80%60%40%E1 Model E3 Model Airflow, m 3 /s @ Pa Fans Supply Fans Supply Speed 0 50 100 150 200 250 300 350 400 450 500 550 600 700 F.L.C. Voltage F.L.C. Voltage 100% m 3 /s 1.602 1.555 1.505 1.458 1.408 1.356 1.290 1.220 1.160 1.092 1.012 0.925 0.840 0.462 5.2 220V/1/ 50Hz 1.8 400V/3/ 50Hz kW 0.99 1.01 1.03 1.04 1.05 1.07 1.07 1.07 1.06 1.06 1.05 1.03 1.00 0.76 SFP 0.62 0.65 0.68 0.71 0.75 0.79 0.83 0.87 0.92 0.97 1.04 1.12 1.19 1.64 80% m 3 /s 1.285 1.228 1.166 1.095 1.015 0.938 0.855 0.762 0..582 3.8 1.0 kW 0.51 0.53 0.54 0.55 0.55 0.55 0.55 0.54 0.49 SFP 0.40 0.43 0.46 0.50 0.55 0.59 0.64 0..71 0.84 60% m 3 /s 0.962 0.881 0.786 0.685 0.556 0.350 2.7 0.8 kW 0.23 0.24 0.25 0.24 0.24 0.20 SFP 0.24 0.27 0.31 0.35 0.43 0.58 40% m 3 /s 0.640 0.511 0.290 1.9 0.5 kW 0.08 0.09 0.08 SFP 0.13 0.17 0.26 Sound Data Octave Band Frequency SWL SPL Speed Test Mode 63 125 250 500 1K 2K 4K 8K dB(A) @ 3m 100% Intake 55 70 67 68 70 70 66 60 59 Discharge 54 70 77 77 78 75 70 63 Breakout 70 81 86 74 68 63 57 52 80% Intake 51 70 59 63 65 64 60 54 52 Discharge 46 48 68 69 72 72 69 64 Breakout 71 84 76 69 63 57 50 44 60% Intake 50 57 53 55 58 55 50 44 45 Discharge 36 45 56 62 64 65 60 54 Breakout 66 78 66 62 54 49 40 40 40% Intake 45 50 46 48 51 50 43 37 34 Discharge 31 42 48 53 55 56 52 38 Breakout 65 66 55 52 46 37 29 32

309 Performance GuideAir Volume m 3 /s 0 200 400 600 800 1000 1200 0.000 1.000 2.000 3.000 0 0.50 1.00 1.50 2.00 2.50 3.00 EKF500E3 0.500 1.500 2.500 Pressure Pa Absorbed Power kW 100%80%60%40% Airflow, m 3 /s @ Pa Fans Supply Speed 0 100 200 300 400 500 600 700 800 900 1000 F.L.C. Voltage 100% m 3 /s 2.543 2.450 2.320 2.190 2.075 1.935 1.835 1.700 1.458 1.250 0.539 3.6 400V/3/ 50Hz kW 1.71 1.76 1.82 1.89 1.96 2.03 2.07 2.10 2.00 1.85 1.25 SFP 0.67 0.72 0.78 0.86 0.95 1.05 1.13 1.23 1.37 1.53 2.29 80% m 3 /s 2.002 1.900 1.765 1.570 1.372 1.178 0.754 2.6 kW 0.88 1.01 1.04 1.05 1.04 1.02 0.87 SFP 0.44 0.53 0.59 0.67 0.76 0.87 1.16 60% m 3 /s 1.499 1.330 1.129 0.850 1.8 kW 0.40 0.47 0.49 0.46 SFP 0.26 0.35 0.43 0.54 40% m 3 /s 0.966 0.665 1.0 kW 0.18 0.22 SFP 0.19 0.33 Sound Data Octave Band Frequency SWL SPL Speed Test Mode 63 125 250 500 1K 2K 4K 8K dB(A) @ 3m 100% Intake 62 73 70 71 77 73 74 69 60 Discharge 60 76 82 80 83 81 79 75 Breakout 75 82 88 73 69 68 65 59 80% Intake 60 66 62 66 67 67 61 56 52 Discharge 56 67 72 74 75 71 66 60 Breakout 70 81 77 69 64 62 59 51 60% Intake 51 61 56 58 61 60 55 50 45 Discharge 50 62 65 66 68 64 60 55 Breakout 66 74 70 61 57 53 49 43 40% Intake 46 56 51 53 50 55 50 43 35 Discharge 43 55 56 57 59 55 51 48 Breakout 63 62 58 52 48 41 34 31

310 Performance GuideAir Volume m 3 /s 0 200 400 600 800 1000 1200 0.000 1.000 2.000 3.000 4.000 0 1.50 2.00 2.50 3.00 3.50 4.00 EKF560E3 Pressure Pa Absorbed Power kW 1.00 1300 100%80%60%40%Airflow, m 3 /s @ Pa Fans Supply Speed 0 100 200 300 400 500 600 700 800 900 1000 1100 F.L.C. Voltage 100% m 3 /s 3.693 3.570 3.440 3.310 3.135 2.940 2.725 2.507 2.278 2.004 1.650 0.930 5.5 400V/3/ 50Hz kW 2.58 2.75 2.92 3.00 3.10 3.14 3.17 3.20 3.15 3.08 2.83 2.16 SFP 0.70 0.77 0.85 0.91 0.99 1.07 1.16 1.27 1.38 1.54 1.72 2.32 80% m 3 /s 2.926 2.780 2.585 2.405 2.155 1.860 1.500 0.900 3.9 kW 1.33 1.45 1.56 1.61 1.62 1.60 1.51 1.20 SFP 0.45 0.52 0.60 0.67 0.75 0.86 1.01 1.33 60% m 3 /s 2.192 1.987 1.672 1.293 0.600 2.8 kW 0.59 0.65 0.69 0.69 0.49 SFP 0.27 0.33 0.42 0.53 0.81 40% m 3 /s 1.481 1.081 0.019 1.3 kW 0.27 0.32 0.11 SFP 0.18 0.30 5.74 Sound Data Octave Band Frequency SWL SPL Speed Test Mode 63 125 250 500 1K 2K 4K 8K dB(A) @ 3m 100% Intake 64 78 81 74 77 76 72 67 65 Discharge 62 76 83 83 83 81 76 70 Breakout 82 87 87 81 73 70 67 62 80% Intake 65 78 75 72 75 74 70 64 60 Discharge 63 77 79 81 81 79 74 67 Breakout 77 85 80 76 68 65 61 56 60% Intake 60 67 63 60 64 60 56 50 52 Discharge 56 65 67 70 70 66 60 54 Breakout 73 78 72 68 62 58 52 50 40% Intake 53 60 56 53 57 53 49 43 44 Discharge 48 55 57 60 60 56 51 46 Breakout 68 67 64 60 55 47 38 41

311 Unit Size Mounting Bracket & A/V Mount Set Flexible Connector Square to Circular Duct Transformation Section Discharge Cowl Weather Roof EKF355 EKFMF355 EKFFC355 EKFTP35-35 EKFDC355 EKFWR355 EKF400 EKFMF400 EKFFC400 EKFTP40-40 EKFDC400 EKFWR400 EKF450 EKFMF400 EKFFC400 EKFTP40-45 EKFDC400 EKFWR400 EKF500 EKFMF500 EKFFC500 EKFTP50-50 EKFDC500 EKFWR500 EKF560 EKFMF500 EKFFC500 EKFTP50-56 EKFDC500 EKFWR500 Mounting Bracket & A/V Mount Set Stock Ref A B C DØ E F G HØ I J K EKFMF355 600 100 400 13 25 700 750 9 30 100 35 EKFMF400 700 100 500 13 25 800 850 9 30 100 35 EKFMF400 700 100 500 13 25 800 850 9 30 100 35 EKFMF500 850 100 650 13 25 950 1000 9 30 100 35 EKFMF500 850 100 650 13 25 950 1000 9 30 100 35 Accessories Dimensions A B C E F G DØ HØ J I K Square to Circular Duct Transformation Section Stock Ref A B C DØ E F G H EKFTP35-35 600 100 400 348 50 400 540 570 EKFTP40-40 700 100 500 398 50 400 640 670 EKFTP40-45 700 100 500 448 50 400 640 670 EKFTP50-50 850 100 650 498 50 400 790 820 EKFTP50-56 850 100 650 558 50 400 790 820 A C B DØ E F H G Flexible Connector Stock Ref A B C D EØ F G EKFFC355 600 100 400 34 8 570 150 EKFFC400 700 100 500 34 8 670 150 EKFFC500 850 100 650 34 8 820 150 B C F D G E A Note: weather roof and cowl dimensions on application Accessories

312 NEW Acoustic In-Line Fans (ACQ) •Acoustically treated housing, Class ‘O’ rated, sandwichconstruction selected for maximum noise absorption •Motors protected to IP44 •Motor insulation Class ‘B’ •Maximum operating temperature 50˚C •Standard Thermal Overload Protection •Aluzinc construction for internal or external mounting as standard •All models speed controllable •Manufacture controlled to BS EN 1S0 9001 •Performance tested to ISO 5801 The ACQ fans feature an acoustic foam of dual density sandwich construction specially selected for maximum sound absorption and quiet operation. The housing is designed to be as compact as possible for concealed false ceiling applications.Manufactured in Aluzinc sheet metal, with integral anchorage points to allow the fan to be suspended at any angle, via drop rods or anti vibration mounts, ensuring a quick and easy solution to installation of the in-line acoustic fans. The access panel is easily removed for inspection. The full range of Acoustic fans manufactured from Aluzinc and as such are suitable for both internal and external mounting as standard. Ten models are available in sizes 100, 125, 150, 160, 200, 250, 315, 400 and 500, providing air volumes from 0.075m 3 /s to 1.609m 3 /s(270m 3 /h to 5,792 m 3 /h) at free air. Designed for pressures up to 550Pa. Motors At the heart of the range is a proven external rotor motor and backward curved impeller selected for low noise and high efficiency impeller assembly specially selected for its performance. The assembly is dynamically balanced to ISO 1940. Motors are rated to IP44 according to BS EN 60529. Ball bearings are greased for life and allow the fan to run at any angle. Insulation is Class ‘B’ (from -15˚C to +50˚C). All Acoustic fans are suitable for speed control with either an Electronic or Auto Transformer. An Auto Transformer is recommended to ensure minimum noise levels during speed control so eliminating any possibility of motor harmonic noise. Terminal Box An IP54 Terminal Box is supplied with all models with 20mm cable gland entry.Sound and Performance Tested to ISO5801. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10 –5 Pa (20 micro-Pascal). The inlet, outlet and breakout soundpower level spectra figures are dB with a reference of 10 –12Watts (1pico-watt). Electrical The ACQ range is supplied with motors wound to suit a 230V/1ph/50Hz supply capacitor start and run. Quality Assurance Design and manufacture is in accordance with BS EN ISO 9001.

313 Fan Dimensions (mm) A B C D E Side Front Top F G H I Stock Ref. A B C D E F G H I kg ACQ10012D 190 310 400 100 460 94 111 380 275 11 ACQ12512D 190 310 400 125 460 94 111 380 275 11 ACQ15012D 190 310 400 150 460 94 111 380 275 11 ACQ16012D 190 310 400 160 460 94 111 380 275 11 ACQ20012D 285 364 455 200 515 141 127 435 330 17 ACQ25012D 285 364 455 250 515 141 127 435 330 17 ACQ31512LD 348 404 455 315 515 173 182 435 370 21 ACQ31514HD 456 572 730 315 795 227 243 710 540 45 ACQ40014D 456 572 730 315 795 227 243 710 540 46 ACQ50014D 575 769 918 500 1006 286 326 898 735 77

314 Performance Curves 0 100 200 300 400 120 140 90 60 30 0 500 00.05 0.10 0.15 0.20 0.25 0.30Pressure Pa Absorbed Power kW 1 3 4 4 1 1 1 2 4 5Airflow, m 3 /s @ PaMotor Phase Stock Ref r.p.m CurveRef. 0 50 100 150 200 300 400 Motor kW S.C. Amps F.L.C Amps dBA @ 3m 1 ACQ10012D 2350 1 m³/s 0.07 0.06 0.06 0.05 0.04 0.03 0.05 0.37 0.23 31 kW 51.99 51.80 51.47 50.94 50.16 47.37 1 ACQ12512D 2350 2 m³/s 0.07 0.06 0.06 0.05 0.04 0.02 0.05 0.37 0.23 32 kW 52.03 50.99 50.57 50.04 49.03 45.11 1 ACQ15012D 2350 3 m³/s 0.13 0.11 0.09 0.07 0.06 0.05 0.37 0.23 32 kW 53.61 52.95 53.15 52.37 50.92 1 ACQ16012D 2350 4 m³/s 0.13 0.11 0.09 0.07 0.06 0.05 0.37 0.23 32 kW 53.61 52.95 53.15 52.37 50.92 1 ACQ20012D 2700 5 m³/s 0.25 0.23 0.21 0.18 0.15 0.10 0.06 0.09 0.85 0.38 34 kW 108.90 111.86 114.29 114.83 113.00 104.99 91.40 Sound Data Stock Ref Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m ACQ10012D Inlet 53 59 68 58 50 45 34 33 41 Outlet 54 57 63 59 60 54 49 42 43 Breakout 46 51 58 48 41 38 31 32 31 ACQ12512D Inlet 51 65 73 62 51 46 36 36 45 Outlet 52 62 67 64 62 55 52 45 46 Breakout 48 52 59 49 41 40 33 32 32 ACQ15012D Inlet 54 60 70 59 52 46 38 36 42 Outlet 56 58 63 58 59 56 49 43 43 Breakout 48 52 58 51 43 38 31 33 32 ACQ16012D Inlet 54 60 70 59 52 46 38 36 42 Outlet 56 58 63 58 59 56 49 43 43 Breakout 48 52 58 51 43 38 31 33 32 ACQ20012D Inlet 60 65 63 68 58 55 54 46 46 Outlet 60 63 68 72 68 67 62 53 53 Breakout 53 58 57 55 46 41 35 34 34

315 Performance Curves 0 100 200 300 400 800 1000 600 400 200 0 500 00.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 Pressure Pa Absorbed Power kW 1 3 1 2 1 1 4 4 4 5Airflow, m 3 /s @ PaMotorPhase Stock Ref r.p.m CurveRef. 0 50 100 150 200 300 400 Motor kW S.C. Amps F.L.C Amps dBA @ 3m 1 ACQ25012D 2500 1 m³/s 0.32 0.30 0.27 0.25 0.23 0.18 0.13 0.16 1.25 0.68 34 kW 133.39 136.43 140.64 144.46 147.08 147.22 139.54 1 ACQ31512LD 2700 2 m³/s 0.37 0.35 0.32 0.30 0.27 0.23 0.19 0.23 2.4 0.97 36 kW 201.27 206.80 212.03 216.55 220.09 223.66 221.47 1 ACQ31514HD 1330 3 m³/s 0.85 0.78 0.69 0.59 0.49 0.30 0.27 2.2 1.18 36 kW 207.16 222.23 236.08 244.79 244.76 219.55 1 ACQ40014D 1340 4 m³/s 1.11 1.05 0.99 0.92 0.83 0.55 0.34 0.47 5.9 2.33 38 kW 419.86 440.84 455.95 465.28 467.96 435.07 374.55 1 ACQ50014D 1330 5 m³/s 1.59 1.51 1.40 1.28 1.15 0.92 0.72 0.73 6.27 3.21 46 kW 602.49 617.86 638.71 662.42 682.88 700.49 689.13 Sound Data Stock Ref Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m ACQ25012D Inlet 64 74 72 67 57 55 56 53 48 Outlet 64 74 75 69 70 71 65 64 56 Breakout 52 57 68 52 44 40 36 38 39 ACQ31512LD Inlet 72 69 79 67 63 62 60 61 52 Outlet 69 68 74 70 70 71 66 70 56 Breakout 60 61 67 56 55 51 44 42 41 ACQ31514HD Inlet 66 78 68 60 52 49 42 40 45 Outlet 67 75 77 71 69 62 56 49 53 Breakout 53 67 61 52 47 41 34 33 36 ACQ40014D Inlet 73 82 79 68 62 55 50 49 52 Outlet 72 78 78 75 74 66 58 53 57 Breakout 57 68 61 56 51 45 39 34 38 ACQ50014D Inlet 77 85 78 71 64 62 54 52 54 Outlet 74 83 82 78 77 72 64 58 61 Breakout 66 78 71 62 56 49 42 41 46

316 Accessories Electronic Auto eDemand Std Fan Controller Transformer Voltage Control Size Stock Ref Stock Ref Stock Ref Stock Ref 100 ACQ10012D W10303102M 10314103 444164 125 ACQ12512D W10303102M 10314103 444164 150 ACQ15012D W10303102M 10314103 444164 160 ACQ16012D W10303102M 10314103 444164 200 ACQ20012D W10303102M 10314103 444164 250 ACQ25012D W10303102M 10314103 444164 315 ACQ31512LD W10303102M 10314103 444164 315 ACQ31514HD 10303103 10314103 444164 400 ACQ40014D 10303106 10314105 444164 500 ACQ50014D 10303106 10314105 444164 Anti- Vibration Duct Air Filter Bag Filter FlexibleMounts (each) Heater Cassette Cassette Connections Size Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref 100 68MP033G 10531100T1 10532100 10533100 FLX100 125 68MP033G 10531125T1 10532125 10533125 FLX125 150 68MP033G 10531150T1 10532150 10533150 FLX150 160 68MP033G - 10532160A 10533160 FLX160 200 68MP033G 10531200T1 10532200 10533200 FLX200 250 68MP033G 10531250T1 10532250 10533250 FLX250 315 68MP033G 10531315T1 10532315 10533315 FLX315 400 68MP033G 10531400T3 10532400 10533400 FLX400 500 68MP033G 10531500T3 10532500A 10533500 FLX500

317 Accessories Backdraught Shutter Stock Ref Fast Clamp Stock Ref Duct Attenuator 300mm 600mm 900mm 1200mm Size Stock Ref Stock Ref Stock Ref Stock Ref 100 10542100 10540100 10534100 10535100 10536100 - 125 10542125 10540125 10534125 10535125 10536125 - 150 10542150 10540150 10534150 10535150 10536150 - 160 - 10540160 - 10535160 - - 200 10542200 10540200 - 10535200 10536200 10537200 250 10542250 10540250 - 10535250 10536250 10537250 315 10542315 10540315 - 10535315 10536315 10537315 400 10542400 10540400 - 10535400 10536400 10537400 500 - - - - 10536500 -

318 Eco Mixed Flow (eMF) •High efficiency Mixed Flow Fan with guide vanes •Available in sizes 355 to 710mm dia. •IP54 Fan rating (duct mounted) •Operating temperatures up to 80°C (see technical specification) •Maintenance free, long life bearings •All units suitable for speed control •Quality Assurance to BS EN ISO 9001:1994 Energy Saver The ‘eMF’ high efficiency in-line mixed flow duct fans are designed around a high efficiency, high pressure development mixed flow impellor, offering a very compact design with high performance and low sound levels. The in-line fan is constructed from steel and incorporates an aerodynamically designed airflow guide vane to ensure maximum performance from the unit.All models offer minimum space requirements for installation and are designed for simple installation into duct ventilation systems via the included mounting foot. All units are suitable for vertical or horizontal mounting. The eMF range is available in 15 models, covering sizes 355, 400, 450, 500, 560, 630 & 710mm diameter. The range shall provide a performance from 0.06m 3 /s to 5.63m 3 /s with a maximum pressuredevelopment of up to 1200 Pa. Impellers The impellers are aerodynamically designed high efficiency mixed flow type, manufactured from steel or polyamide. The motor and impeller is factory matched, statically and dynamically balanced to ISO 1940, Grade G 2.5. Motors All sizes are protected to IP54 in accordance with BS EN 60529:1992. With motors suitable for operating temperatures up to 80°C (see technical data). The range incorporates maintenance free motors, fitted with sealed for life ball bearings, ideally suited for speed control. Single phase 230V units by auto transformercontrol, 3 phase 230V or 400V by frequency inverters. Motor protection by means of a thermal contact switch incorporated within the windings is provided to prevent motor damage due to overloading/overheating. Terminal Box All single phase units are supplied with an IP44 terminal box as standard. All three phase units are supplied with a 2m long flying lead. Performance The fan performance is in accordance with tests to BS848 Part 1 1980, with the fan sound levels measured in a reverberant chamber in accordance with BS848 Part 2 1985. Quality Assurance Design and manufacture is in accordance with the standard for quality management systems BS EN ISO 9001:1994. Accessories A full range of accessories are available with the eMF in-line mixed flow duct fans such as:•Fast Clamps •Auto Transformer Speed Controllers •Frequency Inverters •D.O.L. Starters and Overloads

319 Fan Dimensions (mm) Stock Ref AØ B Weight kg EMF35514 355 396 13.5 EMF35512 354 396 17.3 EMF40014 403 417 12.8 EMF45014 453 467 18.4 EMF50014 504 515 23.2 EMF56014 564 582 38.0 EMF63014 634 655 43.1 EMF35532 354 396 17.5 EMF40034 403 417 14.8 EMF45034 453 467 18.9 EMF50034 504 515 23.6 EMF40032 403 417 20.3 EMF56034 564 582 28.0 EMF63034 634 654 39.3 EMF71034 714 732 49.0

320 00.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 1000 900 800 700 600 500 400 300 200 100 0 1 2 1 1 1 3 1 4 1 5 1 6 1 7 AIR VOLUME m 3 /s STATIC PRESSURE Pa Performance Curve Performance Guide Stock Max Curve m 3 /s at Pa Max S.C. F.L.C. Ref rpm Temp °C Ref 0 100 200 300 400 500 600 700 800 900 Voltage Watts Amps Amps EMF35514 1460 45 1 1 0.71 0.58 0.09 230V/1/50 150 3.0 1.2 EMF35512 2850 80 1 2 1.39 1.32 1.24 1.16 1.05 0.92 0.35 0.20 0.10 0.01 230V/1/50 950 13.5 5.4 EMF40014 1460 80 1 3 0.95 0.82 0.25 0.06 230V/1/50 210 3.8 1.5 EMF45014 1450 80 1 4 1.45 1.31 1.12 0.28 0.06 230V/1/50 450 7.8 3.1 EMF50014 1380 80 1 5 1.87 1.71 1.50 1.25 0.18 230V/1/50 1380 9.3 3.7 EMF56014 1430 80 1 6 2.67 2.51 2.31 1.97 0.78 0.42 0.12 230V/1/50 1110 19.0 7.6 EMF63014 1410 50 7 7 3.89 3.69 3.43 3.18 2.90 2.49 0.54 0.19 230V/1/50 2140 28.5 11.4 Stock Ref 125 250 500 1k 2k 4k 8k dBA @3m EMF35512 INLET 49 72 74 79 78 77 71 40 OUTLET 55 74 80 83 81 77 69 40 BREAKOUT 49 56 60 61 59 58 49 40 EMF35514 INLET 51 57 61 62 63 63 48 26 OUTLET 56 60 66 67 64 60 47 26 BREAKOUT 42 41 43 46 43 46 29 26 EMF40014 INLET 57 60 70 68 69 64 53 35 OUTLET 65 63 73 73 69 65 54 35 BREAKOUT 50 46 59 59 53 52 41 35 EMF45014 INLET 64 66 69 71 74 69 57 42 OUTLET 71 69 77 76 74 70 59 42 BREAKOUT 57 69 67 65 61 57 43 42 EMF50014 INLET 69 69 72 73 73 69 57 41 OUTLET 74 75 78 77 74 70 59 41 BREAKOUT 54 66 65 64 61 59 42 41 EMF56014 INLET 72 77 79 79 78 74 63 49 OUTLET 76 82 85 81 79 76 65 49 BREAKOUT 70 77 75 69 68 63 52 49 EMF63014 INLET 74 78 82 82 80 78 66 50 OUTLET 74 82 86 84 81 78 67 50 BREAKOUT 70 74 76 72 70 65 53 50 Sound Data EMF355 - EMF630 - 1 Phase - 2 & 4 Pole

321 Stock Max Curve m 3 /s at Pa Max S.C. F.L.C. Ref rpm Temp °C Ref 0 200 400 600 800 1000 1200 Voltage Watts Amps Amps EMF35532 2910 60 1 1 1.38 1.27 1.10 0.88 0.15 230V/3/50 910 8.0 3.2 EMF40032 2930 80 1 2 1.92 1.85 1.66 1.49 0.51 0.32 0.11 400V/3/50 1540 8.0 3.2 EMF40034 2200 80 1 3 1.43 1.26 0.88 0.19 230V/3/75 650 6.8 2.7 EMF45034 2150 80 1 4 2.04 1.84 1.60 0.42 230V/3/70 1200 11.0 4.4 EMF50034 2060 70 1 5 2.75 2.53 2.27 1.96 0.34 230V/3/70 1920 17.8 7.1 00.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 1 1 1 2 1 3 1 4 1 5 AIR VOLUME m 3 /s STATIC PRESSURE Pa Performance Curve Performance Guide Stock Ref 125 250 500 1K 2K 4K 8K dBA @3m EMF35532 INLET 52 75 77 79 78 77 74 43 OUTLET 56 76 85 85 82 78 71 43 BREAKOUT 52 60 66 64 60 61 53 43 EMF40032 INLET 73 88 84 84 85 82 80 55 OUTLET 76 89 93 91 87 84 80 55 BREAKOUT 72 88 81 75 71 69 62 55 EMF40034 INLET 68 82 77 77 77 74 66 43 OUTLET 69 85 86 84 79 76 68 43 BREAKOUT 59 59 68 66 62 60 51 43 EMF45034 INLET 72 84 81 79 78 77 69 46 OUTLET 74 87 88 84 81 79 71 46 BREAKOUT 65 69 72 68 63 62 52 46 EMF50034 INLET 61 81 82 83 81 79 72 53 OUTLET 71 81 89 89 86 82 74 53 BREAKOUT 77 77 79 75 70 68 61 53 Sound Data EMF355 - EMF500- 3 Phase - 2 & 4 Pole

322 Stock Max Curve m 3 /s at Pa Max S.C. F.L.C. Ref rpm Temp °C Ref 0 200 400 600 800 Voltage Watts Amps Amps EMF56034 1570 80 1 1 2.90 2.57 1.73 0.37 400V/3/50 1360 7.0 2.8 EMF63034 1590 70 1 2 4.43 4.00 3.56 2.90 0.47 400V/3/50 2620 13.5 5.4 EMF71034 1440 55 1 3 5.63 5.13 4.66 4.05 0.78 400V/3/50 3610 19.3 7.7 Stock Ref 125 250 500 1K 2K 4K 8K dBA @3m EMF56034 INLET 72 74 78 80 78 75 63 48 OUTLET 74 84 83 82 80 76 65 48 BREAKOUT 59 67 74 71 68 63 51 48 EMF63034 INLET 76 77 85 83 81 80 68 51 OUTLET 76 83 88 85 83 80 69 51 BREAKOUT 67 69 77 73 71 66 55 51 EMF71034 INLET 74 84 85 87 83 80 69 54 OUTLET 75 87 90 89 86 81 71 54 BREAKOUT 68 77 78 78 74 66 58 54 00.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 1000 900 800 700 600 500 400 300 200 100 0 1 1 1 2 3 AIR VOLUME m 3 /s STATIC PRESSURE Pa Performance Curve Performance Guide Sound Data EMF560 - EMF710 - 3 Phase - 2 & 4 Pole

323 Accessories eDemand Fan Auto Transformer Frequency Inverter Fast Clamp Stock Ref Voltage/Hz FLC Stock Ref Stock Ref Stock Ref EMF35512 230/1/50 5.4 10314107 - VM355 EMF35514 230/1/50 1.2 10314103 - VM355 EMF40014 230/1/50 1.5 10314103 - VM400 EMF45014 230/1/50 3.1 10314105 - VM450 EMF50014 230/1/50 3.7 10314105 - VM500 EMF56014 230/1/50 7.6 10314113 - VM560 EMF63014 230/1/50 11.4 10314113 - VM630 EMF35532 230/3/50 3.2 - 444177 VM355 EMF40032 400/3/50 3.2 - 444173 VM400 EMF40034 230/3/75 2.7 - 444177 VM400 EMF45034 230/3/70 4.4 - 444177 VM450 EMF50034 230/3/70 7.1 - - VM500 EMF56034 400/3/50 2.8 - 444173 VM560 EMF63034 400/3/50 5.4 - 444174 VM630 EMF71034 400/3/50 7.7 - 444175 VM710 Item available to special order and must be operated with a single phase in three phase out inverter. Please enquire.

324 Powerflow In-Line Duct Fans (ACP) •Tough plastic in-line range in seven models •50-80mm long ribbed spigots •Flame retardant casing •All models speed controllable •Fitted with Standard Thermal Overload Protection (S.T.O.P.) •Manufacture controlled to BS EN ISO 9001 •Performance tested to BS 848 Part1 & 2 •2 Year Guarantee Ducted Ventilation Powerflow models provide a compact yet versatile range designed with the installer in mind, combining the acoustic benefits of a tough plastic casing with the pressure characteristics of a centrifugal fan. A range of seven models from 100 to 315mm dia. duct sizes. The 315mm dia. model has been specifically developed for use with rigid ductwork. Air volumes from 0.059m 3 /s to 0.42m 3 /s in free air andcapable of pressure development up to 550 Pa.Powerflow has 50-80mm long inlet and discharge spigots allowing easy installation and fixing. The adjustable mounting foot allows the terminal box to be rotated to any angle and allows plenty of space and adjustment for screw fixing. The robust fire-retardant polymeric casing combined with internal guide vanes ensures optimum airflow management through the unit. Electrical Motors are 220-240V single phase 50Hz. Capacitor start and run. The terminal box is integral with the case moulding. All motors are fitted with Standard Thermal Overload Protection (S.T.O.P.). Motor/Impellers All models are fitted with an external rotor motor and backward curved impeller assembly for long life and reliability. All sizes are IP44 according to BS EN 60529. Ball bearings are greased for life and designed to run at any angle. Insulation is Class ‘B’ (from -30˚C to +40˚C). Manufacture is controlled to BS EN ISO 9001. Accessories A full range of accessories are available with the Powerflow in-line centrifugal duct fans such as:•Electronic Speed Controllers •Auto Transformer Speed Controllers •D.O.L. Starters •Pre & Secondary Filter Cassettes •Electric Heater Batteries •In-Line Attenuators •Backdraught Shutters •Fast Clamps

325 AIR FLOW CEILING Pre-filter 85% arrestance.Removes dust etc, fromfresh supply air. Robust polymeric casingminimises noise breakoutlevels into the room area. Flexible ducting lightweightand easy to install. Conforms toClass I of BS 476 Part 7. Duct attenuator can reduceNC/NR levels. Anti-vibration mount Typical Installation Fan Dimensions (mm) Dia Øa b c d e Øf g h Weight kg 100 100 146 287 52 52 254 110 270 2.2 125 125 146 287 60 60 254 110 270 2.2 150 149 175 287 52 52 301 110 270 3.1 160 160 175 287 52 52 301 110 270 3.1 200 200 193 290 47 47 344 92 130 4.3 250 250 218 312 65 65 367 92 130 4.6 315 315 250 366 76 76 405 92 130 5.9 Sizes 100, 125,150 & 160 have a flat mounting foot

326 Performance Guide 4 7l/s at Pa Dia. Motor Phase Stock Ref r.p.m IP Rating Curve Ref. 0 100 200 300 400 Motor kW S.C. Amps F.L.C Amps dBA @ 3m 100 1 ACP10012 2740 IP44 1 60 50 30 10 0.08 0.85 0.34 35 125 1 ACP12512 2410 IP44 2 80 60 40 10 0.08 0.85 0.34 35 150 1 ACP15012 2520 IP44 3 140 110 70 40 0.1 1.1 0.43 45 150 1 ACP16012 2520 IP44 4 140 110 70 40 0.1 1.1 0.43 45 200 1 ACP20012 2620 IP44 5 230 200 160 120 0.15 1.52 0.68 47 250 1 ACP25012 2720 IP44 6 290 260 220 180 120 0.19 1.6 0.77 48 315 1 ACP31512 2720 IP44 7 340 290 220 160 90 0.18 1.57 0.75 51 Sound Data Dia. Motor Phase Stock Ref. Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 100 1 ACP10012 Inlet 81 84 75 68 61 52 46 40 51 100 1 ACP10012 Outlet 82 84 77 68 61 52 49 43 52 100 1 ACP10012 Breakout 52 48 57 53 53 48 40 38 36 125 1 ACP12512 Inlet 80 79 76 70 61 57 51 45 51 125 1 ACP12512 Outlet 82 80 76 71 61 54 51 43 52 125 1 ACP12512 Breakout 52 48 57 53 53 48 40 38 36 150 1 ACP15012 Inlet 79 84 84 76 69 65 61 52 58 150 1 ACP15012 Outlet 78 84 83 74 69 65 60 50 57 150 1 ACP15012 Breakout 59 62 66 62 62 58 51 43 45 150 1 ACP16012 Inlet 81 81 79 76 66 61 58 49 55 150 1 ACP16012 Outlet 80 82 81 73 67 62 57 49 55 150 1 ACP16012 Breakout 59 62 66 62 62 58 51 43 45 200 1 ACP20012 Inlet 80 79 74 76 67 65 66 60 55 200 1 ACP20012 Outlet 79 79 74 71 69 69 65 59 55 200 1 ACP20012 Breakout 54 70 67 66 62 59 53 43 47 250 1 ACP25012 Inlet 84 80 74 74 69 69 67 63 56 250 1 ACP25012 Outlet 75 79 73 72 72 73 68 64 58 250 1 ACP25012 Breakout 60 71 70 66 65 62 55 44 49 315 1 ACP31512 Inlet 84 80 74 74 69 69 67 63 56 315 1 ACP31512 Outlet 75 79 73 72 72 73 68 64 58 315 1 ACP31512 Breakout 72 71 73 71 66 63 55 45 52

327 ElectronicAuto D.O.L. Starter eDemand Controller †Duct Air Filter Bag Filter Controller Transformer & Coil Voltage Control 1/3 Phase Inverter 3 Phase Inverter Heater Cassette Cassette Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref ACP10012 W10303102M 10314103 444744 + 444697 444164 - - 10531100T1 10532100 10533100 ACP12512 W10303102M 10314103 444744 + 444697 444164 - - 10531125T1 10532125 10533125 ACP15012 W10303102M 10314103 444744 + 444698 444164 - - 10531150T1 10532150 10533150 ACP16012 W10303102M 10314103 444744 + 444698 444164 - - - - - ACP20012 W10303102M 10314103 444744 + 444699 444164 - - 10531200T1 10532200 10533200 ACP25012 W10303102M 10314103 444744 + 444699 444164 - - 10531250T1 10532250 10533250 ACP31512 W10303102M 10314103 444744 + 444699 444164 - - 10531315T1 10532315 10533315 Duct Attenuator Heat 300mm 600mm 900mm 1200mm Exchange Unit Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref ACP10012 10534100 10535100 10536100 - - ACP12512 10534125 10535125 10536125 - - ACP15012 10534150 10535150 10536150 - - ACP16012 - - - - - ACP20012 - 10535200 10536200 10537200 10538290 ACP25012 - 10535250 10536250 10537250 10538290 ACP31512 - 10535315 10536315 10537315 10538290 Accessories For full range of speed controller options, see Accessories & Controllers section

328 EuroSeries (SDX) •Available in sizes 100 to 315 •200 and 250 sizes also available as high performance •Motor Insulation Class B, protected to IP44 •Operating temperatures from -25°C up to +60°C •All units suitable for speed control •Quality Assurance to BS EN ISO 9001:1994 •Performance tested to BS848 Part 1 1980 •2 Year Warranty The SDX Euroflow in-line centrifugal duct fans are designed around an efficient backward curved centrifugal impeller and external rotor motor to ensure a compact design, high performance and low sound levels. The in-line fan casing is constructed from pressed steel and incorporates an aerodynamically designed airflow guide vane, ensuring maximum performance from the unit whilst maintaining minimum noise levels. All models are supplied with a simple mounting foot for ease of installation. The SDX range is available in eight model sizes: 100, 125, 150, 200, 250 & 315mm diameter as standard performance and sizes 200 and 250 also available as a high performance in-line centrifugal duct fan. The range provides a performance up to 0.372m³/s with a maximum pressure development of 500 Pa. The SDX range is suitable for the extract of clean air only. It is not suitable for extracting or transporting grinding dust, soot, explosive or other aggressive gases etc. Impellers The impellers are aerodynamically designed centrifugal backward curved type, manufactured by injection moulding of a polypropylene resin. The motor and impeller is factory matched, statically and dynamically balanced in two planes to ISO 1940, Grade G 6.3. Motors All units are fitted with motors protected to IP44, insulation Class B and are suitable for temperatures ranging from -25°C to +60°C with humidity levels of up to 95% RH ensuring reliable operation. All sizes are for a 220V/1/50Hz electrical supply and incorporate a manual reset thermal protection device. Terminal Box An IP54 terminal box fitted to the casing with multiple cable entry positions. Performance The fan performance is in accordance with tests to BS848 Part 1 1980, with the fan sound levels measured in a reverberant chamber in accordance with BS848 Part 2 1985. Quality Assurance Design and manufacture is in accordance with the standard for quality management systems BS EN ISO 9001:1994. Accessories A full range of accessories are available with the Euroflow in-line centrifugal duct fans such as: •Electronic Speed Controllers •Auto Transformer Speed Controllers •D.O.L. Starter and Overload •Pre & Secondary Filter Cassettes •Electric Heater Batteries •In-Line Attenuators •Backdraught Shutters •Fast Clamps •Flexible Ducting •Wall Terminals •Roof Terminals

329 Dimensions (mm) ØA C B ØD E Unit Size ØA B C ØD E kg SDX100 100 189 152 244 287 3 SDX125 125 182 143 243 286 3 SDX150 150 217 166 344 387 3 SDX200 200 219 167 344 387 4 SDX200H 200 231 179 344 387 4.7 SDX250 250 223 167 344 387 4 SDX250H 250 230 167 344 387 4.7 SDX315 315 243 175 402 444 5.6

330 Performance Curves Performance Guidem 3 /s @ Pa Dia. Motor Phase Stock Ref r.p.m IP Rating Curve Ref. 0 100 200 300 400 500 600 Motor kW F.L.C Amps dBA @ 3m 100 1 SDX100C 2800 IP44 1 0.11 0.07 0.05 0.07 0.31 26 125 1 SDX125C 2800 IP44 2 0.12 0.08 0.04 0.08 0.31 24 150 1 SDX150C 2800 IP44 3 0.22 0.17 0.13 0.08 0.1 0.44 35 200 1 SDX200C 2600 IP44 4 0.23 0.19 0.15 0.09 0.11 0.45 34 200 1 SDX200HC 2660 IP44 5 0.28 0.24 0.2 0.16 0.09 0.14 0.56 38 250 1 SDX250C 2600 IP44 6 0.23 0.18 0.14 0.09 0.11 0.45 31 250 1 SDX250HC 2460 IP44 7 0.27 0.23 0.19 0.15 0.09 0.02 0.13 0.56 34 315 1 SDX315C 2567 IP44 8 0.35 0.32 0.28 0.23 0.18 0.12 0.05 0.22 0.96 36 Sound Power Level Spectra dB (ref 10 -12Watts) Dia. Motor Phase Stock Ref Spectrum 125 250 500 1k 2k 4k 8k dBA @ 3m 100 1 SDX100C Inlet 53 58 60 66 65 58 47 49 100 1 SDX100C Outlet 54 60 61 67 66 58 48 50 100 1 SDX100C Breakout 34 58 44 55 54 47 37 39 125 1 SDX125C Inlet 50 54 63 65 64 56 47 48 125 1 SDX125C Outlet 49 53 61 64 63 55 45 47 125 1 SDX125C Breakout 28 29 45 53 52 44 35 36 150 1 SDX150C Inlet 51 66 67 71 62 61 53 52 150 1 SDX150C Outlet 52 67 68 72 64 63 50 54 150 1 SDX150C Breakout 30 49 51 60 52 50 36 41 200 1 SDX200C Inlet 46 53 62 66 63 64 54 50 200 1 SDX200C Outlet 45 54 61 68 64 65 53 51 200 1 SDX200C Breakout 22 24 41 49 53 43 40 35 200 1 SDX200HC Inlet 53 60 66 69 66 65 63 53 200 1 SDX200HC Outlet 54 62 65 70 67 67 63 54 200 1 SDX200HC Breakout 25 35 46 53 55 47 45 38 250 1 SDX250C Inlet 41 52 61 66 66 64 56 51 250 1 SDX250C Outlet 43 53 60 68 67 65 57 52 250 1 SDX250C Breakout 24 30 38 48 47 45 40 32 250 1 SDX250HC Inlet 54 62 67 69 67 67 65 54 250 1 SDX250HC Outlet 55 63 66 70 68 67 65 54 250 1 SDX250HC Breakout 33 38 47 50 48 47 46 34 315 1 SDX315C Inlet 50 59 67 68 66 65 64 52 315 1 SDX315C Outlet 51 60 66 69 67 66 65 53 315 1 SDX315C Breakout 33 38 45 48 47 45 43 32247

331 Fan Wall Terminal Wall Terminal Electric Heaters Panel Filters Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref 100 SA100/280 SA100/80 10531100T1 QPF100A 125 SA125/280 SA125/80 10531125T1 QPF125A 150 SA150/280 SA150/80 10531150T1 QPF150A 200 SA200/280 SA200/80 10531200T1 QPF200A 250 SA250/280 SA250/80 10531250T1 QPF250A 315 SA315/280 SA315/80 10531315T1 QPF315A Models & Accessories Fan Stock Ref Speed Controller Starter (requires Overload) Stock Ref Overload Stock Ref Stock Ref Stock Ref SDX100 SP5001 SPM5020 444744 444696 SDX125 SP5001 SPM5020 444744 444696 SDX150 SP5001 SPM5020 444744 444697 SDX200 SP5001 SPM5020 444744 444698 SDX200H SP5001 SPM5020 444744 444699 SDX250 SP5001 SPM5020 444744 444698 SDX250H SP5001 SPM5020 444744 444699 SDX315 SP5001 SPM5020 444744 444699 In-Line Attenuators 300mm 600mm 900mm 1200mm Dia Stock Ref Stock Ref Stock Ref Stock Ref 100 83010030 83010060 83010090 - 125 83012030 83012060 83012090 - 150 83015030 83015060 83015090 - 200 - 83020060 83020090 83020120 250 - 83025060 83025090 83025120 315 - 83031060 83031090 83031120 Fan Bag Filters Roof TerminalLouvre Shutter Stock Ref Stock Ref Stock Ref Stock Ref 100 QPFB100A WRC100 LS250 125 QPFB125A WB160 LS250 150 QPFB150A WB160 LS250 200 QPFB200A WB200 LS250 250 QPFB250A RCZ300 LS250 315 QPFB315A RCZ300 LS315

332 Slimpak (SLP) •Ultra slim and compact •Acoustically treated ‘O’ class rated •‘Eco Flow’ computer modelled design •Latest external rotor motor •Fully speed controllable •Matching ancillaries The Slimpak in-line acoustic fans shall be as supplied from Vent-Axia. Manufactured from prime quality galvanised sheet steel, ensuring a robust in-line fan for those tough site conditions. Slimpak fans are internally treated with an ‘O’ class rated acoustic foam, which offers the benefits of excellent low level duct bound and breakout sound levels, in addition to self extinguishing properties, zero burn role, resistant to ignition and no toxic fumes. Slimpak fans are suitable for circular ducting ranging in sizes 100, 125, 150, 200, 250 and 315mm with air volumes from 0.075m³/s to 0.380m³/s and pressure development of up to 550Pa. The casing shall be specially designed to allow the unit to be mounted quickly and easily. All manufacturing progresses of the Slimpak fan units are computer designed and controlled to BS EN ISO 9001 Standards. Impellers The backward curved centrifugal impellers are be aerodynamically designed, utilising computer technology combining the impeller with the external rotor motor. The motor and impeller is factory matched, statically and dynamically balanced on precision machines, to DIN ISO1940 Grade 6.3, to give quiet, vibration free running. The aerodynamic blades and motor housing are manufactured from prime quality galvanised sheet steel. Motors All sizes from 100 to 315 are protected to IP44 in accordance with BS EN 60529:1992. With motor insulation Class B, suitable for operating temperatures from -15°C and atmospheres up to 95% RH. The range incorporates maintenance free external rotor motors, fitted with sealed for life ball bearings. All sizes are suitable for speed control by electronic or voltage reduction. Vent-Axia would recommend that a voltage reduction Auto Transformerspeed controller is used with all Slimpak units to ensure minimum noise levels during speed control and to eliminate any possibility of harmonic noise levels which occur when using electronic speed controllers at lower levels. Terminal Box An IP54 terminal box is supplied with all models with 20mm cable gland entry, ensuring suitability for external use. Performance The fan performance is in accordance with tests to BS848 Part 1 1980, with the fan sound levels measured in a reverberant chamber in accordance with BS848 Part 2 1985. Quality Assurance Design and manufacture are in accordance with the standard for quality management systems BS EN ISO 9001:1994. Accessories A full range of accessories are available with the Slimpak range of fans such as: • Auto Transformer Speed Controllers• Electronic Speed Controllers• D.O.L. Starters• Pre & Secondary Filter Cassettes• Electric Heater Batteries• Backdraught Shutters• In-Line Attenuators• Wall & Roof Terminals• Fast Clamps

333 A 15 12MM X 6MM FOAM GASKE T 6 HOLES Ø 5.5MMC CTS B C CTS Elevation Plan Stock Ref A B C SLP100 306 80 138 SLP125 306 80 138 SLP150 306 80 138 SLP200 360 130 165 SLP250 360 130 165 SLP315 400 180 184.5 Mounting Bracket (mm) Plan A E B C Elevation Dimensions (mm) Stock Ref A B C DØ E Weight kg SLP100 360 306 160 100 178 8 SLP125 360 306 160 125 165 8 SLP150 360 306 180 150 140 9 SLP200 415 360 285 200 140 13 SLP250 415 360 285 250 90 15 SLP315 450 400 350 315 65 17

334 Curve Duty m 3 /s @ Pa AmpsStock Ref rpm Phase Ref 0 25 50 100 150 200 250 300 350 400 450 500 550 kW FLC SC SLP100 2450 1 1 0.075 0.071 0.068 0.059 0.051 0.041 0.029 0.016 - - - - - 0.058 0.26 1.04 SLP125 2450 1 2 0.094 0.090 0.086 0.076 0.065 0.053 0.040 0.025 - - - - - 0.058 0.26 1.04 SLP150 2450 1 3 0.121 0.116 0.112 0.098 0.085 0.070 0.054 0.038 0.016 - - - - 0.058 0.26 1.04 SLP200 2700 1 4 0.200 0.193 0.188 0.175 0.156 0.138 0.118 0.098 0.073 0.12 0.48 1.92 SLP250 2400 1 5 0.289 0.280 0.271 0.251 0.227 0.201 0.175 0.146 0.117 0.088 0.053 0.13 0.65 3.0 SLP315 2550 1 6 0.380 0.342 0.370 0.350 0.328 0.309 0.290 0.271 0.248 0.220 0.185 0.141 0.079 0.23 1.02 5.0 FLC = Full Load Current SC = Starting Current Performance Guide Performance Curve Stock Ref 63Hz 125 250 500 1K 2K 4K 8K dB(A) @ 3.0m SLP100 inlet 60 63 56 62 51 48 41 40 40 Outlet 61 65 57 58 56 54 50 43 41 Breakout 51 52 53 51 42 38 34 30 30 SLP125 inlet 55 59 58 64 53 49 42 39 42 Outlet 59 61 59 61 59 58 54 45 44 Breakout 52 54 54 52 43 38 34 30 31 SLP150 inlet 52 58 57 64 55 52 47 42 42 Outlet 58 60 60 63 60 59 55 47 45 Breakout 52 53 53 52 43 38 34 30 31 SLP200 inlet 65 68 72 64 56 51 52 47 46 Outlet 60 66 68 71 66 65 65 58 52 Breakout 58 65 65 59 48 43 38 35 39 SLP250 inlet 74 76 75 68 58 57 55 48 50 Outlet 62 72 74 73 72 69 68 59 56 Breakout 61 70 68 63 54 47 43 32 43 SLP315 inlet 71 75 74 70 70 66 63 58 54 Outlet 62 70 76 78 72 71 70 63 59 Breakout 61 69 70 64 58 52 46 37 45 Sound Power Level Spectra dB (re 10 –12Watts)

335 Speed Controller Electronic Auto Transfor. Starter OverloadElectric Heaters Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref SLP100 SP5001 SPM5020 444744 444699 10531100T1 SLP125 SP5001 SPM5020 444744 444699 10531125T1 SLP150 SP5001 SPM5020 444744 444699 10531150T1 SLP200 SP5001 SPM5020 444744 444699 10531200T1 SLP250 SP5001 SPM5020 444744 444700 10531250T1 SLP315 SP5001 SPM5020 444744 444702 10531315T1 Attenuators Inlet Discharge Wall Terminal Stock Ref Stock Ref Stock Ref Stock Ref SLP100 SLSI100/1 SLSD100/1 SA100/280 SLP125 SLSI125/1 SLSD125/1 SA125/280 SLP150 SLSI150/1 SLSD150/1 SA150/280 SLP200 SLSI200/1 SLSD200/1 SA200/280 SLP250 SLSI250/1 SLSD250/1 SA250/280 SLP315 SLSI315/1 SLSD315/1 SA315/280LouvreFlexible Back Draught Roof Terminal Shutter ConnectionsPanel Filters Shutters Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref SLP100 WRC100 LS250 FLX100 SLPF100 BDS100 SLP125 WB160C LS250 FLX125 SLPF125 BDS125 SLP150 WB160C LS315 FLX150 SLPF150 BDS150 SLP200 WB200C LS315 FLX200 SLPF200 BDS200 SLP250 WB200C LS315 FLX250 SLPF250 BDS250 SLP315 RCZ300 LS400 FLX315 SLPF315 BDS315 Models & Accessories

336 Square MixedFlow Fans (MFQ) •Motors protected to IP44 •Motor insulation Class ‘B’ •Standard Thermal Overload Protection •Ductmate flanging •All models speed controllable •Manufacture controlled to BS EN ISO 9001 •Performance tested to ISO 5801 •In duct temperature up to 60°C (dependant on model) The Square Mixed Flow (MFQ) range has been specially designed for systems with high performance and low sound levels in mind. Ideal for commercial and industrial premises, the MFQ range places the emphasis on fast installation, reliable performance and easy access for maintenance. The range offers almost two and a half times the pressure development of conventional axial fans and is an ideal cost effective alternative to two stage axial arrangements. The range is dimensionally compact, saving weight and installation costs. Available in five sizes with a duty range from 0.632m 3 /s to 3.673m 3 /s(2275m 3 /h to 13,222m 3 /h), develops pressures up to 450 Pa. Mixed Flow Impeller and Casing The high efficiency backward curved mixed flow impeller is manufactured in a moulded Polyamide material with 30% Glass Fibre. All other sizes of impeller are constructed in aluminium. All impellers offer non-overloading characteristics and are dynamically balanced for maximum efficiency. The casing is manufactured in sheet steel with Ductmate flanges at both ends. The full range of MFQ fans is manufactured with an Aluzinc casing suitable for both internal and external mounting as standard. Motors A proven external rotor motor design and advanced new design of radial mixed flow impeller assembly has been specially selected for its performance and non-overloading characteristics. The assembly is dynamically balanced to VDI 2060. The motors in this range are rated at IP44 according to BS EN 60529. Ball bearings are greased for life and are designed to run at any angle. Insulation is Class B (from -30˚C to +40˚C).Electrical Single phase 220-240V 50 Hz. Capacitor: start and run. Capacitors are located in the terminal box. Three phase 380-415V 50Hz. All motors are fitted with Standard Thermal Overload Protection (S.T.O.P.).Performance and Sound Tested to ISO 5801. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10-5Pa (20 micro-Pascal). The inlet, outlet and breakout sound power level spectra figures are dB with a reference of 10-12 Watts (1 pico-watt). Quality Assurance Design and manufacture is in accordance with BS EN ISO 9001.

337 AIRFLOW D ‘C’ DUCTMATEFLANGE H G E CRS A OVER FLANGES VARIABLE B SQ I/S F Unit Duct Size A B C D E F G H Weight kg 350 450 x 450 400 450 25 52 406 62 29 345 22 400 500 x 500 450 500 25 52 456 62 29 370 28 450 550 x 550 485 550 35 52 491 62 29 405 42 500 650 x 650 510 650 35 86 516 102 37 455 73 560 700 x 700 530 700 35 52 536 102 37 480 78 Fan Dimensions (mm)

338 Performance Guide 0 100 200 300 400 500 600 1800 1500 1200 900 600 300 0 00.5 1.0 1.5 2.0 2.5350 to 500 dia. - 1 Phase - 4 Pole Air Volume m 3 /s Pressure Pa Absorbed Power kW 4 4 1 3 1 2 1 1Duty m 3 /s @ Pa MotorPhase Stock Ref Poles r.p.m Curve Ref. 0 100 200 300 400 500 Motor kW S.C. Amps F.L.C Amps dBA @ 3m 1 MFQ35014 4 1390 1 m³/s 0.97 0.80 0.56 0.37 5.5 1.85 55 kW 368.63 377.76 356.75 1 MFQ40014 4 1270 2 m³/s 1.29 1.08 0.83 0.44 0.58 6 2.6 57 kW 556.85 572.65 558.43 490.72 1 MFQ45014 4 1380 3 m³/s 1.89 1.67 1.44 1.15 0.70 0.05 1.1 17 5.2 59 kW 1117.53 1135.29 1138.63 1105.84 968.60 720.78 1 MFQ50014 4 1350 4 m³/s 2.38 2.17 1.94 1.66 1.34 0.92 1.65 22 7.4 61 kW 1443.11 1494.90 1518.53 1506.19 1448.25 1327.76 Max temperature 60°C Sound Power Level Spectra dB (re 10 –12Watts) Motor Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 1 MFQ35014 4 Inlet 70 74 76 72 72 70 62 54 56 Outlet 70 74 76 72 72 70 62 54 56 1 MFQ40014 4 Inlet 71 78 79 75 74 69 68 59 58 Outlet 71 78 79 75 74 69 68 59 58 1 MFQ45014 4 Inlet 80 82 79 76 78 73 68 60 61 Outlet 80 2 79 76 78 73 68 60 61 1 MFQ50014 4 Inlet 83 85 81 79 80 76 71 66 63 Outlet 83 85 81 79 80 76 71 66 63

339 Performance Guide 800 700 600 500 400 300 200 100 0 4000 3500 3000 2500 2000 1500 1000 500 0 00.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0400 to 560 dia. - 3 Phase - 4 & 6 Pole Air Volume m 3 /s Pressure Pa Absorbed Power kW 4 4 1 3 1 2 1 1 4 5 MotorPhase Stock Ref Poles r.p.m Curve Ref. 0 100 200 300 400 500 600 700 MotorkW S.C.Amps F.L.CAmps dBA @3m 3 MFQ40034 4 1290 1 m³/s 1.30 1.02 0.72 0.21 0.54 4.2 1.2 57 kW 364.79 370.14 358.53 278.39 3 MFQ45034 4 1370 2 m³/s 1.89 1.62 1.32 0.97 0.48 1 9.5 1.95 59 kW 726.01 726.43 709.22 663.41 558.26 3 MFQ50034 4 1280 3 m³/s 2.49 2.22 1.93 1.57 1.09 0.31 1.45 9.5 2.8 61 kW 868.76 904.37 923.04 911.64 836.23 623.80 3 MFQ56034 4 1330 4 m³/s 3.61 3.36 3.08 2.76 2.39 1.90 1.17 0.29 2.5 22 4.6 68 kW 2366.71 2470.94 2550.37 2590.56 2561.68 2404.60 1989.32 1464.97 3 MFQ56036 6 920 5 m³/s 2.44 1.94 1.36 0.08 0.86 9 2.2 54 kW 567.82 603.77 597.59 387.12 The 3 phase, 4 pole units 400 to 500 are fitted with 2 speed pole change delta/star connection motors as standard (4/6 pole). Max temperature 60°C except MFQ56034.Sound Power Level Spectra dB (re 10 –12Watts) Motor Phase Stock Ref Poles Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 3 MFQ40034 4 Inlet 71 78 79 75 74 69 68 59 58 Outlet 71 78 79 75 74 69 68 59 58 3 MFQ45034 4 Inlet 80 82 79 76 78 73 68 60 61 Outlet 80 82 79 76 78 73 68 60 61 3 MFQ50034 4 Inlet 83 85 81 79 80 76 71 66 63 Outlet 83 85 81 79 80 76 71 66 63 3 MFQ56034 4 Inlet 86 90 87 86 87 81 74 69 69 Outlet 86 90 87 86 87 81 74 69 69 3 MFQ56036 6 Inlet 76 75 73 73 73 65 57 49 55 Outlet 76 75 73 73 73 65 57 49 55

340 FLEXIBLE CONNECTOR FAN UNIT SILENCER AI 150B SQ I/SCDUCTMATE FLANGED H Flexible Connectors and Silencer Silencer Insertion Losses Silencer Resistance Pa Weight Flange Unit A B C D H I kg Ductmate 350 400 450 25 52 345 1200 45 25 400 450 500 25 52 370 1200 48 25 450 485 550 35 52 405 1200 55 35 500 510 650 35 86 455 1500 67 35 560 530 700 35 52 480 1500 70 35 Size 63 125 250 500 1k 2k 4k 8k 350 -3 -5 -14 -27 -36 -36 -29 -24 400 -2 -4 -12 -22 -30 -30 -22 -14 450 -2 -4 -11 -17 -24 -24 -16 -8 500 -3 -6 -15 -23 -31 -31 -21 -11 560 -4 -8 -16 -24 -32 -32 -22 -12 Clamp Details Mount/Feet Details Stock Ref a b c PAVM 1 25 38 27 PAVM 2 35 38 27 PAVM 3 35 38 35 Stock Ref a b c PAVM 1 25 38 60 PAVM 2 35 38 60 PAVM 3 35 38 60 Accessories Dimensions (mm)

341 Accessories Electronic Auto D.O.L.eDemand Controller Standard Fan Controller Transformer Starter Overload Voltage Control 1/3 Phase Inverter 3 Phase Inverter Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref MFQ35014 W10303102M 10314103 444744 444700 444164 - - MFQ40014 W10303102M 10314103 444744 444702 444164 - - MFQ40034 - 10314301 444747 444700 444166 444177 444172 MFQ45014 10303106 10314105 444744 444703 444164 - - MFQ45034 - 10314301 444747 444701 444166 444177 444172 MFQ50014 10303110 10314107 444744 444704 444165 - - MFQ50034 - 10314304 444747 444702 444166 444177 444173 MFQ56034 - 10314307 444747 444703 444166 444177 444173 MFQ56036 - 10314304 444747 444701 444166 444177 444172 For full range of speed controller options, see Accessories & Controllers section Set of Mounting Flexible Matching Acoustic Feet & AV’s Connection Attenuator Jacket Size Stock Ref Stock Ref Stock Ref Stock Ref 350 PAVM1 MFQFC350 MFQSS350 MFQAJ350 400 PAVM1 MFQFC400 MFQSS400 MFQAJ400 450 PAVM2 MFQFC450 MFQSS450 MFQAJ450 500 PAVM3 MFQFC500 MFQSS500 MFQAJ500 560 PAVM3 MFQFC560 MFQSS560 MFQAJ560 NOTE: The 3 phase, 4 pole Units 400 to 500 are fitted with 2 speed pole change delta/star connection motors as standard (4/6 pole).

Twin Fan Vent-Axia twin fan range encompasses direct driven models with air performance up to 3.5m 3 /s withcircular duct from 100 to 500mm and rectangular ducts up to 1200x850mm. As with many Vent-Axia units our Trackmaster twin fan controller range offers the end user flexibility when interfaced with a BMS.In-line with our constant drive to offer energy efficient solutions the night time setback facility reduces the fan output during low occupancy periods.

New & Improved Acoustic Twin Fans (ATQ) 344-349 Power-Line ®(TDF) 350-353 Trakmaster Twin Fan Controller 354-355

344 Vent-Axia ATQ fans feature an acoustic foam of dual density sandwich construction specially selected for maximum sound absorbtion and quiet operation. The housing is designed to be as compact as possible for concealed false ceiling applications. Manufactured in Aluzinc sheet metal, with integral anchorage points to allow the fan to be suspended horizontally via drop rods or anti vibration mounts, ensuring a quick and easy solution to installation. The access panel is easily removed for inspection. Individual gravity operated shutters prevent air from passing through the unit during shut down periods. The full range of acoustic fans are manufactured from Aluzinc and as such are suitable for both internal and external mounting as standard. Ten models are available in sizes 100, 125, 150, 160, 200, 250, 315, 400 and 500, providing air volumes from 0.057m 3 /s to 1.40m 3 /s(205m 3 /h to 5040m 3 /h) at free air. Designed for pressures up to 550Pa. Motors At the heart of the range is a proven external rotor motor and high efficiency backward curved impeller specially selected for its performance. The assembly is dynamically balanced to ISO 1940. Motors are rated to IP44 according to BS EN 60529. Ball bearings are greased for life and allow the fan to run at any angle. Insulation is Class ‘B’ (from -15°C to +50°C). The size 500 utilizes an internal rotor motor with Class B insulation (from -15°C to +40°C). All Acoustic fans are suitable for speed control, an Auto Transformer is recommended to ensure minimum noise levels during speed control so eliminating any possibility of motor harmonic noise. Auto-changeover control is available from the Trackmaster range of controls providing autochangeover control on fan failure and duty sharing options. all controls provide BMS operation via volt free contacts and the option for remote indication. For eDemand controls refer to Accessories & Controllers Section. Terminal Box An IP54 Terminal Box is supplied with all models with 20mm cable gland entry.Performance and Sound Tested to BS 848 Parts 1 & 2. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10 –5 Pa (20 micro-Pascal). The inlet, outlet and breakoutsound power level spectra figures are dB with a reference of 10 –12Watts (1 pico-watt). Electrical The ATQ range is supplied with motors wound to suit a 230V/1ph/50Hz supply capacitor start and run. Quality Assurance Design and manufacture is in accordance with BS EN ISO 9001. New & Improved Acoustic Twin Fans (ATQ) •Improved efficiency available in sizes from 100 to 500mm dia •Acoustically treated housing, Class ‘O’ rated, now with sandwichconstruction for maximum noise absorbtion •Now manufactured in Aluzinc for internal and external use •Motor insulation Class B •Maximum operating temperature 50°C •Standard Thermal Overload Protection •Manufacture controlled to BS EN ISO 9001 •Performance tested to BS 848 Part 1 & 2 •2 Year Guarantee

345 Typical Installation Exhaust Grille Concrete Studding Circular Duct Attenuator AIRFLOW False Ceiling AcousticFlexible FastClamp Fast Clamp Circular Duct Attenuator Dimensions (mm) B A Ø CE DF Duct Diameter mm WeightStock Ref A B ØC D E F Kg ATQ10012D 610 705 100 591 256 622 26 ATQ12512D 610 705 125 591 256 622 26 ATQ15012D 610 705 150 591 256 622 26 ATQ16012D 610 705 160 591 256 622 26 ATQ20012D 801 896 200 703 343 734 39 ATQ25012D 925 1020 250 798 354 829 48 ATQ31512LD 1255 1353 315 1145 536 1176 88 ATQ31514HD 1255 1353 315 1145 536 1176 90 ATQ40014D 1255 1353 400 1145 536 1176 90 ATQ50014D 1492 1590 500 1533 675 1564 175

346 Performance Curve 4 Performance GuideAirflow, m 3 /s @ Pa Dia. Motor Phase Stock Ref r.p.m Curve Ref. 0 50 100 150 200 250 300 Motor kW S.C. Amps F.L.C Amps 100 1 ATQ10012D 2450 1 0.08 0.07 0.06 0.05 0.03 0.02 0.01 0.06 1.04 0.26 125 1 ATQ12512D 2450 2 0.1 0.09 0.07 0.06 0.04 0.03 0.01 0.06 1.04 0.26 150 1 ATQ15012D 2450 3 0.1 0.09 0.08 0.06 0.05 0.04 0.06 1.04 0.26 160 1 ATQ16012D 2450 4 0.1 0.09 0.08 0.06 0.05 0.04 0.06 1.04 0.26 Sound Power Level Spectra dB (re 10 –12Watts) Dia. Stock Ref Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 100 ATQ10012D Inlet 53 59 68 58 50 45 34 33 41 100 ATQ10012D Outlet 54 57 63 59 60 54 49 42 43 100 ATQ10012D Breakout 46 51 58 48 41 38 31 32 31 125 ATQ12512D Inlet 51 65 73 62 51 46 36 36 45 125 ATQ12512D Outlet 52 62 67 64 62 55 52 45 46 125 ATQ12512D Breakout 48 52 59 49 41 40 33 32 32 150 ATQ15012D Inlet 54 60 70 59 52 46 38 36 42 150 ATQ15012D Outlet 56 58 63 58 59 56 49 43 43 150 ATQ15012D Breakout 48 52 58 51 43 38 31 33 32 160 ATQ16012D Inlet 54 60 70 59 52 46 38 36 42 160 ATQ16012D Outlet 56 58 63 58 59 56 49 43 43 160 ATQ16012D Breakout 48 52 58 51 43 38 31 33 32

347 Performance Curve Performance GuideAirflow, m 3 /s @ Pa Dia. MotorPhase Stock Ref r.p.m CurveRef. 0 50 100 150 200 250 300 350 400 450 MotorkW S.C.Amps F.L.CAmps 200 1 ATQ20012D 2700 1 0.2 0.18 0.17 0.14 0.12 0.1 0.08 0.05 0.12 1.92 0.48 250 1 ATQ25012D 2400 2 0.28 0.26 0.24 0.22 0.19 0.17 0.13 0.11 0.08 0.06 0.13 3 0.65 315 1 ATQ31512LD 2550 3 0.38 0.35 0.33 0.31 0.29 0.27 0.25 0.23 0.18 0.14 0.23 5 1.02 315 1 ATQ31514HD 1330 4 0.58 0.54 0.49 0.44 0.37 0.3 0.23 0.13 0.02 0.27 4.72 1.18 400 1 ATQ40014D 1340 5 0.95 0.81 0.73 0.64 0.56 0.49 0.42 0.25 0.47 9.32 2.33 500 1 ATQ50014D 1330 6 1.27 1.2 1.11 0.98 0.88 0.79 0.68 0.57 0.47 0.26 0.73 12.84 3.21 Sound Power Level Spectra dB (re 10 –12Watts) Dia. Stock Ref Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 200 ATQ20012D Inlet 60 65 63 68 58 55 54 46 46 200 ATQ20012D Outlet 60 63 68 72 68 67 62 53 53 200 ATQ20012D Breakout 53 58 57 55 46 41 35 34 34 250 ATQ25012D Inlet 64 74 72 67 57 55 56 53 48 250 ATQ25012D Outlet 64 74 75 69 70 71 65 64 56 250 ATQ25012D Breakout 52 57 68 52 44 40 36 38 39 315 ATQ31512LD Inlet 72 69 79 67 63 62 60 61 52 315 ATQ31512LD Outlet 69 68 74 70 70 71 66 70 56 315 ATQ31512LD Breakout 60 61 67 56 55 51 44 42 41 315 ATQ31514HD Inlet 66 78 68 60 52 49 42 40 45 315 ATQ31514HD Outlet 67 75 77 71 69 62 56 49 53 315 ATQ31514HD Breakout 53 67 61 52 47 41 34 33 36 400 ATQ40014D Inlet 73 82 79 68 62 55 50 49 52 400 ATQ40014D Outlet 72 78 78 75 74 66 58 53 57 400 ATQ40014D Breakout 57 68 61 56 51 45 39 34 38 500 ATQ50014D Inlet 77 85 78 71 64 62 54 52 54 500 ATQ50014D Outlet 74 83 82 78 77 72 64 58 61 500 ATQ50014D Breakout 66 78 71 62 56 49 42 41 46

348 Duct Attenuators Dimensions (mm) Stock kg Length Ref. Øa Øb c d approx300 10534100 100 200 300 50 2.6 300 10534125 125 225 300 50 3.6 300 10534150 150 250 300 50 4 300 10534160 160 250 300 50 4 600 10535100 100 200 600 50 4 600 10535125 125 225 600 50 4.5 600 10535150 150 250 600 50 6 600 10535160 160 250 600 50 6 600 10535200 200 315 600 57.5 7.4 600 10535250 250 355 600 52.5 10.2 600 10535315 315 450 600 67.5 13 600 10535400 400 606 600 103 18.5 900 10536100 100 200 900 50 7 900 10536125 125 225 900 50 8 900 10536150 150 250 900 50 9 900 10536160 160 250 900 50 9 900 10536200 200 315 900 57.5 11 900 10536250 250 355 900 52.5 14.7 900 10536315 315 450 900 67.5 18 900 10336400 400 606 900 103 38 900 10536500 500 711 900 105.5 43 1200 10537200 200 315 1200 57.5 14 1200 10537250 250 355 1200 52.5 18.5 1200 10537315 315 450 1200 67.5 21.5 1200 10537400 400 606 1200 103 50 1200 10537500 500 711 1200 105.5 60 Duct Attenuator Insertion Losses Stock Duct Ref. Length Ø 63 125 250 500 1k 2k 4k 8k 10534100 300 100 3 4 10 18 23 25 25 12 10534125 300 125 3 4 8 17 21 23 21 11 10534150 300 150 3 3 6 14 20 23 21 11 10534160 300 160 3 3 6 14 20 23 21 11 10535100 600 100 5 8 16 33 39 40 36 17 10535125 600 125 4 8 13 30 34 35 31 15 10535150 600 150 4 7 13 23 29 36 31 15 10535160 600 160 4 7 13 23 29 36 31 20 10535200 600 200 4 5 11 21 26 32 20 9 10535250 600 250 3 6 10 19 24 29 19 8 10535315 600 315 3 5 8 16 21 22 16 15 10535400 600 400 3 4 7 14 18 19 14 13 10536100 900 100 10 13 20 39 45 38 35 18 10536125 900 125 9 12 18 37 41 37 32 16 10536150 900 150 8 9 15 30 37 37 33 17 10536160 900 160 8 9 15 30 37 37 33 17 10536200 900 200 7 9 14 27 31 36 25 12 10536250 900 250 5 8 13 24 30 31 22 11 10536315 900 315 4 7 11 20 31 27 17 12 10536400 900 400 3 5 9 19 26 20 13 11 10536500 900 500 3 4 9 15 23 17 12 11 10537200 1200 200 10 12 17 35 40 43 27 13 10537250 1200 250 7 9 15 31 36 38 26 12 10537315 1200 315 6 8 13 23 32 30 18 11 10537400 1200 400 6 8 14 24 30 28 17 9 10537500 1200 500 5 7 13 18 26 23 15 9

349 Accessories eDemand eDemand Anti- RVC Remote Remote Auto Voltage Vibration Visual Setback Auto Changeover Controller Mounts Indicator Controller Transformer Size Stock Ref. Stock Ref. Stock Ref.Stock Ref.Stock Ref.Stock Ref.100 444180 444164 68MP033G 10314220 10314230 10314103 125 444180 444164 68MP033G 10314220 10314230 10314103 150 444180 444164 68MP033G 10314220 10314230 10314103 160 444180 444164 68MP033G 10314220 10314230 10314103 200 444180 444164 68MP033G 10314220 10314230 10314103 250 444180 444164 68MP033G 10314220 10314230 10314103 315 444180 444164 68MP033G 10314220 10314230 10314103 400 444180 444164 68MP033G 10314220 10314230 10314105 500 444180 444164 68MP033G 10314220 10314230 10314105 ITC Man/Auto ITC-DS 12/24hr StandardChangeover Auto Changeover Fan Controller Controller SizeStock Ref.Stock Ref. Stock Ref. 100 ATQ10012D 10314200 10314210 125 ATQ12512D 10314200 10314210 150 ATQ15012D 10314200 10314210 160 ATQ16012D 10314200 10314210 200 ATQ20012D 10314200 10314210 250 ATQ25012D 10314200 10314210 315 ATQ31512LD 10314200 10314210 315 ATQ31514HD 10314200 10314210 400 ATQ40014D 10314200 10314210 500 ATQ50014D 10314200 10314210 Backdraught Fast Duct Attenuator Shutter Clamp 300mm 600mm 900mm 1200mm Size Stock Ref. Stock Ref. Stock Ref. Stock Ref. Stock Ref. Stock Ref. 100 10542100 10540100 10534100 10535100 10536100 - 125 10542125 10540125 10534125 10535125 10536125 - 150 10542150 10540150 10534150 10535150 10536150 - 160 - 10540160 - 10535160 - - 200 10542200 10540200 - 10535200 10536200 10537200 250 10542250 10540250 - 10535250 10536250 10537250 315 10542315 10540315 - 10535315 10536315 10537315 400 10542400 10540400 - 10535400 10536400 10537400 500 - - - - 10536500 - Not suitable for use with eDemand controllers. For compatible changeover panel, see Accessories and Controllers Section Set of 4

350 The TDF range uses twin backward curved radial impellors (Run & Standby) and is designed for induct installations. Casings Robustly constructed from aluzinc sheet steel, fitted with proprietry flanges at each end in accordance with DW142. Impellers Aerodynamically designed backward curved radial impeller constructed in a moulded GRP reinforced Polypropylene to suit the performance requirements. The rotor of the external rotor motor forms the hub of the impeller. Rotors and impellers are factory matched and statically and dynamically balanced on precision machines according to VDI2060 quality class Q6.3. Motors Maintenance free external rotor motors with generously dimensioned sealed for life ball bearings encapsulating a high temperature lubricant. The bearings allow for the fan to be mounted at any angle. Insulation is Class B with the enclosure IP44 according to DIN 40050. The electrical design corresponds to VDE 0530/12.84. The motors are suitable for operation in atmosphere up to 95% RH and ambients up to 40°C. Motors are wound to suit either 240V 50HZ 1PH or 415V 50HZ 3PH electrical supply. All motors are fitted with Hot Spot protection by means of a thermal contact switch incorporated in the motor windings to prevent motor damage due to overloading. As the motors have a special torque-speed characteristic they are ideally suited for speed control by voltage reduction. Performance Performance figures given have been tested using installation Type ‘D’ in accordance with BS848 Part 1 1980 and BS848 Part 2 1985. The aerodynamic performance data being to tolerance Class ‘C’ as recommended by BSI C.A.M.E Scheme, Certification No CM005. Sound Levels Sound Levels are measured in areverberent chamber in accordance with BS848 Part 2. Sound level measurements are taken with the fan operating at 20% of its maxium pressure development. Published dBA figures are sound pressure levels measured at a distance of 3m with spherical sound level propagation. It is included for comparative purposes only and the real sound level experienced will depend on the acoustic characteristics of the area being served. Quality Assurance Design and manufacture is in accordance with Quality Assured to BS EN ISO9001. Power-Line (TDF) •Direct Drive Twin Fan (Run & standby) •Backward Curved Radial Impellors •Performance range up to 3.5m 3 /s •Static Pressure Development up to 500Pa •Speed Controllable •Quality assured to BS EN ISO 9001 •Performance listed to BS 848 Part 1

351 Fan Dimensions (mm) C L N ‘H’ Dia Holes A i/s E cts Flanges ‘G’ Ductmate D D K F cts B i/s B Max Unit Size A B C D E F G H J K L N Weight Kg 320 500 655 900 230 525 680 25 9 50 150 130 220 65 380 550 745 1015 260 585 780 35 11 50 160 130 240 75 420 625 830 1130 295 600 865 35 11 50 230 230 220 103 480 700 925 1250 325 735 960 35 11 65 230 230 300 112 520 775 1055 1385 355 810 1090 35 11 50 230 230 350 145 600 850 1200 1530 400 885 1235 35 11 55 230 230 400 180Note: For motor removal allow D+J minimum clearancePower Line TDF Flexible Connections Dimensions (mm) Unit Code W H Ductmate 320 500 655 25 380 550 745 35 420 625 830 35 480 700 925 35 520 775 1055 35 600 850 1200 35 Power Line TDF Attenuators Unit Code RUTDS W L H Ductmate Weight 320 500 900 655 25 30 380 550 1200 745 35 62 420 625 1200 830 35 70 480 700 1500 925 35 96 520 775 1500 1055 35 110 600 850 1800 1200 35 150

352 Performance CurvePerformance GuideAirflow, m 3 /s @ Pa Unit Size MotorPhase Stock Ref r.p.m Curve Ref. 0 100 200 300 400 500 600 Motor kW S.C. Amps F.L.C Amps dBA @ 3m 320 1 TDF32014 1390 1 0.73 0.58 0.46 0.29 0.37 5.5 1.85 58 380 1 TDF38014 1270 2 0.87 0.76 0.64 0.49 0.28 0.58 6 2.6 59 380 3 TDF38034 1290 3 0.87 0.76 0.64 0.49 0.28 0.54 4.2 1.2 59 420 1 TDF42014 1380 4 1.3 1.08 0.93 0.75 0.57 1.1 17 5.2 61 420 3 TDF42034 1370 5 1.3 1.08 0.93 0.75 0.57 1 9.5 1.95 61 480 1 TDF48014 1350 6 1.93 1.71 1.52 1.33 1.16 0.95 1.65 22 7.4 66 480 3 TDF48034 1280 7 1.93 1.71 1.52 1.33 1.16 0.95 1.45 9.5 2.8 66 520 3 TDF52034 1330 8 2.61 2.34 2.15 1.93 1.73 1.55 2.5 22 4.6 67 520 3 TDF52036 920 9 1.82 1.47 1.13 0.77 0.86 9 2.2 55 600 3 TDF60034 1425 10 3.52 3.35 3.22 3.07 2.89 2.69 2.36 3.7 50 7.1 70 600 3 TDF60036 925 11 2.33 2.02 1.72 1.4 1.02 0.76 1.2 17 2.7 56 Sound Power Level Spectra dB (re 10 –12Watts) Unit Size Stock Ref Spectrum 63 125 250 500 1k 2k 4k 8k dBA @ 3m 320 TDF32014 Inlet 65 84 79 77 73 70 65 58 58 320 TDF32014 Outlet 65 84 79 77 73 70 65 58 58 320 TDF32014 Breakout 65 69 64 62 58 55 50 43 43 380 TDF38014 Inlet 66 84 78 79 75 71 66 59 60 380 TDF38014 Outlet 66 84 78 79 75 71 66 59 60 380 TDF38014 Breakout 66 69 63 64 60 56 51 44 45 380 TDF38034 Inlet 66 84 78 79 75 71 66 59 60 380 TDF38034 Outlet 66 84 78 79 75 71 66 59 60 380 TDF38034 Breakout 66 69 63 64 60 56 51 44 45 420 TDF42014 Inlet 74 91 83 81 76 72 69 65 62 420 TDF42014 Outlet 74 91 83 81 76 72 69 65 62 420 TDF42014 Breakout 74 76 68 66 61 57 54 50 47 420 TDF42034 Inlet 74 91 83 81 76 72 69 65 62 420 TDF42034 Outlet 74 91 83 81 76 72 69 65 62 420 TDF42034 Breakout 74 76 68 66 61 57 54 50 47 480 TDF48014 Inlet 76 95 88 86 81 76 76 71 67 480 TDF48014 Outlet 76 95 88 86 81 76 76 71 67 480 TDF48014 Breakout 76 80 73 71 66 61 61 56 52 480 TDF48034 Inlet 76 95 88 86 81 76 76 71 67 480 TDF48034 Outlet 76 95 88 86 81 76 76 71 67 480 TDF48034 Breakout 76 80 73 71 66 61 61 56 52 520 TDF52034 Inlet 80 96 89 86 83 78 72 66 68 520 TDF52034 Outlet 80 96 89 86 83 78 72 66 68 520 TDF52034 Breakout 80 81 74 71 68 63 57 51 53 520 TDF52036 Inlet 80 81 78 80 71 62 60 52 58 520 TDF52036 Outlet 80 81 78 80 71 62 60 52 58 520 TDF52036 Breakout 80 66 63 65 56 47 45 37 44 600 TDF60034 Inlet 83 99 94 90 87 85 75 70 72 600 TDF60034 Outlet 83 99 94 90 87 85 75 70 72 600 TDF60034 Breakout 83 84 79 75 72 70 60 55 57 600 TDF60036 Inlet 84 86 80 77 73 66 61 56 58 600 TDF60036 Outlet 84 86 80 77 73 66 61 56 58 600 TDF60036 Breakout 84 71 65 62 58 51 46 41 44 For sound breakout through the fan casing the above figures may be reduced by 15dB across the frequency band 125 to 8k 2 3 5 11 7

353 Power-Line Silencers Type TDS UnitAttenuation across Sound Spectrum H 3 Code TDS 63 125 250 500 1K 2K 4K 8K 320 3 8 17 24 32 32 25 20 380 6 12 23 32 45 45 33 28 420 6 10 20 31 43 43 33 27 480 4 9 17 27 36 36 24 13 520 3 7 14 22 27 21 15 10 600 4 8 15 24 30 26 14 8 Accessories Transformer eDemand Controller Size Speed Controller Auto Changeover Voltage Control 1/3 Phase Inverter 3 Phase Inverter W x H Fan Stock Ref. Stock Ref. Stock Ref. Stock Ref. Stock Ref. Stock Ref. 500 x 655 TDF32014 10314103 444180 444164 - - 550 x 745 TDF38014 10314103 444180 444164 - - 550 x 745 TDF38034 10314301 444179 444166 444177 444172 625 x 830 TDF42014 10314105 444180 444164 - - 625 x 830 TDF42034 10314304 444179 444166 444177 444172 700 x 925 TDF48014 10314107 444180 444165 - - 700 x 925 TDF48034 10314304 444179 444166 444177 444173 775 x 1055 TDF52034 10314304 444179 444166 444177 444173 775 x 1055 TDF52036 10314304 444179 444166 444177 444172 850 x 1200 TDF60034 10314307 444179 444167 - 444175 850 x 1200 TDF60036 10314304 444179 444166 444177 444173 ITC Man /Auto ITC-DS 12/24hr RVC Remote RSC Remote Weather Proof Size Ch’over Cont.Auto Ch’over Visual Indicator Setback Cont. Treatment W x H Stock Ref. Stock Ref. Stock Ref. Stock Ref. Stock Ref. 500 x 655 10314200 10314210 10314220 10314230 ECP2 550 x 745 10314200 10314210 10314220 10314230 ECP2 625 x 830 10314200 10314210 10314220 10314230 ECP3 700 x 925 10314200 10314210 10314220 10314230 ECP3 775 x 1055 10314200 10314210 10314220 10314230 ECP3 850 x 1200 10314200 10314210 10314220 10314230 ECP4 Mounting FeetFlexible Matching Acoustic Discharge Roof Size& AVs (Set of 4) Connection AttenuatorJacket Cowl Canopy W x H Stock Ref. Stock Ref. Stock Ref. Stock Ref. Stock Ref. Stock Ref. 500 x 655 PAVM1 TFC320 RUTDS320 TAJ320 - TRC320 550 x 745 PAVM2 TFC380 RUTDS380 TAJ380 TDW380 TRC380 625 x 830 PAVM3 TFC420 RUTDS420 TAJ420 TDW420 TRC420 700 x 925 PAVM3 TFC480 RUTDS480 TAJ480 TDW480 TRC480 775 x 1055 PAVM3 TFC520 RUTDS520 TAJ520 TDW520 TRC520 850 x 1200 PAVM3 TFC600 RUTDS600 TAJ600 TDW600 TRC600 Not suitable for use with eDemand controllers. For compatible changeover panel, see Accessories and Controllers Section.

354 ITC - (Trakmaster twin fan control) Provides automatic changeover on fan failure as well as enabling a manual selection of either fan for duty sharing or test purposes. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals. Stock Ref10314200 ITC-DS - (Trakmaster twin fan control - Duty sharing) Incorporates a timing mechanism which operates alternate fans on 12 or 24 hour intervals, thus ensuring the extended life of the fan bearings. The controller also provides automatic changeover on fan failure along with the facility for manual selection of either fan. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals.Stock Ref10314210 RSC - (Remote setback control) The RSC multi-speed control system offers 2 speed fan versatility eg. Energy Management for night-time setback. Can be used in conjunction with Vent-Axia ITC, ITC-DS controllers using 5 step auto-transformer speed controllers for speed selection. Uses 24V output from ITC controller.Stock Ref.103 14 230 For alternative eDemand twin fan controls see Accessories & Controllers Section RVC - (Remote visual indicator) Wired in conjunction with either an ITC or ITC-DS controller the RVC can be located up to 100m away using low cost ELV wiring. The compact, single gang RVC ELV (Extra Low Voltage) remote visual controller indicates status of Fan 1 and Fan 2 with status/warning lights. Push button allows Fan 1 and Fan 2 with standby (Off) to be selected.Stock Ref10314220 Electrical ITC/ITC-D S Maximum load: 9 amps on single or three phase. Dimensions ITC-DS - 103 14 210OR ITC - 10314200RSC - 103 14 230ARVC - 10314220Note: Suitable for mounting with single gang electrical box. Trakmaster Twin Fan Controller •Range of intelligent Vent-Axia twin fan controllers•Designed to offer total flexibility•Controlled interface with BMS (Building ManagementSystems) saving installation costs •Providing energy management/night setback facility

355 PLEASE NOTE: The ITC Controllers may be used in conjunction with a 5-Step Auto Transformer SPEED CONTROLLER for commissioning purposes to meet the required design criteria. Connection Layout of ITC And ITC-DS Controller For full wiring information, refer to ITC Fitting & Wiring instructions. ThermoSwitchOperates on either a fall or rise in temperature for extraction of excess heat. Range 6°C to 30°C. Stock Ref.563502 7-Day TimeSwitch7-Day timer with analogue display. Override facility. Gives twelve On or Off positions per day.Stock Ref.563515 Ecotronic HumidistatAn electronic On/Off humidistat with concealed humidity adjustment 65-90% RH with removable pullcord override. Changeover relay switch. Stock Ref.563550 HumidiSwitch Actuates mechanical humidistat ventilating units on either a rise or fall in humidity. Concealed adjustment. Range 20% to 80% RH. Stock Ref. 563501 Air Quality SensorAutomatically reacts to tobacco smoke, smells and toilet odours to trigger the system or switch speed. Stock Ref.563506 Visionex PIR DetectorCeiling mounted movement detector. Adjustable overrun timer 5 to 25 minutes.Fits any UK single gang mounting box.Range of detection up to 10 metres.220-240V. Stock Ref.459623 Sensors for use with ITC and ITC-DS controls

SentinelD-Box The Sentinel D-Box from Vent-Axia is the answer to key problems such as ‘Why ventilate a room you’re not using?’ or ‘Why over ventilate a room with only one or two occupants inside?’ Sentinel overcomes many of the issues encountered with a traditional fixed volume ventilation system that is either On or Off irrespective of the number of people in the room, risking room over ventilation, burning valuable money and is a wasteful use of energy. The Sentinel system from Vent-Axia benefits the commercial building by providing: •Lower energy consumption than traditionalsystems •Reduced losses to ventilation under partoccupancy•Longer running life•Reduced operating costs•Savings in lifetime maintenance costs•Ease of installation

Sentinel D-Box Single Fan 362-371 Sentinel D-Box Twin Fan 372-381 Sentinel D-Box Sensors & Controls 382-383

358 Sentinel is a range of ventilation systems for multi-occupancy and intermittently used rooms. Using energy efficient ducted fans with intelligent sensing and control, the system meets the ventilation requirements of both new builds and refurbishment projects.Ideal for applications where rooms are used at different times of the day by a variable number of people, the Sentinel system will monitor occupancy, ventilation rate and air quality, and respond accordingly to maintain the atmosphere within preset limits. Typical Applications A network of hotel bathrooms, flats or apartments, which require ventilation, but are only used in limited periods particularly in the morning and in the evening.School classrooms and lecture theatres which are only occupied during lesson time by a variable number of students, but when used must keep CO 2levels within prescribed limits.Office meeting rooms or open plan areas which are used periodically during the day by a variable number of staff and visitors, but when occupied must meet required airflow rates.Automatic sensing and control runs the system according to the maximum demand requirements of the building zone, whether it be carbon dioxide levels, temperature, humidity or air quality – triggered by people entering or leaving the rooms. Common configurations include Electronic Static Pressure (ESP) controllers for constant pressure systems. System Control The precise control of the Sentinel system, driven by the ventilation requirements of the room means that the system is only running to the level required and only using energy when it is needed. A range of sensors are employed to determine the occupancy of the rooms and manage the system ventilation rates accordingly. This optimises the use of energy whilst meeting the legislation requirements of the building. This compares to a ‘traditional’ fixed volume system, which in general is either ‘ON’ or ‘OFF’ often using energy to ventilate an empty or half occupied room, over ventilating and wasting energy. System Overview The Sentinel System is made up of 3 parts: EC/DC Fan Motor, Sentinel Integral Control Unit, Sensors and Controls. The ventilation demands of the room are detected by the wall, ceiling or duct mounted Sentinel sensors/switches. These communicate with the Sentinel control unit, which in turn drives the fanto the required speed to deliver the airflow. As the ventilation is provided to the room the sensors continuously feedback to the control unit, driving the fan motor to the exact level required in the room at any one time. Accessories For duct accessories refer to Accessories Section. Sentinel D-Box Fans •Ideal for multi-occupancy and intermittently used rooms •System only runs to level required •Avoids over-ventilation •Reduces energy use

359 Typical network of hotel bathrooms/flats/apartments Typical school classroom Typical office plan with conference facilities System Technology Sentinel demand ventilation is a closed loop controlled ventilationsystem. Employing a range of sensors to manage the system, demandis sensed by PIR, temperature, humidity, air quality or carbon dioxidesensors. Depending on the levels in the rooms, Sentinel’s fan speed isramped up or down to control the parameters within the required limits.If the room is unoccupied, the system switches off, saving energy andcost to the business. Available in single or twin fan configurations, withtwin allowing for load sharing or ‘standby’ for extra reliability. EC/DC Energy Saving Fan Motor Technology Sentinel utilises the latest EC/DCmotor technology, which providesenergy saving benefits even overDC motors. This technology is also infinitelyspeed controllable and offersincreased energy savings acrossthe complete speed control rangewhen compared with conventional inverter drive solutions. The resultis higher efficiency, reduced noise, accurate controllability, betterspeed control drawing less power and as a result better overall systemperformance. Sentinel can be used in a hierarchal system where maximum demand,for example temperature and/or CO 2gives priority control of the fanspeed or a constant pressure system with room mounted PIR/grilles orin-line damper control.

360 10 20 30 40 50 60 70 80 90 0 50 100 150 200 250 300 350 400 450 500 Output power P2 (W) Motor Ef ficiency (% ) 1 1 1 2 1 3 1 4 1 1 2 1 3 4 EC/DC Motor 3 Phase - AC 1 Phase - AC Shaded pole motor Source: ebmpapst AC Motor with Triac voltage control AC Motor with Transformer voltage control AC Motor with frequency inverter EC/DC Motor 1 2 1800 1600 1400 1200 1000 Electrical input power [Watts] Air Performance 800 600 400 200 0 5000 7000 9000 11000 13000 15000 17000m 3 /h 1 1 1 1 2 1 3 4 1 2 4 4 1 3 Source: ebmpapst As can be seen from above motor comparisons, the EC/DC motor offers higher efficiencies when compared to AC motors, and also consumes lesspower under speed control, giving both the highest motor efficiency and lowest power consumption across the speed control range . Typical EC/AC Motor Speed Control Comparison Highest Motor Efficiency

361 Hierarchal Control The system is controlled by on-board electronics, with an LCD display showing fan status and allowing for simple commissioning and installation, whether as a local sensor control unit or linked into a building management system. 1. Switched on/off or minimum/maximum level control In an environment such as an office the system is activated and runs between minimum and maximum levels by a choice of sensors. •AQS – Air Quality Sensor •PIR Detector • Thermostat • Humidistat •Time Clock •BMS (remote enable) 2. Hierarchical – maximum demand multi-sensor input Used with a combination of sensors, with a defined level of priorities to simultaneously control a number of atmospheric conditions within a room, such as a meeting room. • CO 2 /temperature – room mounted • CO 2– duct mounted •Manual speed adjuster •Building Management System (0-10V) Constant Pressure Extract Applied in a discreet central extract system, such as hotel bathrooms or apartment blocks, the system grilles and/or duct dampers are controlled by the presence of a person in the room or by achieving required levels of humidity. The central system will respond to the demand depending on the number of active rooms. •PIR/Humidity Extract Grille 125mm •PIR 12 - 70m 3 /h • Humidity: 12m 3 /h @ 30% RH 70m 3 /h @ 75% RH •Motorised Duct Dampers 100mm - 315mm Dia •Built in end stop adjustment for setting minimum and maximumvolume •24V Min/Max or 0-10V proportional control options •Motorised Duct Dampers – Sensor Control options•Each 24V powered extract damper can by controlled by one of thefollowing sensors:- Min-Max (DVDxxx/MM) •AQS - Air Quality Sensor – Room (432953) •PIR Detector – Room (433162) •Thermostat - Room (563502) •Humidistat - Room (432945) Proportional 0-10V (DVDxxx/PC) •Carbon Dioxide Sensor – Room (433259) •Carbon Dioxide Sensor – Duct (433259) •Temperature Sensor - Room (434749) Note Local 24V power supply required to power dampers & sensors (426526)

362 The Sentinel single in-line duct fans are as supplied from Vent-Axia Ltd. Manufactured from Aluzinc, Sentinel fan units are internally treated with an ‘O’ class rated, BS476 part 6 & 7 acoustic foam which offers the benefits of high sound absorption, good thermal insulation properties, in addition to self extinguishing properties and resistance to ignition. Weatherproof external units incorporate an additional controller shroud. The casing includes an inclined inlet and bellmouth entry which directs the incoming air to the impeller with minimal turbulence. The result is better air management through the unit, less noise, higher efficiency and an increased performance.The housing is designed to be as compact as possible for concealed false ceiling applications and Sentinel casings are specially designed to allow the unit to be mounted via its unique mounting bracket, ensuring a quick and easy solution to installation. Impellers All Sentinel units feature a low energy, Class 1, EC/DC external rotor motor and backward curved impeller assembly specifically chosen for performance and non-overloading characteristics. The assembly is dynamically balanced to DIN ISO 1940 Grade 6.3, duct size 500mm rated IP54, all other sizes IP44 according to BS EN 60529. Ball bearings are greased for life. Insulation is Class ‘B’ (from -25°C to +60°C). All models incorporate internal electronic overload protection and soft start function. Electrical Every Sentinel unit is fitted with a purpose designed common PCB controller incorporating a 16-character backlit alphanumerical x 2 line display with 4 button membrane keypad for fan status and commissioning set up. The enclosure is fitted with a 4-pole 10A isolator that is suitable for fitting a locking device to prevent accidental operation. Motors are single phase 230V +/- 10% / 50/60Hz / 1ph (size 100-400mm) or 400V +/- 10% / 50/60Hz / 3ph (size 500mm), (4 wire systems only). 24V DC power is provided from the controller for powering the matched range of Sentinel switches and sensors. Performance/Sound Extensively tested to BS848 parts 1 & 2. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at reference level of 2 x 10 -5Pa. The inlet/outlet sound power level spectrafigures are dB with a reference of 10 –12Watts. Weatherproof Typical Ordering Designation Ordering codes are similar to existing units with Suffix…. /WP which denotes Weatherproof. Example: SENT100S/CP/WP Accessories For duct accessories see Ducting and Fitting Section. Sentinel D-Box Single Fan •Duct size 100 to 500mm •Performance - Airflow 0.01 to 1.6m 3 /s •Pressure up to 650Pa •Sentinel demand ventilation fan controller with lockable isolator •Aluzinc contstruction suitable for Internal or External mounting •Performance tested to BS848 parts 1 & 2

363 b a dcef spigotoffset air flow hg CL Fan Dimensions (mm) ConstantHierarchy PressureWeightModel Model a b c d e f g h kg SENT100S SENT100S/CP 380 443 100 275 400 192 306 62 8.5 SENT125S SENT125S/CP 380 443 125 275 400 192 306 62 8.5 SENT150S SENT150S/CP 380 443 150 275 400 192 306 62 8.5 SENT200S SENT200S/CP 435 531 200 330 453 287 360 60 12.5 SENT250S SENT250S/CP 435 531 250 330 453 287 360 35 13 SENT315S SENT315S/CP 710 808 315 540 661 458 568 43 34 SENT400S SENT400S/CP 710 808 400 540 661 458 568 43 36 SENT500S SENT500S/CP 898 996 500 735 858 577 765 59 55 Anti-Vibration Duct HierarchyMounts Duct air heater Filter cassette Bag filter cassette attenuator 600mmModelModelStock Ref Stock Ref Stock Ref Stock Ref Stock Ref SENT100S SENT100S/CP 68MP033G 10531100T1 10532100A 10533100 10535100 SENT125S SENT125S/CP 68MP033G 10531125T1 10532125A 10533125 10535125 SENT150S SENT150S/CP 68MP033G 10531150T1 10532150A 10533150 10535150 SENT200S SENT200S/CP 68MP033G 10531200T1 10532200A 10533200 10535200 SENT250S SENT250S/CP 68MP033G 10531250T1 10532250A 10533250 10535250 SENT315S SENT315S/CP 68MP033G 10531315T1 10532315A 10533315 10535315 SENT400S SENT400S/CP 68MP033G 10531400T3 10532400A 10533400 10535400 SENT500S SENT500S/CP 68MP033G 10531500T3 10532500A 10533500 10536500 Accessories For alternative attenuator lengths, refer to Accessories and Controllers section

364 Performance Guide 0 00.02 0.04 0.06 0.080.10.120.14 100 200 300 400 500 600 0 0.03 0.06 0.09 0.12 0.15 0.18Sentinel 100 Single Fan Air Volume m 3 /s Absorbed Power kW Pressure Pa 4 100%80%50%25% m 3 /s @ Pa Speed Motor Phase 0 50 100 200 300 400 500 F.L.C Amps 25 1 m³/s 0.04 0.08 SFP 0.18 Watts 0.01 50 1 m³/s 0.07 0.06 0.04 0.15 SFP 0.29 0.33 0.50 Watts 0.02 0.02 0.02 80 1 m³/s 0.11 0.10 0.09 0.07 0.04 0.5 SFP 0.42 0.47 0.52 0.66 1.13 Watts 0.05 0.05 0.05 0.05 0.05 100 1 m³/s 0.13 0.12 0.11 0.09 0.07 0.05 0.03 0.72 SFP 0.62 0.68 0.74 0.90 1.16 1.60 2.53 Watts 0.08 0.08 0.08 0.08 0.08 0.08 0.08 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 44 39 35 27 24 22 23 29 17 Inlet 43 43 40 35 26 22 22 29 19 Outlet 46 40 41 35 29 23 22 30 20 50 Breakout 50 48 47 37 32 29 26 30 23 Inlet 48 52 62 54 41 34 28 30 35 Outlet 49 52 67 57 48 44 38 31 39 80 Breakout 55 58 56 48 42 41 38 33 31 Inlet 55 58 67 67 53 47 41 35 45 Outlet 56 59 68 68 61 56 51 42 47 100 Breakout 64 63 60 55 47 46 44 38 36 Inlet 57 62 68 71 58 52 47 41 48 Outlet 57 63 71 72 66 62 55 48 52

365 Performance Guide 0.00 0.03 0.09 0.06 0 200 400 500 300 100 600 0.00 0.05 0.10 0.15 0.20 Sentinel 125 Single Fan Air Volume m 3 /s Absorbed Power kW Pressure Pa 25%80%50%4 100% Airflow, m 3 /s @ Pa Speed Motor Phase 0 50 100 200 300 400 500 F.L.C Amps 25 1 m³/s 0.05 0.09 SFP 0.14 Watts 0.01 50 1 m³/s 0.09 0.07 0.05 0.18 SFP 0.21 0.27 0.38 Watts 0.02 0.02 0.02 80 1 m³/s 0.14 0.13 0.11 0.09 0.06 0.02 0.51 SFP 0.35 0.39 0.47 0.58 0.83 2.20 Watts 0.05 0.05 0.05 0.05 0.05 0.04 100 1 m³/s 0.16 0.15 0.14 0.11 0.09 0.07 0.04 0.72 SFP 0.51 0.54 0.58 0.75 0.92 1.17 2.00 Watts 0.08 0.08 0.08 0.08 0.08 0.08 0.08 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 49 40 34 28 26 24 23 29 18 Inlet 46 44 41 35 27 22 22 28 20 Outlet 47 47 42 36 33 27 22 29 21 50 Breakout 53 49 49 39 34 28 23 29 24 Inlet 50 56 58 53 43 37 31 29 33 Outlet 50 56 58 53 43 37 31 29 37 80 Breakout 55 55 58 50 46 39 31 31 33 Inlet 54 64 68 64 55 49 43 36 44 Outlet 56 67 72 66 64 60 55 45 49 100 Breakout 62 58 59 57 52 46 37 33 37 Inlet 58 69 70 70 60 56 48 42 49 Outlet 58 70 71 73 70 67 60 52 54

366 Performance Guide 0 100 200 300 400 500 600 700 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 Sentinel 150 Single Fan Air Volume m 3 /s Absorbed Power kW 0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14 Pressure Pa 4 100%80%50%25%Airflow, m 3 /s @ PaSpeed Motor Phase 0 50 100 200 300 400 500 F.L.C Amps 25 1 m³/s 0.05 0.08 SFP 0.14 kW 0.01 0.01 50 1 m³/s 0.10 0.08 0.06 0.16 SFP 0.19 0.25 0.35 kW 0.02 0.02 0.02 80 1 m³/s 0.15 0.14 0.12 0.10 0.06 0.01 0.48 SFP 0.31 0.34 0.41 0.51 0.85 4.50 kW 0.05 0.05 0.05 0.05 0.05 0.05 100 1 m³/s 0.17 0.16 0.15 0.12 0.10 0.07 0.04 0.74 SFP 0.47 0.51 0.54 0.68 0.81 1.16 2.00 kW 0.08 0.08 0.08 0.08 0.08 0.08 0.08 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 46 43 36 28 26 23 24 29 18 Inlet 46 45 42 37 30 24 23 29 21 Outlet 43 45 42 37 35 31 22 28 22 50 Breakout 50 50 50 40 35 28 24 29 25 Inlet 50 56 60 56 46 41 36 30 35 Outlet 51 59 61 56 53 51 46 33 38 80 Breakout 53 57 57 51 48 42 36 31 33 Inlet 57 65 71 66 58 52 44 42 46 Outlet 56 67 75 67 65 63 56 50 50 100 Breakout 62 61 59 60 54 49 43 37 39 Inlet 59 68 72 76 64 58 51 48 54 Outlet 59 70 74 76 71 70 64 58 56

367 Performance Guide 0 100 200 300 400 500 600 700 800 0.20 0.15 0.10 0.05 0.00 0.25 0.30 Sentinel 200 Single Fan Air Volume m 3 /s 0.00 0.05 0.10 0.15 0.20 Absorbed Power kW Pressure Pa 4 100%80%50%25%Airflow, m 3 /s @ Pa Speed Motor Phase 0 50 100 200 300 400 500 600 700 F.L.C Amps 25 1 m³/s 0.06 0.08 SFP 0.13 kW 0.01 50 1 m³/s 0.14 0.11 0.08 0.16 SFP 0.19 0.25 0.34 kW 0.03 0.03 0.03 80 1 m³/s 0.22 0.20 0.18 0.13 0.09 0.04 0.5 SFP 0.37 0.42 0.46 0.65 0.88 2 kW 0.08 0.08 0.08 0.08 0.08 0.08 100 1 m³/s 0.28 0.26 0.25 0.21 0.18 0.14 0.11 0.07 0.02 0.72 SFP 0.54 0.61 0.65 0.80 0.93 1.20 1.54 2.41 7.75 kW 0.15 0.16 0.16 0.17 0.17 0.17 0.17 0.17 0.16 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 48 41 39 30 29 26 24 31 20 Inlet 50 52 49 43 34 32 24 30 26 Outlet 46 55 48 43 39 42 29 30 28 50 Breakout 55 53 55 42 41 37 34 32 29 Inlet 54 57 67 62 51 44 47 40 41 Outlet 55 59 67 62 58 56 55 46 44 80 Breakout 66 63 63 52 47 46 45 44 37 Inlet 63 66 68 77 64 57 56 53 54 Outlet 65 68 66 76 71 69 65 61 56 100 Breakout 63 69 66 60 53 51 50 50 42 Inlet 68 71 72 77 70 63 61 57 56 Outlet 70 72 69 80 76 76 72 65 62

368 Performance Guide 0 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 100 200 300 400 500 600 700 Sentinel 250 Single Fan Air Volume m 3 /s Absorbed Power kW Pressure Pa 0.00 0.04 0.08 0.12 0.16 0.20 0.24 0.28 50%25%80%4 100%Airflow, m 3 /s @ Pa Speed Motor Phase 0 50 100 200 300 400 500 600 F.L.C Amps 25 1 m³/s 0.07 0.07 SFP 0.11 kW 0.01 50 1 m³/s 0.15 0.11 0.07 0.2 SFP 0.15 0.22 0.34 kW 0.02 0.02 0.02 80 1 m³/s 0.24 0.22 0.19 0.13 0.07 1 SFP 0.26 0.30 0.36 0.52 1 kW 0.06 0.07 0.07 0.07 0.07 100 1 m³/s 0.33 0.30 0.28 0.24 0.19 0.15 0.09 0.01 1.38 SFP 0.37 0.44 0.49 0.59 0.77 0.97 1.48 3.70 kW 0.12 0.13 0.14 0.14 0.15 0.15 0.13 0.04 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 42 42 37 31 29 26 25 31 19 Inlet 48 49 42 38 35 24 24 29 22 Outlet 47 46 41 37 41 29 24 29 24 50 Breakout 52 48 53 43 37 36 34 30 27 Inlet 55 57 65 58 49 43 45 38 39 Outlet 53 57 62 58 54 55 51 36 41 80 Breakout 54 56 57 57 48 46 45 36 36 Inlet 63 65 69 76 62 54 53 49 53 Outlet 63 66 69 72 69 68 62 55 54 100 Breakout 61 63 62 62 55 54 52 45 42 Inlet 68 71 72 80 68 62 59 56 58 Outlet 68 71 70 78 75 75 68 63 60

369 Performance Guide 0 100 200 300 400 500600 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6Sentinel 315 Single Fan Air Volume m 3 /s 0.00 0.10 0.05 0.15 0.25 0.30 0.20 Absorbed Power kW Pressure Pa 50%25%4 100%80%Airflow, m 3 /s @ Pa Speed Phase 0 50 100 200 300 400 F.L.C Amps 25 1 m³/s 0.12 0.08 SFP 0.06 kW 0.01 50 1 m³/s 0.26 0.17 0.06 0.19 SFP 0.10 0.16 0.42 kW 0.03 0.03 0.03 80 1 m³/s 0.44 0.39 0.32 0.18 0.50 SFP 0.18 0.21 0.26 0.46 kW 0.08 0.08 0.08 0.08 100 1 m³/s 0.57 0.53 0.48 0.37 0.26 0.15 1.36 SFP 0.27 0.30 0.34 0.44 0.62 1.09 kW 0.15 0.16 0.16 0.16 0.16 0.16 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 45 42 44 32 30 26 25 31 21 Inlet 47 43 40 31 28 22 23 29 19 Outlet 47 44 42 37 33 27 25 29 21 50 Breakout 54 56 48 46 36 30 26 31 27 Inlet 61 63 54 47 44 39 32 30 31 Outlet 60 63 55 55 51 49 42 31 37 80 Breakout 57 68 60 49 45 42 36 32 38 Inlet 62 78 67 59 55 51 45 40 44 Outlet 62 82 68 66 64 61 55 46 50 100 Breakout 62 69 69 56 53 47 43 36 44 Inlet 67 78 79 66 61 58 53 45 51 Outlet 66 78 78 73 70 68 63 55 56

370 Performance Guide 0 100 200 300 400 500 600 700 800 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Sentinel 400 Single Fan Air Volume m 3 /s Absorbed Power kW Pressure Pa 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 4 100%80%50%25%Airflow, m 3 /s @ Pa Speed Phase 0 50 100 200 300 400 500 600 F.L.C Amps 25 1 m³/s 0.24 0.13 SFP 0.07 kW 0.02 50 1 m³/s 0.50 0.42 0.32 0.59 SFP 0.14 0.19 0.25 kW 0.07 0.08 0.08 80 1 m³/s 0.74 0.71 0.65 0.51 0.37 0.19 1.80 SFP 0.27 0.29 0.33 0.43 0.58 0.96 kW 0.20 0.21 0.21 0.22 0.21 0.18 100 1 m³/s 0.95 0.90 0.85 0.75 0.64 0.52 0.38 0.20 2.47 SFP 0.42 0.45 0.49 0.58 0.69 0.84 1.09 1.79 kW 0.40 0.41 0.42 0.44 0.44 0.44 0.42 0.36 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 44 40 46 35 29 26 24 31 21 Inlet 50 48 48 39 30 23 24 30 23 Outlet 51 48 47 42 38 28 25 29 25 50 Breakout 56 68 54 45 41 34 26 30 33 Inlet 69 74 65 56 52 48 38 33 41 Outlet 68 72 65 62 61 57 48 39 45 80 Breakout 63 73 68 57 52 44 38 32 42 Inlet 74 82 78 68 64 61 56 47 53 Outlet 75 87 77 75 73 70 64 55 58 100 Breakout 67 73 76 63 58 50 44 40 48 Inlet 78 83 87 73 69 66 61 54 59 Outlet 78 85 92 80 79 75 69 61 65

371 Performance Guide 0 100 200 300 400 500 600 700800 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6Sentinel 500 Single Fan Air Volume m 3 /s Absorbed Power kW Pressure Pa 0.2 0.0 0.4 0.6 0.8 1.0 1.2 1.4 1.6 4 100%80%50%25%Airflow, m 3 /s @ Pa Speed Phase 0 50 100 200 300 400 500 600 700 F.L.C Amps 25 3 m³/s 0.46 0.23 0.21 SFP 0.08 0.18 kW 0.04 0.04 50 3 m³/s 0.89 0.76 0.65 0.39 0.67 SFP 0.18 0.21 0.27 0.42 kW 0.16 0.16 0.17 0.16 80 3 m³/s 1.39 1.26 1.17 0.99 0.85 0.63 0.32 1.6 SFP 0.30 0.34 0.36 0.46 0.56 0.76 1.40 kW 0.41 0.43 0.42 0.45 0.47 0.48 0.45 100 3 m³/s 1.60 1.49 1.41 1.27 1.15 1.02 0.88 0.71 0.41 2.1 SFP 0.46 0.49 0.53 0.62 0.73 0.86 1.01 1.19 1.60 kW 0.74 0.73 0.74 0.79 0.84 0.88 0.89 0.85 0.66 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 57 49 43 36 42 26 25 33 25 Inlet 69 55 47 45 42 29 25 32 29 Outlet 68 56 53 50 49 39 31 32 33 50 Breakout 65 69 60 51 48 37 31 32 36 Inlet 70 78 67 63 53 49 42 41 45 Outlet 70 76 70 68 65 60 52 46 49 80 Breakout 69 78 71 61 57 49 42 42 46 Inlet 75 89 78 74 64 61 54 48 56 Outlet 76 86 83 80 77 71 66 59 62 100 Breakout 70 79 75 66 61 52 47 43 49 Inlet 77 86 83 77 68 64 58 53 58 Outlet 78 87 84 83 79 73 69 61 64

372 The Sentinel twin in-line duct fans are as supplied from Vent-Axia Ltd. Manufactured from Aluzinc, Sentinel fan units are internally treated with an ‘O’ class rated, BS476 part 6 & 7, acoustic foam which offers the benefits of high sound absorption, good thermal insulation properties in addition to self extinguishing properties and resistant to ignition. Weatherproof external units incorporate an additional controller shroud. The housing is designed to be as compact as possible for concealed false ceiling applications and Sentinel casings are specially designed to allow the unit to be mounted via its unique mounting bracket, ensuring a quick and easy solution to installation. The unit is suitable for ceiling or floor mounting, non-return dampers can be easily rotated on site to suit. Impellers All Sentinel units feature a low energy, Class 1, EC/DC external rotor motor and backward curved impeller assembly specifically chosen for performance and non-overloading characteristics. The assembly is dynamically balanced to DIN ISO 1940 Grade 6.3, duct size 500mm rated IP54, all other sizes, IP44 according to BS EN 60529. Ball bearings are greased for life. Insulation is Class ‘B’ (from -25°C to +60°C).All models incorporate internal electronic overload protection and soft start function. Electrical Every Sentinel unit is fitted with a purpose designed common PCB controller incorporating a 16-character backlit alphanumerical x 2 line display with 4 button membrane keypad for fan status & commissioning set up. The enclosure is fitted with a 4-pole 10A isolator that is suitable for fitting a locking device to prevent accidental operation. The twin unit controller features automatic 6hr duty/share and run/standby in the event of motor failure. Motors are single phase 230V +/- 10% / 50/60Hz / 1ph (size 100-400mm) or 400V +/- 10% / 50/60Hz / 3ph (size 500mm), (4 wire systems only). 24V DC power is provided from the controller for powering the matched range of Sentinel switches and sensors. Performance/Sound Extensively tested to BS848 parts 1 & 2. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at reference level of 2x10 -5Pa. The inlet/outlet sound power level spectrafigures are dB with a reference of 10 –12Watts. Weatherproof Typical Ordering Designation Ordering codes are similar to existing units with Suffix…. /WP which denotes Weatherproof finish. Example: SENT100T/CP/WP Accessories For duct accessories see Ducting and Fitting Section. Sentinel D-Box Twin Fan •Duct Sizes 100 – 500mm •Performance - Airflow 0.01 to 1.3m 3 /s, Pressure up to 650Pa •Sentinel demand ventilation fan controller with lockable isolator •Latest energy saving EC/DC motors •Aluzinc construction suitable for internal or external mounting •Manufactured controlled to BS EN ISO 9001 •Performance tested to BS848 Part 1 & 2

373 Fan Dimensions (mm) b a øcf e dg HierarchyConstantDuct Diameter mm WeightModelPressure Modela b c d e f g Kg SENT100T SENT100T/CP 610 705 100 591 717 256 622 26 SENT125T SENT125T/CP 610 705 125 591 717 256 622 26 SENT150T SENT150T/CP 610 705 150 591 717 256 622 26 SENT200T SENT200T/CP 801 896 200 703 830 343 734 39 SENT250T SENT250T/CP 925 1020 250 798 925 354 829 48 SENT315T SENT315T/CP 1255 1353 315 1145 1272 536 1176 88 SENT400T SENT400T/CP 1255 1353 400 1145 1272 536 1176 90 SENT500T SENT500T/CP 1492 1590 500 1533 1661 675 1564 175 Accessories Anti-Vibration Duct Hierarchymounts Duct air heater Filter cassette Bag filter cassette attenuator 600mmModelModelStock Ref. Stock Ref. Stock Ref. Stock Ref. Stock Ref. SENT 100T SENT100T/CP 68MP033G 10531100T1 10532100A 10533100 10535100 SENT 125T SENT125T/CP 68MP033G 10531125T1 10532125A 10533125 10535125 SENT 150T SENT150T/CP 68MP033G 10531150T1 10532150A 10533150 10535150 SENT 200T SENT200T/CP 68MP033G 10531200T1 10532200A 10533200 10535200 SENT 250T SENT250T/CP 68MP033G 10531250T1 10532250A 10533250 10535250 SENT 315T SENT315T/CP 68MP033G 10531315T1 10532315A 10533315 10535315 SENT 400T SENT400T/CP 68MP033G 10531400T3 10532400A 10533400 10535400 SENT 500T SENT500T/CP 68MP133G 10531500T3 10532500A 10533500 10536500 For alternative attenuator lengths, refer to Accessories and Controllers section

374 Airflow, m 3 /s @ Pa Speed Motor Phase 0 50 100 200 300 400 500 F.L.C Amps 25 1 m³/s 0.03 0.01 0.08 SFP 0.30 0.90 kW 0.01 0.01 50 1 m³/s 0.06 0.05 0.04 0.16 SFP 0.38 0.44 0.53 kW 0.02 0.02 0.02 80 1 m³/s 0.09 0.08 0.07 0.05 0.03 0.01 0.50 SFP 0.61 0.69 0.79 1.08 1.70 4.90 kW 0.06 0.06 0.06 0.05 0.05 0.05 100 1 m³/s 0.11 0.10 0.09 0.08 0.06 0.05 0.04 0.69 SFP 0.75 0.83 0.92 1.04 1.38 1.66 2.08 kW 0.08 0.08 0.08 0.08 0.08 0.08 0.08 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 45 39 35 27 25 23 23 30 17 Inlet 45 38 41 29 25 21 22 29 18 Outlet 43 39 34 28 24 22 23 28 17 50 Breakout 47 55 47 35 28 24 24 29 23 Inlet 48 50 43 37 32 28 22 28 22 Outlet 47 52 46 42 38 35 26 29 25 80 Breakout 55 64 58 45 38 35 32 32 32 Inlet 54 58 54 51 44 40 31 30 32 Outlet 51 61 59 56 50 49 40 34 37 100 Breakout 65 69 61 50 42 40 37 36 36 Inlet 55 63 56 53 49 45 38 34 35 Outlet 53 65 59 58 54 55 48 39 40 700 600 500 400 300 200 100 0 00.02 0.04 0.06 0.08 0.10 0.12 0.14 Sentinel 100 Twin Fan Air Volume m 3 /s Absorbed Power kW Pressure Pa 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 4 100%50%25%80%Performance Guide

375 0 100 200 300 400 500 600 00.02 0.04 0.06 0.08 0.10 0.12 0.14 Sentinel 125 Twin Fan Air Volume m 3 /s Absorbed Power kW Pressure Pa 0.00 0.06 0.04 0.02 0.08 0.10 0.12 4 100%80%50%25%Airflow, m 3 /s @ Pa Speed Motor Phase 0 50 100 200 300 400 500 F.L.C Amps 25 1 m³/s 0.04 0.09 SFP 0.25 kW 0.01 50 1 m³/s 0.07 0.06 0.04 0.18 SFP 0.31 0.37 0.55 kW 0.02 0.02 0.02 80 1 m³/s 0.12 0.10 0.09 0.07 0.05 0.02 0.51 SFP 0.45 0.54 0.61 0.79 1.06 2.45 kW 0.05 0.05 0.06 0.06 0.05 0.05 100 1 m³/s 0.13 0.12 0.11 0.09 0.08 0.06 0.03 0.72 SFP 0.63 0.68 0.75 0.92 1.04 1.35 2.60 kW 0.08 0.08 0.08 0.08 0.08 0.08 0.08 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 48 39 35 28 25 23 24 30 18 Inlet 46 41 34 27 24 21 22 29 17 Outlet 44 41 36 29 25 21 22 28 17 50 Breakout 49 56 48 35 33 25 25 30 25 Inlet 49 56 50 40 34 31 23 29 26 Outlet 49 60 56 45 40 37 27 29 30 80 Breakout 56 66 59 45 35 31 31 32 33 Inlet 48 60 56 51 44 40 31 30 33 Outlet 53 66 61 56 52 51 45 34 39 100 Breakout 59 72 64 52 41 36 35 36 39 Inlet 52 66 66 56 51 47 38 39 39 Outlet 54 69 64 61 57 57 52 43 44 Performance Guide

376 Airflow, m 3 /s @ Pa Speed Motor Phase 0 50 100 200 300 400 500 F.L.C Amps 25 1 m³/s 0.04 0.08 SFP 0.23 kW 0.01 50 1 m³/s 0.08 0.06 0.04 0.17 SFP 0.25 0.35 0.53 kW 0.02 0.02 0.02 80 1 m³/s 0.12 0.11 0.09 0.07 0.04 0.48 SFP 0.40 0.45 0.58 0.76 1.30 kW 0.05 0.05 0.05 0.05 0.05 100 1 m³/s 0.14 0.13 0.12 0.10 0.08 0.05 0.02 0.71 SFP 0.58 0.63 0.69 0.83 1.03 1.60 3.85 kW 0.08 0.08 0.08 0.08 0.08 0.08 0.08 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 46 40 35 27 26 23 23 29 17 Inlet 45 39 36 28 27 24 22 29 18 Outlet 47 43 36 30 26 23 22 28 21 50 Breakout 48 52 49 37 31 26 23 29 24 Inlet 47 55 48 41 33 30 23 29 25 Outlet 49 59 56 44 42 40 32 29 30 80 Breakout 55 58 58 49 45 41 38 32 33 Inlet 54 62 64 52 45 41 33 32 36 Outlet 55 67 66 57 53 53 47 38 41 100 Breakout 60 63 62 59 51 47 42 41 39 Inlet 58 66 66 59 50 46 39 36 40 Outlet 60 71 67 64 61 61 55 49 47 0 100 200 300 400 500 600 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 Sentinel 150 Twin Fan Air Volume m 3 /s A bsorbed P o w er kW Pressure P a 0.00 0.03 0.06 0.09 0.12 0.15 0.18 4 100%80%50%25%Performance Guide

377 0 100 200 300 400 500 600 700 800 00.05 0.100.15 0.20 0.25 0.30 Sentinel 200 Twin Fan Air Volume m 3 /s 0.00 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.32 Absorbed Power kW Pressure Pa 4 100%80%50%25%Airflow, m 3 /s @ Pa Speed Motor Phase 0 50 100 200 300 400 500 600 700 F.L.C Amps 25 1 m³/s 0.05 0.09 SFP 0.20 kW 0.01 50 1 m³/s 0.11 0.08 0.06 0.2 SFP 0.25 0.35 0.47 kW 0.03 0.03 0.03 80 1 m³/s 0.19 0.17 0.15 0.11 0.07 0.04 1.07 SFP 0.42 0.47 0.54 0.74 1.16 2.00 kW 0.08 0.08 0.08 0.08 0.08 0.08 100 1 m³/s 0.25 0.24 0.23 0.20 0.17 0.13 0.10 0.07 0.04 1.4 SFP 0.64 0.68 0.72 0.83 0.98 1.29 1.69 2.39 4.03 kW 0.16 0.16 0.17 0.17 0.17 0.17 0.17 0.17 0.16 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 47 45 37 40 37 32 25 31 23 Inlet 44 48 36 36 32 25 22 29 21 Outlet 47 49 37 37 33 36 23 30 23 50 Breakout 52 54 54 43 38 41 26 32 29 Inlet 56 59 56 49 41 34 34 31 31 Outlet 52 61 54 53 47 46 41 33 34 80 Breakout 62 64 60 58 45 43 32 35 37 Inlet 55 64 59 64 54 47 42 38 42 Outlet 62 70 61 69 61 58 55 51 48 100 Breakout 67 69 64 63 51 45 38 40 42 Inlet 58 70 63 68 62 55 51 49 47 Outlet 68 75 65 80 67 67 64 60 58 Performance Guide

378 Airflow, m 3 /s @ Pa Speed Motor Phase 0 50 100 200 300 400 500 600 F.L.C Amps 25 1 m³/s 0.05 0.09 SFP 0.18 kW 0.01 50 1 m³/s 0.12 0.09 0.05 0.2 SFP 0.21 0.30 0.54 kW 0.03 0.03 0.03 80 1 m³/s 0.23 0.20 0.17 0.11 0.06 0.92 SFP 0.29 0.35 0.43 0.66 1.10 kW 0.07 0.07 0.07 0.07 0.07 100 1 m³/s 0.30 0.27 0.25 0.20 0.15 0.11 0.07 0.01 1.4 SFP 0.47 0.53 0.57 0.69 0.91 1.26 2.01 12.10 kW 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.12 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 45 41 34 28 26 24 25 31 18 Inlet 47 41 35 33 27 23 24 31 19 Outlet 45 42 36 34 32 25 23 30 20 50 Breakout 49 51 50 39 31 28 25 31 25 Inlet 50 53 51 48 41 33 29 31 29 Outlet 51 55 49 54 45 43 33 31 33 80 Breakout 56 59 58 51 42 36 30 32 33 Inlet 59 62 58 62 52 43 42 36 40 Outlet 58 63 59 67 60 58 53 46 46 100 Breakout 61 64 61 60 49 42 36 35 39 Inlet 64 68 61 69 60 50 50 47 47 Outlet 63 69 62 78 66 67 61 57 56 0 100 200 300 400 500 600 700 800 0 0.05 0.1 0.15 0.2 0.25 0.3Sentinel 250 Twin Fan Air Volume m 3 /s A bsorbed P o w er kW Pressure P a 0.32 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 4 100%50%25%80%Performance Guide

379 0 100 200 300 400 500 600700 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5Sentinel 315 Twin Fan Air Volume m 3 /s A bsorbed P o w er kW Pressure P a 0.21 0.18 0.15 0.12 0.09 0.06 0.03 0 4 100%80%50%25%Airflow, m 3 /s @ Pa Speed Motor Phase 0 50 100 200 300 400 F.L.C Amps 25 1 m³/s 0.09 0.09 SFP 0.11 kW 0.01 50 1 m³/s 0.21 0.13 0.01 0.2 SFP 0.12 0.22 2.40 kW 0.03 0.03 0.02 80 1 m³/s 0.34 0.29 0.25 0.14 0.6 SFP 0.20 0.23 0.28 0.51 kW 0.07 0.07 0.07 0.07 100 1 m³/s 0.46 0.43 0.39 0.32 0.24 0.14 1.4 SFP 0.30 0.33 0.36 0.46 0.62 1.04 kW 0.14 0.14 0.14 0.15 0.15 0.15 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 48 42 37 30 27 25 24 30 19 Inlet 44 42 34 28 23 22 22 29 17 Outlet 47 40 35 32 27 24 23 29 18 50 Breakout 57 50 44 42 30 26 25 30 24 Inlet 53 53 42 40 34 28 24 30 24 Outlet 54 56 47 58 42 38 29 30 35 80 Breakout 61 66 55 44 37 33 27 30 32 Inlet 58 72 56 52 45 39 35 32 37 Outlet 61 79 61 60 55 53 44 40 45 100 Breakout 66 72 71 51 44 38 36 32 43 Inlet 63 74 65 59 52 46 43 40 42 Outlet 66 76 68 69 63 61 53 45 49 Performance Guide

380 Airflow, m 3 /s @ Pa Curve Ref. Motor Phase 0 50 100 200 300 400 500 600 F.L.C Amps 25 1 m³/s 0.16 0.19 SFP 0.13 kW 0.02 50 1 m³/s 0.44 0.34 0.21 0.77 SFP 0.16 0.21 0.34 kW 0.07 0.07 0.07 80 1 m³/s 0.69 0.60 0.54 0.43 0.27 0.10 2.02 SFP 0.31 0.35 0.39 0.50 0.73 1.81 kW 0.21 0.21 0.21 0.22 0.20 0.18 100 1 m³/s 0.80 0.73 0.68 0.59 0.50 0.40 0.27 0.10 2.86 SFP 0.49 0.53 0.56 0.63 0.73 0.93 1.46 3.93 kW 0.39 0.39 0.38 0.37 0.36 0.37 0.39 0.39 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 56 41 41 31 27 25 24 31 20 Inlet 46 44 41 35 27 22 23 29 20 Outlet 48 45 41 38 32 24 24 29 21 50 Breakout 65 62 55 44 38 31 26 30 30 Inlet 60 66 55 50 46 38 30 31 33 Outlet 64 67 59 57 53 48 41 35 39 80 Breakout 74 75 68 56 49 43 38 40 42 Inlet 69 80 67 62 57 50 45 41 46 Outlet 72 81 72 71 66 62 55 48 52 100 Breakout 78 77 75 61 55 48 46 41 48 Inlet 73 82 73 66 62 53 50 45 50 Outlet 75 85 78 77 73 69 63 55 58 0 100 200 300 400 500 600 700800 00.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Sentinel 400 Twin Fan Air Volume m 3 /s 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 A bsorbed P o w er kW Pressure P a 4 100%80%50%25%Performance Guide

381 0 100 200 300 400 500 600 700 800 0 0.2 0.4 0.6 0.8 1 1. 2 1. 4 Sentinel 500 Twin Fan Air Volume m 3 /s A bsorbed P o w er kW Pressure P a 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 4 100%80%50%25%Airflow, m 3 /s @ Pa Speed Motor Phase 0 50 100 200 300 400 500 600 F.L.C Amps 25 3 m³/s 0.35 0.12 0.39 SFP 0.13 0.37 kW 0.05 0.04 50 3 m³/s 0.70 0.59 0.48 0.21 0.67 SFP 0.22 0.28 0.35 0.70 kW 0.16 0.16 0.17 0.15 80 3 m³/s 1.14 1.07 1.00 0.83 0.65 0.48 0.23 1.6 SFP 0.35 0.38 0.43 0.53 0.68 1.00 1.77 kW 0.40 0.41 0.43 0.44 0.44 0.48 0.41 100 3 m³/s 1.34 1.26 1.19 1.04 0.90 0.75 0.59 0.39 2.1 SFP 0.45 0.50 0.54 0.64 0.76 0.93 1.21 1.82 kW 0.60 0.63 0.64 0.67 0.68 0.70 0.71 0.71 Sound DataOctave Band Frequency SWL Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @ 3m 25 Breakout 59 45 45 34 29 24 25 30 22 Inlet 49 45 43 38 33 23 24 31 22 Outlet 48 42 45 42 37 27 25 31 24 50 Breakout 66 64 54 48 39 32 26 32 32 Inlet 60 63 58 54 45 40 35 40 35 Outlet 66 60 64 60 54 51 39 41 41 80 Breakout 72 75 66 59 50 43 37 40 42 Inlet 67 75 70 65 57 51 47 50 46 Outlet 75 74 76 73 66 61 53 51 53 100 Breakout 74 79 69 62 54 46 40 41 46 Inlet 69 80 74 70 61 55 51 51 50 Outlet 78 78 82 78 70 65 60 54 58 Performance Guide

382 Sentinel D-Box Sensors & Controls PLEASE NOTE: These sensors/controls are unique to Sentinel and CANNOT be used with any other product. Ambient Response Humidity Sensor Humidity Sensor control is fixed at 72 - 75%RH. Incorporates a night time ‘set back’ function to avoid nuisance tripping as the humidity level rises when the air cools. An integral pullcord provides a manual override function if required. Can be wired for either On/Off or Trickle/Boost operation. Pullcord override and neon indicator. Changeover relay switch. Operating range: 30% - 90%RH. Ambient operating temperature +5°C to +40°C. 24V DC SELV. Dimensions:87 x 87 x 33mm (H x W x D). Will fit single gang box for surface mounting.Stock Ref432945 Ecotronic Humidity Sensor Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle/Boost operation. Set point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator. Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product. Stock Ref432949 Vent-Axia ThermoSwitch® Automatically switches on fans on either a rise or fall in air temperature. Can be used for Trickle/ Boost operation on either intake or extract systems. Setting range: +6°C to +30°C. Two internal range limit/lockingrings are included to allow setting within a limited temperature range or locking at a fixed set-point. IP20 rated. Sealed sensing mechanism. Mounting direct on surface only. Dimensions: 80 x 104 x 36mm (H x W x D). Volt free switch connection to Sentinel.Stock Ref563502 Air Quality Sensor (AQS) Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H x W x D) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.Stock Ref432953 Vent-Axia Visionex PIR A wall or ceiling person presence detector for use with Sentinel. Can be used in MIN - MAX mode or for direct damper control. Fits any UK single gang mounting box. Adjustable timer overrun (5-25 minutes). Range of detection up to 10 metres. Designed to meet IP43. Ambient operating temperature range 0°C to +50°C. Supply voltage 24V DC SELV.Stock Ref433162

383 7 Day TimeSwitch For applications where regular switching is required at fixed periods or at different times on different days of the week, eg:offices, shops, pubs and restaurants. The 7 Day TimeSwitch gives twelve On or Off positions per day and can be set for 7 days. The cycle will repeat until changed. Volt free switch connection to Sentinel. Analogue clock display and integral time switches for ease of setting. Manual override. Removable clear plastic cover protects timeswitch face. Time base: 7 days. Shortest switching time: 2 hours. Ambient operating temperature range -20°C to +85°C. Dimensions: 104 x 74 x 52mm (H x W x D). Supply voltage 220-240V/1/50Hz.Stock Ref563515 Remote Speed Control Provides infinitely variable Sentinel fan speed control between the 2 set points in Proportional mode. This control does NOT provide an ON/OFF switching facility. Manual control. Located remotely. 24V DC SELV. Ambient operating temperature -5°C to +40°C. Dimensions:84 x 84 x 30mm (H x W x D). Will fit single gang box for surface mounting.Stock Ref426332CO 2Duct ProbeHigh CO 2levels promote increased fatigue andreduced concentration. This sensor monitors CO 2levels in extract ducts from conferenceareas, offices, theatres etc. With Sentinel in Proportional control mode, air extraction rate tracks the CO 2level to improve indoor airquality. 24V DC SELV. 0 - 2000ppm CO 2working range. Auto-calibrating NDIRabsorption sensor. Stable drift compensation. Adjustable probe length. MAX. IP Rating 65.Stock Ref433259 CO 2+ Temp Room Sensor HVAC temperature and carbon dioxide room sensor for ventilation control of residential areas, office areas and classrooms. Used with Sentinel in Proportional control mode. Sensor will monitor both CO 2and temperature levels between theset points, the air extraction rate following the higher of the 2 outputs. 24V DC SELV. 0 - 2000ppm CO 2working range. 0 - 50°C workingrange. Auto-calibrating NDIR CO 2absorption sensor. Thin film platinumtemperature sensor for high accuracy. Dimensions:100 x 84 x 25mm (H x W x D).Stock Ref433257 Remote Fan Status Indicator This remote display unit will indicate the running status and condition of the fan or fans. Can be used in all Sentinel operating modes for fan mounting.24V DC SELV. Directly connects into the SCU. Used for single and twin fan mounting. Ambient operating temperature -5°C to +50°C. Dimensions:86 x 86 x 28mm (H x W x D).Stock Ref433816 Constant Pressure System Accessories PIR Grille PIR grille is on extract grille with an integral flap damper. Suitable for bathrooms and WC’s. The PIR function fully opens the damper when a person is detected. The opening time is fixed at 20 mins. Spigot size is 125mm. 12V AC SELV unit using the main transformer unit supplied. Integral PIR person presence sensor controlling damper. Auto-humidity control damper response at all times. 100° viewing angle. Temperature range 0 - 50°C .Size: 158 x 150 x 35mm (H x W x D). MAX airflow 70m 3 /hr @100 Pa. Stock Ref434184 Dampers Two types available:a) MM type - Opens from a Closed / Minimum Flow position to a Fully Open / Maximum Flow position controlled by switching sensors.b) PC type - opening proportionally when controlled by sensors. Duct sizes available: 100, 125, 150, 200, 250 and 315. Industry standard actuators.Typical ordering designation: DVD size MM or PC Power Supply For those situations where a separate 24V DC SELV supply source is required. 24W output capacity. See Fitting & Wiring instructions for connection details.Stock Ref433193

SentinelTotus 2D-ERV Following on from the highly successful award winning Sentinel demand ventilation system, Vent-Axia has taken the next step by incorporating the Sentinel demand control philosophy with a state of the art high efficiency heat recovery cell to create the Sentinel Totus 2D-ERV,Demand EnergyRecovery Ventilation System. Sentinel Totus 2D-ERV incorporates the same‘Sentinel’ high efficiency EC/DC backward curved motors/impellers, Sentinel Demand Controlled ventilation strategies and a market leading high efficiency counterflow heat recovery cell which achieves up to 90% energy recovery.The Energy recovery capabilities are independently tested and rated to EN308. Sentinel provides a solution to the common problem of ‘Why ventilate a room you’re not using?’ or ‘Why over ventilate a room with only one or two occupants inside?’ Sentinel overcomes many of the issues encountered with a traditional fixed volume ventilation system that is either ON or OFF irrespective of the number of people in the room, risking over ventilation, burning valuable money and is a wasteful use of energy.

Sentinel Totus 2D-ERV 396-401

386 Sentinel Totus 2Demand Energy Recovery Ventilation (D-ERV) is a newheat recovery demand ventilation system designed to meet modern building management control principles. It responds to the exact ventilation requirements of a room at any one time providing airflow only when it is required and to the level that is required, therefore using only the energy that is needed; no more no less, whilst recovering maximum energy from the extracted air and transferring it to the fresh supply air. This overcomes many of the issues encountered with a traditional fixed volume ventilation system that is either ON or OFF irrespective of the occupancy of the room, risking over ventilation, burning valuable money and is a wasteful use of energy. There is an additional benefit to this demand controlled lower speed running, one of reduced noise intrusion, something that in today’s society is becoming more important to end users. Vent-Axia’s dedicated HEVAC team offers: ✓Practical advice on HEVAC selection and installation ✓Guidance on solutions to meet legislation requirements✓Project management and site deliveries ✓After sales support and maintenance information The need to recover energy The high efficiency cell incorporated within the Totus 2range achievesa market leading 90% efficiency (EN308 independently tested). This enables Sentinel Totus 2to recover a third more energy than a 70%efficient device. This high efficiency means that heating and cooling loads associated with ‘extract to waste’ type systems can be reduced by up to 25% in both heating and cooling seasons. This high efficiency also means that expensive after heaters, often required in lower efficiency heat recovery devices, are now not required.The need to save costs Rising fuel prices are placing an increasing burden on organisations as they seek to reduce consumption. Sentinel Totus 2DERV features: ✓High efficiency heat exchanger – up to 90% energy recoveryoffering savings of up to 25% on heating and cooling loads ✓Integral automatic summer bypass - providing free coolingduring summer ✓Single skin construction with 95kg/m 3thermal and acousticfoam insulation (Maxi unit double skinned) ✓Low stand by power only 0.6W ✓Energy efficient EC/DC motors - 1/3 less energy lost to heatthan a conventional AC motor ✓ERP 2015 compliant fans Welcome to the world ofSentinel Demand EnergyRecovery Ventilation

387 The need for system integration With the drive towards ‘whole building cost’ philosophy maintenance schedules and costs are all now essential elements of the project in addition to the initial capital costs. Sentinel Totus 2D-ERV incorporates anumber of integrated features to offer maximum flexibility during design, build and operation including: ✓Air conditioning interlock – to optimise energy recovery ✓Heating system interlock – summer bypass optimisation ✓Interfaces for BMS control and monitoring ✓EC/DC motors with lower maintenance requirements andlonger service life ✓Aluzinc casing - suitable for external installations as standard ✓Optional cowl for roof mounting ✓Integral condensate pump – reduces installation costs andspace requirements ✓In-built automatic frost protection – prevents heat exchangerfreezing at very low temperatures ✓Ability to utilise the frost heaters as top up heat removing theneed for additional duct mounted heaters ✓In-built backlit LCD user control interface which can be remotelymounted to suit site requirements ✓Night time purge facility to reduce overheat during warmsummer periods The need for better health Removal of pollutants, such as moisture, carbon dioxide and external fumesare all important factors in maintaining indoor air quality. Studies within schools have demonstrated that maintaining lower carbon dioxide levels helps create a better learning environment.✓Hierarchical control maintains CO 2levels within levels describedin Building Bulletin 101 ✓Low sound levels meet requirements of Building Design ✓Automatic up to 100% summer bypass providing freesummer cooling ✓Demand control optimising indoor air quality ✓Closed loop control system ensures maximum comfort levels atminimum energy levelsThe need to meet legislation The Energy Performance of Buildings directive is implemented through the UK building regulations. Sentinel Totus 2is fully compliant with bothPart F and L requirements. ✓Meets the requirement of the Building Services ComplianceGuide minimum specific fan power requirements. ✓Market leading 90% heat exchange efficiency independentlytested to EN 308 ✓Meets carbon footprint reduction targets ✓Lowest Specific Fan Power figures of any high efficiencyD-ERV product

388 The need for energy recovery Rising fuel prices are placing an increased burden on organisations asthey seek to reduce consumption. Sentinel Totus 2D-ERV incorporates a number of market leadingtechnologies and control strategies to take commercial heat recoveryventilation to the next level and further reduce energy consumptionand waste. ✓Sentinel demand ventilation control - matching air quality withlow power consumption using high efficiency, low energy EC/ DC motor technology ✓Energy saving control functions - i.Automatic summer bypass - provides free cooling duringsummerii.Low standby power - 0.6 Wattsiii.Night time purge facility - reducing air conditioning start uploads✓System interfaces - to optimise interface with environmentalcontrol systemsi.Air conditioning interlock - to maximise energy recoveryopportunitiesii.Heating system interlock - to optimise summer bypassfunctionalityiii.BMS interfaces - control and monitoring ✓High efficiency energy recovery celli.Up to 90% energy recovery - reducing associated heatingand cooling loads by up to 25%ii.High efficiency eliminates the need for re-heaters e.g.typically at -5˚C ambient, 22˚C room conditions the supplyair temperature is maintained above 19˚C 0 5 10 15 20 90 85 80 70 60 50 kW Energy recovered Energy Recovery Analysis (Winter) -5˚C ambient, 22˚C extract % Efficiency kW R eco ver ed Sentinel Totus kW Energy Recovered Energy Recovery Analysis (Summer) 28˚C ambient, 22˚C extract % Efficiency 0 1 2 3 4 90 85 80 70 60 50 kW R eco ver ed Sentinel TotusAirflow kW HeatSupplym 3 /sEfficiency %recoveredtempo C9016.51 19.3 8515.5918.00.5558014.67 16.6 7012.8413.9 6011.0011.2 509.178.5 Airflow kW CoolSupplym 3 /sEfficiency %Recoveredtempo C 903.67 22.6 853.4622.90.555803.26 23.2 702.8523.8 602.4524.4 502.0425.0

389 The Sentinel Totus 2D-ERV units incorporate a brand new market leadingcounterflow heat exchanger. The Sentinel Totus 2D-ERV range has been independently tested toEN 308 to achieve energy savings of up to 90% and higher in the caseof condensation. The plate heat exchanger is a true counterflow device, incorporatinga special plate edge seal, to enhance air tightness and stability,eliminating the transfer of odours or humidity and ensuring the highestefficiency levels. The aluminium construction makes it insensitive to frost and heat damageand tolerant to pressure imbalance conditions, unlike equivalent paperor plastic variants. This high efficiency energy recovery ventilation system also includesfurther functions to reduce energy usage and maintain high levels ofindoor air quality. ✓ High efficiency EC/DC motors and backward curved impellerswith ‘Sentinel’ demand control logic to optimise IAQ, whilst usingthe minimum amount of energy ✓Built-in automatic up to 100% summer bypass, to take advantageof free cooling opportunities (with air conditioning interlock) ✓Heating system interlock to ensure free cooling is optimised ✓Low standby power 0.6 Watts (PIR actuation) ✓Night time purge facility to reduce overheat during the operationalday and reduce air conditioning start up loads

390 AC Motor with Triac voltage control AC Motor with Transformer voltage control AC Motor with frequency inverter EC/DC Motor 1 2 1800 1600 1400 1200 1000 Electrical input power [Watts] Air Performance 800 600 400 200 0 5000 7000 9000 11000 13000 15000 17000m 3 /h 1 1 1 1 2 1 3 4 1 2 4 4 1 3 Source: ebmpapst ✓Higher efficiency at full speed - at 50% reduction in motor speedgives an 88% reduction in power usage ✓Continuous speed control across the full operating range giving anincreased tolerance to high and low pressure ✓ERP 2015 compliant fans ✓Low noise compared to a step control motor ✓Power input lost as heat is reduced by 1/3 compared to aconventional AC motor ✓Lower maintenance requirements and longer service life 10 20 30 40 50 60 70 80 90 0 50 100 150 200 250 300 350 400 450 500 Output power P2 (W) Motor Ef ficiency (% ) 1 1 1 2 1 3 1 4 1 1 2 1 3 4 EC/DC Motor 3 Phase - AC 1 Phase - AC Shaded pole motor Source: ebmpapst As can be seen from above motor comparisons, the EC/DC motor offers higher efficiencies when compared to AC motors, and also consumes lesspower under speed control, giving both the highest motor efficiency and lowest power consumption across the speed control range. Typical EC/AC Motor Speed Control Comparison Highest Motor Efficiency EC/DC energy saving fan motor benefits

391 Demand control Precise control of the Sentinel Totus 2D-ERV system, driven by theventilation requirements of the room at any one time, means that thesystem is only running to the level required, using energy when it isneeded. A range of sensors are employed to determine the occupancyof the rooms, and manage the system ventilation rates accordingly. Thisoptimises the use of energy whilst meeting the legislation requirementsof the building. This compares to a ‘traditional’ fixed volume system, which in generalis either ‘ON’ or ‘OFF’ often using energy to ventilate an empty or halfoccupied room, over ventilating and wasting energy. System overview The Sentinel Totus 2D-ERV system is made up of 4 elements: ✓Up to 90% energy recovery (EN 308) ✓Low energy EC/DC motors ✓Sentinel Totus 2D-ERV, Demand Energy Recovery control ✓Sensors and Controls The ventilation demands of the room are detected by the wall or ceilingmounted Sentinel Totus 2D-ERV sensors/switches. These communicatewith the Sentinel Totus 2D-ERV unit, which in turn drives the fanto therequired speed to deliver the airflow. As the ventilation is provided tothe room, the sensors continuously feedback to the control unit, drivingthe fan motor to the exact level required in the room at any one time. Hierarchical control The system is controlled by on board electronics, with an LCDdisplay showing fan status and allowing for simple commissioningand installation, whether as a local sensor control unit or linked into abuilding management system. The LCD display unit can be remotelymounted if required. 1. Switched on/off or minimum/maximum level control. In anenvironment such as an office, the system is activated and runs betweenminimum and maximum levels by a choice of sensors: •PIR Detector • Thermostat • Humidistat •BMS (remote enable) 2. Hierarchical – maximum demand multi sensor input used witha combination of sensors, with a defined level of priorities tosimultaneously control a number of atmospheric conditions within aroom, such as a meeting room: • CO 2 /temperature – room mounted • CO 2– duct mounted •Building Management System (0-10V) Constant pressure extract Applied in a discreet central extract system, such as hotel bathrooms orapartment blocks, the system grilles and/or duct dampers are controlledby the presence of a person in the room or by achieving required levelsof humidity. The central system will respond to the demand dependingon the number of active rooms. •PIR/Humidity Extract Grille 125mm •PIR 12 - 70m 3 /h •Humidity: 12m 3 /h – 30% RH to 70m 3 /h -75% RH •Motorised Duct Dampers 100mm - 315mm DiaBuilt in end stop adjustment for setting minimum and maximumvolume.24V Min/Max or 0-10V proportional control options. Motorised DuctDampers – Sensor Control options Each 24V powered extract damper can by controlled by one of thefollowing sensors:- Min-Max (DVDxxx/MM) •AQS- Air Quality Sensor – Room (432953) •PIR Detector – Room (433162) •Thermostat- Room (563502B) •Humidistat- Room (432945) •Proportional 0-10V (DVDxxx/PC) •Carbon Dioxide Sensor – Room (433257) •Carbon Dioxide Sensor – Duct (433259) Note Local 24V power supply required to power Dampers & Sensors.

392 The Sentinel Totus 2D-ERV units are manufactured from Aluzinc sheet andare suitable for internal or external mounting as standard.System technology Sentinel Totus 2D-ERV is a closed loop controlled ventilation system.Employing a range of sensors to manage the system, demand is sensedby PIR, temperature, humidity, air quality or carbon dioxide sensors.Depending on the levels in the rooms, Sentinel Totus 2D-ERV’s fan speedis ramped up or down to control the parameters within the required limits.If the room is unoccupied, the system switches off, saving energy and costto the business.The unit standby power consumption is only 0.6 Watts. The EC/DC energy saving fan motor technology ✓Compliant to ERP 2015, future proofed fan and motor assemblies✓Higher efficiency at full speed - at 50% reduction inmotor speed gives an 87.5% reduction in power usage ✓Continuous speed control across the full operatingrange giving an increased tolerance to high andlow pressure ✓Low noise compared to a step control motor ✓Power input lost as heat is reduced by 1/3 comparedto a conventional AC motor ✓Lower maintenance requirements and longerservice life Sentinel Totus 2D-ERV utilises the latest EC/DC motor technology, whichprovides energy saving benefits even over DC motors. This technology is also infinitely speed controllable and offers increasedenergy savings across the complete speed control range whencompared with conventional inverter drive solutions. The result is higherefficiency, reduced noise, accurate controllability, better speed controldrawing less power and as a result better overall system performance.Volume reduction also increases energy recovery efficiency beyond thepublished figures. Sentinel Totus 2D-ERV can be used in a hierarchical system wheremaximum demand, for example temperature and/or CO 2gives prioritycontrol of the fan speed or a constant pressure system with roommounted PIR/grilles or in-line damper control. Heart of EC/DC motor Rotor with magnet Stator with bearing Integrated electronics Stator lamination Stator winding

393 Sentinel Totus 2D-ERV is a new range of energy recovery ventilationsystems for multi occupancy and variable demand rooms. Using energyefficient EC/DC fans, 90% heat recovery with intelligent sensing andcontrol, the system meets the ventilation requirements of both new buildsand refurbishment projects.Ideal for applications where the rooms are used at different times of the day by a variable number of people, the SentinelTotus 2D-ERV system will monitor occupancy, ventilation rate and airquality, and respond accordingly to maintain the atmosphere withinpreset limits, recovering up to 90% of extracted energy. Typical applications include:✓A network of hotel bathrooms, flats or apartments which requireventilation but are only used for limited periods particularly in themorning and evening ✓School classrooms and lecture theatres which are only occupiedduring lesson time by a variable number of students, but when usedmust keep CO 2levels within prescribed limits ✓Office meeting rooms or open plan areas which again are usedperiodically during the day by a variable number of staff andvisitors, but when occupied must meet required airflow ratesAutomatic sensing and control runs the system according to themaximum demand requirements of the building zone, whether it becarbon dioxide levels, temperature, humidity or air quality – triggeredby people entering or leaving the rooms. Common configurationsinclude Electronic Static Pressure (ESP) controllers for constant pressuresystems. Typical network of hotel bathrooms/flats/apartments Typical school classroom

394 Electronic Static Pressure (ESP) control Typical central extract system using discreet in-line duct mounted dampers controlled by individual room mounted switchingdevices or proportional control sensors (MIN/MAX) within each toilet/bathroom to control individual extract zones.Fan speed control with ESP maintaining target pressure set point as individual zones open/close based on presence ofoccupants or humidity sensor. Central extract controlled system - hotels or apartmentsBMSON/OFF Constant pressure fan control + Damper PIR Grille or ProportionalControl Devices BMSON/OFF CO 2 /Temp Room Sensor CO 2 DuctSensor PIRDetector Network supply and extract hierarchical sensor control Typical networked supply and extract balanced hierarchical System with enabling switching control (ON/OFF, time clockor PIR) and proportional hierarchical maximum demand control from combined temperature and/or CO 2sensors. ProportionalControl Devices BMSON/OFF CO 2 /Temp Room Sensor CO 2 DuctSensor PIRDetector

395 Operation The supply and extract ventilation unit shall be as Sentinel Totus 2D-ERV,as manufactured by Vent-Axia and shall be sized as indicated on thedrawings and shall be in accordance with the particular specification.Supply air to the room shall be pre-heated by the extract air via theintegrated aluminium counterflow heat recovery cell. The Sentinel Totus 2D-ERV unit shall automatically vary the ventilation rate via EC/DCmotors as it receives signals from one of the optional interconnectedsensors. When a signal is received, the fans shall either vary their speedproportionally or on a trickle and boost principle.The unit shall have the facility to commission the supply and extract fansindividually via in-built minimum and maximum speed adjustment. Thefans themselves shall have infinitely variable speed control. Unit specification The unit shall be manufactured with a frameless construction, andincorporate single skinned Aluzinc panels (Maxi unit double skinned)with a high thermal and acoustic efficiency internal insulating foam. Theunit shall be suitableforinternalorexternalmounting as standard.The unit shall have a high efficiency aluminium counterflow heatexchanger, supply and extract filters, automatic summer bypass on upto 100% of airflow, integral minimum and maximum infinitely variablespeed controls with facia mounted failure indication.The unit shall have low energy, high efficiency EC/DC fan/motorassemblies with sealed for life bearings. The impellers shall be highefficiency backward curved centrifugal type fully compliant with ERP 2015. The unit shall have a heat exchanger cell with a thermal efficiency of upto 90% when tested to EN 308. This shall be protected by G4 gradesynthetic filters on supply and extract. Complete with a condensate driptray, internal condensate pump and drain connection. The unit shall incorporate 2 stage electric frost heaters to protect the cellfrom freezing under low ambient conditions. The frost heaters shall beprogrammable to allow operation as a ‘top up’ heating source, withoutthe need for additional duct mounted heaters. The unit shall be constructed with removable top and bottomaccess panels, or side panels for the Maxi unit allowing full maintenance access. The removable panels shall provide access to the following: ✓Supply or extract fan ✓Supply and extract filter ✓Heat exchanger ✓Frost heater Within a separate side access section access shall be provided forwiring termination and set-up/commissioning. The backlit LCD userinterface therein shall be within a separate viewing and access panelallowing commissioning without the need to access the wiring section.This controller can be demounted for remote installation if required. Units shall be as manufactured by Vent-Axia Ltd. Standard controls All Sentinel Totus 2D-ERV units shall incorporate the following functionsintegrally mounted, pre-wired and factory fitted by the manufacturer: ✓Integral infinitely variable fan speed control on supply and extract ✓Integral min/max ventilation control/set point ✓Integral BMS interfaces – control and status indication ✓Cooling and heating interlocks (summer/winter) ✓0-10V speed adjustment ✓Integral on/off or trickle boost function from remote switch, e.g.PIR occupancy detector ✓Automatic frost protection by in-built electric frost heaters ✓User settable night time purge function to purge the roomautomatically over night to reduce morning start up loads withinthe space during hot summer periods ✓The unit shall be controlled by the ‘Sentinel’ control devices(enablers and sensors) as detailed in the schedule or on thedrawings Frost protection and control The control for the in-built electric frost coils shall be 2 stage fullyintegrated and automatic and will ensure the energy recovery celldoes not freeze up under low ambient conditions. The frost protectionsystem will switch in each of the 2 stages as required when ambienttemperature falls below 0˚C.

396 Sentinel Totus 2D-ERV •3 unit sizes covering 500-2000m 3 /h •Sentinel demand ventilation control •Low energy EC/DC motors •Internal or external mounting IPX4 •Up to 90% energy recovery cell •Independently Tested to EN 308 •Proportional or constant pressure control •Performance tested to BS848 Parts 1 & 2 •Manufacture controlled to BS EN ISO 9001Mini and Midi Models are manufactured with a frameless construction from single skinned Aluzinc panels, internally lined with 90kg/m 3highefficiency acoustic and thermally insulating foam (fire retardant to BS476 Part 7 Class 1 & Part 6 Class O). Aluzinc panels allow for all units to be mounted either internally or externally as standard (IPX4). An optional inlet cowl is available for roof mounting applications if required. Maxi units are manufactured with an aluminium frame construction with double skinned Aluzinc panels fitted with 60kg/m 3thermal acousticinsulation.The casing includes an inclined inlet and bellmouth entry which directs the incoming air to the impeller with minimal turbulence. The result is better air management through the unit, less noise, higher efficiency and an increased performance.The housing is designed to be as compact as possible for concealed false ceiling applications and Sentinel Totus2 D-ERV, Demand Energy Recovery casings incorporate top and bottom access panels for maintenance (note Maxi unit is side access). Access panels are sized to enable single man maintenance. Impellers All Sentinel Totus 2D-ERV units feature low energy, Class 1, EC/ DC external rotor motor and backward curved impeller assemblies specifically chosen for performance and non-overloading characteristics. The assembly is dynamically balanced to DIN ISO 1940 Grade 6.3. Ball bearings are greased for life. Insulation is Class ‘B’ (from -25°C to +60°C). All models incorporate internal electronic overload protectionand soft start function. Filters All Sentinel Totus 2D-ERV units are complete as standard with G4replaceable synthetic filters, complete with filter change warning. High grade F6 filters are available as an option. Performance/Sound Extensively tested to BS848 parts 1 & 2. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at reference level of 2 x 10 -5Pa. The inlet/outlet sound power level spectra figuresare dB with a reference of 10 –12watts.Electrical Every Sentinel Totus 2D-ERV unit is fitted with integrated controls anda purpose designed common user interface controller incorporating a 16 character backlit alpha numerical 2 line display with 4 button membrane keypad for fan status and commissioning set up. As standard this is mounted behind a removable perspex viewing pane allowing commissioning without accessing the wiring compartment. The user interface can be removed and remotely fixed if required. The unit also incorporates an isolator that is suitable for fitting a locking device to prevent accidental operation. Motors are single phase 230V +/- 10% / 50/60Hz / 1ph. 24V DC power is provided from the unit for powering the matched range of Sentinel Demand Ventilation switches and sensors. Models Sensor ControlModelStock Ref£Trade MiniTOTUS2MINI291.82 MidiTOTUS2MIDI260.30 MaxiTOTUS2MAXI7007.26 Constant PressureModelStock Ref£Trade Mini/CPTOTUS2MINI/CP4619.87 Midi/CPTOTUS2MIDI/CP4871.71 Maxi/CPTOTUS2MAXI/CP7007.26

397 Dimensions (mm) Sentinel Totus 2Mini/ Midi Totus 2Mini round connections diam. 250 mm E F C G H D I J B A Sentinel Totus 2Maxi E F D G I B A diam. 400mm Model a b c d e f g h i j Mini 1800 1910 - 970 900 450 350 - 55 70 Midi 1900 2020 400 1320 1250 538 350 250 60 70 Maxi 1800 1924 - 1212 1130 530 660 - 60 -

398 0 0.05 0.10 0.15 0.20 0.25 0 100 200 300 400 0.04 0.05 0.06 0.07 0.03 0.02 0.01 0.00 500 600 700 Air Volume m 3 /s Pressure (Pa) Absorbed Power kW 4 100%80%50%25%Sound Data - Mini Model Performance Guide - Mini Model Octave Band Frequency SWL Breakout Speed Test Mode 63 125 250 500 1K 2K 4K 8K dB(A) @ 3m 100% Intake 58 65 69 54 53 54 48 46 33 Supply 55 59 55 50 49 53 37 36 Discharge 59 68 74 66 63 67 55 57 Exhaust 55 60 63 52 50 55 37 36 Breakout 55 53 55 47 43 46 33 31 80% Intake 58 63 69 54 53 52 45 45 31 Supply 53 58 55 46 48 50 34 33 Discharge 59 67 74 64 62 65 53 55 Exhaust 55 59 60 50 48 52 34 34 Breakout 53 52 53 44 42 44 31 30 50% Intake 54 58 64 49 47 42 35 36 25 Supply 49 53 53 39 40 38 26 29 Discharge 54 62 69 56 55 53 43 43 Exhaust 50 54 56 41 41 39 25 29 Breakout 50 48 49 38 35 33 24 27 25% Intake 47 52 48 39 37 30 26 29 17 Supply 48 48 38 33 31 27 22 28 Discharge 49 59 51 48 44 41 30 30 Exhaust 48 50 39 34 31 28 23 29 Breakout 44 45 33 32 28 25 23 26 Airflow, m 3 /s @ Pa Fans Supply Frost Unit Rated Speed 0 50 100 200 300 400 500 600 F.L.C. Voltage Heater Current 100% m³/s 0.21 0.20 0.19 0.16 0.13 0.10 0.07 0.03 2.5 230V/1/ 50Hz 2kW 12A SFP 1.59 1.68 1.77 2.10 2.57 3.33 4.76 11.00 kW 0.33 0.34 0.34 0.34 0.33 0.33 0.33 0.33 80% m³/s 0.19 0.18 0.16 0.13 0.09 0.05 1.85 SFP 1.38 1.46 1.66 2.05 2.88 4.90 kW 0.26 0.26 0.27 0.27 0.26 0.25 50% m³/s 0.13 0.11 0.09 0.04 0.8 SFP 0.85 1.02 1.23 2.63 kW 0.11 0.11 0.11 0.11 25% m³/s 0.09 0.06 0.02 0.35 SFP 0.51 0.77 kW 0.05 0.05 0.04

399 Sound Data - Midi Model Performance Guide - Midi Model Airflow, m 3 /s @ Pa Fans Supply Frost Unit Rated Speed 0 50 100 200 300 400 500 600 F.L.C. Voltage Heater Current 100% m³/s 0.37 0.35 0.33 0.30 0.26 0.22 0.18 0.13 3.0 230V/1/ 50Hz 2kW 12A SFP 1.70 1.79 1.89 2.09 2.41 2.81 3.31 4.28 kW 0.63 0.63 0.63 0.63 0.63 0.62 0.60 0.56 80% m³/s 0.32 0.31 0.29 0.26 0.21 0.17 0.11 0.05 2.5 SFP 1.55 1.60 1.71 1.93 2.29 2.74 3.95 8.04 kW 0.50 0.50 0.50 0.50 0.48 0.47 0.44 0.40 50% m³/s 0.22 0.19 0.17 0.10 1.0 SFP 0.91 1.04 1.19 1.78 kW 0.20 0.20 0.20 0.18 25% m³/s 0.12 0.07 0.5 SFP 0.62 0.97 kW 0.07 0.07 0 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0 100 200 300 400 500 600 700 800 Air Volume m 3 /s 4 100%80%50%25%0.04 0.05 0.06 0.07 0.08 0.03 0.02 0.01 0.00 Absorbed Power kW Pressure (Pa) Octave Band Frequency SWL Breakout Speed Test Mode 63 125 250 500 1K 2K 4K 8K dB(A) @ 3m 100% Intake 66 70 75 60 57 52 50 45 37 Supply 61 62 65 54 52 46 42 41 Discharge 67 80 81 74 68 64 60 54 Exhaust 59 68 69 58 52 49 41 39 Breakout 61 62 63 51 46 42 37 37 80% Intake 64 68 72 57 53 49 45 42 34 Supply 58 61 60 52 49 43 38 39 Discharge 66 79 80 73 65 62 57 50 Exhaust 58 67 68 54 48 44 37 38 Breakout 58 60 58 48 43 40 35 36 50% Intake 59 64 57 46 45 40 35 32 25 Supply 54 56 48 42 40 34 30 31 Discharge 62 71 65 62 56 53 46 41 Exhaust 53 65 53 45 41 37 32 38 Breakout 55 56 44 38 35 31 26 27 25% Intake 58 53 46 37 37 29 25 29 18 Supply 49 46 40 33 32 25 23 30 Discharge 56 56 53 49 44 39 31 30 Exhaust 50 48 43 35 31 26 23 29 Breakout 48 46 35 29 27 24 22 28

400 0 100 200 300 400 500 600 700 800 900 0.00 0.10 0.20 0.30 0.40 0.50 0.60 Air Volume m 3 /s 4 100%80%50%0.00 0.60 0.40 0.20 0.80 1.00 1.20 1.40 1.60 1.80 Absorbed Power kW Pressure (Pa) Sound Data - Maxi Model Performance Guide - Maxi ModelOctave Band Frequency SWL Breakout Speed Test Mode 63 125 250 500 1k 2k 4k 8k dB(A) @3m 100% Intake 67 72 75 72 73 71 68 62 41 Supply 62 65 75 66 65 61 53 46 Discharge 67 70 83 72 75 73 70 65 Extract 62 64 74 63 60 54 44 39 Breakout 66 67 70 53 48 49 41 39 80% Intake 64 71 79 70 69 68 65 58 40 Supply 60 64 77 63 62 57 49 43 Discharge 65 69 82 69 72 70 67 59 Extract 59 63 75 60 57 51 42 38 Breakout 64 63 68 50 53 44 38 36 50% Intake 56 68 57 57 57 53 49 40 30 Supply 52 66 57 51 50 44 35 31 Discharge 56 64 61 56 59 57 50 41 Extract 52 62 52 46 43 37 28 28 Breakout 54 62 52 41 39 38 34 32 25% Intake 48 47 40 37 35 29 23 29 20 Supply 46 43 39 33 31 25 23 29 Discharge 46 45 42 40 41 34 25 29 Extract 48 41 37 31 26 23 23 29 Breakout 46 44 40 32 30 28 26 30 Airflow, m 3 /s @ Pa Fans Supply Frost Unit Speed 0 50 100 200 300 400 500 600 F.L.C. Voltage Heater Current 100% m 3 /s 0.59 0.57 0.55 0.51 0.46 0.40 0.34 0.27 5 230V/1/ 50Hz 4kW 20A SFP 1.71 1.77 1.84 1.98 2.20 2.53 2.97 3.74 kW 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 80% m 3 /s 0.48 0.45 0.43 0.38 0.31 0.24 0.16 3 SFP 1.31 1.40 1.46 1.66 2.03 2.62 3.93 kW 0.63 0.63 0.63 0.63 0.63 0.63 0.63 50% m 3 /s 0.23 0.19 0.16 0.07 1 SFP 0.82 0.99 1.18 2.69 kW 0.19 0.19 0.19 0.19

401 PLEASE NOTE: These sensors/controls are unique to Sentinel Totus 2D-ERV and CANNOT be used with any other product. CO 2+ Temp Room Sensor HVAC temperature and carbon dioxide room sensor for proportional ventilation control. Sensor will monitor both CO 2and temperature levels between the set points, the airflow rate following the higher of the 2 outputs. 24V DC SELV.0 - 2000ppm CO 2working range. 0- 50°Cworking range. Auto-calibrating NDIR CO 2absorption sensor. Dimensions: 100 x 84 x 25mm (H x W x D).Stock Ref 433257560.65 CO2 Duct Probe Sensor monitors CO 2level in extract ducts from conferenceareas, offices, theatres etc. In proportional control mode, air flow rate tracks the CO 2level to improve indoor air quality. 24V DC SELV.0 - 2000ppm CO 2working range. Auto- calibrating NDIR absorption sensor. Adjustable probe length. MAX. IP Rating 65. Dimensions: 80 x 80 x 38mm(H x W x D).Stock Ref433259607.94 Vent-Axia PIR A wall or ceiling mounted presence detector for use with Sentinel Totus 2D-ERV. Can be used in MIN - MAX modeor for direct damper control. Fits any UK single gang mounting box. Adjustable timer overrun (5-25 minutes). Range of detection up to 10 metres. Designed to meet IP43. Ambient operating temperature range 0°C to +50°C. Supply voltage 24V DC SELV. Dimensions: 87 x 87 x 40mm (H x W x D).Stock Ref433162109.98 Vent-Axia ThermoSwitch® Automatically switches on fans on either a rise or fall in air temperature.Used for Trickle/ Boost operation. Setting range: +6°C to +30°C. IP20 rated. Sealed sensing mechanism. Mounting direct on surface only. Dimensions: 80 x 104 x 36mm (H x W x D). Volt free switch connection to Sentinel Totus 2D-ERV,Demand Energy Recovery.Stock Ref56350236.84 Power Supply For those situations where a separate 24V DC SELV supply source is required to power duct dampers. 24W output capacity.See F & W for connection details. Stock Ref43319339.44 F6 Filter Replacement filter to grade F6. Replaces standard G4 filter.ModelStock Ref£Trade Mini4458520.00 Midi4078820.00 Maxi445946 PIR Grille PIR grille is on extract grille with an integral flap damper. Suitable for bathrooms and WCs. The PIR function fully opens the damper when a person presence is detected. The opening time is fixed at 20 mins. Spigot size is 125mm. 12V AC SELV unit using the main transformer unit supplied.Integral PIR person presence sensor controlling damper. Auto-humidity control damper response at all times. 100° viewing angle. Temperature range 0 - 50°C. Dimensions: 158 x 150 x 35mm (H x W x D). MAX airflow 70m 3 /hr @100 Pa. Stock Ref434184231.26 Dampers Two types available: a) MM type - opening shut/MIN to open/MAX controlled by switches and b) PC type - opening proportionally when controlled by sensors. Duct sizes available: 100, 125, 150, 200, 250 and 315.Industry standard actuators. Typical ordering designation: DVD size MM or PC Inlet Cowl For these situations where there is no ducted inlet or extract and the unit is roof mounted. Offers weather protection to ensuring air paths do not recirculate.ModelStock Ref£Trade Mini445832254.51 Midi446591260.30 Maxi441366 Midi Duct Transformation Piece To convert rectangular duct spigot to 315mm dia circular ducting.Stock Ref 44964581.69 Duct Mounted LPHW Coils Top up heating LPHW coils to suit the duct connection size for each Totus. Sized to give 18 to 25°C temperature rise at maximum airflow with water 80/60 as standard. For full details contact Technical Support.ModelStock Ref£Trade Mini4496420.00Midi4496430.00 Maxi4496440.00

Roof Fans With one of the widest ranges of roof mounted fans Vent-Axia can provide a solution to any consultant’s ventilation requirement whether inpublic, commercial or industrial applications. The architects need for an aesthetically pleasing low profile cowl are also provided for. The latest generation of the Vent-Axia Sabre® Sickle fan assisted roof cowls incorporate the very latest FE2 Owlett impeller plate axial fans offering improved performance over the previous ranges with up to 7dB(A) reduction in sound and up to 15% improvement in efficiency ensuring the best available fan performance in its class. The advanced blade design is matched to a purpose designed external rotor motor to ensure unrivalled reliability and controllability.Optional integral backdraught shutters limit heat loss from the building when the unit is off.

NEW High Temperature Roof Fans (RDM) 404-407 Sabre ®Sickle fan assisted roof cowl (VSR) 408-415 Mixed Flow Roof Fans (RMH) 416-421 Lo-Carbon Energy Saver MXRoof Fans (MX) 422-425

404 Designed to comply with the latest EU regulations for Ventilation units the new RDM range of roof extract fans from Vent-Axia are suitable for both general ventilation and kitchen ventilation with in-duct temperatures of up to 120°C. Motors High performance centrifugal impeller with backward curved blades directly fitted to a premium efficiency IE3 motor protected to IP55. The motor is fitted with PTC Thermistors as standard and is designed for best operation through a frequency inverter with sine filters. Balanced statically and dynamically according to DIN ISO 1940. Meets the efficiency requirements of Regulation EU1253/2014 ErP Lot 6 for ventilation units. Performance The fan performance is tested in accordance with ISO 5801.Electrical All models are suitable for 380-415 / 3 / 50 electrical supply. Sound Sound measurements are made in accordance with DIN 45635-38.Inlet side is in accordance with ISO 5136 as an in-duct figure. Discharge side is in accordance with DIN 45635-1 and BS848 part 2 as a free field figure.Accessories Flat roof upstandManufactured from galvanised sheet steel with sound absorbing and thermal lining. Inclined roof upstand Upstand for inclined roof made of aluminium sheet, provided with sound and thermal insulation, available in steps of 5 degrees from 5 to 45 degrees roof pitch - to be advised at time of order.Intake flexible connectionFlanged flexible connection to prevent the transmission of vibration to other parts of the installation. Flange dimensions are in accordance with DIN 24 155 - 2. Protection grid for intake Use in installations with an open inlet. Inlet silencerThe tubular inlet silencer has a square flange on the side nearest to the roof unit for bolting to the respective flat roof upstand. It slides inside the upstand, while the opposite end can take either additional ducting or an inlet cone.The exterior skin is made of galvanised sheet steel, and the interior of galvanised perforated plate. The cavity between them is filled with non-flammable acoustic material.There is no central core of material, so any pressure loss will be insignificant. Stock Ref dB 63 125 250 500 1k 2k 4k 8k 475820/475821 7 0 3 5 10 14 13 8 7 475822/475823/475824 8 2 4 6 12 16 14 10 8 475825 / 475826 12 2 4 8.5 17 20 15 12 10 475827/475828 13 3 5 9 17 21 15 12 10 475829/475830 13 3 5 10 18 22 16 12 10 For full details please contact Technical Support 0344 856 0595. NEW High Temperature Roof Fans (RDM) •Handles air temperatures up to +120°C •High performance directed vertical discharge•Motor mounted outside of the airstream •Manufactured from aluminium •IP65 service isolator •Integral backdraught shutter •Manufacture controlled to ISO 9001 •Performance tested to ISO 5801 •2 Year Guarantee

405 Dimensions (mm) Cable entry m l al e e i k h c b a f g d Stock Ref a al b c d e f g h i k l m RDM3E25284D 600 6x60° 543 440 32 M6 440 135 330 12 286 138 138 RDM3E25314D 600 6x60° 543 440 32 M6 440 135 330 12 286 138 138 RDM3E35354D 770 6x60° 635 600 32 M8 570 170 450 12 395 216 192 RDM3E354043 770 6x60° 635 600 32 M8 570 170 450 12 395 216 192 RDM3E354543 770 6x60° 635 600 32 M8 570 170 450 12 395 216 192 RDM3E455043 985 6x60° 775 750 32 M8 730 208 590 14 487 282 222 RDM3E455643 985 6x60° 775 750 32 M8 730 208 590 14 487 282 222 RDM3E455663 985 6x60° 775 750 32 M8 730 208 590 14 487 282 222 RDM3E566363 1125 8x45° 946 940 40 278 920 278 750 14 605 335 317 RDMFE567163 1125 8x45° 946 940 40 278 920 278 750 14 605 335 317 RDMFE718063 1625 8x45° 1195 1270 65 M10 1230 380 1050 14 751 500 445 RDMFE719063 1625 8x45° 1195 1270 65 M10 1230 380 1050 14 751 500 445 Accessories FanStock Ref Flat roof upstandStock Ref Inclined roof upstandStock Ref Intake flexible connectionStock Ref Protection grid for intakeStock Ref Inlet silencerStock Ref RDM3E25284D 475776 475787 475798 475809 475820 RDM3E25314D 475777 475788 475799 475810 475821 RDM3E35354D 475778 475789 475800 475811 475822 RDM3E354043 475779 475790 475801 475812 475823 RDM3E455043 475780 475791 475802 475813 475824 RDM3E455643 475781 475792 475803 475814 475825 RDM3E455663 475782 475793 475804 475815 475826 RDM3E566363 475783 475794 475805 475816 475827 RDMFE567163 475784 475795 475806 475817 475828 RDMFE718063 475785 475796 475807 475818 475829 RDMFE719063 475786 475797 475808 475819 475830 Note.The accessories listed are bespoke to this product range, for full dimensional details please contact Technical Support

406 Performance Guide 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 0 100 200 300 400 500 600 700 800 900 1000 00.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 1 3 4 1 1 2 5 6 Air Volume m 3 /s Absorbed Power KW Pressure Pa Stock Ref Supply r.p.m CurveRef 0 100 200 300 400 500 600 700 800 900 Motor kW FLC SC RDM3E25284D 400/3/50 1350 1 m 3 /s 0.49 0.37 0.07 0.25 0.84 2.52 kW 0.14 0.16 0.12 RDM3E25314D 400/3/50 1350 2 m 3 /s 0.68 0.53 0.26 0.25 0.84 2.52 kW 0.18 0.21 0.19 RDM3E35354D 400/3/50 1370 3 m 3 /s 1.01 0.89 0.72 0.10 0.37 1.11 3.33 kW 0.28 0.34 0.37 0.22 RDM3E354043 400/3/50 1440 4 m 3 /s 1.43 1.28 1.13 0.94 0.58 0.55 1.25 3.75 kW 0.50 0.57 0.65 0.68 0.58 RDM3E455043 400/3/50 1420 5 m 3 /s 2.79 2.63 2.44 2.19 1.96 1.69 1.31 0.18 1.5 3.6 10.8 kW 1.34 1.47 1.61 1.68 1.75 1.77 1.68 0.96 RDM3E455643 400/3/50 1430 6 m 3 /s 3.79 3.61 3.41 3.19 2.99 2.74 2.46 2.08 1.49 0.33 3 6.4 19.2 kW 2.41 2.59 2.74 2.85 2.98 3.05 3.07 2.98 2.72 1.93 Sound Power Level Spectra dB (re 10 –12 Watts) Stock Ref 125 250 500 1k 2k 4k 8k dBA RDM3E25284D Inlet 75 66 60 57 52 49 47 44 RDM3E25284D Outlet 63 62 59 60 56 53 52 44 RDM3E25314D Inlet 76 66 61 61 53 51 45 46 RDM3E25314D Outlet 73 62 60 62 57 54 50 47 RDM3E35354D Inlet 82 73 67 60 56 52 51 51 RDM3E35354D Outlet 72 70 68 66 65 61 58 52 RDM3E354043 Inlet 84 76 70 64 58 54 52 53 RDM3E354043 Outlet 77 73 70 70 67 64 61 55 RDM3E455043 Inlet 93 81 76 72 66 67 62 61 RDM3E455043 Outlet 91 82 78 80 73 71 67 64 RDM3E455643 Inlet 96 86 81 78 74 72 68 66 RDM3E455643 Outlet 90 85 83 82 79 76 74 67

407 Performance Guide 0.12 0.10 0.08 0.06 0.04 0.02 0 0 200 400 600 800 1000 1200 0 1 2 3 4 5 6 7 8 9 1 3 4 1 1 2 5 Air Volume m 3 /s Absorbed Power kW Pressure Pa Stock Ref Supply r.p.m CurveRef 0 100 200 300 400 500 600 700 800 900 1000 Motor kW FLC SC RDM3E455663 400/3/50 935 1 m 3 /s 2.50 2.19 1.82 1.31 0.10 0.75 2.1 6.3 kW 0.74 0.86 0.95 0.92 0.47 RDM3E566363 400/3/50 950 2 m 3 /s 3.68 3.36 2.99 2.56 1.86 0.01 1.5 3.7 11.1 kW 1.23 1.41 1.57 1.67 1.56 0.66 RDMFE567163 400/3/50 965 3 m 3 /s 4.39 4.00 3.67 3.27 2.81 2.22 0.79 3 6.9 20.7 kW 1.64 1.77 2.04 2.21 2.27 2.20 1.59 RDMFE718063 400/3/50 970 4 m 3 /s 6.64 6.28 5.89 5.42 4.97 4.56 3.97 3.03 0.06 4 9 27 kW 3.00 3.35 3.66 3.85 4.06 4.29 4.32 4.00 1.68 RDMFE719063 400/3/50 950 5 m 3 /s 8.83 8.50 8.14 7.67 7.06 6.53 6.11 5.39 4.53 3.72 1.53 7.5 14.5 43.4 kW 5.68 6.15 6.65 6.98 7.08 7.30 7.62 7.51 7.14 6.91 5.03 Sound Power Level Spectra dB (re 10 –12 Watts) Stock Ref 125 250 500 1k 2k 4k 8k dBA RDM3E455663 Inlet 88 76 70 67 62 60 57 55 RDM3E455663 Outlet 77 75 73 72 69 66 63 57 RDM3E566363 Inlet 92 78 73 69 65 64 56 57 RDM3E566363 Outlet 85 79 77 74 71 68 62 59 RDMFE567163 Inlet 93 79 72 71 66 64 56 58 RDMFE567163 Outlet 80 81 76 76 73 69 63 61 RDMFE718063 Inlet 92 83 76 73 68 66 60 60 RDMFE718063 Outlet 86 84 79 77 74 71 67 63 RDMFE719063 Inlet 101 86 83 78 72 68 62 66 RDMFE719063 Outlet 91 87 84 82 78 74 70 67

408 Sabre Sickle Fan Assisted Roof cowls (VSR)•Swept impeller with Aerofoil blades, winglets andserrated trailing edge for optimum performance •Fully assembled cowl, separate plate axial fan •Optional backdraught shutters and birdguard •Moulded from recyclable polymeric material •One shot die cast aluminium impeller dynamically balancedfor smooth operation •Resistant to UV light •Speed controllable•Thermal Overload Protection for motor protection•Operating temperature up to 70°C The latest generation of the Vent-Axia Sabre ®Sickle Fan assisted roof cowlsincorporate the very latest FE2 Owlett plate axial fans supplied separate to the cowl offering improved performance over the previous ranges with up to 7 dB(A)reduction in sound and up to 15% improvement in efficiencyensuring the best available fan performance in its class. The advanced blade design is matched to a purpose designed external rotor motor to ensure unrivalled reliability and controllability. All cowl and roof mounting plates are moulded from specially formulated polymeric materials, which are high impact resistant and provide a rigid profile against strong winds and are resistant to UV light. Standard Colour BS00A05. Alternative colours are available on request. Suitable for flat or inclined roofs (max. angle 30°). Sabre ®Sickle Fanassisted roof cowls are designed for either kerb or purlin box mounting. All sizes are fitted with inlet wire guards, giving protection to BS 848 part 5. Bird guards are available as optional accessories. Design and Development Using a combination of NASA research into wing performance and winglets, coupled with a study of bird flight has enabled the development of the best available Sickle blade profile. Matching this to a purpose designed close fitting casing ensures best use of this blade technology thereby reducing noise and improving the performance in cased axial fans. Impellers The impellers incorporate the latest in Sickle blade aerofoil technology to ensure minimum sound and maximum performance. The motors and impellers are factory matched, statically and dynamically balanced to ISO 1940 part 1, Quality Class G.6.3. Motors The external rotor motors are specifically designed and styled for this range of fan. Ball bearings are greased for life. Sizes 315 – 710 motors are protected to IP54 against dust and moisture complying with BS EN 60529. They have ribbed aluminium body castings for efficient cooling with Motor insulation to Class ‘F’ (from -40°C to + 70°C). Speed controlled sizes 450to 710, 6 & 8 pole motors are only suitable for operating temperatures of up to 40°C. Electrical The Sabre ®Sickle Fan assisted roof cowls range is available for either singlephase 220-240V 50 Hz capacitor start and run or three phase 380-415V 50Hz. Motors are fitted with Thermal Overload Protection which should be wired into all controller circuits and into starter contacts to prevent motor damage due to overloading / overheating. Speed Control Units are suitable for speed control by either electronic, voltage reduction or frequency inverters where permissible. For optimum efficiency and controllability Vent-Axia recommend the use of the eDemand Inverter controller to give close control via sensors or manual control. Terminal Box An IP54 terminal box is supplied with all models with M20 x 1.5mm gland entry offering protection against dust and water. Performance The fan performance is in accordance with tests to ISO 5801. Sound Levels Fan sound levels are measured in a reverberant chamber in accordance with ISO 3744 Part 1. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10 -5 Pa(20 micro-Pascal). The sound power level spectra figures are dB with a reference level of 10 -12Watts (1 pico-watt).To ensure minimum noise levels during speed control, either an auto transformer or eDemand inverter speed control is recommended.

409 Fan Dimensions (mm) Kg max Dia abcd e fKerb detail 250 700 475 737 411 97 675 11.7 315 700 475 737 411 97 675 12.8 355 700 475 737 411 97 675 13.8 400 800 575 830 466 97 775 19.2 450 800 575 830 466 97 775 24.8 500 950 715 1000 579 100 915 30.3 560 950 715 1000 579 100 915 37 630 1230 840 1100 731 105 1040 64 710 1230 840 1100 731 105 1040 50 Packing Sabre ®Sickle Fan assisted roof cowls consist of two elements, a boxed cowlassembly and a plate mounted fan. Fan & cowl are supplied separately to assist with transportation and are quickly assembled on site. Accessories A full range of accessories is available for the Sabre ®Sickle Fan assistedroof cowls:•Electronic Speed Controllers •Auto Transformer Speed Controllers•eDemand Inverter Speed Control •D.O.L. Starters •Purlin Boxes •Backdraught Shutters •Bird Guards •Roof Attenuators

410 Performance Curve Performance Guide Sound Power Level Spectra dB (ref 10 –12Watts) IP Motor F.L.C S.C.Volume m 3 /s @ Pa dB(A) @ Stock Ref Supply Rating kW Amps Amps Poles rpm Curve 0 25 50 75 100 3.0m VSR25012 230/1/50 IP54 0.12 0.54 2.16 2 2160 1 1 Volume m 3 /s 0.29 0.26 0.22 0.18 0.07 50 Power Watts 110 115 118 121 125 VSR25014 230/1/50 IP54 0.05 0.24 0.96 4 1370 1 2 Volume m 3 /s 0.09 0.04 37 Power Watts 46 48 VSR31514 230/1/50 IP54 0.12 0.54 2.16 4 1360 1 3 Volume m 3 /s 0.49 0.44 0.37 0.27 45 Power Watts 111 118 124 130 VSR31534 400/3/50 IP54 0.12 0.39 1.7 4 1450 1 4 Volume m 3 /s 0.44 0.36 0.29 0.19 47 Power Watts 105 115 117 120 VSR35514 230/1/50 IP54 0.13 0.56 2.24 4 1260 1 5 Volume m 3 /s 0.72 0.64 0.54 0.40 46 Power Watts 132 141 151 162 VSR35534 400/3/50 IP54 0.19 0.4 1.6 4 1390 1 6 Volume m 3 /s 0.79 0.72 0.61 0.49 48 Power Watts 152 168 176 178 Stock Ref 63Hz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 8KHz dB(A) @ 3.0m VSR25012 65 70 68 66 64 66 62 55 50 VSR25014 56 63 56 54 53 53 49 41 37 VSR31514 71 70 65 60 58 59 55 47 45 VSR31534 75 71 62 60 61 62 59 51 47 VSR35514 67 70 67 64 58 60 53 45 46 VSR35534 74 66 61 63 64 63 59 53 48 00.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 S tatic Pressure (P a) Volume (m 3 /s) 100 75 50 25 0 00.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 S tatic Pressure (P a) Volume (m 3 /s) 100 75 50 25 0 250 - 355 dia. - 2 & 4 Pole 1 Phase3 Phase 1 1 2 3 5 6 4

411 Performance Guide Performance Curve Sound Power Level Spectra dB (ref 10 –12Watts) IP Motor F.L.C S.C.Volume m 3 /s @ Pa dB(A) @ Stock Ref Supply Rating kW Amps Amps Poles rpm Curve 0 25 50 75 100 125 3.0m VSR40014 230/1/50 IP54 0.24 1.05 4.2 4 1340 1 1 Volume m 3 /s 0.81 0.74 0.63 0.51 0.35 46 Power Watts 166 195 200 210 240 VSR40034 400/3/50 IP54 0.23 0.46 1.6 4 1360 1 2 Volume m 3 /s 0.80 0.74 0.64 0.52 0.38 47 Power Watts 160 170 190 205 220 VSR45014 230/1/50 IP54 0.6 2.9 11.6 4 1320 1 3 Volume m 3 /s 1.69 1.63 1.50 1.38 1.20 0.99 49 Power Watts 480 500 520 530 540 550 VSR45034 400/3/50 IP54 0.54 1.1 4.4 4 1350 1 4 Volume m 3 /s 1.71 1.63 1.53 1.42 1.26 1.10 49 Power Watts 440 460 480 505 520 530 VSR45016 230/1/50 IP54 0.19 0.9 3.6 6 910 1 5 Volume m 3 /s 1.06 0.90 0.68 41 Power Watts 165 175 180 VSR45036 400/3/50 IP54 0.36 0.66 2.64 6 1020 1 6 Volume m 3 /s 1.38 1.18 0.99 0.75 44 Power Watts 325 350 360 380 Stock Ref 63Hz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 8KHz dB(A) @ 3.0m VSR40014 72 73 66 62 60 59 54 48 46 VSR40034 67 67 61 60 60 59 54 48 47 VSR45014 67 69 71 63 63 63 59 53 49 VSR45034 72 70 65 65 64 64 59 53 49 VSR45016 57 62 59 56 56 56 50 41 41 VSR45036 71 66 60 60 60 58 51 43 44 00.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 S tatic Pressure (P a) 125 100 75 50 25 0 Volume (m 3 /s) 00.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 S tatic Pressure (P a) 125 100 75 50 25 0 Volume (m 3 /s) 400 - 450 dia. - 4 & 6 Pole1 Phase3 Phase 1 1 2 6 3 5 4

412 Performance Curve Performance Guide Sound Power Level Spectra dB (ref 10 –12Watts) IP Motor F.L.C S.C.Volume m 3 /s @ Pa dB(A) @ Stock Ref Supply Rating kW Amps Amps Poles rpm Curve 0 25 50 75 100 125 150 175 200 225 3.0m VSR50014 230/1/50 IP54 0.72 3.2 12.8 4 1230 1 1 Volume m 3 /s 1.81 1.67 1.53 1.31 1.17 0.92 51 Power Watts 630 660 670 690 720 740 VSR50034 400/3/50 IP54 0.84 1.45 5.8 4 1340 1 2 Volume m 3 /s 1.96 1.83 1.70 1.56 1.40 1.25 1.00 0.61 52 Power Watts 620 650 680 720 740 750 800 825 VSR50016 230/1/50 IP54 0.27 1.25 5 6 910 1 3 Volume m 3 /s 1.08 0.94 0.69 0.36 44 Power Watts 250 265 280 295 VSR50036 400/3/50 IP54 0.54 0.96 3.84 6 940 1 4 Volume m 3 /s 1.40 1.14 0.89 0.58 47 Power Watts 470 500 520 540 VSR56014 230/1/50 IP54 1.15 5 20 4 1330 1 5 Volume m 3 /s 2.33 2.25 2.11 2.03 1.87 1.67 1.56 1.28 1.04 0.80 62 Power Watts 810 830 870 890 900 980 1000 1050 1100 1110 VSR56034 400/3/50 IP54 1.05 2.2 8.8 4 1280 1 6 Volume m 3 /s 2.44 2.36 2.25 2.10 1.86 1.69 1.50 1.14 0.86 57 Power Watts 742 800 840 860 910 920 940 1014 1044 VSR56016 230/1/50 IP54 0.39 1.8 7.2 6 930 1 7 Volume m 3 /s 1.55 1.40 1.19 0.97 0.59 50 Power Watts 369 394 415 438 458 VSR56036 400/3/50 IP54 0.58 1.1 4.4 6 910 1 8 Volume m 3 /s 1.81 1.55 1.29 1.00 0.47 51 Power Watts 489 518 542 556 576 Stock Ref 63Hz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 8KHz dB(A) @ 3.0m VSR50014 71 75 67 63 67 68 60 52 51 VSR50034 74 72 66 66 68 68 62 56 52 VSR50016 66 72 70 55 59 58 51 43 44 VSR50036 77 77 72 66 64 61 54 47 47 VSR56014 79 78 74 74 77 77 73 66 62 VSR56034 84 78 76 74 75 74 70 63 57 VSR56016 75 73 66 65 67 66 60 54 50 VSR56036 77 77 67 66 67 66 60 54 51 500 - 560 dia. - 4 & 6 Pole1 Phase3 Phase Volume (m 3 /s) 00.5 1.0 1.5 2.0 2.5 3.0 225 200 175 150 125 100 75 50 25 0 S tatic Pressure (P a) Volume (m 3 /s) 00.5 1.0 1.5 2.0 2.5 3.0 225 200 175 150 125 100 75 50 25 0 S tatic Pressure (P a) 1 1 7 3 5 2 8 6 4

413 Performance Curve Performance Guide Sound Power Level Spectra dB (ref 10 –12Watts) IP Motor F.L.C S.C.Volume m 3 /s @ Pa dB(A) @ Stock Ref Supply Rating kW Amps Amps Poles rpm Curve 0 25 50 75 100 125 150 175 200 225 250 275 3.0m VSR63034 400/3/50 IP54 2.4 4.6 18.4 4 1320 1 1 Volume m 3 /s 5.00 4.85 4.62 4.49 4.32 4.13 3.85 3.63 3.40 3.10 2.74 2.48 62 Power Watts 2305 2350 2400 2450 2500 2540 2587 2600 2628 2630 2639 2659 VSR63016 230/1/50 IP54 0.6 2.8 11.2 6 910 1 2 Volume m 3 /s 2.39 2.21 1.88 1.60 1.35 52 Power Watts 568 603 650 679 710 VSR63036 400/3/50 IP54 1.5 2.6 10.4 6 1040 1 3 Volume m 3 /s 3.85 3.55 3.36 3.10 2.85 2.42 2.02 57 Power Watts 1538 1550 1593 1610 1645 1661 1666 VSR71016 230/1/50 IP54 0.95 4.4 17.6 6 850 1 4 Volume m 3 /s 3.15 2.93 2.69 2.32 1.97 1.63 0.99 52 Power Watts 607 666 700 760 808 850 950 VSR71036 400/3/50 IP54 0.94 1.7 6.8 6 900 1 5 Volume m 3 /s 3.33 3.10 2.79 2.48 2.21 1.90 1.29 49 Power Watts 560 620 700 768 813 861 920 Stock Ref 63Hz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 8KHz dB(A) @ 3.0m VSR63034 85 80 77 75 78 77 71 66 62 VSR63016 74 71 73 68 68 66 60 54 52 VSR63036 84 75 71 71 74 71 65 59 57 VSR71016 81 81 72 69 70 67 61 57 52 VSR71036 69 69 68 67 68 65 59 52 49 630 - 710 dia. - 4 & 6 & 8 Pole1 Phase3 Phase Volume (m 3 /s) 0 12 34 150 125 100 75 50 25 0 275 250 225 200 175 150 125 100 75 50 25 0 S tatic Pressure (P a) S tatic Pressure (P a) Volume (m 3 /s) 0 1 2 3 4 5 6 1 1 2 4 3 5

414 Size ab c d e f g 250/315/355 625 90 240 765 400 590 460 400/450 725 90 240 865 500 705 565 500 890 70 250 990 650 864 640 560 890 70 250 990 650 864 700 630 1030 75 250 1140 760 985 775 710 1030 75 250 1140 760 985 840 Purlin Box (Manufactured from 1.5mm pre-galv. mild steel) c b a b 0 RESIST ANCE (Pa) 160 0 MEAN DUCT VELOCITY m/s 20 40 60 80 1 2 3 4 5 6 7 8 9 10 140 120 100 1 2 1 1 Vertical Backdraught Shutters Pressure Drop for Roof Cowl only Percentage reduction in Size performance at 4 pole speeds 315 7% 355 12% 400 10% 450 3% 500 4% 560 6% 630 3% 710 7%For 6 and 8 pole fans, reduce percentages by ratio of fan speeds.Stock Free area Resistance Cowl only Ref m 2 curve weight kg RCZ300 0.099 1 1 7.5 RCZ400 0.159 1 2 9 RCZ500 0.246 1 2 13 RCZ630 0.396 1 3 19 0 RESIST ANCE (Pa) 100 0 MEAN DUCT VELOCITY m/s 1 2 3 4 5 6 7 8 9 10 10 20 30 40 50 60 70 80 90 1 2 1 3 1 1 Roof Attenuators Typical Installation Optional bird guard Optional shutter offersprotection againstbackdraughts Vacuum formed UV stabilised roof cowlassembly asstandard. OptionalcoloursavailableBase drilled on site M10 Nutinserts inpurlin box MAX. Pitch 30° Structuraltrimmer Vent-Axia purlin box Stock Kg Free Resistance Ref a b c d approx area m 2 curve RAZ300600 455 535 505 600 18 0.156 1 1 RAZ400600 555 635 605 600 22 0.245 1 2 RAZ500600 635 790 745 600 31 0.416 1 2 RAZ600600 770 935 890 600 44 0.616 1 3 RAZ300900 455 535 505 900 21 0.156 1 1 RAZ400900 555 635 605 900 28 0.245 1 2 RAZ500900 635 790 745 900 39 0.416 1 2 RAZ600900 770 935 890 900 52 0.616 1 3 RAZ3001200 455 535 505 1200 25 0.156 1 1 RAZ4001200 555 635 605 1200 35 0.245 1 2 RAZ5001200 635 790 745 1200 48 0.416 1 2 RAZ6001200 770 935 890 1200 61 0.616 3 2 Recommended maximum duty velocity 10m/s

415 Stock Ref Supply Electronic Controller 5 Step AutoTransformer D.O.L StarterOverload eDemandVoltage Control eDemand 3phInverter VSR25012 230/1/50 W10303102M 10314102 444744 444698 444164 - VSR25014 230/1/50 W10303102M 10314102 444744 444697 444164 - VSR31514 230/1/50 W10303102M 10314102 444744 444699 444164 - VSR31534 400/3/50 - 10314301 444747 444699 444166 444172 VSR35514 230/1/50 W10303102M 10314102 444744 444699 444164 - VSR35534 400/3/50 - 10314301 444747 444698 444166 444172 VSR40014 230/1/50 W10303102M 10314102 444744 444700 444164 - VSR40034 400/3/50 - 10314301 444747 444698 444166 444172 VSR45014 230/1/50 10303103 10314103 444744 444702 444164 - VSR45034 400/3/50 - 10314302 444747 444700 444166 444172 VSR45016 230/1/50 W10303102M 10314102 444744 444699 444164 - VSR45036 400/3/50 - 10314301 444747 444699 444166 444172 VSR50014 230/1/50 10303106 10314105 444744 444702 444164 - VSR50034 400/3/50 - 10314302 444747 444700 444166 444172 VSR50016 230/1/50 W10303102M 10314102 444744 444700 444164 - VSR50036 400/3/50 - 10314302 444747 444700 444166 444172 VSR56014 230/1/50 10303106 10314105 444744 444703 444164 - VSR56034 400/3/50 - 10314304 444747 444702 444166 444172 VSR56016 230/1/50 10314103 10314103 444744 444702 444164 - VSR56036 400/3/50 - 10314302 444747 444700 444166 444172 VSR63034 400/3/50 - 10314307 444747 444703 444166 444173 VSR63016 230/1/50 10303106 10314105 444744 444702 444164 - VSR63036 400/3/50 - 10314304 444747 444702 444166 444173 VSR71016 230/1/50 10303106 10314105 444744 444703 444164 - VSR71036 400/3/50 - 10314302 444747 444701 444166 444172 Accessories Model Ref Roof Attenuator Purlin Boxes Stock Ref Shutter Stock Ref BirdGuard Stock Ref 600mm Stock Ref 900mm Stock Ref 1200mm Stock Ref VSR250 RAZ300600 RAZ300900 RAZ3001200 PBZ300 RSZ300 BGZ300 VSR315 RAZ300600 RAZ300900 RAZ3001200 PBZ300 RSZ300 BGZ300 VSR355 RAZ300600 RAZ300900 RAZ3001200 PBZ300 RSZ300 BGZ300 VSR400 RAZ400600 RAZ400900 RAZ4001200 PBZ400 RSZ400 BGZ400 VSR450 RAZ400600 RAZ400900 RAZ4001200 PBZ400 RSZ400 BGZ400 VSR500 RAZ500600 RAZ500900 RAZ5001200 PBZ500 RSZ500 BGZ500 VSR560 RAZ500600 RAZ500900 RAZ5001200 PBZ560 RSZ500 BGZ500 VSR630 RAZ600600 RAZ600900 RAZ6001200 PBZ630 RSZ630 BGZ630 VSR710 RAZ600600 RAZ600900 RAZ6001200 PBZ710 RSZ630 BGZ630 For full range of speed controller options, see Accessories & Controllers Section. Three phase models are supplied with 2 speed delta/star connection motors, as standard. (Sizes 450 to 630 are 4/6 Pole, 710 are 6/8 pole).When low noise levels are required on all other models a 5 step auto transformer speed controller is recommended.Optional coloured Cowls and Bases available on request.

416 Mixed Flow Roof Fans (RMH) •Motors protected to IP44 •Motor insulation Class ‘B’ •Maximum operating temperature 40°C •Standard Thermal Overload Protection •IP65 service isolator •Bird guard included as standard •Speed controllable •Performance tested to BS 848 parts 1 & 2 •Manufacture controlled to BS EN ISO 9001 •2 Year Guarantee Specially designed for use when medium pressure characteristics are required, the Vent-Axia Mixed Flow Roof range is delivered on-site fully assembled and ready for installation.To meet COSHH requirements, a service isolator is fitted and pre-wired as standard. Equally suitable for flat or inclined roofs, the range is suitable for kerb or purlin box mounting and boasts a wide range of accessories to suit many different industrial applications. There are five sizes available with duties ranging from 0.606m 3 /s to 3.63m 3 /s (2182m 3 /h to 13068m 3 /h) with pressuredevelopment available up to 600 Pa. The mounting plate is moulded with a fixed integral bellmouth to ensure optimum efficiency and precise alignment. The weather-cowl is also moulded to produce a smooth, internal surface and a tough, stable UV resistant finish. Colour: BS 10A07. Alternative colours available on request. Vent-Axia mixed flow roof fans are designed for either kerb or inclined fixing (maximum angle 30°). Electrical Single phase 220-240V 50 Hz. Capacitor start and run. Three phase 380-415V 50Hz. A service isolator switch is provided for local isolation and the enclosure is protected to IP65 according to BS EN 60529. All motors are fitted with Standard Thermal Overload Protection (S.T.O.P.), which for three phase fans should be wired into all controller circuits and into starter contactors. Most models are available with 4 and 6 pole motors. Motors The Mixed Flow roof range features a proven external rotor motor and backward curved mixed flow glass reinforced polyamide impeller selected for performance and non-overloading characteristics. The assembly is dynamically balanced to VDI 2060. The motors in this range are rated IP44 according to BS EN 60529. Ball bearings are greased for life andare designed to run at any angle. Insulation is Class ‘B’ (from -30°C to +40°C). Manufacture is controlled to BS EN ISO 9001 standards. Sound Levels Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10 -5 Pa (20 micro- Pascal). The sound power level spectra figures are dB with a reference level of 10 -12Watts (1 pico-watt). Performance Tested to BS 848 Parts 1 & 2. Accessories Purlin boxes Available in sizes to suit all models and should be used to support the fan in conjunction with a soaker flange sheet. Roof attenuators Available in all sizes to cover the range of Mixed Flow Roof fans in three lengths: 600, 900 or 1200mm according to the attenuation required. Shutters Robust construction, designed to fit beneath the fan using the fittings provided. Airflow operated, manual or motorised shutter. A minimum distance of half the attenuator width is required between an airflow shutter and a roof attenuator for satisfactory operation.

417 Fan size ab c d e f g315 625 90 240 765 400 653 400 355 / 400 725 90 240 865 500 753 500 450 890 70 250 990 650 878 650 500 / 560 1030 75 250 1140 760 1028 790 Details for Purlin Mounting(Manufactured from 1.5mm pre-galv. mild steel). gMax. roof pitch 30 ° Fan size abcd e 250 500 500 280 90 16 315 700 680 410 83 16 355 / 400 500 700 570 - 83 450 650 850 690 - 103 500 / 560 790 990 842 100 103 Details for Kerb Mounting Fan size a bc d Weight Kg 250 500 500 280 90 16 315 700 680 410 83 16 355 / 400 800 780 480 83 24/27 450 950 930 575 103 45 500 / 560 1230 1055 630 103 48 / 64 Fan Dimensions (mm)

418 Performance Curve Performance Guide PhaseStock Curvem 3 /s at Pa Motor S.C. F.L.C. dBA Dia. Model Ref Pole rpm Ref 0 50 100 150 200 250 300 350 400 kW Amps Amps @ 3m 250 1 RMH25012 2 2720 1 0.25 0.23 0.21 0.19 0.17 0.15 0.13 0.11 0.09 0.16 2.1 0.7 62 315 1 RMH31514 4 1400 2 0.49 0.44 0.38 0.31 0.21 0.17 1.4 0.8 52 355 1 RMH35514 4 1410 3 0.87 0.77 0.65 0.51 0.33 0.31 4 1.45 56 400 1 RMH40014 4 1340 4 1.30 1.19 1.07 0.95 0.80 0.60 0.37 0.52 6 2.4 58 400 3 RMH40034 4 1340 4 1.30 1.19 1.07 0.95 0.80 0.60 0.37 0.54 4.2 1.05 58 450 1 RMH45014 4 1380 5 2.05 1.92 1.77 1.62 1.45 1.26 1.05 0.82 0.57 0.96 10.5 4.7 64 450 3 RMH45034 4 1380 5 2.05 1.92 1.77 1.62 1.45 1.26 1.05 0.82 0.57 0.89 5.9 1.65 64 500 1 RMH50014 4 1370 6 2.51 2.35 2.18 2.02 1.83 1.64 1.44 1.22 0.99 1.45 16 6.6 69 500 3 RMH50034 4 1370 6 2.51 2.18 2.02 1.83 1.64 1.44 1.22 0.99 1.35 10 2.4 69 560 3 RMH56034 4 1380 7 3.63 3.46 3.31 3.13 3.00 2.82 2.59 2.45 2.24 2.4 22 4.7 70 Sound Power Level Spectra dB (re 10 –12 Watts) Diameter Pole 63 125 250 500 1k 2k 4k 8k 250 2 69 75 80 78 76 74 73 66 315 4 64 75 77 70 60 63 63 51 355 4 65 68 75 73 73 70 59 53 400 4 66 73 79 77 73 72 68 61 450 4 71 76 84 83 83 80 77 65 500 4 73 82 87 84 84 82 76 68 560 4 75 83 90 87 85 85 82 73 S TA TIC PRESSUREPa 800 AIR VOLUME m 3 /h 0 m 3 /s 0 0 15000 10 0 20 0 30 0 40 0 50 0 60 0 70 0 1500 3000 4500 6000 750 0 9000 10500 1200 0 13500 0. 5 1 1. 5 2 2. 5 3 3. 5 4 4 7 1 6 1 3 1 4 1 5 250 - 560 dia - 4 Pole - 1 & 3 Phase 1 1 1 2

419 Performance Guide PhaseStock Curvem 3 /s at Pa Motor S.C. F.L.C. dBA Dia. Model Ref Pole rpm Ref 0 25 50 100 150 200 kW Amps Amps @ 3m 355 1 RMH35516 6 920 1 0.61 0.55 0.47 0.16 0.09 1.1 0.44 47 355 3 RMH35536 6 920 1 0.61 0.55 0.47 0.16 0.1 0.57 0.25 47 400 3 RMH40036 6 910 2 0.92 0.86 0.79 0.59 0.20 0.39 1.4 0.67 49 450 1 RMH45016 6 920 3 1.42 1.35 1.29 1.07 0.73 0.15 0.4 5.1 2.3 55 450 3 RMH45036 6 920 3 1.42 1.35 1.29 1.07 0.73 0.15 0.59 2 0.96 55 500 1 RMH50016 6 910 4 1.83 1.72 1.60 1.34 1.05 0.73 0.43 4.1 2.1 60 500 3 RMH50036 6 910 4 1.83 1.72 1.60 1.34 1.05 0.73 0.88 4.4 1.45 60 560 1 RMH56016 6 870 5 2.56 2.43 2.32 2.07 1.82 1.54 0.68 7.1 3.3 61 560 3 RMH56036 6 870 5 2.56 2.43 2.32 2.07 1.82 1.54 0.67 4.1 1.55 61 Sound Power Level Spectra dB (re 10 –12 Watts) Diameter Pole 63 125 250 500 1k 2k 4k 8k 355 6 59 60 66 63 63 61 50 46 400 6 60 63 69 77 64 62 59 52 450 6 65 67 75 73 72 70 68 55 500 6 67 73 77 75 75 72 67 59 560 6 68 73 80 78 76 75 73 64 S TA TIC PRESSUREPa 400 AIR VOLUME m 3 /h 0 m 3 /s 0 0 10000 50 10 0 15 0 20 0 25 0 30 0 35 0 1000 2000 3000 4000 500 0 6000 7000 8000 9000 0.25 0. 5 0.75 1 1.25 1. 5 1.75 2 2.2 5 2.5 4 5 4 4 2 4 3 1 1 355 - 560 dia - 6 Pole - 1 & 3 Phase Performance Curve

420 0 STA TIC PRESSURE Pa 100 0 MEAN DUCT VELOCITY m/s 1 2 3 4 5 6 7 8 9 10 10 20 30 40 50 60 70 80 90 4 2 1 1kg Face Area Curve Stock Ref abcd approx m 2 Ref 10520315 395 495 445 600 18 0.156 1 2 10520400 495 595 545 600 22 0.245 1 1 10520500 645 745 695 600 31 0.416 1 1 10520630 785 885 835 600 44 0.616 1 2 10521315 395 495 445 900 21 0.156 1 2 10521400 495 595 545 900 28 0.245 1 1 10521500 645 745 695 900 39 0.416 1 1 10521630 785 885 835 900 52 0.616 1 2 10522315 395 495 445 1200 25 0.156 1 2 10522400 495 595 545 1200 35 0.245 1 1 10522500 645 745 695 1200 48 0.416 1 1 10522630 785 885 835 1200 61 0.616 1 2 Accessories Dimensions (mm) Roof Attenuators Roof Attenuator, Insertion Losses Stock Ref. Length mm 63 125 250 500 1k 2k 4k 8k 105 20 315 600 2 4 9 16 20 22 18 14 105 20 400 600 2 4 8 15 18 20 17 13 105 20 500 600 2 4 9 16 20 22 18 14 105 20 630 600 2 4 8 15 18 20 17 13 105 21 315 900 3 6 13 22 30 31 22 17 105 21 400 900 2 6 12 20 25 27 20 16 105 21 500 900 3 6 13 22 30 31 22 17 105 21 630 900 2 6 12 20 25 27 20 16 105 22 315 1200 4 9 16 28 34 35 23 19 105 22 400 1200 4 8 15 26 32 33 21 18 105 22 500 1200 4 9 16 28 34 35 23 19 105 22 630 1200 4 8 15 26 32 33 21 18

421 Accessories eDemand Controller Electronic Auto Voltage 1/3 Phase 3 Phase Fan Controller Transformer Starter Overload Control Inverter Inverter Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref RMH25012 W10303102M 10314103 444744 444699 444164 - - RMH31514 W10303102M 10314103 444744 444699 444164 - - RMH35514 W10303102M 10314103 444744 444701 444164 - -RMH35516 W10303102M 10314103 444744 444698 444164 - -RMH35536 - 10314301 444747 444697 444166 444177 444172RMH40014 10303103 10314103 444744 444702 444164 - -RMH40034 - 10314301 444747 444700 444166 444177 444172RMH40036 - 10314301 444747 444699 444166 444177 444172RMH45014 10303106 10314105 444744 444703 444164 - -RMH45034 - 10314304 444747 444701 444166 444177 444172RMH45016 10303103 10314103 444744 444702 444164 - -RMH45036 - 10314301 444747 444700 444166 444177 444172RMH50014 10303110 10314107 444744 444702 444165 - -RMH50034 - 10314304 444747 444702 444166 444177 444173RMH50016 W10303102M 10314103 444744 444701 444164 - -RMH50036 - 10314304 444747 444701 444166 444177 444172RMH56034 - 10314307 444747 444703 444166 - 444173RMH56016 10303106 10314105 444744 444702 444164 - -RMH56036 - 10314304 444744 444702 444166 444177 444172Air Operated Shutters † Roof Attenuators Purlin 600mm † 900mm † 1200mm † Boxes Size Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref 315 10517315 10520315 10521315 10522315 10516315 355 10517315 10520315 10521315 10522315 10516315 400 10517400 10520400A 10521400 10522400 10516400 450 10517400 10520400A 10521400 10522400 10516400 500 - 10520500 10521500 10522500 10516500 560 - 10520500 10521500 10522500 10516500 630 - 10520630 10521630 10522630 10516630 †Air Operated Shutters and manual/motorisable Shutters are not suitable for use in combination with Roof Attenuators.Special manual/motorisable Shutters can be fitted to the bottom of the Roof Attenuator - Supplied by others For full range of speed controller options, see Accessories & Controllers Section

422 Lo-Carbon Energy Saver MX Roof Fans (MX) •Reduces your carbon footprint •Three stylish diagonal discharge models •70% energy savings •Customised performance from 2200m 3 /h to 6700m 3 /h•Can be remotely monitored •Designed for easy inspection access for cleaning,maintenance or servicing •Long life DC motor The Lo-Carbon MX Roof Range offers longer life, lower maintenance and energy savings to a variety of commercial and industrial applications. Three stylish diagonal discharge models MX10, MX20 and MX30 offer customised performances up to 5,500m 3 /h. The units are moulded in tough recyclable material, fully UV stabilised and are suitable for arduous external conditions. The design features a mixed flow impeller with the motor out of the airstream and a slanted diagonal discharge pattern which creates an upwardly spiralling discharge pattern. Suitable for horizontal mounting only (max. of 3° from horizontal). Motors At the heart of the range is the latest Lo-Carbon energy saver DC technology, eliminating the need for expensive transformer controllers to achieve customised duties. Due to the Lo-Carbon DC design, the motors run cooler, prolonging the life of the bearings and motor lubricants. The motor is integral to the mixed flow impeller and is designed for ambient duct temperatures up to +80°C. MX motors are up to 80% efficient in converting energy into rotation, providing large energy savings throughout the speed range. They are also precisely controllable, typically offering energy savings of 40-60% compared with AC equivalents. On Board Control The electronics in the Lo-Carbon MX range offer the possibility of setting any working point/speed whenever required without a controller. The standard unit is ready to connect to a single phase electrical supply. However, an ideal working point can be set either at the factory or on site to suit a system duty. If the system resistance or volume requirement changes, the fan duty can be re-programmed to meet this new performance on site. Traditional AC products are tied to 4, 6 and 8 pole models and costly transformers – the Lo-Carbon MX is simply set up at the desired speed and, if required, can be controlled using inexpensive switches connected by four core low voltage wire. The Lo-Carbon DC system can be controlled downto much lower speeds than AC motors providing very quiet performancewhen required. Maintenance Vent-Axia Lo-Carbon MX units have a built in fault diagnosis system. An installation of several units can be interconnected using simple two core wire to form a BUS network for flexible remote maintenance monitoring tailored to meet your needs. Vent-Axia MX maintenance software is available, the installation can be used on a laptop/PC. Alternatively a hand held diagnostics/programmer is available for on site use. Lo-Carbon MX units have their own encoded signature, allowing ease of identification and full performance history access.Vent-Axia’s Lo-Carbon MX range is designed for easy inspection access for cleaning. Four screws secure the main cover. Disconnect the internal mains plug and four bolts release the chassis holding the fan/motor assembly and the electronic module.The Lo-Carbon MX range is constructed from fully recyclable plastics. The diagonal vortex discharge pattern throws air and sound upwards and away from the roof surface. Lo-Carbon MX Sectional View Long lifelo-carbon motor Electroniccontrols Integral roofmounting plate Mixedflowimpeller Mouldedrecyclablematerial

423 1795kg carbonsaving max. 2000 rpm/2200 m 3 /h max. 1500 rpm/6700 m 3 /h MX 10/10 MX 30/20 Performance MX 10/10 - Stock Ref No: 45 46 12 MX 30/20 - Stock Ref No: 45 46 14 MX10 max. 2000 rpm/2200 m 3 /h MX20 max. 1600 rpm/3600 m 3 /h MX30 max. 1500 rpm/6700 m 3 /h Sound level Speed Current Power del.intakeintake rpm A Watts dB(A) dB(A) dB(A) 1800 0.76 174 57 72 63 1600 0.55 125 54 70 61 1400 0.39 87 50 66 58 1200 0.26 60 46 63 55 1000 0.17 39 41 58 51 800 0.12 27 36 56 49 600 0.09 19 30 49 42 400 0.07 12 24 41 35 Sound level Speed Current Power del.intakeintake rpm A Watts dB(A) dB(A) dB(A) 1200 1.9 433 60 75 65 1000 1.1 250 56 71 61 800 0.59 135 50 66 56 600 0.28 64 43 60 50 400 0.11 24 34 51 42 with GD silencer with GD silencer 400 350 300 250 200 150 100 50 0 0 500 1000 1500 2000 1800 1600 1400 1200 1000 800 600 400 m3/hPst Pa (N/m2) = MX= MX + GD max. sound pressure level max. power cons. max. 1600 rpm/3600 m 3 /h MX 20/10 MX 20/10 - Stock Ref No: 45 46 13 Sound level Speed Current Power del.intakeintake rpm A Watts dB(A) dB(A) dB(A) 1600 1.8 409 62 77 64 1400 1.16 266 58 74 62 1200 0.73 169 53 69 57 1000 0.44 100 48 65 54 800 0.25 57 42 59 49 600 0.14 31 36 55 45 400 0,09 17 28 48 39 with GD silencer 500 400 300 200 100 0 0 400 800 1200 1600 1600 1400 1200 1000 800 600400 2000 2400 2800 3200 3600 m3/hPst Pa (N/m2) = MX= MX + GD max. power cons. max. sound pressure level 600 500 400 300 200 100 0 0 1000 2000 5000 1400 1200 1000 800 600 400 m3/hPst Pa (N/m2) max. power cons. max. sound pressure level 3000 4000 = MX= MX + GD

424 I = = P L K M N O VG 31 DIMENSIONAL DETAILS J VG 31 Multi Unit Controller oC 10 0 -10 -30 -20 20 30 40 50 LT G B H G F D = = E C LT G DIMENSIONAL DETAILS A LTG Temperature Sensitive Speed Controller The LTG is an air temperature sensitive speed controller, which can be set between 20°C and 50°C. The controller is suitable for controlling up to 5 MX units when used in conjunction with a VG31 Multi Unit Controller. The fan will run at a minimum speed until the air temperature reaches the set point on the controller. When the set point is reached the controller will gradually increase the speed of the fan until the fan has reached its maximum speed. The fan speed gradient (min/max bandwidth), can be set from between 0.5°C and 10°C by adjusting a potentiometer within the controller housing. A probe fixed within the fan housing measures the air temperature. DØ F H B G Ø10(4X) A E Fan Dimensions (mm) B A C CTRS 50 A 50 X 50TIMBER 150 FLAT ROOF Upstand Dimensions Model MX10/10 MX20/10 MX30/20 A460 580 665 B330 450 535 D Ø 575 708 863 E 60 60 60 F 473 540 601 G 44 48 64 H 196 241 302Model ABCMX 10/10 275 375 330MX 20/10 400 500 450MX 30/20 485 585 535A 120B 28 C 28D 80E 27.5F 27.5G 60H 20 I 20 J 180 K 20 L 20 M 80 N 27.5 O 27.5 P 60

425 PC SOFTWARE(Available if required) BMS OR REMOTE LOCATION – CONNECT UP TO 31 UNITS NOTE: Please enquire as to the compatibility of an existing or proposed BMS. A BMS programme is available on request. Easy to monitor and maintain HAND HELD PROGRAMMER(Available upon request) Lo-Carbon MX Roof Range Alternative Management Controls I O Accessories SAG 0-2 2-step controller. Step 1 and 2 are separately adjustableStock Ref 454616 SAG 0-5 5-step controller adjustable maximum capacityStock Ref 454617 SAG 0-M Infinitely variable controller adjustable maximum capacityStock Ref 454618 Lo-Carbon MX Roof Range Fan Controls DNG 31 LTG Roof Attenuators Model SAG 0-2 SAG O-5 SAG 0-M 2 SpeedTemperature 600mm 900mm 1200mm RefStock RefStock RefStock RefStock RefStock RefStock RefStock RefStock RefMX 10/10 454616 454617 454618 456930 456931 - - - MX 20/10 454616 454617 454618 456930 456931 10520315 10521315 10522315 MX 30/20 454616 454617 454618 456930 456931 - - -

Air Handling Vent-Axia’s existing range of AHUs have been re-designed to comply with today’s more rigorous regulations. Now supplied with energy efficient EC motors, integral speed control and, where electric heating is included, integral electric heating controls. Casings are of a double skinned construction with a Pentapost aluminium frame, Aluzinc panels and 60kg/m 3acoustic insulation. The Slimline range is for internal mounting and consists of 2 base models with either Electric or LPHW heating, both with top or bottom access. The Mini Direct range is for internal or external mounting and consists of 5 base models with either electric or LPHW heating and side access. Both ranges can be inverted to allow connections from either left or right as standard. Specification Slimline MiniDirect Construction Double Skin Double Skin Drive EC Direct drive EC Direct Drive Impellers Backward Curved Centrifugal Access Top or Bottom Left or Right External - Internal Floor Suspended Heating LPHW Electric Dampers Optional Optional Filtration Bag M5 M5 Attenuators Optional Optional Controls Integral IntegralAirflow Range Model Airflow Range m 3 /s Slimline 0.05 0.92 MiniDirect 0.05 2.25 Volume m 3 /s 0 0.5 1 1.5 2 2.5 MiniDirect Slimline

Slimline Range (SL) 428-431 D1 to D6Mini Direct Range432-435

428 Low profile direct drive Air Handling Unit - Duties from 0.05m 3 /s to 0.92m 3 /s Updated to incorporate modern energy efficient EC motors these units are designed specifically for applications with limited available height such as ceiling voids. Access can be from above or below with heater and motor connections on the left or right hand side. The casing comprises of an AA25 anodised aluminium frame with high density glass reinforced nylon corners and double skinned Aluzinc panels enclosing 25mm of 60kg/m 3mineral fibre insulation. All panelsare retained by proprietary fasteners. All panels are sealed by a purpose designed leak seal gasket fully retained into the aluminium framework. Specification Direct driven backward curved centrifugal fans with energy efficient EC motors statically and dynamically balanced to G6.3 for smooth long life operation. All motors incorporate EC motor controls to provide fully variable speed control. Motors and control electronics are protected to IP44 as a minimum and are suitable for operating in ambient conditions of 40°C and up to 95% RH. Electrical supply is 230/1/50 for all units. Standard units contain either an electric heater battery or LPHW heater battery (specified at time of order) and an M5 filter. Units are suitable for internal mounting only. Electric heating units include a simple heater control enabling the off coil temperature to be set and either adjusted by external or internal controls (external controls at additional cost). LPHW heating controls are by others. Flexible Connectors The Flexible Connectors are manufactured from Revertex JPT 20 with ductmate flanges to DW142. Bag Filters Bag Filters are manufactured from fire retardant synthetic material with galvanised steel frames. The filter grade is M5. LPHW Heater Batteries LPHW Heater Batteries are constructed from copper tube, mechanically bonded to aluminium fins with the complete assembly housed in a galvanised steel casing. The coil headers and return bends are totally enclosed within the air handling unit casing. Flow and return connections arelocated on the same side of the unit andhave male B.S.P. thread. LPHW Heater Batteries are pressure tested under water to 250p.s.i. Electric Heater Batteries Electric Heater Battery elements areconstructed from Nichrome 5 spiral resistance wire surrounded by magnesium oxide powder and sheathed in stainless steel. The elements are carried on a galvanised steel frame. All electric heaters incorporate a thermal cut out device. Electrical connections are via a flush mounted terminal box on the outside of the air handling unit casing. Slimline Range (SL) •Performance range up to 0.92m 3 /s •Speed control included •EC Backward curved fans •Anodised aluminium pentapost frame •Double skinned Aluzinc panels •Low profile direct drive units •2 Year guarantee

429 Unit Dimensions (mm) Flex connection M5 bag filter Heating coil (LPHW shown) Access door A F H C B G D E Unit Ref A B C D E F G H SL6-22 1560 660 600 360 300 758 220 480 SL8-31 1560 810 750 360 300 758 220 480 Electrical / Heating Data Fan Supply Speed Max Fan Input W Heater Supply Max Heater KW(Electric) Heater CurrentAmps LPHW Heatermax Flow l/s Temperature Riseat Max Airflow SL6-22 230/1/50 3220 230 230/1/50 9 34 5.8 22 SL8-31 230/1/50 2600 450 400/3/50 18 25 12.9 22

430 Slimline Range (SL) Performance CurveAbsorbed Power kW 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 50 100 150 200 250 300 350 400 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Pr essure P a Air Volume m 3 /s 1 1 1 2 Performance Guide Airflow, m 3 /s @ Pa Model Curve Ref 0 50 100 150 200 250 300 350 400 SL6-22 1 1 m 3 /s 0.350 0.332 0.317 0.300 0.286 0.266 0.255 0.236 0.216 kW 0.13 0.13 0.14 0.15 0.17 0.18 0.18 0.19 0.19 SFP 0.36 0.39 0.43 0.49 0.59 0.66 0.71 0.79 0.89 SL8-31 1 2 m 3 /s 0.660 0.639 0.619 0.597 0.580 0.555 0.528 0.500 0.444 kW 0.43 0.43 0.44 0.45 0.45 0.45 0.45 0.45 0.44 SFP 0.66 0.68 0.71 0.75 0.77 0.81 0.86 0.91 0.99 Sound Data dBW re 10 -12 W Model 63 125 250 500 1k 2k 4k 8k dBA @ 3.0m SL6-22 Inlet 64 59 69 62 59 54 52 48 35 Outlet 66 61 73 65 65 63 57 55 Breakout 58 53 57 35 35 30 24 24 SL8-31 Inlet 62 65 70 69 60 63 59 56 40 Outlet 65 68 73 72 69 66 62 59 Breakout 57 60 57 42 39 33 29 26

431 Silencer Dimensions (mm) ACOUSTIC LENGTH NOTE: PLENUM END OF SILENCER MUST BE CONNECTED TO UNITDCLAL OVERALL FLANGE OVERALL FLANGE DUCTMATE 35 FLANGE Unit Dimensions in mm Approx Size L AL C D Wgt kg SL6-22 1500 1200 360 660 33 1800 1500 360 660 39 1200 900 360 810 37 SL8-31 1500 1200 360 810 42 1800 1500 360 810 48 Silencer resistance (Pa) standard length silencer UnitSize 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.8 0.9 1.0 SL6-22 2 4 7 11 16 22 29 37 - - - - - - - - SL8-31 1.5 3 5 8 11 15 19 24 30 36 43 51 59 77 97 120 Insertion loss for standard silencers Unit Length Octave band mid frequency Hz Size mm 63 125 250 500 1k 2k 4k 8k SL6-22 1200 -5 -9 -17 -28 -37 -37 -29 -24 1500 -7 -12 -25 -35 -50 -50 -38 -30 1800 -8 -15 -28 -42 -50 -50 -46 -34SL8-31 1200 -5 -9 -17 -28 -37 -37 -29 -24 1500 -7 -12 -25 -35 -50 -50 -38 -30 1800 -8 -15 -28 -42 -50 -50 -46 -34 Damper Dimensions (mm) FLEX DAMPER 200 165 30MM FLANGE CD OVERALL FLANGE AHU OVERALL FLANGE Dampers are supplied with extended spindles - suitable for motorisation as standard. Inlet Damper Dim in mm Approx Unit Size Stock Ref C D Wgt kg SL6-22 57CD-66 360 660 6 SL8-31 57CD-81 360 810 7

432 Mini Direct Drive Units Updated to incorporate modern energy efficient EC motors these simple Direct Drive Air Handling Units have a neat and compact design. Access can be on the left or right hand side. Units can be internal or external mounting (external specified at time of order). Mini Direct Drive Unit - Duties from 0.05m 3 /s to 2.25m 3 /s A compact and economical range of units with directly driven backward curved EC centrifugal fans. There are five standard unit sizes. All units incorporate speed control via the EC motor for added flexibility. The standard unit consists of a 100mm M5 panel filter, LPHW or electric heating, direct drive centrifugal fan and flexible connectors. The casing comprises of anodised aluminium frame with high density glass reinforced nylon corners and double skinned Aluzinc panels enclosing 25mm of 60kg/m 3mineral fibre insulation. All panels areretained by proprietary fixings and sealed by a purpose designed gasket fully retained into the aluminium framework Suitable for internal mounting as standard.Units supplied as standard are suitable for internal or external mounting, however for external mounting inlet weather cowls are available as an additional cost option. Specification Direct driven backward curved centrifugal fans with energy efficient EC motors statically and dynamically balanced to G6.3 for smooth long life operation. All motors incorporate EC motor controls to provide fully variable speed control. Motors and control electronics are protected to IP44 as a minimum and suitable for operating in ambient conditions of 40°C and up to 95% RH. Electrical supply is 230/1/50 for all units. Standard units contain either an electric heater battery or LPHW heater battery (specified at time of order) and an M5 filter. Units are suitable for internal or external mounting with side access. Electric heating units include a simple heater control enabling the off coil temperature to be set and either adjusted by external or internal controls (external controls at additional cost). LPHW heating controls are by others. Flexible Connectors The Flexible Connectors are manufactured from Revertex JPT 20 with ductmate flanges to DW142. Bag Filters Bag Filters are manufactured from fire retardant synthetic material with galvanised steel frames. The filter grade is M5. LPHW Heater Batteries LPHW Heater Batteries are constructed from copper tube, mechanically bonded to aluminium fins with the complete assembly housed in a galvanised steel casing. The coil headers and return bends are totally enclosed within the air handling unit casing. Flow and return connections are located on the same side of the unit and have male B.S.P. thread. LPHW Heater Batteries are pressure tested under water to 250 p.s.i. Electric Heater Batteries Electric Heater Battery elements are constructed from Nichrome 5 spiral resistance wire surrounded by magnesium oxide powder and sheathed in stainless steel. The elements arecarried on a galvanised steel frame.All electric heaters incorporate a thermal cut out device. Electrical connections are via a flush mounted terminal box on the outside of the air handling unit casing. D1 to D6 Mini Direct Range•Performance range up to 2.25m 3 /s •EC Backward curved fans •Anodised aluminium pentapost frame •Double skinned panels •Compact direct drive units •Internal or external mounting •1 Year guarantee

433 Fan Dimensions (mm) A Flex connection M5 bag filter LPHW coil EC Fan Access & pipe connections(invert unit for opposite handling) D F H G B C E Unit Size A B C D E F G H D1-22 1560 660 600 360 300 758 220 n/a D3-35 1560 660 600 520 460 780 220 300 D4-31 1560 660 600 720 660 780 220 300 D5-35 1710 960 900 720 660 850 220 450 D6-45 1710 1260 1200 720 660 850 220 450 Electrical / Heating Data Fan Supply Speed Max Fan Input W Heater Supply Max Heater KW(Electric) Heater CurrentAmps LPHW Heatermax Flow l/s Temperature Riseat Max Airflow D1-22 230/1/50 3220 230 230/1/50 9 34 5.8 22 D3-31 230/1/50 2600 450 400/3/50 12 17 8.6 22 D4-31 230/1/50 2600 430 400/3/50 18 25 12.9 22 D5-35 230/1/50 2460 1090 400/3/50 27 38 19.4 22 D6-45 230/1/50 2080 2360 400/3/50 45 63 32.4 22

434 Performance CurveAbsorbed Power kW 0.00 0.30 0.60 0.90 1.20 1.50 1.80 2.10 2.40 0 50 100 150 200 250 300 350 400 0.000 0.500 1.000 1.500 2.000 2.500 Pre ssure Pa Air Volume m 3 /s 1 1 1 2 1 3 1 4 1 5 Performance Guide Airflow, m 3 /s @ Pa Model Curve Ref 0 50 100 150 200 250 300 350 400 D1-22 1 1 m 3 /s 0.350 0.322 0.317 0.300 0.286 0.266 0.255 0.236 0.216 kW 0.13 0.13 0.14 0.15 0.17 0.18 0.18 0.19 0.19 SFP 0.36 0.39 0.43 0.49 0.59 0.66 0.71 0.79 0.89 D3-31 1 2 m 3 /s 0.670 0.647 0.639 0.619 0.597 0.580 0.555 0.528 0.500 kW 0.43 0.43 0.43 0.44 0.45 0.45 0.45 0.45 0.45 SFP 0.64 0.66 0.68 0.71 0.75 0.77 0.81 0.86 0.91 D4-31 1 3 m 3 /s 0.780 0.760 0.736 0.711 0.680 0.653 0.630 0.589 0.525 kW 0.41 0.41 0.42 0.42 0.42 0.43 0.44 0.44 0.45 SFP 0.52 0.53 0.57 0.59 0.62 0.66 0.70 0.75 0.86 D5-35 1 4 m 3 /s 1.400 1.333 1.294 1.264 1.242 1.216 1.183 1.130 1.111 kW 1.06 1.06 1.09 1.11 1.13 1.14 1.13 1.10 1.09 SFP 0.75 0.79 0.84 0.88 0.91 0.93 0.96 0.97 0.98 D6-45 1 5 m 3 /s 2.260 2.222 2.194 2.152 2.111 2.050 2.014 1.972 1.916 kW 2.08 2.08 2.12 2.14 2.23 2.26 2.29 2.35 2.40 SFP 0.92 0.94 0.97 0.99 1.05 1.10 1.14 1.19 1.25 Sound Data dBW re 10 -12 W Model 63 125 250 500 1000 2000 4000 8000 dBA @ 3.0m D1-22 Inlet 64 59 69 62 59 54 52 48 35 Outlet 66 61 73 65 65 63 57 55 Breakout 58 53 57 35 35 30 24 24 D3-31 Inlet 62 65 70 69 60 63 59 56 40 Outlet 65 68 73 72 69 66 62 59 Breakout 57 60 57 42 39 33 29 26 D4-31 Inlet 62 65 70 69 60 63 59 56 40 Outlet 65 68 73 72 69 66 62 59 Breakout 57 60 57 42 39 33 29 26 D5-35 Inlet 73 75 77 79 74 68 67 61 50 Outlet 73 76 81 82 83 79 73 66 Breakout 67 70 65 50 53 46 50 35 D6-45 Inlet 77 80 82 82 77 76 73 66 50 Outlet 73 76 81 82 83 79 73 66 Breakout 67 70 65 50 53 46 40 35 D1 to D6 Mini Direct Drive Range

435 Silencer Dimensions (mm)600, 900, 1200 OR 1500 AS REQUIRED DUCTMATE 35 FLANGE OVERALL FLANGECD OVERALL FLANGE300 Diffuser Dimensions (mm) Approx Unit Size Stock Ref C D Wgt kg D1 54BC1 360 660 18 D3 54BC3 520 660 32 D4 54BC4 720 660 40 D5 54BC5 720 960 46 D6 54BC6 720 1260 50 Insertion loss for standard silencers Unit Octave band mid frequency Hz Length Size 63 125 250 500 1k 2k 4k 8k mm D1 -4 -6 -12 -20 -27 -27 -20 -16 600 D3 -5 -9 -17 -28 -37 -37 -29 -24 900 D4 -5 -9 -17 -28 -37 -37 -29 -24 900 D5 -5 -9 -17 -28 -37 -37 -29 -24 900 D6 -5 -9 -17 -28 -37 -37 -29 -24 900N.B. For data on other silencer lengths please enquire Standard length silencer resistance (Pa) Unit Pressure Drop (Pa) Air Volume m 3 /sec Size 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.2 1.4 1.6 1.8 2 2.4 D1 2 8 18 - - - - - - - - - - - - - D3 1 4 8 14 21 31 41 54 - - - - - - - - D4 1 2 4 7 10 15 20 26 32 40 58 - - - - - D5 1 1 2 4 5 7 10 13 16 20 29 39 51 65 80 - D6 1 1 2 2 3 5 6 8 10 12 18 24 31 29 48 70 Inlet Damper Dimensions (mm) Dampers are supplied with extended spindles suitable for motorisation by others. When using a damper, a rigid connector will be required. DAMPER AHU X 100 30mm FLANGE OVERALL FLANGE OVERALL FLANGE D C Inlet Damper Rigid Connector Flexible Connector Dimensions (mm) Approx Unit Size Stock Ref. Stock Ref Stock Ref. C D X Wgt kg D1 57CD-66 54MC1 68FC-1 360 660 165 6 D3 57CD-3 54MC3 68FC-3 520 660 165 7 D4 57CD-4 54MC4 68FC-4 720 660 165 9 D5 57CD-5 54MC5 68FC-5 720 960 165 12 D6 57CD-6 54MC6 68FC-6 720 1260 165 25 Outlet Diffusers for Connection to Silencer This item is essential when connecting a silencer directly to the discharge sideof a fan section. The flanges at either end match the AHU and silencer dimension.

Accessories &Controllers - Non Residential Whether you are looking for ducting, controllers or accessories this is the section where you can find the details.Within each product area you can find product specific accessories, here you can find common items which fit a range of fans.This simple easy to use reference section provides you with all the details you need to complete the selection and specification of your project.

eDemand Controllers 438-445 Air Duct Heater 446-447 Speed Controllers & Accessories 448-463

438 eDemand Electronic Voltage Controller •Demand ventilation control for A/C speed controllable fans •Quick start-up by pre-programmed modes •IP54 Rated •Total motor protection using thermistor connection •LCD multi function display •Menu language – English, German, French, Italian •2 x analogue input for sensors (0-10V – separate powersupply required, 0-20mA) • CO 2Control •Temperature control •Constant pressure control •Manual remote speed adjuster (0-20 mA) •Min/Max speed limitation - Volume range set point adjustment Equipment/Function• Mains switch with by-pass function • Pin protection, to save user settings • Quick start up by pre-programmed modes • Max environmental conditions 40 Deg C, 85% Humidity no condensation • Readout events memory (checking Fault log) Technical Line voltage 1~ 230V (-15% / + 10%) 50/60 Hz Line Voltage 3~208V - 415V (-10%/+6%), 50/60 Hz Stock Ref 444164 444165 444166 444167 444168 Voltage 1 Phase 1 Phase 3 Phase 3 Phase 3 Phase Rated current / A 6 10 5 10 15 Max. line fuse / A 10 16 10 16 20 Max. heat dissip. /W 20 40 25 50 70 Weight / kg 1.4 2.4 2.4 2.8 4.8 Interference emissions EN 61000-6-3 (unshielded motor cable)Interference immunity EN 61000-6-2 For suitability check relevant fan accessory section Dimensions (mm) 223 198 131 115 200 137 23 1 Phase 6 Amp 115 132 240223 32 284 225 186 3 5.5Ø 13 1 Phase 10 Amp 115 132 223 32 284 225 240 3 186 13 5.5Ø 3 Phase 5/10 /15 Amp

439 eDemand Frequency Inverter 1~ to 3~ •Demand ventilation control for A/C speed controllable Fans •Quick start-up by pre-programmed modes •IP54 Rated •Total motor protection using thermistor connection •LCD multi function display •Menu language – English, German, French, Italian •2 x analogue input for sensors (0-10V – separate powersupply required, 0-20mA) • CO 2Control •Temperature control •Constant pressure control •Manual remote speed adjuster (0-20 mA) •Min/Max speed limitation - Volume range set point adjustment Equipment/Function• Pin protection, to save user settings • Quick start up by pre-programmed modes • Integrated SINEFILTER • Max environmental conditions 40 Deg C, 85% Humidity no condensation • Readout events memory (checking Fault log) • Speed control of fans without additional (electromagnetic) motor noise • Parallel operation of fans, no risk of motor damage (screened motor cables are not required) • Active power factor adjustment for sinusoidal input current • Integrated process controller (PID free programmable) Technical Line voltage 1~ 208 ... 277 V (-10 % / +10 %), 50/60 Hz Output voltage 3~230V (max. 250V) for 3~ motors in Δ connection Stock Ref 444177 Voltage 1 Phase Rated current / A 5 Max. line fuse / A 10 Max. heat dissip. /W 205 Weight / kg 6.6 Max output frequency 100 HzClock frequency 16 HzInterference emissions EN 61000-6-3 (unshielded motor cable)Interference immunity EN 61000-6-2 For suitability check relevant fan accessory section Dimensions (mm) 250 +2 6.5Ø 5 4 195.5 236 223 284 210 34 1 Phase 5 Amp

440 eDemand Frequency Inverter 3~ •Demand ventilation control for A/C speed controllable Fans •Quick start-up by pre-programmed modes •IP54 Rated •Total motor protection using thermistor connection •LCD multi function display •Menu language – English, German, French, Italian •2 x analogue input for sensors (0-10V – separate powersupply required, 0-20mA) • CO 2Control •Temperature control •Constant pressure control •Manual remote speed adjuster (0-20 mA) •Min/Max speed limitation - Volume range set point adjustment Equipment/Function• Pin protection, to save user settings • Quick start up by pre-programmed modes • Integrated SINEFILTER • Max environmental conditions 40 Deg C, 85% Humidity no condensation • Readout events memory (checking Fault log) • Speed control of fans without additional (electromagnetic) motor noise • Integrated SINEFILTER between phase to phase & phase to ground • Parallel operation of fans, no risk of motor damage (screened motor cables are not required) • Active power factor adjustment for sinusoidal input current • Integrated process controller (PID free programmable) Technical Line voltage 3 ~ 208...480 V (-15 % / +10 %), 50/60 Hz Stock Ref 444172 444173 444174 444175 444176 Rated current / A 2.5 5 8 14 18 Max. line fuse / A 6 10 10 16 20 Max. heat dissip. /W 50 100 150 310 400 Weight / kg 3.3 7.2 7.9 8.7 9.1 Max output frequency 100 HzClock frequency 16 HzInterference emissions EN 61000-6-3 (unshielded motor cable)Interference immunity EN 61000-6-2For suitability check relevant fan accessory section Dimensions (mm) 115 132 240223 32 284 225 186 3 5.5Ø 13 2.5 Amps 250 +2 212 6.5Ø 5 195.5 235 284 210 34 5/8/14/18 Amps

441 eDemand Frequency Inverter 1~ •Demand ventilation control for A/C speed controllable Fans •Quick start-up by pre-programmed modes •IP54 Rated •Total motor protection using thermistor connection •LCD multi function display •Menu language – English, German, French, Italian •2 x analogue input for sensors (0-10V – separate powersupply required, 0-20mA) • CO 2Control •Temperature control •Constant pressure control •Manual remote speed adjuster (0-20 mA) •Min/Max speed limitation - Volume range set point adjustment Equipment/Function• Pin protection, to save user settings • Quick start up by pre-programmed modes • Integrated SINEFILTER • Max environmental conditions 35 Deg C, 85% Humidity no condensation • Readout events memory (checking Fault log) • Speed control of fans without additional (electromagnetic) motor noise • Parallel operation of fans, no risk of motor damage (screened motor cables are not required) • Active power factor adjustment for sinusoidal input current • Integrated process controller (PID free programmable) Technical Line voltage 1~ 208 ... 277 V (-10 % / +10 %), 50/60 Hz Stock Ref 444169 444170 444171 Voltage 1 Phase 1 Phase 1 Phase Rated current / A 4 6 10 Input rated Current/ A 3.85 5.85 - Max. line fuse / A 6 10 16 Max. heat dissip. /W 57 102 130 Weight / kg 3.4 5.7 6.8 Max output frequency 100 HzClock frequency 16 HzInterference emissions EN 61000-6-3 (unshielded motor cable)Interference immunity EN 61000-6-2For suitability check relevant fan accessory section Dimensions (mm) 115 132 223 32 284 225 240 3 186 13 5.5Ø 4 Amps 250 +2 212 6.5Ø 5 195.5 235 284 210 34 6/10 Amps

442 eDemand Auto Changeover Panels •IP54Enclosure•eDemandcompatible•Single & Three Phase models•Adjustable duty/share timer•Automatic changeover (Fan Fail)•Fan failure alarm contacts Offering Demand Ventilation control for the wide range of standard AC speed controllable Twin fans, these changeover panels have been designed to complement the new range of eDemand Controllers and are fully compatible. Speed control input is suitable for use with the following eDemand Controller ranges: • Single & Three Phase electronic speed controllers • Single & ThreePhase inverters • Single to ThreePhase inverter ModelsModel Stock Ref Three Phase 16Amp 444179Single Phase 10Amp444180Single Phase 20Amp444181 Dimensions (mm)

443 Connection Diagrams Single Phase Electronic for 444164 & 444165 PE PE N N L1 N L1 PE Line depending on version1 ~ 230 V 50/60 Hzor 1 ~ 115 V 50/60 Hz L1 U1 U1 U2 U2 14 12 11 24 22 21 24V + + 1 DigitalIn 1 Analog In 2 2 K 1 K Contact rating max. AC 250 V 5 A Auto 0 100 % D3 (TB) D3 (TB) D1 (E3) A1GND A3 (D2) GND (D2) E2 GNDE1GND GND + 2 D1 (GND) ...6 F1=M10 A /...10 F1=FF20 A DigitalIn 2 Analog In 1 Analog Out 1 1 ~ Motorwith internal thermostats M 1 ~ PE U1 U2 TB TB Output 0...10 V (Imax = 10 mA) 3 Input 0...10 V 0...20 mA 4...20 mA TF..(KTY) 4 Input 0...10 V 0...20 mA 4...20 mA TF..(KTY) 5 1 2 6 E1 V mA °C E2 D- D+ GND 24V Data Data GND + - 24 V RS-485 1 Line voltage depending on version: 1 ~ 230 V, 5 0/60 Hz or 1 ~ 115 V, 50/60 Hz2 1 ~ Motor with internal thermostats 3 Output 0...10 V (Imax = 10mA) 4 Input 2: 0...10 V, 0...20 mA, 4...20 mA, TF.. (KTY) 5 Input 1: 0...10 V, 0...20 mA, 4...20 mA, TF..(KTY) 6 Contact rating max. AC 250 V 5 A A E1 GND 0-10 V 10 k0 - 10 V TF..24V E1 GNDDSG 0 - 10 V YE DSG.. (0 - 10 V) WH BN 24V E1 GND MAL 0 - 10 V 3 MAL1/10(0 - 10 V) 2 1 3 1 BN GNMBG..-I 24V E1 MBG.. (4 - 20 mA) E1 GND TF.. GNDThree Phase Electronic for 444166, 444167 & 444168

444 Single Phase Inverters for 444169, 444170 & 444171 N N L1 N L1 PE Line 1 ~ 208...277 V 50/60 Hz L1 U1 U1 U2 U2 14 12 11 24 22 21 + + 1 K1 K2 Contact rating max. AC 250 V 2 A A1 GND E2 GND E1 GND GND + 2 1 ~ Motor with internal thermostatsM 1 ~ PE U1 U2 TB TB Output 0...10 V (Imax = 6 mA) 3 Input 0...10 V 0...20 mA 4...20 mA 5 Input 0...10 V 0...20 mA 4...20 mA 4 1 2 6 D- D+ GND 24V Data Data GND+ - 24 V RS-485 TB TB D1 D1 D2 D2 DigitalIn 1 DigitalIn 2 AnalogOut 1 AnalogIn 1 AnalogIn 2 T2 T1 24V GND A2 AnalogOut 2 Temp 1/2TF..TF.. Normal Addressing 7 KTY 81-210 PT 1000 Auto 0 100 % 1 Line 1 ~ 208...277 V, 50/60 Hz 2 1 ~ Motor with internal thermostats 3 Output 0...10 V (Imax = 6 mA) 4 Input 1: 0...10 V, 0...20 mA, 4...20 mA, TF.. (KTY81-210), PT1000 5 Input 2: 0...10 V, 0...20 mA, 4...20 mA, TF.. (KTY81-210), PT10006 Contact rating max. 2A / 250 V AC7 Addressing, normal lock closed eDemand Auto Changeover Panels

445 Three Phase Inverters for 444172, 444173, 444174, 444175 & 444176 9 4 6 5 M 3~ PE V W U TB TB L3 N L2 L1 PE Line 3~ 208 .. 480 V50/60 Hz 12 14 11 22 24 21 GND A GND 24 V24 VE1 GNDE2 D1 D1 GNDD2 D2 D- D+ GND Data Data GND+ - Output 0 .. 10 V (Imax = 10 mA) Input 0..10 V 0 .. 20 mA 4 .. 20 mA TF.. (KTY) Input 0 ..10 V 0 .. 20 mA 4 .. 20 mA TF.. (KTY) 10 mm² / 2x Contact ratingmax. 2 A / 250 V AC K1 K2 GNDD+ D- Terminal AXG-1A(E) 24 V 24 V TK / PTC RS-485 Only in special versionsuitable for IT network! DigitalIn 1 AnalogOut 1 24V DCOut AnalogIn 1 AnalogIn 2 DigitalIn 2 TB / TPInE1 V °C mA E2 V °C mA E2.2 E2.1 E1.2 E1.1 V °C mA Switch or Jumper N L1 L2 L3 U V W Y/ + + 2 + 1 3~ Motorwith internal thermostats 2 Normal 3 8 Addressing 7 1 1 Line 3 ~ 208...480 V, 50/60 Hz2 Only in special version suitable for IT network!3 3 ~ Motor with internal thermostats4 Output 0...10 V (I max = 10 mA) 5 Input 1: 0...10 V, 0...20 mA, 4...20 mA, TF.. (KTY)6 Input 2: 0...10 V, 0...20 mA, 4...20 mA, TF.. (KTY)7 Addressing, normal lock closed8 Switch or jumper depending on version A E1 GND 0-10 V 10 k0 - 10 V TF..24V E1 GNDDSG 0 - 10 V YE DSG.. (0 - 10 V) WH BN 24V E1 GND MAL 0 - 10 V 3 MAL1/10 (0 - 10 V) 2 1 3 1 BN GNMBG..-I 24V E1 MBG.. (4 - 20 mA) E1 GND TF.. GND

446 The Vent-Axia range of sheathed element air duct heaters with built in control system provide a safe method of air heating which is economical to install and operate. Construction Circular Duct Air Heaters comprise of electric resistance elements, mounted in a pre-galvanised steel casing. Elements consist of a nickel/chromium resistance wire, spirally wound, insulated by compacted magnesium oxide powder and fitted within a stainless steel tube. The ends of each element are sealed with silicone rubber. Elements are return bent and mounted in the terminal box with airtight fixing glands. Standard terminal boxes are made from pre-galvanised sheet steel, 25mm conduit holes and earth stud are provided. The terminal boxes conform to IP30. Every heater is fitted with a high temperature safety cut out operating at 120˚C complete with push button manual reset. Available in 100, 125, 150, 200, 250, 315, 400 and 500mm diameter sizes. The air velocity across the heater elements must be greater than 2m/s and installed a minimum distance of one metre from the exhaust outlet of the fan unit. Mounting Heaters can be mounted in any position, vertical or horizontal. Care should be taken to ensure the cut out remainsoperational. Controls The Vent-Axia range of duct heaters with built-in controls are designed to be cost effective and space saving whilstmaintaining the features normally associated with larger control panels. Duct Air Heater Resistance Graph 0 10 20 30 40 50 60 2.0 3.0 4.0 5.0 6.0 7.0 Pressure Drop Pa Mean Duct Velocity m/s AirTrack Heaters•Supply and extract fan outputs •Combined temperature and airflow sensor •Run on timer •Solid state switching - no mechanical switching breakdown •Indicators for control status •High temperature limit and manual reset •Separate supply and extract fan outputs for heatersover 150mm dia

447 Duct Air Temperature Rise 10531100T1 (0.75kW) 10531125T1 (1.25kW) 10531150T1 (1.66kW) 2 1 10531200T1 (2kW) 10531200T1 (4 kW) 3 4 0 10 20 30 40 2.0 3.0 4.0 5.0 6.0 7.0 Temperature Rise °CVelocity m/s 2 1 3 4 0 10 20 30 40 2.0 3.0 4.0 5.0 6.0 7.0 Temperature Rise °CVelocity m/s 1 3 4 5 2 2 1 3 4 5 10531250T1 (6kW) 10531315T1 (4kW) 10531250T1 (3kW) 2 1 3 10531315T1 (8 kW) 10531315T3 (9kW) 4 5 0 10 20 30 40 2.0 3.0 4.0 5.0 6.0 7.0 Temperature Rise °CVelocity m/s 1 2 2 1 10531400T3 (12kW) 10531500T3 (21kW) 2 1 Dimensions (mm) Stock Ref Øab c kg 10531100T1 100 160 117 3 10531125T1 125 160 117 3.8 10531150T1 150 160 117 4 10531200T1 200 160 117 6 10531250T1 250 160 117 7.5 10531315T1 315 160 117 8.2 10531315T3 315 160 117 8.5 10531400T3 400 160 117 9.2 10531500T3 500 160 117 10

448 The RSC ELV (Extra Low Voltage) two speed selector has been especially developed for use with Industrial products to offer energy saving on all ventilation systems. Typically, ventilation systems are designed to cope with periods of peak demand, extracting expensively heated and conditioned air even through periods of low occupancy. Vent-Axia’s Two Speed Selector works by switching the power source between mains supply and a speed controller enabling reduction in the volume of air extracted during periods of low demand. The selection of power can be achieved by a Vent-Axia sensor or timer with volt free contacts or via a relay from the BMS (Building Management System). Connections between the RSC and the sensor are Extra Low Voltage. The RSC ELV two speed selector comprises of three modules, the RSC controller (103 14 230A)an electronic or 5-step auto-transformer appropriately rated to suit the fan and a Vent-Axia compatible sensor. The two speed changeover of the RSC ELV 24 is controlled by Vent-Axia compatible auto sensors utilising Extra Low Voltage wiring. With up to five speeds being available selected from a 5-step auto transformer controller. Electrical 9 Amp maximum rating on single phase 220V-240V/1/50Hz and three phase 380-415V/3/50Hz. Dimensions 86x178x100mm WxHxD. Models RSC ELV Speed Selector (Extra Low Voltage)Stock Ref10314230 Compatible Auto Sensors ThermoSwitchOperates on either a fall or rise in temperature for extraction of excess heat.Range 6˚C to 30˚C.Stock Ref 563502 7-Day TimeSwitch7-Day timer with analogue display.Override facility.Gives twelve On or Off positions per day. Stock Ref 563515 Ecotronic HumidistatAn electronic On/Off humidistat with concealed humidity adjustment 65-90% RH with pullcord override. Neon indicator. Changeover relay switch.Stock Ref 563550HumidiSwitchActuates ventilating units on either a rise or fall in humidity. Range 20% to 80% RH.Stock Ref 563501 Air Quality SensorAutomatically reacts to tobacco smoke, smells and toilet odours to trigger the system or switch to high speed.Stock Ref 563506 Visionex PIR DetectorCeiling mounted movement detector. Adjustable overrun timer 5 to 25 minutes.Fits any UK single gang mounting box. Range of detection up to 10 metres.220-240VStock Ref 459623RSC ELV Speed Selector•Stand alone two speed remote control of any industrial Vent-Axia speedcontrollable fan •Maximum rating 9 amp, 1 phase or 3 phase •Remote control via Vent-Axia sensors or relay in the BMS system •Night setback facility - saves energy •Extra low voltage wiring between controller and remote sensor •Enclosure protected to IP65

449 Duct Attenuators Easily installed, the duct attenuator is used in the system to absorb sound. Available in 100, 125, 150, 200, 250, 315 and 400mm diameter sizes. Manufactured in galvanised sheet metal with 50mm Rockwool sound absorption material.Maximum operating temp. 100˚C. Dimensions (mm) Stock Ref Øa Øb c d kg10534100 100 200 300 50 2.4 10534125 125 225 300 50 2.6 10534150 150 250 300 50 4.1 10535100 100 200 600 50 2.9 10535125 125 225 600 50 4.5 10535150 150 250 600 50 5.8 10535200 200 315 600 57.5 7 10535250 250 355 600 52.5 8.6 10535315 315 450 600 67.5 9.8 10535400 400 630 600 115 18 10536100 100 200 900 50 6.6 10536125 125 225 900 50 7.6 10536150 150 250 900 50 9 10536200 200 315 900 57.5 10 10536250 250 355 900 52.5 12.2 10536315 315 450 900 67.5 15 10536400 400 630 900 115 21 10537200 200 315 1200 57.5 14 10537250 250 355 1200 52.5 18 10537315 315 450 1200 67.5 21 10537400 400 630 1200 115 27 Resistance Graph 0 PRESSURE DROP(Pa) 8 15 0 MEAN DUCT VELOCITY m/s 5 10 1 2 3 4 5 6 7 Duct Attenuator Insertion Losses Stock RefLength Duct Ø 63 125 250 500 1k 2k 4k 8k 10534100 300 100 3 4 10 18 23 25 25 12 10534125 300 125 3 4 8 17 21 23 21 11 10534150 300 150 3 3 6 14 20 23 21 11 10535100 600 100 5 8 16 33 39 40 36 17 10535125 600 125 4 8 13 30 34 35 31 15 10535150 600 150 4 7 13 23 29 36 31 15 10535200 600 200 4 5 11 21 26 32 20 9 10535250 600 250 3 6 10 19 24 29 19 8 10535315 600 315 3 5 8 16 21 22 16 15 10535400 600 400 3 4 7 14 18 19 14 13 10536100 900 100 10 13 20 39 45 38 35 18 10536125 900 125 9 12 18 37 41 37 32 16 10536150 900 150 8 9 15 30 37 37 33 17 10536200 900 200 7 9 14 27 31 36 25 12 10536250 900 250 5 8 13 24 30 31 22 11 10536315 900 315 4 7 11 20 31 27 17 12 10536400 900 400 4 6 9 18 26 24 16 11 10537200 1200 200 10 12 17 35 40 43 27 13 10537250 1200 250 7 9 15 31 36 38 26 12 10537315 1200 315 6 8 13 23 32 30 18 11 10537400 1200 400 5 8 12 20 29 27 17 9 Duct Attenuators •Internal inline attenuator •Circular spigots with duct seal •Maximum airstream temperature 100°C •Duct lengths available 300, 600, 900 and 1200mm

450 Heat Exchange Unit A ‘stand alone’ heat exchange module which will transfer up to 70% of the outgoing heat to incoming air.Polymeric construction with spigots to suit 315mm flexible ductwork. Module accessible for routine cleaning.Condensate outlet provided.Ideal for use in air conditioned environments. The Heat Exchanger works at the same high efficiency, automatically keeping a cool room cool. By transferring heat from the extracted stale air, fresh pre-heated air is supplied to the room from outside, maintaining oxygen levels and preventing stuffiness. Maximum operating temperature 0˚C to 70˚C. (Weight 9kg) Heat Exchange ResistanceGraph 0 PRESSURE DROP(Pa) 1500 300 0 100 200 500 1000 VOLUME FLOW m 3 /h Thermal Efficiency Graph 0 THERMALEFFICIENCY% 1500 VOLUME FLOW m 3 /h 500 1000 50 100WARNING Both airflows to be subjected to the same conditions(ie. negative or positive pressure)Maximum differential pressure must not exceed 150Pa. Heat Exchange Unit •Stand alone heat exchanger unit •Up to 70% efficiency •200, 250 and 315 mm spigot connections available •Polymeric construction

451 Typical Installation Dimensions (mm) Dia. Stock Ref Weight 315 105382909 kgFoam ring to take up difference.

452 Electronic Controllers The 2.5 amp controller provides electronic motor speed control.On/Off with neon indicator, infinitely variable speed slider control, minimum speed presettable and optional sensor mode. Connections for use with external sensors are provided.3 and 6 amp electronic controllers provide infinitely variable speed control from preset minimum to maximum. Features an On/Off switch with neon indicator and speed control knob. Built in ‘Hard Start’ auto maximum speed for a few seconds.10 amp electronic controller provides infinitely variable speed control from preset minimum to maximum and feature On/Off Override switch for maximum speed. Neon indicator and built-in ‘Hard Start’ auto-maximum speed for a few seconds.For ambient temperatures between 30-40˚C the controller rating must be reduced by 2% for every 1˚C above 30˚C, eg. reduce by 10% at 35˚C.Stock Max. Dimensions (mm) WeightRef amps W x H x D kg W10303102M 2.5 156x86x53 0.410303103 3 150x90x65 0.510303106 6 150x90x65 0.510303110 10 167x220 x 130 1.3 Five Step Auto Transformers Used in conjunction with speed controllable fans to provide 5 stepped speed without electronic motor ‘hum and vibration’. Several fans can be connected to one transformer provided their combined load does not exceed the controller rating. Single phase: 2.0, 3.5, 6.0, 7.5, 9.0 and 14 amp. Three phase: 1.0, 2.0, 4.0, 7.0 and 14 amp.Rotary switch giving On/Off and five speeds.Output voltages at 240V/1PH/50Hz 0, 65, 110, 135, 170 and 240 volts.Output voltages at 415V/3PH/50Hz 0, 65, 110, 175, 285, 415 volts.Neon indicator. Three phase units complete with terminals for remote on/off switch Multi-unit Speed ControlWhen more than one fan is required to be controlled by one Auto Transformer, then the total combined FLC of all the fan units must not exceed 90% of the controllers maximum rating and not more than 2 x the total SC. The TKs must be wired in series. Fans without TKs or in-built S.T.O.P must not be wired in multiples.Single PhaseStock Ref Max Peak Load CurrentDimensions (mm) H x W x D Weight kg 10314102 2.0 230 x 168 x 118 1.0 10314103 3.5230 x 168 x 118 4.6 10314105 6.0230 x 166 x 118 5.0 10314107 7.5284 x 240 x 132 6.2 10314113 14.0316 x 270 x 168 16.5IP54 enclosuresThree Phase Stock Ref Max Peak Load Current Dimensions (mm) H x W x DWeight kg10314301 1.0 amps 284 x 240 x 132 4.7 10314304 † 4.0 amps 316 x 270 x 168 12.9 10314307 † 7.0 amps 324 x 270 x 168 15.6 10314311 † 14.0 amps 295 x 400 x 170 30.0 IP54 enclosure †IP21 enclosure Accessories

453 Direct on-line and Star Delta starters Suitable for all models. Push button Start/Stop. 240V contactor coil for single phase applications and three phase supplies where a neutral is present. 415V contactor coil for three phase supplies where a neutral is not present or required. Protection is given by an overload relay which is selected to match the load of the fan.Enclosures are protected to IP65.When ordered with the relevant sized Direct on Line or Star Delta starter the overloads are fitted within the starter. Overloads Stock Ref DOL Rating (Amps) Star Delta Rating (Amps) 444696 0.16-0.25 - 444697 0.25-0.4 - 444698 0.4-0.63 - 444699 0.63-1.0 - 444700 1.0-1.6 - 444701 1.6-2.25 2.7-4.3444702 2.5-4.0 4.3-6.9 444703 4.0-6.0 6.9-10 444704 5.5-8.0 9.5-13.8 444705 7-10 12-17 444706 10-13 17-22 444707 13-18 22-31 444708 18-25 31-43 444709 23-32 39-55DOL & Star Delta Starters Stock Ref Phase DOL Rating (Amps) Star Delta Rating (Amps) 444744 1 12 - 444745 1 25 - 444746 1 32 - 444747 3 12 - 444748 3 25 - 444749 3 32 - 444750 3 50 - 444842 - - 21 444843 - - 30l d

454 Accessories Bag Filter Cassettes Bag filter cassettes are available in a range of seven sizes. The synthetic filter medium is to EU5 Eurovent 4/5 94% arrestance. The housing is galvanised sheet metal with spigots fitted with integral seals. Quick release catches allow easy access to the bag filter. Replacement bag filters are available. Resistance Graph 0 PRESSURE (Pa) (clean) 7 150 0 VELOCITY m/s 1 2 3 4 5 6 100 50 Stock RefDia Spare filter 10533100 100mm 10557150 10533125 125mm 10557150 10533150 150mm 10557150 10533200 200mm 10557200 10533250 250mm 10557250 10533315 315mm 10557315 10533400 400mm 10557400 10533500 500mm 10557500Dimensions (mm) Stock Ref Øa b c d e kgs 10533100 100 200 203 450 540 4 10533125 125 200 203 450 540 4 10533150 150 200 203 450 540 4 10533200 200 245 248 450 560 5 10533250 250 295 298 500 620 7 10533315 315 345 348 550 670 8.5 10533400 400 445 448 650 770 12 10533500 500 600 600 650 770 12 Pre-Filter Cassettes Pre-filter cassettes are available in a range of seven sizes and are tested to EU3 (Eurovent 4/5) 85% arrestance. Housing is in galvanised sheet metal. Spigots are fitted with integral seals. Quick release catches allow access to the filter medium.Replacement pre-filters are available. Resistance Graph 0 PRESSURE DROP (Pa) (clean) 7 150 0 VELOCITY m/s 50 100 1 2 3 4 5 6Dimensions (mm) Stock RefØa b c d e kg 10532100 100 205 170 120 227 2 10532125 125 215 205 140 252 2 10532150 150 265 235 155 267 3 10532200 200 315 275 180 302 3.5 10532250 250 365 325 230 352 5.5 10532315 315 425 390 330 452 7 10532400 400 515 495 455 487 10.5Pre-filter cassettes Spare filter Diameter Stock RefStock Ref 100mm 10532100 10556100 125mm 10532125 10556125 150mm 10532150 10556150 200mm 10532200 10556200 250mm 10532250 10556250 315mm 10532315 10556315 400mm 10532400 10556400

455 Joining Pieces Used to join lengths of flexible ducting to give a long-lasting airtight connection. Manufactured from galvanised steel.Available in 100, 125, 150, 200, 315 and 400mm diameter sizes.Dimensions (mm)Stock Ref Dia 561804 100 561805 125 561806 150 561808 200 561810 250 561813 315 Worm Drive clips Stainless steel bands used for securing flexible ducting.Available to fit 100, 125, 150, 200, 250, 315, 355, 400, 450, 500, 560 and 630mm diameter sizes. Dimensions (mm) Stock Ref Dia 561704 100 561707 125 561707 150 561710 200 561710 250 561715 315 561715 355 561720 400 561720 450 561720 500 561726 560 561726 630

456 Accessories Louvred Shutters A range of twelve sizes of shutter with gravity return flaps to protect against backdraughts. The frame is manufactured from high impact polystyrene and the louvres from P.V.C. All components are UV stabilised. Resistance Graph 8 0 PRESSURE DROP(Pa) 50 0 MEAN DUCT VELOCITY m/s 1 2 3 4 5 6 7 10 20 30 40 Dimensions (mm) Typical Installation Stock Fixing hole Ref Dia. abc Ød eLS100 100mm 139 100 15 4 95 LS125 125mm 160 135 15 5 110 LS150 150mm 180 155 20 5 130 LS200 200mm 242 205 20 5 182 LS250 250mm 294 265 25 5 230 LS315 315mm 360 310 27 5 295 LS350 355mm 411 349 27 5 329 LS400 400mm 456 409 27 5 382 LS450 450mm 505 458 27 5 432 LS500 500mm 560 508 27 5 477 LS560 560mm 605 565 31 5 533 LS630 630mm 696 657 31 5 626 Fixing hole Louvred Grilles Louvred grilles can be used for air replacement for extract purposes and as an external louvre. Available in four sizes, the assembly fits over, rather than into the aperture making it especially useful where there are space restrictions within the duct. Manufactured in thermoplastic. Choice of three colours: Ivory, Brown or Grey. Resistance Graph 0 PRESSURE (Pa) (clean) 60 0 MEAN DUCT VELOCITY m/s 1 2 3 4 5 6 7 10 20 30 40 50 8Dimensions (mm)Louvred grilles Stock Ref Colour hole size a b W561431 Grey 230mm 310 303 561421 Ivory 230mm 310 303 561411 Brown 230mm 310 303 W561432 Grey 270mm 351 344 561422 Ivory 270mm 351 344 561412 Brown 270mm 351 344 W561433 Grey 300mm 391 388 561423 Ivory 300mm 391 388 561413 Brown 300mm 391 388 W561434 Grey 380mm 470 467 561424 Ivory 380mm 470 467 561414 Brown 380mm 470 467

457 Wall or Window Termination Sets Used to terminate flexible ducting at walls utilising worm drive clips.Flexible wall sleeve and fixing rods can be cut to suit varying wall thicknesses up to 360mm. Consists of: Direct mount spigot, grille, flexible wall sleeve and all fixings. Resistance Graph 0 PRESSURE (Pa) (clean) 60 0 MEAN DUCT VELOCITY m/s 1 2 3 4 5 6 7 10 20 30 40 50 8 HoleGrille required in Spigot Size ‘A’ wall window Stock Dia. H x W Ø Ø Ref100mm 220 x 226 210 184 W10554150 125mm 220 x 226 210 184 W10554150 150mm 220 x 226 210 184 W10554150200mm 258 x 265 240 222 W10554200250mm 302 x 304 290 260 W10554250315mm 378 x 381 370 337 W10554315 Roof Termination Sets Used to terminate flexible ducting at roofs utilising worm drive clips. Consists of: Direct mount spigot, adaptor kit, roof cowl, deflector and all screws. Resistance Graph 0 PRESSURE (Pa) (clean) 60 0 MEAN DUCT VELOCITY m/s 1 2 3 4 5 6 7 10 20 30 40 50 8 Dimensions (mm) Roof termination Dia. a b cØ Stock Ref 100mm 100 285 184 10555150 125mm 100 285 184 10555150 150mm 100 285 184 10555150 200mm 136 400 222 10555200 250mm 136 400 260 10555250 315mm 171 500 337 10555315 Roof plate assembly Termination Set Roof Plate Assembly 10555150 560136 10555200 560137 10555250 560139 10555315 560142

458 Backdraught ShuttersDuct sleeve manufactured from galvanised steel. The circular butterfly shutter is fitted with a return spring for positive closing.Available in 100, 125, 150, 200, 250, and 315mm diameter sizes. Resistance Graph 0 PRESSURE DROP(Pa) 40 0 MEAN DUCT VELOCITY m/s 1 2 3 4 5 6 7 5 10 15 20 25 30 35 8 Dimensions (mm) Stock Ref Dia a 10542100 100 88 10542125 125 88 10542150 150 88 10542200 200 88 10542250 250 128 10542315 315 128 Fast ClampsUsed to connect rigid ductwork to Airtrak fans. The clamp is manufactured from galvanised steel and features a thick neoprene rubber pad which is fixed on the inside.The clamp acts effectively as a vibration absorber and a noise suppressor. The fast clamp is tightened by two quick release bolts.Available in 100,125, 150, 200, 315 and 400mm diameter sizes. Max. operating temperature150˚C. Dimensions (mm) Stock RefDia 10540125 100 10540125 125 10540150 150 10540200 200 10540250 250 10540315 315 Accessories

459 3-Way Splitter For dividing a ventilation system, providing ducting to multiple supply or extract grilles using only a single fan source. Manufactured from high impact polymeric material with a maximum operating temperature of +50˚C. Resistance Graph 0 PRESSURE DROP(Pa) 15 0 MEAN DUCT VELOCITY m/s 1 2 3 4 5 6 7 5 10 8 Dimensions (mm) E D 45° 45° G C C B A F B Stock Ref AØ BØ CØ D EØ FØ G 10551250 - 250 200 45 150 - 500 10553400 400 315 300 45 200 250 625 Duct ‘Y’ Piece For dividing a ventilation system, providing ducting to multiple supply or extract grilles using only a single fan source.Available in fire retardant ABS. Dimensions (mm) Vent-Axia Duct Y Piece 2 x Dia. Into 1 x Dia. Stock Ref100 100 452081 100 150 452082 125 125 455211 125 150 455212 150 150 452083 150 200 452084 200 200 452085 200 250 452078 250 250 452076 250 300 452079

460 Circular Supply & Exhaust Diffusers Manufactured from powder coated steel. Suitable for supplying or exhausting air and can be fitted directly to the duct or in the ceiling. Available in 100, 125, 150, and 200mm diameter sizes. Dimensions (mm) eg. 100mm diameter supply diffuser. Design 15l/s flow3 turns ~ 30-35 dBA ~ 130Pa6 turns ~ 25-30 dBA ~ 40Pa 10 ST AT IC PRESSURE (Pa) 30 AIR FLOW l/s 40 50 15 20 100 200 100 80 60 40 15 20 5 Tu rn 30 40 50 10 150 Diameter 150m m AIR FLOW m 3 /h 300 70 SO UN D LEVELdBA 30 25 35 10 ST AT IC PRESSURE (Pa) 30 AIR FLOW l/s 40 50 100 150 200 200 100 80 60 40 20 15 20 25 4 6 Turn 30 25 8 30 40 50 10 35 SO UN D LEVELdBA 150 Diameter 125mm AIR FLOW m 3 /h ST AT IC PRESSURE (Pa) 30 AIR FLOW l/s 40 50 15 20 100 200 100 40 15 25 5 Tu rn 40 50 150 Diameter 200m m AIR FLOW m 3 /h 300 70 15 400 250 60 90 110 10 SO UNDLEVELdBA 30 25 35 150 ST AT IC PRESSURE (Pa) AIR FLOW l/s 60 100 200 50 30 10 15 Tu rn 150 Diameter 100mm AIR FLOW m 3 /h 40 15 30 50 100 0 10 20 20 5 200 300 25 30 35 SO UNDLEVELdBA 150 ST AT IC PRESSURE (Pa) AIR FLOW l/s 60 100 200 80 30 15 Turn 150 Diameter 125mm AIR FLOW m 3 /h 40 15 30 50 100 10 20 20 5 200 300 35 250 0 30 25 SO UN D L EV ELd BA 60 10 ST AT IC PRESSURE (Pa) 30 AIR FLOW l/ s 40 50 100 150 200 150 100 80 60 40 20 15 20 25 36 9 Turn Diameter 100m m 35 30 25 SO UN D L EV ELd BA AIR FLOW m 3 /h 100 ST AT IC PRESSURE (Pa) AIR FLOW l/s 30 50 200 60 Tu rn 150 Diameter 150mm AIR FLOW m 3 /h 40 15 30 50 100 10 20 5 150 200 300 60 80 100 20 25 35 30 25 SOUND LEVE LdBA 50 ST AT IC PRESSURE (Pa) AIR FLOW l/s 30 40 200 50 Tu rn 150 Diameter 200mm AIR FLOW m 3 /h 40 15 30 100 10 20 5 100 150 300 60 100 400 0 30 20 35 30 25 SOUND LEVELdBA Air Volume 240m 3 /h Grille to be unscrewed 15 full turns from fully closed position 70 Pa (Resistance) 30 Pa (Resistance) Exhaust Diffusers Curves Supply Diffusers Curves Weight Weight Stock valve frame Dia. Model Refa b c kg kg 100 Supply 10543100 100 80 150 0.15 0.09 125 Supply 10543125 125 96 158 0.16 0.13 150 Supply 10543150 150 115 195 0.23 0.15 200 Supply 10544200 200 163 210 0.34 0.18 100 Exhaust 10544100 100 70 143 0.12 0.09 125 Exhaust 10544125 125 96 158 0.15 0.13 150 Exhaust 10544150 150 115 195 0.20 0.15 200 Exhaust 10544200 200 163 210 0.34 0.18 Accessories

461 Plenum Boxes The Plenum box allows square grilles and diffusers to connect to circular duct.Each box size has a two diameter circular spigot for maximum versatility.The box is deep enough to accommodate both a double deflection grille and opposed blade damper. Manufactured in flame retardant high impact recyclable thermoplastic. Dimensions (mm) Single Deflection Grilles Suitable for either sidewall or exposed duct applications. A single row of blades permits up to 45˚ deflection of the air in one plane. Satin silver finish. Size 6/7 fits 300mm square modular size and size 9/12 fits 450mm square modular size. Eggcrate Grilles - Satin silver & white finishEggcrate grilles can be used for air replacement or air extract purposes. Used underneath Roof Plate Assemblies with roof models, underneath single spigots in ceilings, underneath mounting boxes and on the inside faces of walls that have units in fixed and removable wall plates on the outside of the wall. Comprising a 13mm square by 13mm deep mesh eggcrate core housed in a frame which has a satin silver or white finish. Size 6/7 fits 300mm square modular size and size 9/12 fits 450mm square modular size. Size 6/7 - 785cm 2free area Size 9/12 - 1810cm 2free area Eggcrate grilles satin silver finishUnit size Module size Stock RefSize 6/7 300 mm561301Size9/12 450 mm561302 Also available in the following sizes:- 200mm561303 250mm561305 Eggcrate grilles white finishUnit size Module size Stock RefSize 6/7 300 mm560849Size9/12 450 mm560850Also available in the following sizes:- 125mm560846 200mm560847 Stock RefAB CØ DØ E F 560601 200 130 125 150 25 25560602 250 130 150 175 25 25 560603 300 130 200 225 25 25 560604 300 130 250 300 25 25 560605 450 130 315 400 25 25Unit size Module size Stock RefSize 6/7 300 mm561372Size9/12 450 mm561373 Also available in the following sizes:- 200mm561370 250mm561371

462 4-Way DiffusersManufactured in light polypropylene plastic. With four diffuser cassettes which can be set for downward or 45 degree discharge in any of sixteen directional combinations. Fits ceiling grid size 595mmA F C E B D G Dimensions (mm) Performance 1 Way Blow 2 Way Blow 4 Way Blow Stock Ref abc d e fg10546230 265 224 60 20 5 102 112 10546300 335 292 60 22 5 136 140 10546350 390 345 60 22 5 162 168 10546400 440 395 75 22 8 183 190 10546450 490 459 75 22 8 208 21510546500 595 495 70 50 10 236 240 Stock Ref Neck Size Colour 10546230225mmIvory 10546300 300mmIvory 10546350 350mmIvory 10546400 400mmIvory 10546450 450mmIvory 10546500500mmIvory Diffuser Neck AdaptorStock Ref Sock Ref Duct Ø 10546230 OR 10547150 150 10546230 OR 10547200 200 10546300 10547250 250 10546350 10547300 300 10546400 10547400 400 10546450 10548400 400 10546500 10548000 315/400 1 2 4 8 15 25 50 100 300 Size Noise (NR) Th ro w ( m ) 350 400 450 500 200 3.0 2.5 20 25 30 35 3.5 4.0 4.5 5.0 6.0 400 800 1200 Pr e ssu reP a 1 2 4 8 15 25 50 100 300 230 Size Noise (NR) Thr ow (m) 350 400 450 500 200 3.0 20 18 15 25 30 35 3.5 4.0 2.5 2.0 400 800 1200 Pr e ssu reP a Volume l/s Volume l/s 1 2 4 8 15 25 50 100 300 Size Noise (NR) Thr ow (m) 350 400 450 500 200 20 15 25 30 35 2.5 3.0 3.5 1.5 2.0 400 800 1200 Pr e ssu reP a Volume l/s Accessories

463 Neck Adaptors Used to connect flexible ducting directly to 4-way diffusers for intake/extract applications. 4 - way Stock Ref diffuser size Duct Ø 10547150 225mm 150mm 10547200 225mm 200mm 10547250 300mm 250mm 10547300 350mm 315mm 10547400 400mm 400mm 10548400 450mm 400mm 10548000 500mm 315/400mm Dimensions (mm) bØ Sizes 150, 200, 250 & 300 aresupplied with a volume control flap.Stock DuctRef Dia. a Øb c 10547150 150 235 145 115 10547200 200 235 195 115 10547250 250 305 245 115 10547300 300/315 355 295 110 10547400 400 407 400 90 10548400 400 459 400 92 10548000 315/400 500 315/400 168 max Optional Air FlowDirection Mounting Types 1 Way 2 Way 2 Way 3 Way 3 Way 3 Way 2 Way 4 Way High Ceilings/Heating Spot Throw Cool Air Distribution Type 1 Type 2

By Appointment to H.M. The Queen Suppliers of Unit Ventilation Equipment Vent-Axia, Crawley, West Sussex VENT-AXIA CONTACT NUMBERS Free technical, installationandsales advice is available Sales Centre: Domestic & Commercial Sales Tel:0844 856 0590Sales Fax:01293 565169Tech Support Tel:0344 856 0594Tech Support Fax:01293 532814 Heating SupportSales Tel:0844 856 0590Tech Support Tel:0344 856 0594 IndustrialSales Tel:0844 856 0591Sales Fax:01293 534898Tech Support Tel:0344 856 0595Tech Support Fax:01293 532814Web: www.vent-axia.comEmail:sales@vent-axia.com Supply & Service All sales made by Vent-Axia Limited are made only uponthe terms of the Company’s Conditions of Sale, a copy ofwhich may be obtained on request. As part of the policy ofcontinuous product improvement Vent-Axia reserves the rightto alter specifications without notice. Vent-Axia Group Ltd Products you can trust A British company supporting British manufacturing 402406/0117